期刊文献+
共找到3,218篇文章
< 1 2 161 >
每页显示 20 50 100
Operation Performance of Central Solar Heating System with Seasonal Storage Water Tank in Harbin 被引量:2
1
作者 YE Ling1,JIANG Yi-qiang1,YAO Yang1,ZHANG Shi-cong2(1.Institute of Heat Pump and Air Conditioning Technology,Harbin Institute of Technology,Harbin,Heilongjiang 150090,China 2.Institute of Built Environment and Energy Efficiency,China Academy of Building Research,Beijing 100013,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期111-114,共4页
This paper presented a preliminary research on the central solar heating system with seasonal storage(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in t... This paper presented a preliminary research on the central solar heating system with seasonal storage(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in the central solar heating system was firstly developed based on energy conservation.This was followed by the simulation of the CSHSSS used in a two-floor villa in Harbin,and analysis of the impacts on storage water temperature of tank volume,solar collector area,tank burial depth,insulation thickness around the tank,etc.The results show there is a relatively economical tank volume to optimize the system efficiency,which decreases with increasing tank volume at the constant collector area,and increases with increasing collector area at the constant tank volume.Furthermore,the insulation thickness has obvious effect on avoiding heat loss,while the tank burial depth doesn't.In addition,the relationship between the solar collector efficiency and storage water temperature is also obtained,it decreases quickly with increasing storing water temperature,and then increases slowly after starting space heating system.These may be helpful for relevant design and optimization in cold climates in China and all over the world. 展开更多
关键词 CENTRAL solar heating SYSTEM with SEASONAL storage(CSHSSS) simulation SYSTEM efficiency STORAGE water tank VILLA
下载PDF
Attenuating water hammer pressure by means of gas storage tank 被引量:1
2
作者 韩文亮 韩军 +2 位作者 方红卫 邹伟生 夏建新 《中国有色金属学会会刊:英文版》 CSCD 2001年第3期438-443,共6页
The basic equations for computing the volume of gas storage tank were derived from the principles of attenuating water hammer pressure. Verifications using experiments indicate that the proposed equation can provide a... The basic equations for computing the volume of gas storage tank were derived from the principles of attenuating water hammer pressure. Verifications using experiments indicate that the proposed equation can provide a fare precision in the predictions. By using the model of solid liquid two phase flow, the gas storage tank, pressure relief valves and slow closure reverse control valves were compared with practical engineering problems, and the functions of gas storage tank in attenuating water hammer pressure were further investigated. [ 展开更多
关键词 water hammer pressure protective equipment gas storage tank water hammer model
下载PDF
Water-Tank Experiment on the Thermal Circulation Induced by the Bottom Heating in an Asymmetric Valley 被引量:1
3
作者 刘辉志 梁彬 +2 位作者 朱凤荣 张伯寅 桑建国 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2004年第4期536-546,共11页
Water tank experiments were carried out to investigate the thermal convection due to the bottom heating in an asymmetrical valley under neutral and stably stratified approach flows with the Particle Image Velometry (P... Water tank experiments were carried out to investigate the thermal convection due to the bottom heating in an asymmetrical valley under neutral and stably stratified approach flows with the Particle Image Velometry (PIV) visualization technique. In the neutral stratification approach flow, the ascending draft induced by bottom heating is mainly located in the center of the valley in calm ambient wind. However, with ambient wind flow, the thermal convection is shifted leeward, and the descending draft is located on the leeward side of the valley, while the ascending draft is located on the windward side. The descending draft is minorly turbulent and organized, while the ascending draft is highly turbulent. With the increase of the towing speed, the descending and ascending drafts induced by the mechanical elevation begin to play a more dominant role in the valley flow, while the role of the thermal convection in the valley airflow becomes limited. In the stable stratification approach flow, the thermal convection is limited by the stable stratification and no distinct circulation is formed in calm ambient wind. With ambient wind, agravity wave appears in the upper layer in the valley. With the increase of the ambient wind speed, a gravity wave plays an important role in the valley flow, and the location and intensity of the thermal convection are also modulated by the gravity internal waves. The thermal convection has difficulty penetrating the upper stable layer. Its exchange is limited between the air in the upper layer and that in the lower layer in the valley, and it is adverse to the diffusion of pollutants in the valley. 展开更多
