With respect to sensitivity,selectivity and speed of operation,the current differential scheme is a better way to protect transmission lines than overcurrent and distance-based schemes.However,the protection scheme ca...With respect to sensitivity,selectivity and speed of operation,the current differential scheme is a better way to protect transmission lines than overcurrent and distance-based schemes.However,the protection scheme can be severely influenced by the Line Charging Capacitive Current(LCCC)with increased voltage level and Current Transformer(CT)saturation under external close-in faults.This paper presents a new UHV/EHV current-based protection scheme using the ratio of phasor summation of the two-end currents to the local end current,instead of summation of the two-end currents,to discriminate the internal faults.The accuracy and effectiveness of the proposed protection technique are tested on the 110 kV Western System Coordinating Council(WSCC)9-bus system using PSCAD/MATLAB.The simulation results confirm the reliable operation of the proposed scheme during internal/external faults and its independence from fault location,fault resistance,type of fault,and variations in source impedance.Finally,the effectiveness of the proposed scheme is also verified with faults during power swing and in series compensated lines.展开更多
The multi-terminal VSC-HVDC grid is believed to be widely applied in the future power system. The dc line protection is the key technique for operation security and power supply reliability of the dc grid. In this pap...The multi-terminal VSC-HVDC grid is believed to be widely applied in the future power system. The dc line protection is the key technique for operation security and power supply reliability of the dc grid. In this paper, the single-ended protections, namely, the traveling-wave based protection and transient-variable based protection, as well as the pilot protections, mainly including the directional pilot protection and current differential protection, are discussed in detail. With the analyzed protections, the effective main and back-up protection strategy can be configured for the dc line in multi-terminal VSC-HVDC grid.展开更多
Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which blocks th...Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which blocks the relay tripping during the transformer magnetizing inrush conditions. However, the backup overcurrent relay (SEL751A) applied to the transformer protection does not have harmonic restraint element and trip the overcurrent relay during the inrush conditions. Therefore, major contribution of this research work is the developed harmonic blocking scheme for transformer which uses element (87HB) of the transformer differential relay (SEL487E) to send an IEC61850 GOOSE-based harmonic blocking signal to the backup overcurrent relay (SEL751A) to inhibit from tripping during the transformer magnetizing inrush current conditions. The simulation results proved that IEC61850 standard-based protection scheme is faster than the hardwired signals. Therefore, the speed and reliability of the transformer scheme are improved using the IEC61850 standard-based GOOSE applications.展开更多
文摘With respect to sensitivity,selectivity and speed of operation,the current differential scheme is a better way to protect transmission lines than overcurrent and distance-based schemes.However,the protection scheme can be severely influenced by the Line Charging Capacitive Current(LCCC)with increased voltage level and Current Transformer(CT)saturation under external close-in faults.This paper presents a new UHV/EHV current-based protection scheme using the ratio of phasor summation of the two-end currents to the local end current,instead of summation of the two-end currents,to discriminate the internal faults.The accuracy and effectiveness of the proposed protection technique are tested on the 110 kV Western System Coordinating Council(WSCC)9-bus system using PSCAD/MATLAB.The simulation results confirm the reliable operation of the proposed scheme during internal/external faults and its independence from fault location,fault resistance,type of fault,and variations in source impedance.Finally,the effectiveness of the proposed scheme is also verified with faults during power swing and in series compensated lines.
基金supported by the National Natural Science Foundation of China(No.U1866205).
文摘The multi-terminal VSC-HVDC grid is believed to be widely applied in the future power system. The dc line protection is the key technique for operation security and power supply reliability of the dc grid. In this paper, the single-ended protections, namely, the traveling-wave based protection and transient-variable based protection, as well as the pilot protections, mainly including the directional pilot protection and current differential protection, are discussed in detail. With the analyzed protections, the effective main and back-up protection strategy can be configured for the dc line in multi-terminal VSC-HVDC grid.
基金funded by the National Research Foundation(NRF)THRIP grant TP2011061100004,ESKOM TESP(Capacitor Banks Placement)ESKOM Academy of Learning,ESKOM Power Plants Energy Institute(EPPEI)and CPUT(Prestigious Project)grant for the Centre of Substation Automation and Energy Management Systems(CSAEMS)development and growth.
文摘Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which blocks the relay tripping during the transformer magnetizing inrush conditions. However, the backup overcurrent relay (SEL751A) applied to the transformer protection does not have harmonic restraint element and trip the overcurrent relay during the inrush conditions. Therefore, major contribution of this research work is the developed harmonic blocking scheme for transformer which uses element (87HB) of the transformer differential relay (SEL487E) to send an IEC61850 GOOSE-based harmonic blocking signal to the backup overcurrent relay (SEL751A) to inhibit from tripping during the transformer magnetizing inrush current conditions. The simulation results proved that IEC61850 standard-based protection scheme is faster than the hardwired signals. Therefore, the speed and reliability of the transformer scheme are improved using the IEC61850 standard-based GOOSE applications.