An electrochemical flow device has been developed for the determination of heavy metal ions(HMI)in water using multiwalled carbon nanotubes(MWCNTs)/Nafion(NA)/Hg electrode,by mean of diff erential pulse anodic strippi...An electrochemical flow device has been developed for the determination of heavy metal ions(HMI)in water using multiwalled carbon nanotubes(MWCNTs)/Nafion(NA)/Hg electrode,by mean of diff erential pulse anodic stripping voltammetry coupled with sequential injection analysis.The accuracy of the determination was ensured by the great electrical conductivity of MWCNTs and the high adsorption capacity of Hg.NA was used for MWCNTs immobilization for the long-term application of the electrode.The mercury film was cleaned after determination and another one would form during deposition.A lower limit of detection and a wider determination range of Cd^(2+)and Pb^(2+)could be achieved using the automatically analytical device combining with the MWCNTs/NA/Hg-modified electrode.The real-time monitoring of Cd^(2+)and Pb^(2+)in fresh water using this device continued for 10 days.The results indicated that the method was potential for on-site and real-time determination of HMI in water samples.展开更多
An electrochemical method for the simultaneous detection of two different DNA sequences from PAT and FMV 35S gene sequence using CdS and PbS quantum dots (QDs) as labels was described. The QDs were readily functiona...An electrochemical method for the simultaneous detection of two different DNA sequences from PAT and FMV 35S gene sequence using CdS and PbS quantum dots (QDs) as labels was described. The QDs were readily functionalized with oligonucleotides as electrochemical DNA probes and selectively hybridized to the complementary sequences immobilized on the microplate. The QDs anchored on the hybrids were dissolved in the solution by the oxidation of HNO3 and further detected by a sensitive differential pulse anodic stripping voltammetric method (DPASV). The DPASV signals of the oxidation of Cd^2+ and Pb^2+ ions present in the solution were different and reflected the identity of corresponding ssDNA targets sequences.展开更多
基金financially supported by the marine high-tech industry development projects of Fujian Province(No.2015-19)
文摘An electrochemical flow device has been developed for the determination of heavy metal ions(HMI)in water using multiwalled carbon nanotubes(MWCNTs)/Nafion(NA)/Hg electrode,by mean of diff erential pulse anodic stripping voltammetry coupled with sequential injection analysis.The accuracy of the determination was ensured by the great electrical conductivity of MWCNTs and the high adsorption capacity of Hg.NA was used for MWCNTs immobilization for the long-term application of the electrode.The mercury film was cleaned after determination and another one would form during deposition.A lower limit of detection and a wider determination range of Cd^(2+)and Pb^(2+)could be achieved using the automatically analytical device combining with the MWCNTs/NA/Hg-modified electrode.The real-time monitoring of Cd^(2+)and Pb^(2+)in fresh water using this device continued for 10 days.The results indicated that the method was potential for on-site and real-time determination of HMI in water samples.
基金the National Natural Science Foundation of China(Nos.20405008,20635020).
文摘An electrochemical method for the simultaneous detection of two different DNA sequences from PAT and FMV 35S gene sequence using CdS and PbS quantum dots (QDs) as labels was described. The QDs were readily functionalized with oligonucleotides as electrochemical DNA probes and selectively hybridized to the complementary sequences immobilized on the microplate. The QDs anchored on the hybrids were dissolved in the solution by the oxidation of HNO3 and further detected by a sensitive differential pulse anodic stripping voltammetric method (DPASV). The DPASV signals of the oxidation of Cd^2+ and Pb^2+ ions present in the solution were different and reflected the identity of corresponding ssDNA targets sequences.