关键词 thermal convection in a valley water tank experiment bottom heating
下载PDF
Impact of Untreated Sedimentation Tank Sludge Water Recycle on Water Quality During Treatment of Low Turbidity Water 被引量:1
4
作者 Ronggang Xu Yongpeng Xu +3 位作者 Fuyi Cui Li He Dong Wang Qingfeng Su 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2015年第4期79-86,共8页
The overall purpose of this research is to examine the impact of untreated sedimentation tank sludge water( USTSW) recycle on water quality during treatment of low turbidity water in coagulation—sedimentation process... The overall purpose of this research is to examine the impact of untreated sedimentation tank sludge water( USTSW) recycle on water quality during treatment of low turbidity water in coagulation—sedimentation processes. 950 m L of raw water and different concentrations of 50 m L USTSW are injected into six 1 000 m L beakers without coagulant.The results indicate that USTSW characterized as accumulated suspended solids and organic matter has active ingredients,which possess the equivalent function of coagulant. The optimal blended water turbidity is in the range of 10-20 NTU,within which USTSW recycle achieves the highest save coagulant rate. The mechanism of strengthening coagulation effect when USTSW recycle mainly depends on the chemical effect and physical effect. What is more,through scanning electron microscopy( SEM),it is found that the floc structures with USTSW recycle are more compact than those without USTSW recycle. Besides,the water quality parameters of color,NH3-N,CODMn,UV254,total aluminum,total manganese when USTSW recycle is better than the raw water without recycle,indicating that USTSW recycle can improve water quality with strengthening coagulation effect. 展开更多
关键词 untreated sedimentation tank sludge water recycle low turbidity optimal blended water turbidity water quality
下载PDF
Optimal operation of water supply systems with tanks based on genetic algorithm 被引量:6
5
作者 俞亭超 张土乔 李洵 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第8期886-893,共8页
In view of the poor water supply system’s network properties, the system’s complicated network hydraulic equations were replaced by macroscopic nodal pressure model and the model of relationship between supply flow ... In view of the poor water supply system’s network properties, the system’s complicated network hydraulic equations were replaced by macroscopic nodal pressure model and the model of relationship between supply flow and water source head. By using pump-station pressure head and initial tank water levels as decision variables, the model of optimal allocation of water supply between pump-sources was developed. Genetic algorithm was introduced to deal with the model of optimal allocation of water supply. Methods for handling each constraint condition were put forward, and overcome the shortcoming such as premature convergence of genetic algorithm; a solving method was brought forward in which genetic algorithm was combined with simulated annealing technology and self-adaptive crossover and mutation probabilities were adopted. An application example showed the feasibility of this algorithm. 展开更多
关键词 水供给系统 优化设计 遗传算法 网络控制 蓄水池
下载PDF
THE FREE BENDING VIBRATION OF CYLINDRICAL TANK PARTIALLY FILLED WITH-LIQUID AND SUBMERGED IN WATER 被引量:1
6
作者 周叮 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1990年第5期469-477,共9页
This paper studies the free bending vibration of cylindrical tank partially filled with liquid and submerged in water. The depths of liquid and water may be completely arbitrary. The exact calculating formulae of mode... This paper studies the free bending vibration of cylindrical tank partially filled with liquid and submerged in water. The depths of liquid and water may be completely arbitrary. The exact calculating formulae of mode shape functions and inherent frequencies are deduced. The results can be gained by means of computer. The analysis shows that the effect of liquid and water on vibration of cylindrical tank is respectively equivalent to a generalized distributive mass attached to the tank. 展开更多
