Three long-term field trials in humid regions of Canada and the USA were used to evaluate the influence of soil depth and sample numbers on soil organic carbon (SOC) sequestration in no-tillage (NT) and moldboard plow...Three long-term field trials in humid regions of Canada and the USA were used to evaluate the influence of soil depth and sample numbers on soil organic carbon (SOC) sequestration in no-tillage (NT) and moldboard plow (MP) corn (Zea mays L.) and soybean (Glycine max L.) production systems. The first trial was conducted on a Maryhill silt loam (Typic Hapludalf) at Elora, Ontario, Canada, the second on a Brookston clay loam (Typic Argiaquoll) at Woodslee, Ontario, Canada, and the third on a Thorp silt loam (Argiaquic Argialboll) at Urbana, Illinois, USA. No-tillage led to significantly higher SOC concentrations in the top 5 cm compared to MP at all 3 sites. However, NT resulted in significantly lower SOC in sub-surface soils as compared to MP at Woodslee (10-20 cm, P = 0.01) and Urbana (20-30 cm, P < 0.10). No-tillage had significantly more SOC storage than MP at the Elora site (3.3 Mg C ha-1) and at the Woodslee site (6.2 Mg C ha-1) on an equivalent mass basis (1350 Mg ha-1 soil equivalent mass). Similarly, NT had greater SOC storage than MP at the Urbana site (2.7 Mg C ha-1) on an equivalent mass basis of 675 Mg ha-1 soil. However, these differences disappeared when the entire plow layer was evaluated for both the Woodslee and Urbana sites as a result of the higher SOC concentrations in MP than in NT at depth. Using the minimum detectable difference technique, we observed that up to 1500 soil sample per tillage treatment comparison will have to be collected and analyzed for the Elora and Woodslee sites and over 40 soil samples per tillage treatment comparison for the Urbana to statistically separate significant differences in the SOC contents of sub-plow depth soils. Therefore, it is impracticable, and at the least prohibitively expensive, to detect tillage-induced differences in soil C beyond the plow layer in various soils.展开更多
BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderat...BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderate to severe hypoxic-ischemic encephalopathy (HIE). OBJECTIVE: To observe the abnormal results of HIE at different degrees detected with BEAM and TCD in infant patients, and compare the detection results at the same time point between BEAM, TCD and computer tomography (CT) examinations. DESIGN : Contrast observation SETTING: Departments of Neuro-electrophysiology and Pediatrics, Second Affiliated Hospital of Qiqihar Medical College. PARTICIPANTS: Totally 416 infant patients with HIE who received treatment in the Department of Newborn Infants, Second Affiliated Hospital of Qiqihar Medical College during January 2001 and December 2005. The infant patients, 278 male and 138 female, were at embryonic 37 to 42 weeks and weighing 2.0 to 4.1 kg, and they were diagnosed with CT and met the diagnostic criteria of HIE of newborn infants compiled by Department of Neonatology, Pediatric Academy, Chinese Medical Association. According to diagnostic criteria, 130 patients were mild abnormal, 196 moderate abnormal and 90 severe abnormal. The relatives of all the infant patients were informed of the experiment. METHOOS: BEAM and TCD examinations were performed in the involved 416 infant patients with HIE at different degrees with DYD2000 16-channel BEAM instrument and EME-2000 ultrasonograph before preliminary diagnosis treatment (within 1 month after birth) and 1,3,6,12 and 24 months after birth, and detected results were compared between BEAM, TCD and CT examinations. MAIN OUTCOME MEASURES: Comparison of detection results of HIE at different time points in infant patients between BEAM. TCD and CT examinations. RESULTS: All the 416 infant patients with HIE participated in the result analysis. (1) Comparison of the detected results in infant patients with mild HIE at different time points after birth between BEAM, TCD and CT examinations: BEAM examination showed that the recovery was delayed, and the abnormal rate of BEAM examination was significantly higher than that of CT examination 1 and 3 months after birth [55.4%(72/130)vs. 17.0% (22/130 ),x^2=41.66 ;29.2% ( 38/130 ) vs. 6.2% ( 8/130 ), x^2=23.77, P 〈 0.01 ], exceptional patients had mild abnormality and reached the normal level in about 6 months. TCD examination showed that the disease condition significantly improved and infant patients with HIE basically recovered 1 or 2 months