期刊文献+
共找到1,410篇文章
< 1 2 71 >
每页显示 20 50 100
Winding Function Model-based Performance Evaluation of a PM Transverse Flux Generator for Applications in Direct-drive Systems
1
作者 Mehrage Ghods Jawad Faiz Ali A Pourmoosa 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期216-226,共11页
The magnetic flux in a permanent magnet transverse flux generator(PMTFG) is three-dimensional(3D), therefore, its efficacy is evaluated using 3D magnetic field analysis. Although the 3D finite-element method(FEM) is h... The magnetic flux in a permanent magnet transverse flux generator(PMTFG) is three-dimensional(3D), therefore, its efficacy is evaluated using 3D magnetic field analysis. Although the 3D finite-element method(FEM) is highly accurate and reliable for machine simulation, it requires a long computation time, which is crucial when it is to be used in an iterative optimization process. Therefore, an alternative to 3DFEM is required as a rapid and accurate analytical technique. This paper presents an analytical model for PMTFG analysis using winding function method. To obtain the air gap MMF distribution, the excitation magneto-motive force(MMF) and the turn function are determined based on certain assumptions. The magnetizing inductance, flux density, and back-electro-magnetomotive force of the winding are then determined. To assess the accuracy of the proposed method, the analytically calculated parameters of the generator are compared to those obtained by a 3D-FEM. The presented method requires significantly shorter computation time than the 3D-FEM with comparable accuracy. 展开更多
关键词 Index Terms—permanent magnet transverse flux generator winding function 3D-FEM Cogging torque PROTOTYPING
下载PDF
A Novel Open-winding Permanent Magnetic Starter-generator 被引量:13
2
作者 魏佳丹 周波 +3 位作者 韩楚 邓清唐 史明明 刘颖 《中国电机工程学报》 EI CSCD 北大核心 2011年第36期I0008-I0008,243,共1页
针对永磁电机应用于车载起动/发电系统时存在的电压调节困难、适用转速范围窄、功率因数较低等问题,提出一种新型永磁车载起动/发电系统。通过引入绕组开路型永磁电机,绕组一端接整流桥形成输出直流侧,另一端接逆变桥形成控制端,... 针对永磁电机应用于车载起动/发电系统时存在的电压调节困难、适用转速范围窄、功率因数较低等问题,提出一种新型永磁车载起动/发电系统。通过引入绕组开路型永磁电机,绕组一端接整流桥形成输出直流侧,另一端接逆变桥形成控制端,构成具有宽转速范围和高效率的永磁电机起动/发电系统。分析该系统的起动、发电一体化工作原理,给出了通过逆变侧变换器实现发电机电压、电流控制的方案。仿真和实验结果表明,该新型车载起动/发电系统具有优良的发电调压控制性能,并且适应较宽的转速范围。 展开更多
关键词 永磁起动机 永磁发电机 开放式 绕组 起动发电机 电压调节 功率因数 生成模式
下载PDF
Design Optimization of a Self-circulated Hydrogen Cooling System for a PM Wind Generator Based on Taguchi Method
3
作者 Gaojia Zhu Yunhao Li Longnv Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期170-176,共7页
With the continuous improvement of permanent magnet(PM)wind generators'capacity and power density,the design of reasonable and efficient cooling structures has become a focus.This paper proposes a fully enclosed s... With the continuous improvement of permanent magnet(PM)wind generators'capacity and power density,the design of reasonable and efficient cooling structures has become a focus.This paper proposes a fully enclosed self-circulating hydrogen cooling structure for a originally forced-air-cooled direct-drive PM wind generator.The proposed hydrogen cooling system uses the rotor panel supports that hold the rotor core as the radial blades,and the hydrogen flow is driven by the rotating plates to flow through the axial and radial vents to realize the efficient cooling of the generator.According to the structural parameters of the cooling system,the Taguchi method is used to decouple the structural variables.The influence of the size of each cooling structure on the heat dissipation characteristic is analyzed,and the appropriate cooling structure scheme is determined. 展开更多
关键词 permanent magnet wind generator Hydrogen cooling Taguchi method Fluidic-thermal coupled fields
下载PDF
Maximum Power Point Tracking in Variable Speed Wind Turbine Based on Permanent Magnet Synchronous Generator Using Maximum Torque Sliding Mode Control Strategy 被引量:3
4
作者 Esmaeil Ghaderi Hossein Tohidi Behnam Khosrozadeh 《Journal of Electronic Science and Technology》 CAS CSCD 2017年第4期391-399,共9页
The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, th... The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, the rotor speed is set at an optimal point for different wind speeds. As a result of which, the tip speed ratio reaches an optimal point, mechanical power coefficient is maximized, and wind turbine produces its maximum power and mechanical torque. Then, the maximum mechanical torque is tracked using electromechanical torque. In this technique, tracking error integral of maximum mechanical torque, the error, and the derivative of error are used as state variables. During changes in wind speed, sliding mode control is designed to absorb the maximum energy from the wind and minimize the response time of maximum power point tracking(MPPT). In this method, the actual control input signal is formed from a second order integral operation of the original sliding mode control input signal. The result of the second order integral in this model includes control signal integrity, full chattering attenuation, and prevention from large fluctuations in the power generator output. The simulation results, calculated by using MATLAB/m-file software, have shown the effectiveness of the proposed control strategy for wind energy systems based on the permanent magnet synchronous generator(PMSG). 展开更多