关键词 mode THE FREE BENDING VIBRATION OF CYLINDRICAL tank PARTIALLY FILLED WITH-LIQUID AND SUBMERGED IN water
下载PDF
Water hammer protection for diversion systems in front of pumps in long-distance water supply projects 被引量:3
7
作者 Lin Shi Jian Zhang +3 位作者 Xiao-dong Yu Sheng Chen Wen-long Zhao Xu-yun Chen 《Water Science and Engineering》 EI CAS CSCD 2023年第2期211-218,共8页
For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention.... For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention. In this study, a water hammer protection scheme combined with an overflow surge tank and a regulating valve was developed. A mathematical model of the overflow surge tank was developed, and an analytical formula for the height of the overflow surge tank was derived. Furthermore, a practical water supply project was used to evaluate the feasibility of the combined protection scheme and analyze the sensitivity of valve regulation rules. The results showed that the combined protection scheme effectively reduced the height of the surge tank, lessened the difficulties related to construction, and reduced the necessary financial investment for the project. The two-stage closing rule articulated as fast first and then slow could minimize the overflow volume of the surge tank when the power failure occurred, while the two-stage opening rule articulated as slow first and then fast could be more conducive to the safety of the water supply system when the pump started up. 展开更多
关键词 Long-distance diversion pipeline water supply water hammer Overflow surge tank Regulating valve
下载PDF
Water Quality Variation of Malagane Tank:Lessons Learnt from Sustainable Ancient Hydraulic System,Sri Lanka
8
作者 Kushani Mahatantila Rohana Chandrajith H.A.H.Jayasena 《地学前缘》 EI CAS CSCD 北大核心 2009年第S1期240-240,共1页
Tank Cascade Systems(TCS)are the back bone of the dry zone prosperity in Sri Lanka and supply water throughout the year to agricultural lands since the 2nd century BC.The main aim of this study was to understand the n... Tank Cascade Systems(TCS)are the back bone of the dry zone prosperity in Sri Lanka and supply water throughout the year to agricultural lands since the 2nd century BC.The main aim of this study was to understand the nutrient dynamics of small TCS and find out evidence for the sustainability of the system for thousands of years.Malagane tank cascade in the Deduru Oya Basin(the 5th largest river basin 展开更多
关键词 tank Cascade System water quality CONSTRUCTED WETLAND SRI Lanka
下载PDF
Estimation of drift limits for different seismic damage states of RC frame staging in elevated water tanks using Park and Ang damage index
9
作者 Suraj O.Lakhade Ratnesh Kumar O.R.Jaiswal 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第1期161-177,共17页
Damage to elevated water tanks in past earthquakes can be attributed to the poor performance of their supporting frame staging. In order to ascertain the performance of these elevated water tanks, it is crucial to cat... Damage to elevated water tanks in past earthquakes can be attributed to the poor performance of their supporting frame staging. In order to ascertain the performance of these elevated water tanks, it is crucial to categorize the damage in quantifiable damage states. Among various parameters to quantify the damage states, the top drift of frame staging can be conveniently correlated to the different damage levels. In literature, drift limits corresponding to different damage states of the frame staging of the elevated water tank are not available. In the present study, drift limits for RC frame staging in elevated water tanks corresponding to different seismic damage states have been proposed. Various damage states of the elevated water tank have been determined using the Park and Ang damage index. The Park and Ang damage index utilizes results of both pushover analysis and incremental dynamic analysis. Twelve models of elevated water tanks have been developed considering variation in staging height and tank capacity. Incremental dynamic analysis has been performed using the suite of twelve actual earthquake ground motions. Based on the regression analysis between damage indexes and drift, limiting drift values for each damage state are proposed. 展开更多
关键词 elevated water tank frame staging damage states drift limit 3D modelling incremental dynamic analysis pushover analysis
