Reliability of gas holdup measurements using the differential pressure method in a cyclone-static micro-bubble flotation column 被引量:1
1
作者 Xia Wencheng Yang Jianguo Wang Yuling 《Mining Science and Technology》 EI CAS 2011年第6期797-801,共5页
Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expans... Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expansion method. The errors were used to establish optimum measurement positions. The results show that the measurement position should be in the middle of the column and in the region half way from the center to the wall (the half-radius). The gas holdup along the axial direction is lower at the bottom and higher at the top of the floatation column. The gas holdup along the radial direction is lower near the wall and higher near the center of the flotation column. The average gas holdup measure- ment can be replaced by regional gas holdup values. 展开更多
关键词 Gas holdup distribution differential pressure method Measurement positions Axial direction Radial direction