关键词 Maximum power point tracking permanent magnet synchronous generator(PMSG) sliding mode control wind turbine
下载PDF
Performance analysis of 20 Pole 1.5 KW Three Phase Permanent Magnet Synchronous Generator for low Speed Vertical Axis Wind Turbine 被引量:2
5
作者 Shahrukh Adnan Khan Rajprasad K. Rajkumar +1 位作者 Rajparthiban K. Rajkumar Aravind CV 《Energy and Power Engineering》 2013年第4期423-428,共6页
This paper gives performance analysis of a three phase Permanent Magnet Synchronous Generator (PMSG) connected to a Vertical Axis Wind Turbine (VAWT). Low speed wind condition (less than 5 m/s) is taken in considerati... This paper gives performance analysis of a three phase Permanent Magnet Synchronous Generator (PMSG) connected to a Vertical Axis Wind Turbine (VAWT). Low speed wind condition (less than 5 m/s) is taken in consideration and the entire simulation is carried in Matlab/Simulink environment. The rated power for the generator is fixed at 1.5 KW and number of pole at 20. It is observed under low wind speed of6 m/s, a turbine having approximately1 mof radius and2.6 mof height develops 150 Nm mechanical torque that can generate power up to 1.5 KW. The generator is designed using modeling tool and is fabricated. The fabricated generator is tested in the laboratory with the simulation result for the error analysis. The range of error is about 5%-27% for the same output power value. The limitations and possible causes for error are presented and discussed. 展开更多
关键词 Vertical Axis wind TURBINE Three Phase Multi-pole permanent magnet SYNCHRONOUS generator Low wind Speed Modeling Performance Analysis
下载PDF
An Improved Stator Flux Observation Method of Permanent Magnet Synchronous Motor 被引量:1
6
作者 Guangjing Su Hongmei Li +1 位作者 Ying Dai Zheng Li 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2016年第6期90-96,共7页
The stator flux and electromagnetic torque observation is the basis of direct torque controlled permanent magnet synchronous motor( PMSM) drive system. However,the traditional stator flux observer based on voltage mod... The stator flux and electromagnetic torque observation is the basis of direct torque controlled permanent magnet synchronous motor( PMSM) drive system. However,the traditional stator flux observer based on voltage model is affected by integral initial values and integral drift,that based on current model is affected by the parameters of PMSM,so a new stator flux observation method is proposed based on an improved secondorder generalized integrator( SOGI). Compared to the stator flux observation method based on the conventional SOGI,the proposed method can not only overcome the influence of integral initial values and integral drift,but also completely eliminate the DC offset's influence. Therefore,the observation accuracy of stator flux is further improved. The simulation and experimental results both show that the proposed method has a higher stator flux and electromagnetic torque observation precision. 展开更多
关键词 permanent magnet synchronous motor direct torque control second-order generalized integrator stator flux observation electromagnetic torque observation
下载PDF
Comparative Performance of Fixed-Speed and Variable-Speed Wind Turbine Generator Systems 被引量:2
7
作者 Mohamed Mansour Mohamed Nejib Mansouri Mohamed Faouzi Mimouni 《Journal of Mechanics Engineering and Automation》 2011年第1期74-81,共8页
In the early development of the wind energy, the majority of the wind turbines have been operated at constant speed. Subsequently, the number of variable-speed wind turbines installed in wind farms has increased. In t... In the early development of the wind energy, the majority of the wind turbines have been operated at constant speed. Subsequently, the number of variable-speed wind turbines installed in wind farms has increased. In this paper, a comparative performance of fixed and variable speed wind generators with Pitch angle control has been presented. The first is based on a squirrel cage Induction Generator (IG) of 315 kW rated power, connected directly to the grid. The second incorporated a Permanent Magnet Synchronous Generator (PMSG) of 750 kW rated power. The performances of each studied wind generator are evaluated by simulation works and variable speed operation is highlighted as preferred mode of operation. 展开更多
