A digital pulse analysis system is an important diagnostic system in nuclear physics experimental research.In response to the demand for reflecting the particle state in a nuclear physics experiment,we have designed a...A digital pulse analysis system is an important diagnostic system in nuclear physics experimental research.In response to the demand for reflecting the particle state in a nuclear physics experiment,we have designed and developed a real-time digital pulse analysis system and applied it to the digital nuclear pulse waveform discrimination of different detectors in the HL-2M tokamak.The system is based on the peripheral component interconnect extensions for instrumentation(PXI)platform,while its software was written in LABVIEW.The key technologies involved in the system implementation include digital pulse analysis technology,digital discrimination technology,pulse height analysis technology,etc.The system has been applied to the plastic scintillator detector at the Neutron Source Lab of the University of Science and Technology of China.And the experimental results indicate that the system can discriminate between neutron(n)particles and gamma(γ)particles well when used to measure the plastic scintillator detector.展开更多
A novel simple method based on pulse area analysis (PAA) is presented for acquisition of nuclear spectra by a digitizer. The PAA method can be used as a substitute for the traditional method of pulse height analysis...A novel simple method based on pulse area analysis (PAA) is presented for acquisition of nuclear spectra by a digitizer. The PAA method can be used as a substitute for the traditional method of pulse height analysis (PHA). In the PAA method a commercial digitizer was employed to sample and sum in the pulse, and the area of the pulse is proportional to the energy of the detected radiation. The results of simulation and experiment indicate the great advantages of the PAA method, especially as the count rate is high and the shaping time constant is small. When the shaping time constant is 0.5 μs, the energy resolution of PAA is about 66% better than that of PHA.展开更多
基金supported by National Natural Science Foundation of China (No. 1157518)
文摘A digital pulse analysis system is an important diagnostic system in nuclear physics experimental research.In response to the demand for reflecting the particle state in a nuclear physics experiment,we have designed and developed a real-time digital pulse analysis system and applied it to the digital nuclear pulse waveform discrimination of different detectors in the HL-2M tokamak.The system is based on the peripheral component interconnect extensions for instrumentation(PXI)platform,while its software was written in LABVIEW.The key technologies involved in the system implementation include digital pulse analysis technology,digital discrimination technology,pulse height analysis technology,etc.The system has been applied to the plastic scintillator detector at the Neutron Source Lab of the University of Science and Technology of China.And the experimental results indicate that the system can discriminate between neutron(n)particles and gamma(γ)particles well when used to measure the plastic scintillator detector.
基金Supported by National Natural Science Foundation of China(11375077,11027508)
文摘A novel simple method based on pulse area analysis (PAA) is presented for acquisition of nuclear spectra by a digitizer. The PAA method can be used as a substitute for the traditional method of pulse height analysis (PHA). In the PAA method a commercial digitizer was employed to sample and sum in the pulse, and the area of the pulse is proportional to the energy of the detected radiation. The results of simulation and experiment indicate the great advantages of the PAA method, especially as the count rate is high and the shaping time constant is small. When the shaping time constant is 0.5 μs, the energy resolution of PAA is about 66% better than that of PHA.