after birth, while CT examination showed that infant patients recovered 3 or 4 months after birth. (2) Comparison of detection results of infant patients with moderate HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination 1,3,6 and 12 months after birth [90.8% (178/196),78.6% (154/196),x^2=4.32,P 〈 0.05;64.3% (126/196),43.9% (86/196) ,x^2=16.44 ;44.9% (88/196) ,22.4% (44/196),x^2=22.11 ;21.4% (42/196), 10.2% (20/196),x^2=9.27, P 〈 0.01]. BEAM examination showed that there was still one patient who did not completely recovered in the 24^th month due to the relatives of infant patients did not combine the treatment,. TCD examination showed that the abnormal rate was 23.1%(30/196)in the 1^st month after birth, and all the patients recovered to the normal in the 3^rd month after birth, while CT examination showed that mild abnormality still existed in the 24^th month after birth (1.0% ,2/196). (3) Comparison of detection results of infant patients with severe HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination in the 1^st, 3^rd, 6^th and 12^th months after birth[86.7% (78/90),44.4% (40/90),x^2=35.53;62.2% (56/90),31.1% (28/90),x^2=17.51 ;37.8% (34/90),6.7% (6/90), x^2=27.14, P 〈 0.01]. BEAM examination showed that mild abnormality still existed in 4 infant patients in the 24^th month after birth. TCD examination showed that the abnormal rate was 11.1% (10/90) in the 3^rd month after birth, and all the infant patients recovered in the 6^th month after birth. CT examination showed that the abnormal rate was 6.7%(6/90) in the 12^th month after birth, and all of infant patients recovered to the normal in the 24^th month after birth.CONCLUSION : BEAM is the direct index to detect brain function of infant patients with HIE, and positive reaction is still very sensitive in the tracking detection of convalescent period. The positive rate of morphological reaction in CT examination is superior to that in TCD examination, and the positive rate is very high in the acute period of HIE in examination.展开更多
The NI (non-inferiority) trial design based on the likelihood ratio test eliminates the dependency on the conventional NI margin, and it explicitly uses the MCID (minimum clinical important difference) that links ...The NI (non-inferiority) trial design based on the likelihood ratio test eliminates the dependency on the conventional NI margin, and it explicitly uses the MCID (minimum clinical important difference) that links the statistical analysis to the clinical sense. Different from the conventional trial design, the new methodology is self-adaptive to the change in the sample size and overall cure rate, and it has an asymptotic property. It is shown that MCID is de-composite into constant MCID and statistical MCID. Along with this concept, the concept of the allowed inferiority does not exist, the interpretation of the trial result is more accurate and consistent to the statistical theory as well as the clinical interpretations.展开更多
Statistical power, number of replicates and experiment complexity of semi-field and field studies on Apis and non-Apis bee species has become a major issue after publication of the draft European Food Safety Authori...Statistical power, number of replicates and experiment complexity of semi-field and field studies on Apis and non-Apis bee species has become a major issue after publication of the draft European Food Safety Authority (EFSA) Guidance on risk assessment of plant protection products (PPP) on bees (Apis mellifera, Bombus spp. and solitary bees). According to this guidance document, field studies have to be designed to be able to detect significance differences as low as 7% for certain endpoints such as reduction in colony size. This will require an immense number of replicates which is obviously not feasible. In the present study, key endpoints such as mortality, termination rate and number of brood cells in honeybee studies, cocoon production and flight activity in solitary bee studies and number of gynes in bumble bee studies (just to mention some of the endpoints considered) in semi-field studies were analyzed, with Apis mellifera, Bombus terrestris and Osmia bicornis during the past five years (2013-2017). The results indicate huge differences in the percentage minimal detectable differences (%MDDs) (MDD expressed as median of control value of the endpoint in percent) depending on endpoint and species tested. For honeybee semi-field studies, the lowest %MDDs recorded were between 10% and 15% for the endpoints foraging, number of