The production cross-sections, intensity ratios, and radiative Auger intensity ratios of Co, Ni, Cu, and Zn elements in different complexes were measured. The chemical effects on the K shell fluorescence parameters an...The production cross-sections, intensity ratios, and radiative Auger intensity ratios of Co, Ni, Cu, and Zn elements in different complexes were measured. The chemical effects on the K shell fluorescence parameters and the radiative Auger intensity ratios of these elements were investigated and the changes in these parameters were interpreted according to the charge transfer process. The samples were excited by 59.5 keV γ-rays from a ^241Am annular radioactive source. K X-rays emitted by samples were counted by an Ultra-LEGe detector with a resolution of 150 eV at 5.9 keV.展开更多
An electronic personal dosimeter mainly uses a Si-PIN photodiode as X-and gamma-ray detectors.The photon energy response of this instrument is inconsistent in the case of no correction,which seriously affects the accu...An electronic personal dosimeter mainly uses a Si-PIN photodiode as X-and gamma-ray detectors.The photon energy response of this instrument is inconsistent in the case of no correction,which seriously affects the accurate monitoring of personal dose equivalent H_p(10)parameters for radiation workers.For this reason,in this paper we propose a method of combining composite screen detection technology,multichannel measurement technology,and the channel ratio method to achieve accurate measurement of the personal dose equivalent parameters.According to China National Standard GB/T 13161-2003 and National Verification Regulation JJG 1009-2006,the instrument was tested in the energy range between 48 keV and 1.25 MeV.The experimental results showed that the difference of energy response to ^(137)C_S corrected by the new method was almost constant within ±6.0%,which fulfilled the ±30% requirement of GB/T 13161-2003 and JJG1009-2006.Meanwhile,the method proposed obtained energy information regarding the radiation field.展开更多
The article uses the method of regression statistics to obtain the regression formula of iron fluid nodule ratio Q and compacted graphite ratio R, through rare earth magnesium treatment. At the same time it has given ...The article uses the method of regression statistics to obtain the regression formula of iron fluid nodule ratio Q and compacted graphite ratio R, through rare earth magnesium treatment. At the same time it has given thejudging figure of Q and R, considering oxygen activity and temperature. When using oxygen activity to judgenodule ratio and compacted graphite ratio of the ironfluid treated by rare earth magnesium alloy, its limit value changes with the change of temperature.展开更多
高灵敏度的红外探测系统对于远距离探测有巨大的潜力,但光学系统内部的噪声会抑制探测系统的信噪比,从而降低探测灵敏度与探测距离.本文基于红外超导纳米线单光子探测器,设计了一个工作在中红外波段的光学系统,构建了红外光学系统自发...高灵敏度的红外探测系统对于远距离探测有巨大的潜力,但光学系统内部的噪声会抑制探测系统的信噪比,从而降低探测灵敏度与探测距离.本文基于红外超导纳米线单光子探测器,设计了一个工作在中红外波段的光学系统,构建了红外光学系统自发辐射计算模型,理论分析了红外光学系统的信噪比和噪声特性.首次提出了利用高性能超导单光子探测器精确表征红外光学系统的微弱背景辐射光信号,为优化设计红外系统提供了依据.并且基于超导单光子探测器的光子计数能力,研究了光学系统的背景辐射对红外探测系统性能的影响,并优化了光学系统的性能.实验结果表明,超导单光子探测器对于分析红外光学系统具有较高的灵敏度,最小可分辨移动距离为2.74×10^(-2)mm,在黑体温度为100℃时,光子计数率提高了6.4×10^(4)cps(1 cps=1 cycle per second),光学系统的耦合效率提升了97%;在黑体温度为102℃时,光子计数率提高了9.1×10^(4)cps,光学系统的耦合效率提升了114%,降低了杂散辐射对探测系统的影响,同等条件下系统信噪比提升2.7倍,对于超导红外探测系统的应用研究具有重要意义.展开更多
文章研究了背景为子空间干扰加高斯杂波的距离扩展目标方向检测问题。杂波是均值为零协方差矩阵未知但具有斜对称特性的高斯杂波,目标与干扰分别通过具备斜对称特性的目标子空间和干扰子空间描述。针对方向检测问题,利用上述斜对称性,...文章研究了背景为子空间干扰加高斯杂波的距离扩展目标方向检测问题。杂波是均值为零协方差矩阵未知但具有斜对称特性的高斯杂波,目标与干扰分别通过具备斜对称特性的目标子空间和干扰子空间描述。针对方向检测问题,利用上述斜对称性,根据广义似然比检验(Generalized Likeli-hood Ratio Test,GLRT)准则的一步与两步设计方法,设计了基于GLRT的一步法与两步法的距离扩展目标方向检测器。通过理论推导证明了这2种检测器相对于未知杂波协方差矩阵都具有恒虚警率。对比相同背景下已有检测器,特别是在辅助数据有限的场景下,文章提出的2个检测器表现出了优越的检测性能。展开更多
文摘The production cross-sections, intensity ratios, and radiative Auger intensity ratios of Co, Ni, Cu, and Zn elements in different complexes were measured. The chemical effects on the K shell fluorescence parameters and the radiative Auger intensity ratios of these elements were investigated and the changes in these parameters were interpreted according to the charge transfer process. The samples were excited by 59.5 keV γ-rays from a ^241Am annular radioactive source. K X-rays emitted by samples were counted by an Ultra-LEGe detector with a resolution of 150 eV at 5.9 keV.