下载PDF
Survey on Storage of Water for Domestic Use in Underground Reinforced Concrete Tanks: The Case of Brazzaville (Republic of Congo)
10
作者 Narcisse Malanda Paul Louzolo-Kimbembe 《Open Journal of Civil Engineering》 2014年第1期13-22,共10页
The problem of water supply from the public distribution network still poses very serious problems in many cities in developing countries. Intermittent water supply pushes some households to build underground reinforc... The problem of water supply from the public distribution network still poses very serious problems in many cities in developing countries. Intermittent water supply pushes some households to build underground reinforced concrete tanks for water storage to cope with unwanted water breaks. This study that relies on the results of a survey of households in some areas of the city of Brazzaville (Republic of Congo) aims to verify the importance that users attach to the quality of the works constructed. Indeed, the reliability of the tanks resulting in their impermeability to the external environment has a direct impact on the quality of stored water and therefore the use that is made of water daily. Five areas were selected because of their soil moisture. By 256 tanks identified, 143 are made of reinforced concrete and 113 in masonry. The coating materials used to seal the walls are preferably the earthenware tiles (64% of tanks), then the Sika cement (31%). Food painting (5%) is only rarely used. However, 66% of households are not assured of the potability of the water stored. A significant number of households (46%) think that the stored water could be contaminated with noxious substances seeping from the outside through the walls of the tanks. The issue of sealing of underground water tanks, especially in areas where the water table is shallow, seems concerned users. 展开更多
关键词 UNDERGROUND tanks watertightness Reinforced Concrete water STORAGE Potability Household
下载PDF
An Experiment on Releasing Water from Water Tanks by Xu Youzhen during the Ming Dynasty
11
作者 戴念祖 张旭敏 俞月圆(译) 《Chinese Annals of History of Science and Technology》 2017年第1期116-120,共5页
In 1453,Xu Youzhen,a scholar-bureaucrat and hydrologist in Ming China,was dispatched to Shandong to find a way to harness the Yellow River.He proposed the opening up of multiple channels to diverge the flood waters.An... In 1453,Xu Youzhen,a scholar-bureaucrat and hydrologist in Ming China,was dispatched to Shandong to find a way to harness the Yellow River.He proposed the opening up of multiple channels to diverge the flood waters.An experiment was conducted to compare the efficiency of releasing water using one large opening with the use of a number of small openings.This experiment proved that opening up multiple channels outperformed the construction of only one,thereby convincing the emperor and officials of the efficacy of this method.Xu’s method for water control proved to be successful in averting a flood that occurred in 1456. 展开更多
关键词 EXPERIMENT on RELEASING water from water tanks flood management hydromechanics Xu Youzhen Yellow RIVER
下载PDF
Life Cycle Assessment of Household Water Tanks—A Study of LLDPE, Mild Steel and RCC Tanks
12
作者 Kunal N. Shah Nanik S. Varandani Monika Panchani 《Journal of Environmental Protection》 2016年第5期760-769,共10页
A case of household water tanks, 1000 L capacity, made of RCC, LLDPE and mild steel (stainless steel) was evaluated for life cycle analysis. The scope of the research comprised of the raw materials, energy inputs and ... A case of household water tanks, 1000 L capacity, made of RCC, LLDPE and mild steel (stainless steel) was evaluated for life cycle analysis. The scope of the research comprised of the raw materials, energy inputs and corresponding emissions during all phases of product making such as extraction of raw material, it’s processing, followed by manufacturing and transport, as well as use and reuse of the product. Simapro 8 (System for Integrated environMental Assessment of PROducts), a modelling software, from Dutch PRé Consultants was used to conduct the life cycle analysis. Simapro 8 enables systematic and transparent modelling and analysis of complex life cycles based on the recommendations of the ISO 14040 series of standards. In the present study the most common method which is acceptable worldwide “Recipe Endpoint method” (ReCiPe) was employed. ReCiPe computes the impact categories and classifies them into two classes based on relevant arrays of characterization