brood cells and colony strength. The highest %MDDs were observed for the endpoint termination rate, with a %MDD of almost 50%. For the endpoints in bumble bee semi-field studies the %MDDs varied between 17% for bumble bee colony weight and 53% for average mortality during the exposure period in the tunnel. The %MDD for the number of gynes (young queens) was slightly below 25%. For the semi-field solitary bee test system, the %MDDs for the measured endpoints seem to be lower than those for the other two species tested. The %MDDs for the endpoints hatching of offspring, nest occupation and number of cocoons were 8%, 13% and 14%, respectively. Most of the %MDDs were between 10% and 30% indicating clearly that the currently performed experimental design for the semi-field pollinator studies allowed to determine relatively small effects on key study endpoints. The analysis indicated that for all the three bee species tested, the semi-field test design detected low %MDDs for most of the endpoints. It was also observed that detectable differences between the control and PPP treatments were much lower in semi-field test designs than in field studies with these bee species. The “perfect sample size” really does not exist but test design and statistical analysis can be adapted to lower the %MDDs. Measured and simulated (according to Student’s t-test-distribution) data and results showed that statistical evaluations parameter selection (e.g., alpha value), data transformation (log10) and the number of replicates had a direct effect on the ability of the test design to detect lower or higher %MDD values. It could show that a change of alpha value from 0.05 to 0.1, increases the ability of the studies to detect lower %MDDs. For most of the measured endpoints, increasing the number of replicates e.g., from four to eight, improved the power of the test design by decreasing the %MDD. The reduction magnitude of the %MDD is dependent on the endpoint and selection of statistical parameters such as the alpha value. Parameters that display effects at a biologically relevant scale will be a better indicator for effects than parameters that are able to detect minor differences that are not biologically relevant.展开更多
According to the time&space conversion relations and different frequency phase detection principle,an ultra-high precision time&frequency measurement method is proposed in this paper.The higher accuracy and st...According to the time&space conversion relations and different frequency phase detection principle,an ultra-high precision time&frequency measurement method is proposed in this paper.The higher accuracy and stability of the speed of light and electromagnetic signals during the transmission in space or a specific medium enable the measurement of short time interval which uses the coincidence detection of signal’s transmission delay in length.The measurement precision better than 10 picoseconds can be easily obtained.The method develops the length vernier utilizing the stability of signal’s transmission delay,minimizes the fuzzy region of phase coincidence between the standard frequency signal and the measured signal,approaches the best phase coincidences and therefore improves the measurement precision which is higher than the precision provided by the traditional methods based on frequency processing.Besides,the method costs less than the traditional methods and can also solve the problem of the measurement of super-high frequency.Experimental results show the method can improve the measurement precision to 10 12/s in the time&frequency domain.展开更多
We report on the properties of strong pulses from PSR B0656+14 by analyzing the data obtained using the Urumqi 25-m radio telescope at 1540 MHz from August 2007 to September 2010.In 44 h of observational data,a total...We report on the properties of strong pulses from PSR B0656+14 by analyzing the data obtained using the Urumqi 25-m radio telescope at 1540 MHz from August 2007 to September 2010.In 44 h of observational data,a total of 67 pulses with signal-to-noise ratios above a 5σthreshold were detected.The peak flux densities of these pulses are 58 to 194 times that of the average profile,and their pulse energies are 3 to 68 times that of the average pulse.These pulses are clustered around phases about 5-ahead of the peak of the average profile.Compared with the width of the average profile,they are relatively narrow,with the full widths at half-maximum ranging from 0.28 ° to 1.78 °.The distribution of pulse-energies follows a lognormal distribution.These sporadic strong pulses detected from PSR B0656+14 have different characteristics from both typical giant pulses and its regular pulses.展开更多
