A primary study on Processing in X - ray inspection of spot weld for aluminum alloy spot welding,in- cluding for background simulation,acquisition of ideal binary image, and extraction and identifi- cation of defec...A primary study on Processing in X - ray inspection of spot weld for aluminum alloy spot welding,in- cluding for background simulation,acquisition of ideal binary image, and extraction and identifi- cation of defect features was presented.展开更多
A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5-0.9 nm range. A large open aperture (30 ×20 (mm)) mica (002) spheri...A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5-0.9 nm range. A large open aperture (30 ×20 (mm)) mica (002) spherically bent crystal with curvature radius R = 380 mm is used as dispersive and focusing element. The imaging plate is employed to obtain high spectral resolution with effective area of 30 × 80 (mm). The long designed path of the X-ray spectrometer beam is 980 mm from the source to the detector via the crystal. Experiment is carried out at a 20-J laser facility. X-ray spectra in an absolute intensity scale is obtained from Al laserproduced plasmas created by laser energy of 6.78 J. Samples of spectra obtained with spectral resolution of up to E/△E - 1500 are presented. The results clearly show that the device is good to diagnose laser high-density plasmas.展开更多
A four-channel Kirkpatrick Baez microscope working at multiple energy bands is developed for multiframe X-ray imaging diagnostics at the Shenguang-II laser facility. The response to the multiple energy bands is realiz...A four-channel Kirkpatrick Baez microscope working at multiple energy bands is developed for multiframe X-ray imaging diagnostics at the Shenguang-II laser facility. The response to the multiple energy bands is realized by coating the double-periodic multilayers on the reflected surfaces of the microscope. Because of the limited size of the microstrips in the X-ray framing camera, the image separation is controlled by the coni- cal angle of the reference cores during microscope assembly. This study describes the optical and multilayer design, assembly, and aligmnent of the developed microscope. The microscope achieves a spatial resolution of 4 5 gin in the laboratory and 10 20 ~tm at Shenguang-II laser facility within a 300 tim field of view. The versatile nature of the developed microscope enables the multiple microscopes currently installed in the laser facility to be replaced with a single, multipurpose microscope.展开更多
A four-channel multilayer Kirkpatrick-Baez (KB) microscope is developed for the 8-keV X-ray imaging of experiments on laser inertial confinement fusion (ICF). A periodic multilayer that works at 8 keV and with a g...A four-channel multilayer Kirkpatrick-Baez (KB) microscope is developed for the 8-keV X-ray imaging of experiments on laser inertial confinement fusion (ICF). A periodic multilayer that works at 8 keV and with a grazing incidence angle of 1.0~ is coated on reflective surfaces to achieve a spatial resolution higher than 5μm and an effective solid angle higher than 10-7 sr. A precise assembly is realized by a conical reference cone to couple with an X-ray framing camera. This study provides detailed information on an optical and multilayer design, assembly method, and experimental results with a Cu X-ray tube. The instrument provides a high-resolution and high-throughput X-ray image for backlit or self-emission imaging of laser plasma at Cu Kα line radiation in Shenguang series laser facilities.展开更多
A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility ...A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility (SG-II). The microscope uses a total external reflection mirror in the sagittal direction and an array of multilayer mirrors in the tangential direction to obtain multiple individual high-resolution, high- throughput, and quasi-monochromatic X-ray images. The time evolution of the imploded target in multiple X-ray energy bands can be acquired when coupled with an X-ray streak camera. The experimental result of the time-resolved 2.5 and 3.0 keV dual-spectral self-emission imaging of the undoped CH shell target on SG-II is given.展开更多
Microstructural change of YBaCuO film/YSZ substrate with and without proton irradiation has been studied by scanning electron microscope and X- ray diffraction techniques. Structural analysis has shown that conversion...Microstructural change of YBaCuO film/YSZ substrate with and without proton irradiation has been studied by scanning electron microscope and X- ray diffraction techniques. Structural analysis has shown that conversion from tetragonal to orthorhombic phases, reduction of nonsuperconducting phase and preferential rearrangement of crystal grains are all favorable to the improvement of superconductivity in the YBaCuO film supported by YSZ substrate by proton beam bombardment.展开更多
This paper summarizes the new developments in the study of barium rare-earth fluor-carbonate mineral structures .The second order superstructure of cebaite -(Ce ) was solved by using high power X-ray single crystal di...This paper summarizes the new developments in the study of barium rare-earth fluor-carbonate mineral structures .The second order superstructure of cebaite -(Ce ) was solved by using high power X-ray single crystal diffractometer . Five kinds of coordination forms were found . All atoms in the cell , including C and F , were properly located . In the process of study in a cordylite-(Ce ), a new mineral was discovered , whose chemical formula is (Ca0.5□0.5) BaCe2 (CO3)4F . It is isostructural with baiyuneboite - (Ce ), but different in composition (Na in baiyuneboite- (Ce ) is substituted by Ca disorderly ) . On the basis of the studies a proposal to re-define cordylite-(Ce )as a mineral group name is put forth by the authors . Finally a new type of twinning of huanghoite-(Ce ) was found on the systematical absence of diffraction data by means of a single crystal diffractometer .展开更多