factors. Simapro addresses impact categories viz. ozone depletion, human toxicity, ionizing radiation, photochemical oxidant formation, particulate matter formation, terrestrial acidification, climate change, terrestrial ecotoxicity, agricultural land occupation, urban land occupation, natural land transformation, marine ecotoxicity, marine eutrophication, fresh water eutrophication, fresh water ecotoxicity, fossil fuel depletion, minerals depletion, fresh water depletion at the midpoint level. While at the Endpoint level, the impact categories are multiplied by corresponding damage factors and integrated to be represented as three Endpoint level categories, viz. human health, ecosystems and resource depletion. The three endpoint categories are normalized, weighted, and aggregated into a single score. LCA studies indicate that household water tanks of LLDPE have least environmental implications considering impacts on human health, ecosystems and resource depletion as compared to its counterparts viz. Household water tanks made up of mild steel and RCC. The sequence of the material with decreasing impacts is concrete tanks > mild steel tank > LLDPE tanks. The overall assessment is centred on the elements such as material inputs, energy inputs and environmental emissions. 展开更多
关键词 Life Cycle Assessment water tanks Linear Low-Density Polyethylene (LLDPE) RCC Mild Steel Recipe Endpoint Method
下载PDF
Cascade Tank Water Quality Management: A Case Study in Thirappane Tank Cascade System, Sri Lanka
13
作者 N.S.Abeysingha S.P.Dissanayake +1 位作者 S.Sumanaweera S.S.K.De Silva 《Journal of Environmental & Earth Sciences》 2021年第1期59-70,共12页
Tank cascade system(TCS)is a series of tanks located in a meso-catchment and has been accepted as a Globally Important Agricultural Heritage System found in Sri Lanka.Ecosystem components of the TCS play a major role ... Tank cascade system(TCS)is a series of tanks located in a meso-catchment and has been accepted as a Globally Important Agricultural Heritage System found in Sri Lanka.Ecosystem components of the TCS play a major role in purifying water within the system.This study attempted to investigate the water quality status and the farmers’willingness to rehabilitate the ecosystem components of the Thirappane TCS.Drinking and irrigation water quality parameters were tested in 34 locations and drinking and irrigation water quality indexes were calculated.Participatory rural appraisal and a questioner survey were conducted to gather social data.Water of TCS was observed to be appropriate for irrigation but not for drinking during the Maha cropping season.Based on the results of the Nitrate(as NO_(3)^(-))and Total Phosphate(as PO_(4)^(3-)),water of TCS can be categorized as eutrophic.Presence of ecosystem features of tank cascade system,annual income of the respondents,satisfaction on the quality of water for drinking,and the awareness about the tank cascade system significantly influenced the participatory decisions of the community on the rehabilitation of TCS.This study shall be an example and an eye opener to formulate sustainable tank cascade management plan. 展开更多
关键词 Drinking water quality Irrigation water quality Social survey tank cascade system watershed management
下载PDF
Seismic Response Improvement of Existing Prototype School Buildings Using Water Tanks, Port Said City, Egypt
14
作者 Batool Wahba Mohamed Sobaih Adel Akl 《Open Journal of Civil Engineering》 2016年第2期117-130,共14页
There is a global trend for seismic response improvement of new buildings to reduce cost and future damage. It is also important to improve existing structures that are designed without consideration of seismic load o... There is a global trend for seismic response improvement of new buildings to reduce cost and future damage. It is also important to improve existing structures that are designed without consideration of seismic load or using old provisions that cannot meet the new one. The objective of this paper is to draw attention to evaluate existing reinforced concrete school buildings, then to present a proposed methodology to improve the behaviour of such schools with low cost especially in a developing country. The proposed method uses overhead water tanks as a tuned mass damper. A pushover analysis has been performed to evaluate the existing schools and perform a feasibility study to select the best solution to achieve seismic response improvement of the existing structure. Of course, the proposed methodology can be applied easily to other existing structures. 展开更多