关键词 Fixed speed wind generator variable speed wind generator squirrel cage induction generator permanent magnet synchronous generator (PMSG) maximum power point tracking (MPPT) pitch control.
下载PDF
Modularity Techniques in High Performance Permanent Magnet Machines and Applications 被引量:2
8
作者 Z.Q.Zhu Y.X.Li 《CES Transactions on Electrical Machines and Systems》 2018年第1期93-103,共11页
This paper reviews the modularity techniques in the stator manufacture of permanent magnet machines for different applications.Some basic concepts of modular machines are firstly introduced.Modular machines for severa... This paper reviews the modularity techniques in the stator manufacture of permanent magnet machines for different applications.Some basic concepts of modular machines are firstly introduced.Modular machines for several typical applications are then described in details,including domestic appliances,automobiles and electric vehicles,more electric aircrafts and civic applications,wind power generators,etc.Besides,the influence of manufacture tolerance gaps and flux barriers on the electromagnetic performance is discussed. 展开更多
关键词 Domestic appliance electric vehicle(EV) modular machine more electric aircraft permanent magnet wind power generator
下载PDF
Integrated Equivalent Model of Permanent Magnet Synchronous Generator Based Wind Turbine for Large-scale Offshore Wind Farm Simulation 被引量:2
9
作者 Ming Zou Yan Wang +3 位作者 Chengyong Zhao Jianzhong Xu Xiaojiang Guo Xu Sun 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第5期1415-1426,共12页
The high-speed simulation of large-scale offshore wind farms(OWFs) preserving the internal machine information has become a huge challenge due to the large wind turbine(WT) count and microsecond-range time step. Hence... The high-speed simulation of large-scale offshore wind farms(OWFs) preserving the internal machine information has become a huge challenge due to the large wind turbine(WT) count and microsecond-range time step. Hence, it is undoable to investigate the internal node information of the OWF in the electro-magnetic transient(EMT) programs. To fill this gap,this paper presents an equivalent modeling method for largescale OWF, whose accuracy and efficiency are guaranteed by integrating the individual devices of permanent magnet synchronous generator(PMSG) based WT. The node-elimination algorithm is used while the internal machine information is recursively updated. Unlike the existing aggregation methods, the developed EMT model can reflect the characteristics of each WT under different wind speeds and WT parameters without modifying the codes. The access to each WT controller is preserved so that the time-varying dynamics of all the WTs could be simulated. Comparisons of the proposed model with the detailed model in PSCAD/EMTDC have shown very high precision and high efficiency. The proposed modeling procedures can be used as reference for other types of WTs once the structures and parameters are given. 展开更多
关键词 Offshore wind farm(OWF) electro-magnetic transient(EMT) integrated equivalent modelling permanent magnet synchronous generator(PMSG)based wind turbine(WT)
原文传递
A Review of Direct Driven PMSG for Wind Energy Systems 被引量:1
10
作者 Faeka Khater Alaa Omar 《Journal of Energy and Power Engineering》 2013年第8期1592-1603,共12页
This paper presents a comprehensive overview study of the DDPMSG (direct driven permanent magnet synchronous generator) for wind energy generation system. Wind turbine controls are provided. The PMSG (permanent mag... This paper presents a comprehensive overview study of the DDPMSG (direct driven permanent magnet synchronous generator) for wind energy generation system. Wind turbine controls are provided. The PMSG (permanent magnet synchronous generator) is introduced as construction and model. Configurations of different power converters are presented for use with DDPMSG in wind systems at variable speed operation and maximum power capture. Control techniques for the system are discussed for both machine-side and grid-side in details. Grid integration is provided with focus on how to insure power quality of the system and the performance at disturbances. 展开更多
关键词 direct-driven permanent magnet synchronous generator wind turbine power converter control.