Laser-driven ultrafast X-ray sources are widely used for diagnostic radiography. However, there is a large divergence of fast electrons when they are generated by an intense short-pulse laser interacting with a foil t...Laser-driven ultrafast X-ray sources are widely used for diagnostic radiography. However, there is a large divergence of fast electrons when they are generated by an intense short-pulse laser interacting with a foil target. We design a nanowire array target to achieve a more compact point X-ray source. Fast electrons are confined and guided by the nanowire array structure in order to generate a Kα source with a small spot size. In our work, the smallest measured source size is comparable to the laser spot size, while the conversion efficiency can reach 2.4 ×10^-4.展开更多
The launderability of wool fabrics treated by nano finoshing agent influences directly the functional endurance of he treated wool fabric. In order to investigate the effect of wool fibers surface modification on the ...The launderability of wool fabrics treated by nano finoshing agent influences directly the functional endurance of he treated wool fabric. In order to investigate the effect of wool fibers surface modification on the functional erdurance of nano finishinp wool fibers, in this paper, for the first time wool fibers were chemically modified by using NaClO aqueous and KMnO4 aqueous, and then chemically modified wool fibers and native wool fibers were treated using nano ZnO finishing agent, respectively. The launderability of wool fibers treated by nano finishing agent was investigated. The experimental results show that the chemically modified wool fibers have a good launderaility after being treated by nano ZnO finishing agent treating. The surface morphologies of wool fibers were observed by using SEM. It is got that there is a strong adbesion between nano ZnO and wool surface through XPS analysis.展开更多
Objectives To compare the different patterns of coronary artery calcification (CAC) in acute and chronic coronary syndromes utilizing electron beam computed tomography. Background Pathologic, angiographic, and intraco...Objectives To compare the different patterns of coronary artery calcification (CAC) in acute and chronic coronary syndromes utilizing electron beam computed tomography. Background Pathologic, angiographic, and intracoronary ultrasound studies revealed sharp differences in the plaque morphology between patients with acute versus chronic coronary syndromes. Whether there are different patterns of coronary artery calcification in patients with stable angina pectoris (SAP) and in those with unstable angina pectoris (UAP) or acute myocardial infarction (AMI), however, remains unclear. Methods Two hundred and sixty - four patients, including 67 with SAP, 94 with UAP and 103 with AMI were studied with electron beam computed tomography for analysis of coronary artery calcification and with selective coronary angiography for determination of atherosclerotic lesions. CAC prevalence and calcium score were compared among three groups, and relation of CAC to the severity of atherosclerotic disease in the SAP and UAP patients was separately analyzed. Results Prevalence of CAC was 100 % in the SAP patients, significantly higher than the 87. 23 % in UAP patients and 86. 41 % among the patients with AMI ( P < 0. 05) . More patients and arteries in the SAP group had severe forms of calcium than those in the UAP and AMI group ( P < 0. 01), and the mean LN [CS + 1] (natural logarithm transformation of calcium score) of the SAP patients was much greater than that of the UAP and AMI patients (P < 0.001). The distribution of vessels with various CAC by luminal stenosis was different between SAP and UAP patients. The average CAC extent of the infarct - related arteries was less severe than that of the noninfarct - related arteries. Conclusions U-tilizing electron beam computed tomography, we demonstrated that there exist different patterns of coronary artery calcification in patients with acute versus chronic coronary syndromes, which may provide insight into the differences observed in the clinical and pathologic development between these two types of coronary artery disease.展开更多
Through the use of time and space integrated kiloelectronvolt (keV) spectroscopy, we investigate the thermal emission of plasma, which produces strong line emission from the titanium K shell (He-a at 4.7 keV and H-...Through the use of time and space integrated kiloelectronvolt (keV) spectroscopy, we investigate the thermal emission of plasma, which produces strong line emission from the titanium K shell (He-a at 4.7 keV and H-α at 4.9 keV), created by laser. In order to optimize the conversion efficiency enhancement on titanium foils, the experiment is conducted under a variety of laser-driven intensity conditions. The X-ray emission intensity at 4.7 keV is measured and compared with prediction. The experimental result demonstrates that the solid Ti target laser-produced plasma (LPP) source has X-ray emission at 4.7 keV, which are all generated from electronic transitions in Ti ions at pulse width of 2.1 ns or 30 ps, the crudely evaluated He-α X-ray intensity appears to slightly increase with laser intensity enhancement, and the pre- pulse effect increases the conversion efficiency of the He-α X-ray. In addition, a 90-μm-thick Ti foil as a filter is used to transmit He-α X-ray at near 4.7 keV, creating a quasi-monochromatic transmission and greatly reducing the lower- and higher-energy background.展开更多
文摘A primary study on Processing in X - ray inspection of spot weld for aluminum alloy spot welding,in- cluding for background simulation,acquisition of ideal binary image, and extraction and identifi- cation of defect features was presented.