基金supported by the National Key Scientific Instruments To Develop Dedicated(2013YQ090811)
文摘An electronic personal dosimeter mainly uses a Si-PIN photodiode as X-and gamma-ray detectors.The photon energy response of this instrument is inconsistent in the case of no correction,which seriously affects the accurate monitoring of personal dose equivalent H_p(10)parameters for radiation workers.For this reason,in this paper we propose a method of combining composite screen detection technology,multichannel measurement technology,and the channel ratio method to achieve accurate measurement of the personal dose equivalent parameters.According to China National Standard GB/T 13161-2003 and National Verification Regulation JJG 1009-2006,the instrument was tested in the energy range between 48 keV and 1.25 MeV.The experimental results showed that the difference of energy response to ^(137)C_S corrected by the new method was almost constant within ±6.0%,which fulfilled the ±30% requirement of GB/T 13161-2003 and JJG1009-2006.Meanwhile,the method proposed obtained energy information regarding the radiation field.
文摘The article uses the method of regression statistics to obtain the regression formula of iron fluid nodule ratio Q and compacted graphite ratio R, through rare earth magnesium treatment. At the same time it has given thejudging figure of Q and R, considering oxygen activity and temperature. When using oxygen activity to judgenodule ratio and compacted graphite ratio of the ironfluid treated by rare earth magnesium alloy, its limit value changes with the change of temperature.
文摘高灵敏度的红外探测系统对于远距离探测有巨大的潜力,但光学系统内部的噪声会抑制探测系统的信噪比,从而降低探测灵敏度与探测距离.本文基于红外超导纳米线单光子探测器,设计了一个工作在中红外波段的光学系统,构建了红外光学系统自发辐射计算模型,理论分析了红外光学系统的信噪比和噪声特性.首次提出了利用高性能超导单光子探测器精确表征红外光学系统的微弱背景辐射光信号,为优化设计红外系统提供了依据.并且基于超导单光子探测器的光子计数能力,研究了光学系统的背景辐射对红外探测系统性能的影响,并优化了光学系统的性能.实验结果表明,超导单光子探测器对于分析红外光学系统具有较高的灵敏度,最小可分辨移动距离为2.74×10^(-2)mm,在黑体温度为100℃时,光子计数率提高了6.4×10^(4)cps(1 cps=1 cycle per second),光学系统的耦合效率提升了97%;在黑体温度为102℃时,光子计数率提高了9.1×10^(4)cps,光学系统的耦合效率提升了114%,降低了杂散辐射对探测系统的影响,同等条件下系统信噪比提升2.7倍,对于超导红外探测系统的应用研究具有重要意义.
文摘文章研究了背景为子空间干扰加高斯杂波的距离扩展目标方向检测问题。杂波是均值为零协方差矩阵未知但具有斜对称特性的高斯杂波,目标与干扰分别通过具备斜对称特性的目标子空间和干扰子空间描述。针对方向检测问题,利用上述斜对称性,根据广义似然比检验(Generalized Likeli-hood Ratio Test,GLRT)准则的一步与两步设计方法,设计了基于GLRT的一步法与两步法的距离扩展目标方向检测器。通过理论推导证明了这2种检测器相对于未知杂波协方差矩阵都具有恒虚警率。对比相同背景下已有检测器,特别是在辅助数据有限的场景下,文章提出的2个检测器表现出了优越的检测性能。