下载PDF
Design and Implementation of Bi-Directional DC-DC Converter for Wind Energy System 被引量:1
11
作者 K. Suresh Dr. R. Arulmozhiyal 《Circuits and Systems》 2016年第11期3705-3722,共18页
This paper proposes a design and implementation of the bi-directional DC-DC converter for Wind Energy Conversion System. The proposed project consists of boost DC/DC converter, bi-directional DC/DC converter (BDC), pe... This paper proposes a design and implementation of the bi-directional DC-DC converter for Wind Energy Conversion System. The proposed project consists of boost DC/DC converter, bi-directional DC/DC converter (BDC), permanent magnet DC generator and batteries. A DC-DC boost converter is interface with proposed wind system to step up the initial generator voltage and maintain constant output voltage. The fluctuation nature of wind makes them unsuitable for standalone operation. To overcome the drawbacks an energy storage device is used in the proposed system to compensate the fluctuations and to maintain a smooth and continuous power flow in all operating modes to load. Bi-directional DC-DC converter (BDC) is capable of transforming energy between two DC buses. It can operate as a boost converter which supplies energy to the load when the wind generator output power is greater than the required load power. It also operates in buck mode which charges from DC bus when output power is less than the required load power. The proposed converter reduces the component losses and increases the performance of the overall system. The complete system is implemented in MATLAB/SIMULINK and verified with hardware. 展开更多
关键词 Bidirectional DC/DC Converter Boost DC/DC Converter wind Turbine Generation System (WTGS) permanent magnet DC generator (PMDC)
下载PDF
The Multi-Objective Optimization of AFPM Generators with Double-Sided Internal Stator Structures for Vertical Axis Wind Turbines
12
作者 Dandan Song Lianjun Zhou +2 位作者 Ziqi Peng Senhua Luo Jun Zhu 《Energy Engineering》 EI 2021年第5期1439-1452,共14页
The axial flux permanent magnet(AFPM)generator with double-sided internal stator structure is highly suitable for vertical axis wind turbines due to its high power density.The performance of the AFPM generator with do... The axial flux permanent magnet(AFPM)generator with double-sided internal stator structure is highly suitable for vertical axis wind turbines due to its high power density.The performance of the AFPM generator with double-sided internal stator structure can be improved by the reasonable design of electromagnetic parameters.To further improve the overall performance of the AFPM generator with double-sided internal stator structure,multivariable(coil widthω_(c),permanent magnet thickness h,pole arc coefficient α_(p) and working air gap l_(g))and multi-objective(generator efficiencyη,total harmonic distortion of the voltage THD and induced electromotive force amplitude EMF)functional relationships are innovatively established.Orthogonal analysis,mean analysis and variance analysis are performed on the influence parameters by combining the Taguchi method and response surface methodology to study the influence degrees of each influence parameter on the optimization objectives to determine the most appropriate electromagnetic parameters.The optimization results are verified by 3D finite element analysis.The optimized APFM generator with double-sided internal stator structure exhibits superior economy,stronger magnetic density,higher efficiency and improved power quality. 展开更多
