期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
A Portable Multi-functional Real-time Digital Simulator Dedicated to Protective Relay Testing
1
作者 Liang Zhicheng Ma Xiandong +1 位作者 Wang Haixian Wang Like (Nanjing Automation Research Institute (NARI)) 《Electricity》 1998年第4期27-29,共3页
The paper intfoduces a PC-DSP based real-time digital simulator which is portable in size and aimed at the closed-loop testing of various types of protective relays for their design and application. The simulator can ... The paper intfoduces a PC-DSP based real-time digital simulator which is portable in size and aimed at the closed-loop testing of various types of protective relays for their design and application. The simulator can be widely used in not only concerning utilities but also manufacturers and research / certification institutes because of its many functions. The hardware architecture and software implementation of the simulator are described. The main features and functions of the simulator are also 展开更多
关键词 TIME A Portable Multi-functional Real-time digital Simulator Dedicated to Protective relay Testing MMI
下载PDF
Microgrid dynamic security considering high penetration of renewable energy 被引量:6
2
作者 G.Magdy Emad A.Mohamed +2 位作者 G.Shabib Adel A.Elbaset Yasunori Mitani1 《Protection and Control of Modern Power Systems》 2018年第1期245-255,共11页
This paper presents a coordination strategy of Load Frequency Control(LFC)and digital frequency protection for an islanded microgrid(MG)considering high penetration of Renewable Energy Sources(RESs).In such MGs,the re... This paper presents a coordination strategy of Load Frequency Control(LFC)and digital frequency protection for an islanded microgrid(MG)considering high penetration of Renewable Energy Sources(RESs).In such MGs,the reduction in system inertia due to integration of large amount of RESs causes undesirable influence on MG frequency stability,leading to weakening of the MG.Furthermore,sudden load events,and short circuits caused large frequency fluctuations,which threaten the system security and could lead to complete blackouts as well as damages to the system equipment.Therefore,maintaining the dynamic security in MGs is one of the important challenges,which considered in this paper using a specific design and various data conversion stages of a digital over/under frequency relay(OUFR).The proposed relay will cover both under and over frequency conditions in coordination with LFC operation to protect the MG against high frequency variations.To prove the response of the proposed coordination strategy,a small MG was investigated for the simulation.The proposed coordination method has been tested considering load change,high integration of RESs.Moreover,the sensitivity analysis of the presented technique was examined by varying the penetration level of RESs and reducing the system inertia.The results reveal the effectiveness of the proposed coordination to maintain the power system frequency stability and security.In addition,the superiority of the OUFR has been approved in terms of accuracy and speed response during high disturbances. 展开更多
关键词 digital frequency relay Load frequency control(LFC) MICROGRID Renewable energy sources(RESs) DYNAMIC
原文传递
上一页 1 下一页 到第