文摘Three long-term field trials in humid regions of Canada and the USA were used to evaluate the influence of soil depth and sample numbers on soil organic carbon (SOC) sequestration in no-tillage (NT) and moldboard plow (MP) corn (Zea mays L.) and soybean (Glycine max L.) production systems. The first trial was conducted on a Maryhill silt loam (Typic Hapludalf) at Elora, Ontario, Canada, the second on a Brookston clay loam (Typic Argiaquoll) at Woodslee, Ontario, Canada, and the third on a Thorp silt loam (Argiaquic Argialboll) at Urbana, Illinois, USA. No-tillage led to significantly higher SOC concentrations in the top 5 cm compared to MP at all 3 sites. However, NT resulted in significantly lower SOC in sub-surface soils as compared to MP at Woodslee (10-20 cm, P = 0.01) and Urbana (20-30 cm, P < 0.10). No-tillage had significantly more SOC storage than MP at the Elora site (3.3 Mg C ha-1) and at the Woodslee site (6.2 Mg C ha-1) on an equivalent mass basis (1350 Mg ha-1 soil equivalent mass). Similarly, NT had greater SOC storage than MP at the Urbana site (2.7 Mg C ha-1) on an equivalent mass basis of 675 Mg ha-1 soil. However, these differences disappeared when the entire plow layer was evaluated for both the Woodslee and Urbana sites as a result of the higher SOC concentrations in MP than in NT at depth. Using the minimum detectable difference technique, we observed that up to 1500 soil sample per tillage treatment comparison will have to be collected and analyzed for the Elora and Woodslee sites and over 40 soil samples per tillage treatment comparison for the Urbana to statistically separate significant differences in the SOC contents of sub-plow depth soils. Therefore, it is impracticable, and at the least prohibitively expensive, to detect tillage-induced differences in soil C beyond the plow layer in various soils.
文摘BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderate to severe hypoxic-ischemic encephalopathy (HIE). OBJECTIVE: To observe the abnormal results of HIE at different degrees detected with BEAM and TCD in infant patients, and compare the detection results at the same time point between BEAM, TCD and computer tomography (CT) examinations. DESIGN : Contrast observation SETTING: Departments of Neuro-electrophysiology and Pediatrics, Second Affiliated Hospital of Qiqihar Medical College. PARTICIPANTS: Totally 416 infant patients with HIE who received treatment in the Department of Newborn Infants, Second Affiliated Hospital of Qiqihar Medical College during January 2001 and December 2005. The infant patients, 278 male and 138 female, were at embryonic 37 to 42 weeks and weighing 2.0 to 4.1 kg, and they were diagnosed with CT and met the diagnostic criteria of HIE of newborn infants compiled by Department of Neonatology, Pediatric Academy, Chinese Medical Association. According to diagnostic criteria, 130 patients were mild abnormal, 196 moderate abnormal and 90 severe abnormal. The relatives of all the infant patients were informed of the experiment. METHOOS: BEAM and TCD examinations were performed in the involved 416 infant patients with HIE at different degrees with DYD2000 16-channel BEAM instrument and EME-2000 ultrasonograph before preliminary diagnosis treatment (within 1 month after birth) and 1,3,6,12 and 24 months after birth, and detected results were compared between BEAM, TCD and CT examinations. MAIN OUTCOME MEASURES: Comparison of detection results of HIE at different time points in infant patients between BEAM. TCD and CT examinations. RESULTS: All the 416 infant patients with HIE participated in the result analysis. (1) Comparison of the detected results in infant patients with mild HIE at different time points after birth between BEAM, TCD and CT examinations: BEAM examination showed that the recovery was delayed, and the abnormal rate of BEAM examination was significantly higher than that of CT examination 1 and 3 months after birth [55.4%(72/130)vs. 17.0% (22/130 ),x^2=41.66 ;29.2% ( 38/130 ) vs. 6.2% ( 8/130 ), x^2=23.77, P 〈 0.01 ], exceptional patients had mild abnormality and reached the normal level in about 6 months. TCD examination showed that the disease condition significantly improved and infant patients with HIE basically recovered 1 or 2 months after birth, while CT examination showed that infant patients recovered 3 or 4 months after birth. (2) Comparison of detection