关键词 wind turbine double-sided internal stator structure multi-objective optimization axial flux permanent magnet generator
下载PDF
Torque analysis for double-stator permanent-magnet motor
13
作者 柴凤 程树康 崔淑梅 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2002年第4期411-414,共4页
In addition to the characteristics of a conventional motor, a novel direct-drive double-stator permanent-magnet brushless motor proposed can operate in the state of either a generator or a motor as appropriate. Throug... In addition to the characteristics of a conventional motor, a novel direct-drive double-stator permanent-magnet brushless motor proposed can operate in the state of either a generator or a motor as appropriate. Through numerical calculation and analysis, the output torque of double-stator permanent-magnet brushless motor of the same volume as the traditional machine is discussed, and the reduction of torque ripple by using the structure features of this motor is investigated. The results indicate that lower torque ripple under the condition of ideal effective torque can be obtained by the rational design of motor. The prototype motors tested show that this kind of motor structure has a higher power density. 展开更多
关键词 direct-DRIVE MOTOR DOUBLE-STATOR permanent-magnet MOTOR
下载PDF
Analysis on Effect of Parameters of Different Wind Generator on Power Grid Transient Stability
14
作者 Zhi-wei Wen Li Ding Shi-en He 《Energy and Power Engineering》 2013年第4期363-367,共5页
To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different... To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different wind farm integration on grid typically in China has been presented. The influence of the variations of transient reactance, negative sequence reactance and rotary inertia on critical clearing time of power system transient stability is analyzed by time-domain simulation. Mixture operation of DFIG and PMSG to optimize the stability of system has been analyzed firstly. The digital simulation results show that doubly-fed induction wind turbines is a better choice to meet the requirement of system instability due to large wind farm integration in comparison with direct-drive PM synchronous wind turbines. With a rather large rotary inertia, the proper ratio of direct-drive PM synchronous wind turbines used in wind farm could be comprehensive planning by optimized the stability of system. Analysis of this paper should be provided as academic reference for improving design of wind farm system. 展开更多
关键词 wind FARM DOUBLY-FED Induction generator direct-DRIVE PM SYNCHRONOUS generator Parameter
下载PDF
Dynamic characteristics of large permanent magnet direct‐drive generators considering electromagnetic–structural coupling effects
