For a 120 kW hydrogen fuel cell system,a centrifugal air compressor with fixed power of 22 kW fuel cell is designed.Firstly,the theoretical calculation is carried out for the aerodynamic characteristics of a ultra-hig...For a 120 kW hydrogen fuel cell system,a centrifugal air compressor with fixed power of 22 kW fuel cell is designed.Firstly,the theoretical calculation is carried out for the aerodynamic characteristics of a ultra-high-speed permanent magnet synchronous motor,an air compressor,and an aerodynamic foil bearing.Then,a prototype is trial-produced and a related test bench is built for test verification.Finally,both the simulation and test results indicate that the designed centrifugal air compressor meets the overall requirements of the hydrogen fuel cell system,and the relevant conclusions provide both theoretical and experimental references for the subsequent series development and design of the centrifugal air compressor.展开更多
In order to improve the design of PSA system for fuel cell hydrogen production,a non-isothermal model of eight-bed PSA hydrogen process with five-component(H_(2)/N_(2)/CH_(4)/CO/CO_(2)=74.59%/0.01%/4.2%/2.5%/18.7%(vol...In order to improve the design of PSA system for fuel cell hydrogen production,a non-isothermal model of eight-bed PSA hydrogen process with five-component(H_(2)/N_(2)/CH_(4)/CO/CO_(2)=74.59%/0.01%/4.2%/2.5%/18.7%(vol))four-stage pressure equalization was developed in this article.The model adopts a composite adsorption bed of activated carbon and zeolite 5 A.In this article,pressure variation,temperature field and separation performance are stimulated,and also effect of providing purge(PP)differential pressure and the ratio of activated carbon to zeolite 5 A on separation performance in the process of producing industrial hydrogen(CO content in hydrogen is 10μl·L^(-1))and fuel cell hydrogen(CO content is 0.2μl·L^(-1))are compared.The results show that Run 3,when the CO content in hydrogen is 10μl·L^(-1),the hydrogen recovery is 89.8%,and the average flow rate of feed gas is 0.529 mol·s^(-1);When the CO content in hydrogen is 0.2μl·L^(-1),the hydrogen recovery is 85.2%,and the average flow rate of feed gas is 0.43 mol·s^(-1).With the increase of PP differential pressure,hydrogen recovery first increases and then decreases,reaching the maximum when PP differential pressure is 0.263 MPa;With the decrease of the ratio of activated carbon to zeolite 5 A,the hydrogen recovery increases gradually.When the CO content in hydrogen is 0.2μl·L^(-1) the hydrogen recovery increases more obviously,from 83.96%to 86.37%,until the ratio of activated carbon to zeolite 5 A decreases to 1.At the end of PP step,no large amount of CO_(2) in gas or solid phase enters the zeolite 5 A adsorption bed,while when the CO content in hydrogen is 10μl·L^(-1),and the ratio of carbon to zeolite 5 A is less than 1.4,more CO_(2) will enter the zeolite 5 A bed.展开更多
The dynamic response of fuel cell vehicle is greatly affected by the pressure of reactants.Besides,the pressure difference between anode and cathode will also cause mechanical damage to proton exchange membrane.For ma...The dynamic response of fuel cell vehicle is greatly affected by the pressure of reactants.Besides,the pressure difference between anode and cathode will also cause mechanical damage to proton exchange membrane.For maintaining the relative stability of anode pressure,this study proposes a decentralized model predictive controller(DMPC)to control the anodic supply system composed of a feeding and returning ejector assembly.Considering the important influence of load current on the system,the piecewise linearization approach and state space with current-induced disturbance compensation are com-paratively analyzed.Then,an innovative switching strategy is proposed to prevent frequent switching of the sub-model-based controllers and to ensure the most appropriate predictive model is applied.Finally,simulation results demonstrate the better stability and robustness of the proposed control schemes compared with the traditional proportion integration differentia-tion controller under the step load current,variable target and purge disturbance conditions.In particular,in the case of the DC bus load current of a fuel cell hybrid vehicle,the DMPC controller with current-induced disturbance compensation has better stability and target tracking performance with an average error of 0.15 kPa and root mean square error of 1.07 kPa.展开更多
This paper proposes a rail pressure tracking controller based on a novel common rail system. A mathematical model, based on physical equations, is developed and used for feed forward control design. Rail pressure peak...This paper proposes a rail pressure tracking controller based on a novel common rail system. A mathematical model, based on physical equations, is developed and used for feed forward control design. Rail pressure peak sampling mechanism is designed to remove the disturbance of rail pressure due to fuel injection. An enhanced tracking differentiator is designed to get smooth tracking signal and exact differential signal from signal with noise. Double loop control strategy is designed to decouple the system and to improve dynamic performance of the system. Experimental results indicate that fluctuation of rail pressure is within ±1 MPa in steady condition, while within ±3 MPa in transient condition, which verifies the effectiveness of the proposed rail pressure control strategy.展开更多
基金supported in part by the Key R&D projects in Hebei Province under Grant 20312202D。
文摘For a 120 kW hydrogen fuel cell system,a centrifugal air compressor with fixed power of 22 kW fuel cell is designed.Firstly,the theoretical calculation is carried out for the aerodynamic characteristics of a ultra-high-speed permanent magnet synchronous motor,an air compressor,and an aerodynamic foil bearing.Then,a prototype is trial-produced and a related test bench is built for test verification.Finally,both the simulation and test results indicate that the designed centrifugal air compressor meets the overall requirements of the hydrogen fuel cell system,and the relevant conclusions provide both theoretical and experimental references for the subsequent series development and design of the centrifugal air compressor.
