Background Recently, due to the rapid development of proteomic techniques, great advance has been made in many scientific fields. We aimed to use magnetic beads (liquid chip) based matrix-assisted laser desorption/i...Background Recently, due to the rapid development of proteomic techniques, great advance has been made in many scientific fields. We aimed to use magnetic beads (liquid chip) based matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) technology to screen distinctive biomarkers for lung adenocarcinoma (adCA), and to establish the diagnostic protein profiles. Methods Using weak cation exchange magnetic beads (MB-WCX) to isolate and purify low molecular weight proteins from sera of 35 lung adCA, 46 benign lung diseases (BLDs) and 44 healthy individuals. The resulting spectra gained by anchor chip-MALDI-TOF-MS were analyzed by ClinProTools and a pattern recognition genetic algorithm (GA). Results In the working mass range of 800-10 000 Da, 99 distinctive peaks were resolved in lung adCA versus BLDs, while 101 peaks were resolved in lung adCA versus healthy persons. The profile gained by GA that could distinguish adCA from BLDs was comprised of 4053.88, 4209.57 and 3883.33 Da with sensitivity of 80%, specificity of 93%, while that could separate adCA from healthy control was comprised of 2951.83 Da and 4209.73 Da with sensitivity of 94%, specificity of 95%. The sensitivity provided by carcinoembryonic antigen (CEA) in this experiment was significantly lower than our discriminatory profiles (P 〈0.005). We further identified a eukaryotic peptide chain release factor GTP-binding subunit (eRF3b) (4209 Da) and a complement C3f (1865 Da) that may serve as candidate biomarkers for lung adCA. Conclusion Magnetic beads based MALDI-TOF-MS technology can rapidly and effectively screen distinctive proteins/polypeptides from sera of lung adCA patients and controls, which has potential value for establishing a new diagnostic method for lung adCA.展开更多
Mass spectrometry imaging (MSI) technology can simultaneously obtain the spatial distribution of thousands of chemical compounds and has unique advantages compared to other techniques that allow mapping the surface of...Mass spectrometry imaging (MSI) technology can simultaneously obtain the spatial distribution of thousands of chemical compounds and has unique advantages compared to other techniques that allow mapping the surface of bio-tissue. Here, we combined an air flow-assisted desorption electrospray ionization (AFADESI) MSI device with a high-resolution mass spectrometer to optimize the system parameters and achieve more accurate spatial distribution characteristics for compounds of interest while investigating bio-tissue sections. The platform set-up, required instrumentation, sample pretreatment, parameter optimization and bio-tissue characterization are described and discussed.Finally, the parameter conditions that can provide optimal ionic intensity and enhanced resolution were confirmed. The reasonable resolution and sensitivity improvements of AFADESI-MSI have been achieved through tandem a high-resolution mass spectrometer system, therefore, it would be a promising technique for the bio-tissue imaging analysis.展开更多
A direct determination method for the atrazine residue on the vegetable was developed by using desorption electrospray ionization mass spectrometry (DESI MS) without any sample pretreatment.Acetonitrile-water (1:1,v/v...A direct determination method for the atrazine residue on the vegetable was developed by using desorption electrospray ionization mass spectrometry (DESI MS) without any sample pretreatment.Acetonitrile-water (1:1,v/v),which contained 0.1% formic acid,was used as the spray solvent.The working conditions,such as ESI gas inlet pressure,ESI flow rate,ESI spray voltage,spray-to-sample distance,spray-to-cone-hole distance and the collision induced dissociation (CID) voltage for MS/MS,were optimized for both DESI and esquires 6 000 mass spectrometer.The linear range of atrazine on cabbage leaves was 25.25-2 525 pg/mm2,the R2 was 0.991 6,and the relative standard deviations were between 3.37% and 26.17%.The LOD of atrazine calculated by S/N=3 was 2.50 pg/mm2.展开更多
基金This work was supported by grants from the National Natural Science Foundation of China (No. 30570795) and Program for New Century Excellent Talents in University (No. NECT-06-0845) and the Program in Science and Technology of Xi'an, Shaanxi Province (No. S F08009(1)).Acknowledgement: We are grateful to HU Xiao-hui for the technical guidance.