15
作者 Qinkai Han Xueping Xu +3 位作者 Zhihong Zhang Yifeng Yan Chao Peng Fulei Chu 《International Journal of Mechanical System Dynamics》 2023年第1期25-38,共14页
Dynamic characteristics of large permanent magnet direct‐drive generators(PMDGs)considering electromagnetic–structural coupling effects are analyzed in this study.Using the conformal mapping method,the scalar magnet... Dynamic characteristics of large permanent magnet direct‐drive generators(PMDGs)considering electromagnetic–structural coupling effects are analyzed in this study.Using the conformal mapping method,the scalar magnetic potential of the air gap magnetic field considering the slot effect is calculated.On the basis of the discrete current element and magnetic equivalent circuit model,the local magnetic saturation effect of the stator and rotor is quantitatively simulated and the air gap magnetic field intensity distribution is obtained via numerical simulation.A series of uniformly distributed equivalent electromagnetic springs are introduced to develop an electromagnetic–structural coupling finite element PMDG model.The proposed air gap field analysis method is verified by the finite element analysis results.On the basis of the test platform for the Goldwind 1.5MW PMDG,both modal and dynamic response tests for the stator/rotor coupling system are conducted,and the results are compared with the natural frequencies,mode shapes,and vibration responses obtained using the numerical model.The effects of the air gap length and rotor speed on the natural frequencies of the coupling system are analyzed.The proposed model has the potential to accurately evaluate the PMDG vibration energy,avoiding resonance points,and maintaining stable operations of the unit. 展开更多
关键词 permanent magnet direct‐drive generators dynamic characteristics electromagnetic–structural coupling effects conformal mapping magnetic equivalent circuit model electromagnetic springs
原文传递
A Novel Modified Fuzzy-predictive Control of Permanent Magnet Synchronous Generator Based Wind Energy Conversion System
16
作者 Ehsan Akbari Milad Samady Shadlu 《Chinese Journal of Electrical Engineering》 EI CSCD 2023年第4期107-121,共15页
A wind energy conversion system(WECS)based on a permanent magnet synchronous generator(PMSG)is an effective solution for renewable energy generation in modern power systems.The main advantages of PMSG include high per... A wind energy conversion system(WECS)based on a permanent magnet synchronous generator(PMSG)is an effective solution for renewable energy generation in modern power systems.The main advantages of PMSG include high performance at high and low speeds,minimal control effort owing to lower rotor inertia,self-excitation,high reliability,and simplicity of structure compared with induction generators.However,the intermittent nature of wind energy implies that maximum efficiency is not obtained from this system.Accordingly,maximum power point tracking(MPPT)in wind turbine systems has been proposed to address this problem.Traditional MPPT strategies suffer from severe output power fluctuations,low