期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Preparation, Crystal Structure and Properties of a New Crystal Form of Diammonium 5,5'-bistetrazole-1,1'-diolate 被引量:3
1
作者 Xiaojun Wang Shaohua Jin +3 位作者 Chunyuan Zhang Lijie Li Shusen Chen Qinghai Shu 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2015年第11期1229-1234,共6页
A new crystal form of diammonium 5,5'-bistetrazole-1,1'-diolate (1) was prepared by two novel methods and fully characterized by using IR, NMR spectroscopy, elementary analysis, single crystal X-ray crystallograph... A new crystal form of diammonium 5,5'-bistetrazole-1,1'-diolate (1) was prepared by two novel methods and fully characterized by using IR, NMR spectroscopy, elementary analysis, single crystal X-ray crystallography and thermal gravity/differential thermal analysis (TG/DTA). Crystalline 1 was found as monoclinic and space group of P21/c (14). The TG/DTA analysis showed that the decomposition temperature of 1 was 287.8℃ with a mass loss of 91.2% in the range of 220-300℃ at a heating rate of 5℃/min. The sensitivities test towards impact, friction of 1 indicated that 1 has much lower sensitivities than those of RDX/HMX and is comparable to those of TNT, which suggested that 1 could be used as a good candidate of new insensitive energetic compound. 展开更多
关键词 energetic material diammonium 5 5-bistetrazole-1 1-diolate crystal form thermal decomposition explosive performances
原文传递
Thermal hazard assessment of TKX-50-based melt-cast explosive 被引量:2
2
作者 Jun-feng Wang Shu-sen Chen +5 位作者 Shao-hua Jin Qing-hai Shu Feng-lei Huang Jian Ruan Xiao Ma Kun Chen 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第9期1546-1551,共6页
In the present study, thermal hazards of TNT and DNAN used as the molten binder in TKX-50-based meltcast explosives were comparatively studied through accelerating rate calorimeter(ARC) and Cook-off experiments. Two k... In the present study, thermal hazards of TNT and DNAN used as the molten binder in TKX-50-based meltcast explosives were comparatively studied through accelerating rate calorimeter(ARC) and Cook-off experiments. Two kinds of ARC operation modes were performed to investigate the thermal safety performance under adiabatic conditions(HWS mode) and constant heating(CHR mode). The obtained results demonstrated that at both heating modes, DNAN/TKX-50 outperformed TNT/TKX-50 from the thermal safety point of view. However, the sensitivity to heat of the samples was reverse because of the different heating modes. In addition, the results of thermal hazard assessment obtained from the cookoff experiment complied with ARC analysis which indicated the molten binder TNT replaced by DNAN would reduce the hazard of the TKX-50 melt cast explosive. Furthermore, the results of cook-off experiments also showed that DNAN/TKX-50 outperformed TNT/TKX-50 from the aspect of thermal stability, which was consistent with the result of CHR mode because of the similar heating process. 展开更多
关键词 Dihydroxylammonium 5 5’-bistetrazole-1 1’-diolate(TKX-50) 2 4-Dinitroanisole(DNAN) Thermal safety performance Accelerating rate calorimeter(ARC) Cook-off
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部