In order to effectively imitate the dynamic operation characteristics of the HVDC (high voltage direct current) power transmission system at a real ±500kV HVDC transmission project, the electromechanical-electr...In order to effectively imitate the dynamic operation characteristics of the HVDC (high voltage direct current) power transmission system at a real ±500kV HVDC transmission project, the electromechanical-electromagnetic transient hybrid simulation was carried out based on advanced digital power system simulator (ADPSS). In the simulation analysis, the built hybrid model's dynamic response outputs under three different fault conditions are considered, and by comparing with the selected fault recording waveforms, the validities of the simulation waveforms are estimated qualitatively. It can be ascertained that the hybrid simulation model has the ability to describe the HVDC system's dynamic change trends well under some special fault conditions.展开更多
Recently, introduction of renewable energy sources like wind power generation and photovoltaic power generation has been increasing from the viewpoint of environmental problems. However, renewable energy power supplie...Recently, introduction of renewable energy sources like wind power generation and photovoltaic power generation has been increasing from the viewpoint of environmental problems. However, renewable energy power supplies have unstable output due to the influence of weather conditions such as wind speed variations, which may cause fluctuations of voltage and frequency in the power system. This paper proposes fuzzy PD based virtual inertia control system to decrease frequency fluctuations in power system caused by fluctuating output of renewable energy sources. The proposed new method is based on the coordinated control of HVDC interconnection line and battery, and energy balancing control is also incorporated in it. Finally, it is concluded that the proposed system is very effective for suppressing the frequency fluctuations of the power system due to the large-scale wind power generation and solar power generation and also for keeping the energy balancing in the HVDC transmission line.展开更多
In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the outpu...In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the output becomes unstable because of intermittent characteristics, such as variations of wind speed or solar radiation intensity. Frequency fluctuations due to the installation of large scale wind farm (WF) and photovoltaics (PV) into the power system is a major concern. In order to solve the problem, this paper proposes two control methods using High Voltage Direct Current (HVDC) interconnection line to suppress the frequency fluctuations due to large scale of WF and PV. Comparative analysis between these two control methods is presented in this paper. One proposed method is a frequency control using a notch filter, and the other is using a deadband. Validity of the proposed methods is verified through simulation analyses, which is performed on a multi-machine power system model.展开更多
Co-ordination of directional over current relays(DOCR) requires the selection and setting of relays so as to sequentially isolate only that portion of the power system where an abnormality has occurred.The problem of ...Co-ordination of directional over current relays(DOCR) requires the selection and setting of relays so as to sequentially isolate only that portion of the power system where an abnormality has occurred.The problem of coordinating protective relays in electrical power systems consists of selecting suitable settings such that their fundamental protective function is met,given operational requirements of sensitivity,selectivity,reliability and speed.Directional over current relays are best suited for protection of an interconnected sub-station transmission system.One of the major problems associated with this type of protection is the difficulty in coordinating relays.To insure proper coordination,all the main/back up relay pairs must be determined.This paper presents an effective algorithm to determine the minimum number of break points and main/back up relay pairs using relative sequence matrix(RSM).A novel optimization technique based on evolutionary programming was developed using these main/back up relay pairs for directional over current relay coordination in multi-loop networks.Since the problem has multi-optimum points,conventional mathematics based optimization techniques may sometimes fail.Hence evolutionary programming(EP) was used,as it is a stochastic multi-point search optimization algorithm capable of escaping from the local optimum problem,giving a better chance of reaching a global optimum.The method developed was tested on an existing 6 bus,7 line system and better results were obtained than with conventional methods.展开更多
为解决船舶中压直流(medium voltage direct current,MVDC)电力系统直流电流开断困难,以及发生短路时故障电流上升率高且峰值大的问题,提出一种基于耦合电抗器的阻容限流型固态直流断路器拓扑。以晶闸管(silicon controlled rectifier,S...为解决船舶中压直流(medium voltage direct current,MVDC)电力系统直流电流开断困难,以及发生短路时故障电流上升率高且峰值大的问题,提出一种基于耦合电抗器的阻容限流型固态直流断路器拓扑。以晶闸管(silicon controlled rectifier,SCR)作为主开断器件,通过耦合电抗器来辅助晶闸管开断,并在直流系统发生故障时,通过换流过程将阻容限流元件接入,有效限制故障电流上升率和峰值,减少故障开断所需时间。基于所提拓扑设计了6 kV/4.2 kA的直流断路器模型,在PSCAD/EMTDC中进行仿真,并与现有拓扑进行对比分析。仿真结果表明:所设计断路器可针对直流系统不同的运行状态,按照不同的控制策略顺利完成对直流电流的开断,并且在开断速度、限流能力和金属氧化物避雷器(metal oxide arrester,MOA)耗能方面均具有一定优势。展开更多
高压直流输电系统嵌入大型交流系统,将进一步增加换相失败、直流闭锁等故障对系统安全稳定的影响,交流系统与直流系统的交互作用,将使系统动态更加复杂。针对电网不同运行方式下大扰动后系统复杂动态响应特性分析难题,文中提出一种基于...高压直流输电系统嵌入大型交流系统,将进一步增加换相失败、直流闭锁等故障对系统安全稳定的影响,交流系统与直流系统的交互作用,将使系统动态更加复杂。针对电网不同运行方式下大扰动后系统复杂动态响应特性分析难题,文中提出一种基于机电-电磁混合仿真与机器学习的智能分析方法。该方法基于主成分分析(principal components analysis,PCA)降维、基于密度的噪声应用空间聚类(density-based spatial clustering of applications with noise,DBSCAN)、K-means等算法建立二阶段聚类模型,可针对直流落点近区严重故障后大量混合仿真动态曲线在高维空间中自动聚类,并给出相应标识与严重程度;提取交直流系统在不同故障下的典型动态模式,自动标注并识别各模式下主导安全稳定问题。文中所提方法的有效性在2025年华东电网运行方式中得以验证,仿真结果表明,所提方法可有效提取不同故障下系统动态模式,将有效支撑后续复杂故障下的交直流系统动态机理分析。展开更多
基金supported by the General Program of Chinese Postdoctoral Science Foundation under Grant No.2012M511595
文摘In order to effectively imitate the dynamic operation characteristics of the HVDC (high voltage direct current) power transmission system at a real ±500kV HVDC transmission project, the electromechanical-electromagnetic transient hybrid simulation was carried out based on advanced digital power system simulator (ADPSS). In the simulation analysis, the built hybrid model's dynamic response outputs under three different fault conditions are considered, and by comparing with the selected fault recording waveforms, the validities of the simulation waveforms are estimated qualitatively. It can be ascertained that the hybrid simulation model has the ability to describe the HVDC system's dynamic change trends well under some special fault conditions.