efficiency,and significant ripples in turbine rotation speed.This paper presents a novel MPPT control strategy based on fuzzy logic control(FLC)and model predictive control(MPC)to extract the maximum power from a PMSG-WECS and control the machine-side and grid-side converters.The simulation results obtained from Matlab/Simulink confirm the superiority of the control model in eliminating the output power fluctuations of the wind generators and accurately tracking the maximum power point.A comparative study between conventional MPPT and control methods is also conducted. 展开更多
关键词 Maximum power point tracking(MPPT) wind energy conversion system(WECS) permanent magnet synchronous generator(PMSG) fuzzy logic control(FLC) model predictive control(MPC)
原文传递
含静止无功发生器的直驱风电并网系统稳定性分析及振荡抑制策略 被引量:2
17
作者 张芳 王赫 李传栋 《电力自动化设备》 EI CSCD 北大核心 2024年第6期1-8,17,共9页
风电并网系统稳定性分析及振荡抑制策略大多集中于风电场本身,针对含静止无功发生器(SVG)的直驱风电并网系统研究较少。基于特征值灵敏度筛选出对含SVG的直驱风电并网系统稳定性较显著的控制通道,然后基于独立通道分析设计理论将并网系... 风电并网系统稳定性分析及振荡抑制策略大多集中于风电场本身,针对含静止无功发生器(SVG)的直驱风电并网系统研究较少。基于特征值灵敏度筛选出对含SVG的直驱风电并网系统稳定性较显著的控制通道,然后基于独立通道分析设计理论将并网系统由多输入多输出耦合系统等效拆分为多个单输入单输出控制通道,在定性分析并网系统稳定性的同时定量评估不同控制通道间的交互作用程度。为抑制控制通道间的交互作用,提出了基于H∞鲁棒控制的次同步振荡抑制策略。通过电磁暂态仿真,验证了基于独立通道分析设计理论分析并网系统稳定性的正确性以及基于H∞鲁棒控制的次同步振荡抑制策略的有效性。 展开更多
关键词 直驱风电机组 静止无功发生器 独立通道 H∞鲁棒控制 振荡抑制
下载PDF
虚拟惯量控制对直驱风电机组载荷影响的分析及评估
18
作者 杨超 李东翰 +3 位作者 雷显帅 李辉 李海啸 刘静 《电力系统自动化》 EI CSCD 北大核心 2024年第7期258-266,共9页
针对虚拟惯量控制诱发风电机组机械载荷的问题,开展虚拟惯量控制对采用直驱永磁同步发电机(D-PMSG)的风电机组载荷影响的理论分析和仿真评估研究。从叶片、塔筒等机械结构低阶模态出发,建立虚拟惯量控制下D-PMSG线性化多体动力学模型,... 针对虚拟惯量控制诱发风电机组机械载荷的问题,开展虚拟惯量控制对采用直驱永磁同步发电机(D-PMSG)的风电机组载荷影响的理论分析和仿真评估研究。从叶片、塔筒等机械结构低阶模态出发,建立虚拟惯量控制下D-PMSG线性化多体动力学模型,并通过线性化多体动力学模型分析虚拟惯量控制对机组载荷的影响机理。采用软件联合建模方法,构建涵盖永磁同步电机及其控制、电网、机械和气动特性等的D-PMSG非线性机电耦合模型。依据冲击载荷最大值、最大变化幅度百分比及等值疲劳载荷等指标,通过所建立的非线性机电耦合模型仿真分析并量化评估虚拟惯量控制对机组冲击载荷和动态疲劳载荷的影响。结果表明,D-PMSG附加虚拟惯量控制后,电网侧频率突变会使得传动轴和塔底侧向出现显著冲击载荷,且其随虚拟惯量时间常数增大而增大,在湍流风运行工况下机组传动轴和塔底侧向等值疲劳载荷较无附加虚拟惯量控制均有所减小。 展开更多
关键词 风力发电 直驱永磁同步发电机 虚拟惯量控制 机械载荷
下载PDF
永磁同步发电机匝间短路故障对绕组绝缘温升特性的影响
19
作者 何玉灵 李勇 +3 位作者 张文 白怡凡 徐明星 王晓龙 《电机与控制学报》 EI CSCD 北大核心 2024年第4期18-30,共13页
本文分析了永磁同步发电机匝间短路故障前后的绕组绝缘温升特性。首先推导了正常情况和匝间短路故障下的气隙磁通密度,相电流、铁心损耗和绕组铜耗解析表达式;然后建立了发电机三维有限元仿真模型,将电磁场中计算得到的各类损耗作为热... 本文分析了永磁同步发电机匝间短路故障前后的绕组绝缘温升特性。首先推导了正常情况和匝间短路故障下的气隙磁通密度,相电流、铁心损耗和绕组铜耗解析表达式;然后建立了发电机三维有限元仿真模型,将电磁场中计算得到的各类损耗作为热源导入温度场计算绕组绝缘温度分布;最后实测了LR-5型故障模拟永磁同步发电机组在不同短路程度下的绕组绝缘温度,理论分析、仿真计算与实验结果相互吻合。结果表明:匝间短路故障后在故障绕组电流的作用下,绕组绝缘温度明显上升,并且随着短路程度的增加而加剧,由绕组绝缘热载荷分布不均而引起的变形、应变和应力也将增加;绕组鼻端处绝缘易因高温而受损,可通过改进冷却散热结构,或在鼻端绝缘局部涂覆耐热涂层提高鼻端绝缘的可靠性。 展开更多
关键词 永磁同步发电机 绕组绝缘 匝间短路 温升特性 危险位置
下载PDF
永磁直驱型风机海上风电送出系统不对称接地及甩负荷电磁暂态研究
20
作者 王爽 陈小月 +5 位作者 郑智慧 李炬添 张振 林睿 王羽 鲁海亮 《中国电机工程学报》 EI CSCD 北大核心 2024年第2期827-837,I0033,共12页
为明确海上风电交流送出系统过电压的特征与水平,需考虑风电机组的故障穿越特性。该文结合永磁直驱风机变流器的控制原理,提出海上风电送出系统不对称接地过电压的解析计算方法。基于PSCAD对风电机组进行精确电磁暂态建模与故障电压穿... 为明确海上风电交流送出系统过电压的特征与水平,需考虑风电机组的故障穿越特性。该文结合永磁直驱风机变流器的控制原理,提出海上风电送出系统不对称接地过电压的解析计算方法。基于PSCAD对风电机组进行精确电磁暂态建模与故障电压穿越测试,以国内某500 kV大规模海上风电工程为背景,仿真计算送出系统不对称接地及甩负荷过电压。结果表明:系统不对称接地过电压大小与风机正负序控制策略有关;海缆电网侧甩负荷将产生持续百ms的1.3 pu以上的暂态过电压,风机过电压保护动作延时越长,暂态过电压越严重。实际海上风电工程计算需紧密联系风机控制保护策略及其参数,并综合关键设备耐压水平进行评估,通过风机控制策略优化可以降低系统过电压水平。 展开更多
关键词 海上风电 永磁直驱风机 控制保护策略 不对称接地 甩负荷 暂态过电压
下载PDF