基金supported by the National Natural Science Foundation of China under Grant No.10576041
文摘A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5-0.9 nm range. A large open aperture (30 ×20 (mm)) mica (002) spherically bent crystal with curvature radius R = 380 mm is used as dispersive and focusing element. The imaging plate is employed to obtain high spectral resolution with effective area of 30 × 80 (mm). The long designed path of the X-ray spectrometer beam is 980 mm from the source to the detector via the crystal. Experiment is carried out at a 20-J laser facility. X-ray spectra in an absolute intensity scale is obtained from Al laserproduced plasmas created by laser energy of 6.78 J. Samples of spectra obtained with spectral resolution of up to E/△E - 1500 are presented. The results clearly show that the device is good to diagnose laser high-density plasmas.
基金supported by the National Natural Science Foundation of China(Nos.11305116 and 11105098)the National Key Technology Support Program of China(No.2013BAK14B02)the National"973"Program of China(No.2011CB922203)
文摘A four-channel Kirkpatrick Baez microscope working at multiple energy bands is developed for multiframe X-ray imaging diagnostics at the Shenguang-II laser facility. The response to the multiple energy bands is realized by coating the double-periodic multilayers on the reflected surfaces of the microscope. Because of the limited size of the microstrips in the X-ray framing camera, the image separation is controlled by the coni- cal angle of the reference cores during microscope assembly. This study describes the optical and multilayer design, assembly, and aligmnent of the developed microscope. The microscope achieves a spatial resolution of 4 5 gin in the laboratory and 10 20 ~tm at Shenguang-II laser facility within a 300 tim field of view. The versatile nature of the developed microscope enables the multiple microscopes currently installed in the laser facility to be replaced with a single, multipurpose microscope.
基金supported by the National"973"Program of China(No.2011CB922203)the National Natural Science Foundation of China(Nos.11105098,11027507,and 11305116)the Scientific Research Plan Projects of the Science and Technology Commission of Shanghai(No.11nm0507200)
文摘A four-channel multilayer Kirkpatrick-Baez (KB) microscope is developed for the 8-keV X-ray imaging of experiments on laser inertial confinement fusion (ICF). A periodic multilayer that works at 8 keV and with a grazing incidence angle of 1.0~ is coated on reflective surfaces to achieve a spatial resolution higher than 5μm and an effective solid angle higher than 10-7 sr. A precise assembly is realized by a conical reference cone to couple with an X-ray framing camera. This study provides detailed information on an optical and multilayer design, assembly method, and experimental results with a Cu X-ray tube. The instrument provides a high-resolution and high-throughput X-ray image for backlit or self-emission imaging of laser plasma at Cu Kα line radiation in Shenguang series laser facilities.
基金the National Natural Science Foundation of China(Nos.11305116 and 11105098)the National Key Technology Support Program(No.2013BAK14B02)the National"973"Program ofChina(No.2011CB922203)
文摘A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility (SG-II). The microscope uses a total external reflection mirror in the sagittal direction and an array of multilayer mirrors in the tangential direction to obtain multiple individual high-resolution, high- throughput, and quasi-monochromatic X-ray images. The time evolution of the imploded target in multiple X-ray energy bands can be acquired when coupled with an X-ray streak camera. The experimental result of the time-resolved 2.5 and 3.0 keV dual-spectral self-emission imaging of the undoped CH shell target on SG-II is given.
文摘Microstructural change of YBaCuO film/YSZ substrate with and without proton irradiation has been studied by scanning electron microscope and X- ray diffraction techniques. Structural analysis has shown that conversion from tetragonal to orthorhombic phases, reduction of nonsuperconducting phase and preferential rearrangement of crystal grains are all favorable to the improvement of superconductivity in the YBaCuO film supported by YSZ substrate by proton beam bombardment.