文摘In order to improve the design of PSA system for fuel cell hydrogen production,a non-isothermal model of eight-bed PSA hydrogen process with five-component(H_(2)/N_(2)/CH_(4)/CO/CO_(2)=74.59%/0.01%/4.2%/2.5%/18.7%(vol))four-stage pressure equalization was developed in this article.The model adopts a composite adsorption bed of activated carbon and zeolite 5 A.In this article,pressure variation,temperature field and separation performance are stimulated,and also effect of providing purge(PP)differential pressure and the ratio of activated carbon to zeolite 5 A on separation performance in the process of producing industrial hydrogen(CO content in hydrogen is 10μl·L^(-1))and fuel cell hydrogen(CO content is 0.2μl·L^(-1))are compared.The results show that Run 3,when the CO content in hydrogen is 10μl·L^(-1),the hydrogen recovery is 89.8%,and the average flow rate of feed gas is 0.529 mol·s^(-1);When the CO content in hydrogen is 0.2μl·L^(-1),the hydrogen recovery is 85.2%,and the average flow rate of feed gas is 0.43 mol·s^(-1).With the increase of PP differential pressure,hydrogen recovery first increases and then decreases,reaching the maximum when PP differential pressure is 0.263 MPa;With the decrease of the ratio of activated carbon to zeolite 5 A,the hydrogen recovery increases gradually.When the CO content in hydrogen is 0.2μl·L^(-1) the hydrogen recovery increases more obviously,from 83.96%to 86.37%,until the ratio of activated carbon to zeolite 5 A decreases to 1.At the end of PP step,no large amount of CO_(2) in gas or solid phase enters the zeolite 5 A adsorption bed,while when the CO content in hydrogen is 10μl·L^(-1),and the ratio of carbon to zeolite 5 A is less than 1.4,more CO_(2) will enter the zeolite 5 A bed.
基金supported in part by the Technological Innovation and Application Demonstration in Chongqing(Major Themes of Industry:cstc2019jscx-zdztzxX0033,cstc2019jscx-fxyd0158).
文摘The dynamic response of fuel cell vehicle is greatly affected by the pressure of reactants.Besides,the pressure difference between anode and cathode will also cause mechanical damage to proton exchange membrane.For maintaining the relative stability of anode pressure,this study proposes a decentralized model predictive controller(DMPC)to control the anodic supply system composed of a feeding and returning ejector assembly.Considering the important influence of load current on the system,the piecewise linearization approach and state space with current-induced disturbance compensation are com-paratively analyzed.Then,an innovative switching strategy is proposed to prevent frequent switching of the sub-model-based controllers and to ensure the most appropriate predictive model is applied.Finally,simulation results demonstrate the better stability and robustness of the proposed control schemes compared with the traditional proportion integration differentia-tion controller under the step load current,variable target and purge disturbance conditions.In particular,in the case of the DC bus load current of a fuel cell hybrid vehicle,the DMPC controller with current-induced disturbance compensation has better stability and target tracking performance with an average error of 0.15 kPa and root mean square error of 1.07 kPa.
基金the National Natural Science Foundation of China (No. 51179102)
文摘This paper proposes a rail pressure tracking controller based on a novel common rail system. A mathematical model, based on physical equations, is developed and used for feed forward control design. Rail pressure peak sampling mechanism is designed to remove the disturbance of rail pressure due to fuel injection. An enhanced tracking differentiator is designed to get smooth tracking signal and exact differential signal from signal with noise. Double loop control strategy is designed to decouple the system and to improve dynamic performance of the system. Experimental results indicate that fluctuation of rail pressure is within ±1 MPa in steady condition, while within ±3 MPa in transient condition, which verifies the effectiveness of the proposed rail pressure control strategy.