results of infant patients with moderate HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination 1,3,6 and 12 months after birth [90.8% (178/196),78.6% (154/196),x^2=4.32,P 〈 0.05;64.3% (126/196),43.9% (86/196) ,x^2=16.44 ;44.9% (88/196) ,22.4% (44/196),x^2=22.11 ;21.4% (42/196), 10.2% (20/196),x^2=9.27, P 〈 0.01]. BEAM examination showed that there was still one patient who did not completely recovered in the 24^th month due to the relatives of infant patients did not combine the treatment,. TCD examination showed that the abnormal rate was 23.1%(30/196)in the 1^st month after birth, and all the patients recovered to the normal in the 3^rd month after birth, while CT examination showed that mild abnormality still existed in the 24^th month after birth (1.0% ,2/196). (3) Comparison of detection results of infant patients with severe HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination in the 1^st, 3^rd, 6^th and 12^th months after birth[86.7% (78/90),44.4% (40/90),x^2=35.53;62.2% (56/90),31.1% (28/90),x^2=17.51 ;37.8% (34/90),6.7% (6/90), x^2=27.14, P 〈 0.01]. BEAM examination showed that mild abnormality still existed in 4 infant patients in the 24^th month after birth. TCD examination showed that the abnormal rate was 11.1% (10/90) in the 3^rd month after birth, and all the infant patients recovered in the 6^th month after birth. CT examination showed that the abnormal rate was 6.7%(6/90) in the 12^th month after birth, and all of infant patients recovered to the normal in the 24^th month after birth.CONCLUSION : BEAM is the direct index to detect brain function of infant patients with HIE, and positive reaction is still very sensitive in the tracking detection of convalescent period. The positive rate of morphological reaction in CT examination is superior to that in TCD examination, and the positive rate is very high in the acute period of HIE in examination.
文摘The NI (non-inferiority) trial design based on the likelihood ratio test eliminates the dependency on the conventional NI margin, and it explicitly uses the MCID (minimum clinical important difference) that links the statistical analysis to the clinical sense. Different from the conventional trial design, the new methodology is self-adaptive to the change in the sample size and overall cure rate, and it has an asymptotic property. It is shown that MCID is de-composite into constant MCID and statistical MCID. Along with this concept, the concept of the allowed inferiority does not exist, the interpretation of the trial result is more accurate and consistent to the statistical theory as well as the clinical interpretations.
文摘Statistical power, number of replicates and experiment complexity of semi-field and field studies on Apis and non-Apis bee species has become a major issue after publication of the draft European Food Safety Authority (EFSA) Guidance on risk assessment of plant protection products (PPP) on bees (Apis mellifera, Bombus spp. and solitary bees). According to this guidance document, field studies have to be designed to be able to detect significance differences as low as 7% for certain endpoints such as reduction in colony size. This will require an immense number of replicates which is obviously not feasible. In the present study, key endpoints such as mortality, termination rate and number of brood cells in honeybee studies, cocoon production and flight activity in solitary bee studies and number of gynes in bumble bee studies (just to mention some of the endpoints considered) in semi-field studies were analyzed, with Apis mellifera, Bombus terrestris and Osmia bicornis during the past five years (2013-2017). The results indicate huge differences in the percentage minimal detectable differences (%MDDs) (MDD expressed as median of control value of the endpoint in percent) depending on endpoint and species tested. For honeybee semi-field studies, the lowest %MDDs recorded were between 10% and 15% for the endpoints foraging, number of brood cells and colony strength. The highest %MDDs were observed for the endpoint termination rate, with a %MDD of almost 50%. For the endpoints in bumble bee semi-field studies the %MDDs varied between 17% for bumble bee colony weight and 53% for average mortality during the exposure period in the tunnel. The %MDD for the number of gynes (young queens) was slightly below 25%. For the semi-field solitary bee test system, the %MDDs for the measured endpoints seem to be lower than those for the other two species tested. The %MDDs for the endpoints hatching