文摘Background Recently, due to the rapid development of proteomic techniques, great advance has been made in many scientific fields. We aimed to use magnetic beads (liquid chip) based matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) technology to screen distinctive biomarkers for lung adenocarcinoma (adCA), and to establish the diagnostic protein profiles. Methods Using weak cation exchange magnetic beads (MB-WCX) to isolate and purify low molecular weight proteins from sera of 35 lung adCA, 46 benign lung diseases (BLDs) and 44 healthy individuals. The resulting spectra gained by anchor chip-MALDI-TOF-MS were analyzed by ClinProTools and a pattern recognition genetic algorithm (GA). Results In the working mass range of 800-10 000 Da, 99 distinctive peaks were resolved in lung adCA versus BLDs, while 101 peaks were resolved in lung adCA versus healthy persons. The profile gained by GA that could distinguish adCA from BLDs was comprised of 4053.88, 4209.57 and 3883.33 Da with sensitivity of 80%, specificity of 93%, while that could separate adCA from healthy control was comprised of 2951.83 Da and 4209.73 Da with sensitivity of 94%, specificity of 95%. The sensitivity provided by carcinoembryonic antigen (CEA) in this experiment was significantly lower than our discriminatory profiles (P 〈0.005). We further identified a eukaryotic peptide chain release factor GTP-binding subunit (eRF3b) (4209 Da) and a complement C3f (1865 Da) that may serve as candidate biomarkers for lung adCA. Conclusion Magnetic beads based MALDI-TOF-MS technology can rapidly and effectively screen distinctive proteins/polypeptides from sera of lung adCA patients and controls, which has potential value for establishing a new diagnostic method for lung adCA.
基金supported by the National Instrumentation Program (No. 2016YFF0100304)the National Natural Science Foundation of China(Nos. 21335007, 81773678)+1 种基金the CAMS Innovation Fund for Medical Sciences(No. 2016-12 M-1-009)PUMC Youth Fund and the Fundamental Research Funds for the Central Universities(No. 3332015177)
文摘Mass spectrometry imaging (MSI) technology can simultaneously obtain the spatial distribution of thousands of chemical compounds and has unique advantages compared to other techniques that allow mapping the surface of bio-tissue. Here, we combined an air flow-assisted desorption electrospray ionization (AFADESI) MSI device with a high-resolution mass spectrometer to optimize the system parameters and achieve more accurate spatial distribution characteristics for compounds of interest while investigating bio-tissue sections. The platform set-up, required instrumentation, sample pretreatment, parameter optimization and bio-tissue characterization are described and discussed.Finally, the parameter conditions that can provide optimal ionic intensity and enhanced resolution were confirmed. The reasonable resolution and sensitivity improvements of AFADESI-MSI have been achieved through tandem a high-resolution mass spectrometer system, therefore, it would be a promising technique for the bio-tissue imaging analysis.
文摘A direct determination method for the atrazine residue on the vegetable was developed by using desorption electrospray ionization mass spectrometry (DESI MS) without any sample pretreatment.Acetonitrile-water (1:1,v/v),which contained 0.1% formic acid,was used as the spray solvent.The working conditions,such as ESI gas inlet pressure,ESI flow rate,ESI spray voltage,spray-to-sample distance,spray-to-cone-hole distance and the collision induced dissociation (CID) voltage for MS/MS,were optimized for both DESI and esquires 6 000 mass spectrometer.The linear range of atrazine on cabbage leaves was 25.25-2 525 pg/mm2,the R2 was 0.991 6,and the relative standard deviations were between 3.37% and 26.17%.The LOD of atrazine calculated by S/N=3 was 2.50 pg/mm2.