文摘This paper summarizes the new developments in the study of barium rare-earth fluor-carbonate mineral structures .The second order superstructure of cebaite -(Ce ) was solved by using high power X-ray single crystal diffractometer . Five kinds of coordination forms were found . All atoms in the cell , including C and F , were properly located . In the process of study in a cordylite-(Ce ), a new mineral was discovered , whose chemical formula is (Ca0.5□0.5) BaCe2 (CO3)4F . It is isostructural with baiyuneboite - (Ce ), but different in composition (Na in baiyuneboite- (Ce ) is substituted by Ca disorderly ) . On the basis of the studies a proposal to re-define cordylite-(Ce )as a mineral group name is put forth by the authors . Finally a new type of twinning of huanghoite-(Ce ) was found on the systematical absence of diffraction data by means of a single crystal diffractometer .
基金supported by the National Science Foundation of China(Grant Nos.1174259,11175030,11475030,and10905051)the Science and Technology on Plasma Physics Laboratory(Grant No.9140c680306120c68253)the China Academy of Engineering Physics Foundation(Grant No.2011B0102021)
文摘Laser-driven ultrafast X-ray sources are widely used for diagnostic radiography. However, there is a large divergence of fast electrons when they are generated by an intense short-pulse laser interacting with a foil target. We design a nanowire array target to achieve a more compact point X-ray source. Fast electrons are confined and guided by the nanowire array structure in order to generate a Kα source with a small spot size. In our work, the smallest measured source size is comparable to the laser spot size, while the conversion efficiency can reach 2.4 ×10^-4.
文摘The launderability of wool fabrics treated by nano finoshing agent influences directly the functional endurance of he treated wool fabric. In order to investigate the effect of wool fibers surface modification on the functional erdurance of nano finishinp wool fibers, in this paper, for the first time wool fibers were chemically modified by using NaClO aqueous and KMnO4 aqueous, and then chemically modified wool fibers and native wool fibers were treated using nano ZnO finishing agent, respectively. The launderability of wool fibers treated by nano finishing agent was investigated. The experimental results show that the chemically modified wool fibers have a good launderaility after being treated by nano ZnO finishing agent treating. The surface morphologies of wool fibers were observed by using SEM. It is got that there is a strong adbesion between nano ZnO and wool surface through XPS analysis.
文摘Objectives To compare the different patterns of coronary artery calcification (CAC) in acute and chronic coronary syndromes utilizing electron beam computed tomography. Background Pathologic, angiographic, and intracoronary ultrasound studies revealed sharp differences in the plaque morphology between patients with acute versus chronic coronary syndromes. Whether there are different patterns of coronary artery calcification in patients with stable angina pectoris (SAP) and in those with unstable angina pectoris (UAP) or acute myocardial infarction (AMI), however, remains unclear. Methods Two hundred and sixty - four patients, including 67 with SAP, 94 with UAP and 103 with AMI were studied with electron beam computed tomography for analysis of coronary artery calcification and with selective coronary angiography for determination of atherosclerotic lesions. CAC prevalence and calcium score were compared among three groups, and relation of CAC to the severity of atherosclerotic disease in the SAP and UAP patients was separately analyzed. Results Prevalence of CAC was 100 % in the SAP patients, significantly higher than the 87. 23 % in UAP patients and 86. 41 % among the patients with AMI ( P < 0. 05) . More patients and arteries in the SAP group had severe forms of calcium than those in the UAP and AMI group ( P < 0. 01), and the mean LN [CS + 1] (natural logarithm transformation of calcium score) of the SAP patients was much greater than that of the UAP and AMI patients (P < 0.001). The distribution of vessels with various CAC by luminal stenosis was different between SAP and UAP patients. The average CAC extent of the infarct - related arteries was less severe than that of the noninfarct - related arteries. Conclusions U-tilizing electron beam computed tomography, we demonstrated that there exist different patterns of coronary artery calcification in patients with acute versus chronic coronary syndromes, which may provide insight into the differences observed in the clinical and pathologic development between these two types of coronary artery disease.
基金supported by the National "863" Program of China under Grant No. 2006AA804312
文摘Through the use of time and space integrated kiloelectronvolt (keV) spectroscopy, we investigate the thermal emission of plasma, which produces strong line emission from the titanium K shell (He-a at 4.7 keV and H-α at 4.9 keV), created by laser. In order to optimize the conversion efficiency enhancement on titanium foils, the experiment is conducted under a variety of laser-driven intensity conditions. The X-ray emission intensity at 4.7 keV is measured and compared with prediction. The experimental result demonstrates that the solid Ti target laser-produced plasma (LPP) source has X-ray emission at 4.7 keV, which are all generated from electronic transitions in Ti ions at pulse width of 2.1 ns or 30 ps, the crudely evaluated He-α X-ray intensity appears to slightly increase with laser intensity enhancement, and the pre- pulse effect increases the conversion efficiency of the He-α X-ray. In addition, a 90-μm-thick Ti foil as a filter is used to transmit He-α X-ray at near 4.7 keV, creating a quasi-monochromatic transmission and greatly reducing the lower- and higher-energy background.