关键词 Existing Structures Tuned Mass damper (TMD) Seismic improvement Pushover Analysis water tank
下载PDF
Investigation on the Natural Modes of A Semi-Closed Floating Tank
15
作者 WANG Guo KONG Yao-hua +2 位作者 GE Jun-bo MA Yu-xiang SUN Lei 《China Ocean Engineering》 SCIE EI CSCD 2023年第4期580-587,共8页
Vessels with semi-closed tanks(i.e.,well docks)are widely applied in the military operation and maritime engineer-ing.The water is bound by the semi-closed floating tank and forced by both the incident waves and ship... Vessels with semi-closed tanks(i.e.,well docks)are widely applied in the military operation and maritime engineer-ing.The water is bound by the semi-closed floating tank and forced by both the incident waves and ship’s motions.The free surface oscillations inside the flooded well dock is thus distinctive and very complicated.So far,the natural modes of semi-closed floating tanks have not yet been studied.This paper investigates the characteristics of natural modes of a floating semi-closed tank by combining a mode-resolving model based on mild-slope equations and a hydrodynamic model based on computational fluid dynamics.Results show that the first three natural periods(i.e.,74,23.6,and 14 s)of the tank fall into the band of swell and infragravity waves and they could be triggered under certain circumstance.Multi-period free surface oscillations are observed inside the tank,including the longest natural period(i.e.,74 s),though the incident waves are monochromatic.A possible generation mechanism for the long-period mode is explained on the basis of liquid sloshing and harbor oscillations.Moreover,a long-period component with a period close to the natural mode of well dock is observed in the ship motions,which is generated by the interaction between the waves and ship. 展开更多
关键词 floating semi-closed tank water free surface oscillations natural period natural mode mild-slope equa-tions computational fluid dynamics
下载PDF
Thermo-Economic Performance of Geothermal Driven High-Temperature Flash Tank Vapor Injection Heat Pump System:A Comparison Study
16
作者 Huashan Li Xiaoshuang Zhao +2 位作者 Sihao Huang Lingbao Wang Jiongcong Chen 《Energy Engineering》 EI 2023年第8期1817-1835,共19页
Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is... Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price. 展开更多
关键词 Geothermal water high-temperature heat pump flash tank vapor injection thermo-economic performance
下载PDF
Influence of Ozone Injection on Corrosion Behavior of Steel in Water Ballast Tank
17
作者 Ryuji Kojima Michiaki Ikai +1 位作者 Jinsun Liao Yoichi Mori 《Journal of Shipping and Ocean Engineering》 2014年第11期327-337,共11页
关键词 臭氧浓度 腐蚀行为 压载水舱 注射液 水管理系统 活性物质 保护作用
下载PDF
水击补气式压力罐及水力瞬变仿真 被引量:1
18
作者 杨开林 《水利学报》 EI CSCD 北大核心 2024年第2期137-146,157,共11页
空气阀常常安装在输水管检修孔侧壁,进气后部分气体就会存留在检修孔上部产生气垫式压力罐的水击防护作用。据此,提出了水击补气式压力罐装置的设计方法,即利用泵站事故断电产生的水击负压现象,通过真空破坏阀或空气阀给压力罐补气,以... 空气阀常常安装在输水管检修孔侧壁,进气后部分气体就会存留在检修孔上部产生气垫式压力罐的水击防护作用。据此,提出了水击补气式压力罐装置的设计方法,即利用泵站事故断电产生的水击负压现象,通过真空破坏阀或空气阀给压力罐补气,以防止输水管发生液体汽化现象并削减水击最大压力。然后,建立了水击补气式压力罐水力瞬变数值仿真数学模型。最后,以一个实际输水工程为例,计算比较了分别设置空气阀、空气阀调压室及真空破坏阀补气式压力罐时的水击防护效果,结果表明,补气式压力罐水击防护效果最好。 展开更多
关键词 水击 空气阀 真空破坏阀 压力罐 补气 仿真
下载PDF
长距离输水泵站中空气罐参数敏感度分析及正交优化设计
19
作者 赵斌娟 曹可凡 +3 位作者 刘雨露 宋英南 陈汇龙 戴斌 《排灌机械工程学报》 CSCD 北大核心 2024年第3期243-249,共7页
为了探讨长距离输水泵站中空气罐的优化设计方法,以西北某长距离输水工程为例,以泵站水击最大正压水头和最小负压水头作为优化目标,以初始气体压力、高度直径比、连接管直径、进口阻力系数和出口阻力系数为优化变量,基于正交优化设计方... 为了探讨长距离输水泵站中空气罐的优化设计方法,以西北某长距离输水工程为例,以泵站水击最大正压水头和最小负压水头作为优化目标,以初始气体压力、高度直径比、连接管直径、进口阻力系数和出口阻力系数为优化变量,基于正交优化设计方法和KYPipe软件,采用极差分析法获得空气罐各参数对于水击最大正压水头和最小负压水头的影响,同时对得到的结果进行排序,比较并找到最优参数组合.结果表明:初始气体压力、连接管直径和出口阻力系数等因素对于水击最大正压水头和最小负压水头的影响程度较大,其中初始气体压力是最敏感的参数,对于最大正压水头和最小负压水头的影响程度最大;经过比较发现最优方案的参数组合为初始气体压力水头50 m、高度直径比4、连接管直径250 mm、进口阻力系数10、出口阻力系数5;相比原始方案,优化方案使泵站的水击最大正压水头降低4.98%、最小负压水头升高64.00%. 展开更多
关键词 空气罐 长距离输水泵站 水锤防护 敏感度分析 正交优化设计
下载PDF
多分水口长距离输水工程停泵水锤防护措施
20
作者 杨春霞 李倩 +3 位作者 马经童 郑源 耿魏强 张震 《排灌机械工程学报》 CSCD 北大核心 2024年第3期250-255,共6页
为了能够有效避免多泵且多分水口输水系统在无防护抽水断电时可能出现较为严重的负水锤带来的危害,建立了全长106.46 km的大型供水工程的数学模型进行系统过渡过程计算,选择空气阀与两阶段液控蝶阀联合防护与单向塔防护2种方案消除其负... 为了能够有效避免多泵且多分水口输水系统在无防护抽水断电时可能出现较为严重的负水锤带来的危害,建立了全长106.46 km的大型供水工程的数学模型进行系统过渡过程计算,选择空气阀与两阶段液控蝶阀联合防护与单向塔防护2种方案消除其负水锤,在前者远不达理想防护效果后针对后者进行优化.结合工程实际在确定了单向塔的数量、位置以及塔高后,对不同位置单向塔的底面积进行多种方案的对比选取,最终选用塔1#的底面积为28.26 m^(2),塔2#的底面积为176.63 m^(2);为了防止单向塔漏空需要分水口以及供水终端调流阀配合关闭,在确保管道最大压力不超出其承压能力的前提下,创新性地对各分水口调流阀与供水终端调流阀的关闭时间规律进行了效果比较,使输水系统能够更加经济安全地稳定运行,为此类长距离多分水口多泵供水工程的水锤防护提供了优化方向. 展开更多
关键词 单向调压塔 多分水口 负水锤 空气阀 关阀规律
下载PDF
上一页 1 2 161 下一页 到第
使用帮助 返回顶部