文摘Recently, introduction of renewable energy sources like wind power generation and photovoltaic power generation has been increasing from the viewpoint of environmental problems. However, renewable energy power supplies have unstable output due to the influence of weather conditions such as wind speed variations, which may cause fluctuations of voltage and frequency in the power system. This paper proposes fuzzy PD based virtual inertia control system to decrease frequency fluctuations in power system caused by fluctuating output of renewable energy sources. The proposed new method is based on the coordinated control of HVDC interconnection line and battery, and energy balancing control is also incorporated in it. Finally, it is concluded that the proposed system is very effective for suppressing the frequency fluctuations of the power system due to the large-scale wind power generation and solar power generation and also for keeping the energy balancing in the HVDC transmission line.
文摘In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the output becomes unstable because of intermittent characteristics, such as variations of wind speed or solar radiation intensity. Frequency fluctuations due to the installation of large scale wind farm (WF) and photovoltaics (PV) into the power system is a major concern. In order to solve the problem, this paper proposes two control methods using High Voltage Direct Current (HVDC) interconnection line to suppress the frequency fluctuations due to large scale of WF and PV. Comparative analysis between these two control methods is presented in this paper. One proposed method is a frequency control using a notch filter, and the other is using a deadband. Validity of the proposed methods is verified through simulation analyses, which is performed on a multi-machine power system model.
文摘Co-ordination of directional over current relays(DOCR) requires the selection and setting of relays so as to sequentially isolate only that portion of the power system where an abnormality has occurred.The problem of coordinating protective relays in electrical power systems consists of selecting suitable settings such that their fundamental protective function is met,given operational requirements of sensitivity,selectivity,reliability and speed.Directional over current relays are best suited for protection of an interconnected sub-station transmission system.One of the major problems associated with this type of protection is the difficulty in coordinating relays.To insure proper coordination,all the main/back up relay pairs must be determined.This paper presents an effective algorithm to determine the minimum number of break points and main/back up relay pairs using relative sequence matrix(RSM).A novel optimization technique based on evolutionary programming was developed using these main/back up relay pairs for directional over current relay coordination in multi-loop networks.Since the problem has multi-optimum points,conventional mathematics based optimization techniques may sometimes fail.Hence evolutionary programming(EP) was used,as it is a stochastic multi-point search optimization algorithm capable of escaping from the local optimum problem,giving a better chance of reaching a global optimum.The method developed was tested on an existing 6 bus,7 line system and better results were obtained than with conventional methods.
文摘为解决船舶中压直流(medium voltage direct current,MVDC)电力系统直流电流开断困难,以及发生短路时故障电流上升率高且峰值大的问题,提出一种基于耦合电抗器的阻容限流型固态直流断路器拓扑。以晶闸管(silicon controlled rectifier,SCR)作为主开断器件,通过耦合电抗器来辅助晶闸管开断,并在直流系统发生故障时,通过换流过程将阻容限流元件接入,有效限制故障电流上升率和峰值,减少故障开断所需时间。基于所提拓扑设计了6 kV/4.2 kA的直流断路器模型,在PSCAD/EMTDC中进行仿真,并与现有拓扑进行对比分析。仿真结果表明:所设计断路器可针对直流系统不同的运行状态,按照不同的控制策略顺利完成对直流电流的开断,并且在开断速度、限流能力和金属氧化物避雷器(metal oxide arrester,MOA)耗能方面均具有一定优势。
文摘高压直流输电系统嵌入大型交流系统,将进一步增加换相失败、直流闭锁等故障对系统安全稳定的影响,交流系统与直流系统的交互作用,将使系统动态更加复杂。针对电网不同运行方式下大扰动后系统复杂动态响应特性分析难题,文中提出一种基于机电-电磁混合仿真与机器学习的智能分析方法。该方法基于主成分分析(principal components analysis,PCA)降维、基于密度的噪声应用空间聚类(density-based spatial clustering of applications with noise,DBSCAN)、K-means等算法建立二阶段聚类模型,可针对直流落点近区严重故障后大量混合仿真动态曲线在高维空间中自动聚类,并给出相应标识与严重程度;提取交直流系统在不同故障下的典型动态模式,自动标注并识别各模式下主导安全稳定问题。文中所提方法的有效性在2025年华东电网运行方式中得以验证,仿真结果表明,所提方法可有效提取不同故障下系统动态模式,将有效支撑后续复杂故障下的交直流系统动态机理分析。