Ac-Stark shift of atom levels is caused by an ac-electromagnetic field. As an electromagnetic wave, laser light does induce ac-Stark shift. It is proved experimentally that if the light is linearly polarized, the dyna...Ac-Stark shift of atom levels is caused by an ac-electromagnetic field. As an electromagnetic wave, laser light does induce ac-Stark shift. It is proved experimentally that if the light is linearly polarized, the dynamic polarizability changes with polarization direction. The polarization direction of the linearly-polarized laser is tuned by 720°, and the ac-Stark shifts of the 4S1/2,m=±1/2→3D5/2,m=±1/2 clock transitions in ^40Ca^+ are measured in steps of 10°. The frequency shifts change with laser polarization in a periodical manner and have values opposite to each other.展开更多
In order to diagnose gear shifting process in automated manual transmission(AMT),a semi-quantitative signed directed graph(SDG)model is applied.Mathematical models are built by analysis of the power train dynamic ...In order to diagnose gear shifting process in automated manual transmission(AMT),a semi-quantitative signed directed graph(SDG)model is applied.Mathematical models are built by analysis of the power train dynamic and the gear shifting control process.The SDG model is built based on related priori knowledge.By calculating the fuzzy membership degree of each compatible passway and its possible fault source,we get the possibilities of failure for each possible fault source.We begin with the nodes with the maximum possibility of failure in order to find the failed part.The diagnosis example shows that it is feasible to use the semi-quantitative SDG model for fault diagnosis of the gear shifting process in AMT.展开更多
为解决双向DC-DC变换器(dual active bridge,DAB)采用单移相(single-phase-shift,SPS)控制产生的回流功率较高及动态性能较差的问题,提出一种采用双重移相(dual-phase-shift,DPS)控制下的最小回流功率算法与直接功率控制相结合的方法。...为解决双向DC-DC变换器(dual active bridge,DAB)采用单移相(single-phase-shift,SPS)控制产生的回流功率较高及动态性能较差的问题,提出一种采用双重移相(dual-phase-shift,DPS)控制下的最小回流功率算法与直接功率控制相结合的方法。首先对DPS控制下的基本原理及回流功率特性进行分析,并建立回流功率与移相比之间的数学关系,从而推导出各分段条件下回流功率在各阶段最小化的方案。其次在保证对变换器回流功率最小化的同时提出结合直接功率法来显著提高变换器的动态性能。最后通过MATLAB/Simulink中建立的仿真验证了上述控制策略的有效性。展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.91336211,11634013,11622434,11474318,and 11504094)the Chinese Academy of Sciences(Grant No.XDB21030000)
文摘Ac-Stark shift of atom levels is caused by an ac-electromagnetic field. As an electromagnetic wave, laser light does induce ac-Stark shift. It is proved experimentally that if the light is linearly polarized, the dynamic polarizability changes with polarization direction. The polarization direction of the linearly-polarized laser is tuned by 720°, and the ac-Stark shifts of the 4S1/2,m=±1/2→3D5/2,m=±1/2 clock transitions in ^40Ca^+ are measured in steps of 10°. The frequency shifts change with laser polarization in a periodical manner and have values opposite to each other.
基金Supported by the Basic Research Foundation of Beijing Institute of Technology(20130342035)
文摘In order to diagnose gear shifting process in automated manual transmission(AMT),a semi-quantitative signed directed graph(SDG)model is applied.Mathematical models are built by analysis of the power train dynamic and the gear shifting control process.The SDG model is built based on related priori knowledge.By calculating the fuzzy membership degree of each compatible passway and its possible fault source,we get the possibilities of failure for each possible fault source.We begin with the nodes with the maximum possibility of failure in order to find the failed part.The diagnosis example shows that it is feasible to use the semi-quantitative SDG model for fault diagnosis of the gear shifting process in AMT.
文摘为解决双向DC-DC变换器(dual active bridge,DAB)采用单移相(single-phase-shift,SPS)控制产生的回流功率较高及动态性能较差的问题,提出一种采用双重移相(dual-phase-shift,DPS)控制下的最小回流功率算法与直接功率控制相结合的方法。首先对DPS控制下的基本原理及回流功率特性进行分析,并建立回流功率与移相比之间的数学关系,从而推导出各分段条件下回流功率在各阶段最小化的方案。其次在保证对变换器回流功率最小化的同时提出结合直接功率法来显著提高变换器的动态性能。最后通过MATLAB/Simulink中建立的仿真验证了上述控制策略的有效性。