of offspring, nest occupation and number of cocoons were 8%, 13% and 14%, respectively. Most of the %MDDs were between 10% and 30% indicating clearly that the currently performed experimental design for the semi-field pollinator studies allowed to determine relatively small effects on key study endpoints. The analysis indicated that for all the three bee species tested, the semi-field test design detected low %MDDs for most of the endpoints. It was also observed that detectable differences between the control and PPP treatments were much lower in semi-field test designs than in field studies with these bee species. The “perfect sample size” really does not exist but test design and statistical analysis can be adapted to lower the %MDDs. Measured and simulated (according to Student’s t-test-distribution) data and results showed that statistical evaluations parameter selection (e.g., alpha value), data transformation (log10) and the number of replicates had a direct effect on the ability of the test design to detect lower or higher %MDD values. It could show that a change of alpha value from 0.05 to 0.1, increases the ability of the studies to detect lower %MDDs. For most of the measured endpoints, increasing the number of replicates e.g., from four to eight, improved the power of the test design by decreasing the %MDD. The reduction magnitude of the %MDD is dependent on the endpoint and selection of statistical parameters such as the alpha value. Parameters that display effects at a biologically relevant scale will be a better indicator for effects than parameters that are able to detect minor differences that are not biologically relevant.
基金supported by the National Natural Science Foundation of China (Grant No. U1304618)the Open Fund of Key Laboratory of Precision Navigation and Timing Technology of Chinese Academy of Sciences(Grant No. 2012PNTT01)+5 种基金the Postdoctoral Grant of China (Grant Nos. 2011M501446, 2012T50798)the Basic and Advanced Technology Research Foundation of Henan Province under Grant (Grant No. 122300410169)The Key Science and Technology Foundation of Henan Province under Grant (Grant No. 132102210180)the Doctor Fund of Zhengzhou University of Light Industry under (Grant No. 2011BSJJ031)the Scientific Research Fund of Zhengzhou University of Light Industry under (Grant No. 2012XJJ009)the Fundamental Research Funds for the Central Universities(Grant No. K5051204003)
文摘According to the time&space conversion relations and different frequency phase detection principle,an ultra-high precision time&frequency measurement method is proposed in this paper.The higher accuracy and stability of the speed of light and electromagnetic signals during the transmission in space or a specific medium enable the measurement of short time interval which uses the coincidence detection of signal’s transmission delay in length.The measurement precision better than 10 picoseconds can be easily obtained.The method develops the length vernier utilizing the stability of signal’s transmission delay,minimizes the fuzzy region of phase coincidence between the standard frequency signal and the measured signal,approaches the best phase coincidences and therefore improves the measurement precision which is higher than the precision provided by the traditional methods based on frequency processing.Besides,the method costs less than the traditional methods and can also solve the problem of the measurement of super-high frequency.Experimental results show the method can improve the measurement precision to 10 12/s in the time&frequency domain.
基金funded by the National Natural Science Foundation of China(Grant No.10973026)
文摘We report on the properties of strong pulses from PSR B0656+14 by analyzing the data obtained using the Urumqi 25-m radio telescope at 1540 MHz from August 2007 to September 2010.In 44 h of observational data,a total of 67 pulses with signal-to-noise ratios above a 5σthreshold were detected.The peak flux densities of these pulses are 58 to 194 times that of the average profile,and their pulse energies are 3 to 68 times that of the average pulse.These pulses are clustered around phases about 5-ahead of the peak of the average profile.Compared with the width of the average profile,they are relatively narrow,with the full widths at half-maximum ranging from 0.28 ° to 1.78 °.The distribution of pulse-energies follows a lognormal distribution.These sporadic strong pulses detected from PSR B0656+14 have different characteristics from both typical giant pulses and its regular pulses.