Submersible electrical motor direct-drive progressing cavity pump (PCP) rodless lifting was studied to solve the traditional rod-drive pump problems, such as rod-tubing wearing, low efficiency and short running time. ...Submersible electrical motor direct-drive progressing cavity pump (PCP) rodless lifting was studied to solve the traditional rod-drive pump problems, such as rod-tubing wearing, low efficiency and short running time. The theoretical researches and laboratory experiments of key tools such as submersible motor and the construction technology of lifting system were introduced. The field application and economic benefit were analyzed and compared with the traditional rod pumping unit. A new low speed and large torque permanent magnet synchronous motor was developed. This motor was used to drive PCP without gear reducer, which improved the reliability and feasibility. It can run at the speed from 50 to 500 r/min with stepless speed regulation, and it can perform high efficiency and large torque. Besides, other key supporting tools, such as motor protector and flex shaft, were developed. The submersible electrical motor direct- drive PCP technology can be used in a 139.7 mm (5.5 in) casing well, with daily output ranging from 5 to 50 m3. Until now, the technology has been deployed more than 100 wells. The field application results show that it eliminates the rod-tubing wearing and saves electric energy by more than 30% compared with the traditional rod pumping unit. And it also makes the oil produced in a safe and environmental friendly way.展开更多
To control the position of differential cylinder closed loop without usingany throttle elements, a flew idea that two speed variable pumps are used to compensate thenon-symmetric flow of differential cylinder is carri...To control the position of differential cylinder closed loop without usingany throttle elements, a flew idea that two speed variable pumps are used to compensate thenon-symmetric flow of differential cylinder is carried out. According to the leaking property of thesystem, a speed offset principle is also proposed to eliminate the cavitation and tension caused bythe leakage and condensation of oil, which makes the system be in the same state as a valvecontrolled circuit. This principle is explained theoretically and experimentally. Further therelationship that the pressures in cylinder chambers change with load and leakage, and therelationship between biasing speed and pre-load pressures in cylinder chambers are established. Theresearch has proved that the new system has similar technique features as those of controlled withservo valves, but due to the elimination of all the throttle lose the efficiency of system can beimproved greatly.展开更多
The time domain guideposts requirements of a pump-motor system is transfered into a series of constraints which express the robust performance upper bound and regional poles limits of the closed loop system. Then the ...The time domain guideposts requirements of a pump-motor system is transfered into a series of constraints which express the robust performance upper bound and regional poles limits of the closed loop system. Then the servo system control problem is transferred into the problem of robust performance optimizing under regional poles constrains described by linear matrix inequality (LMI). These LMIs are easy to solve through the Matlab LMI-toolbox. Simulations indicate that the controller has excellent dynamic, static and disturbance rejection performance, and the control system is robust and has perfect H2 performance to the bounded external torque disturbance.展开更多
基金Supported by the PetroChina Science and Technology Project(2016B-4104)
文摘Submersible electrical motor direct-drive progressing cavity pump (PCP) rodless lifting was studied to solve the traditional rod-drive pump problems, such as rod-tubing wearing, low efficiency and short running time. The theoretical researches and laboratory experiments of key tools such as submersible motor and the construction technology of lifting system were introduced. The field application and economic benefit were analyzed and compared with the traditional rod pumping unit. A new low speed and large torque permanent magnet synchronous motor was developed. This motor was used to drive PCP without gear reducer, which improved the reliability and feasibility. It can run at the speed from 50 to 500 r/min with stepless speed regulation, and it can perform high efficiency and large torque. Besides, other key supporting tools, such as motor protector and flex shaft, were developed. The submersible electrical motor direct- drive PCP technology can be used in a 139.7 mm (5.5 in) casing well, with daily output ranging from 5 to 50 m3. Until now, the technology has been deployed more than 100 wells. The field application results show that it eliminates the rod-tubing wearing and saves electric energy by more than 30% compared with the traditional rod pumping unit. And it also makes the oil produced in a safe and environmental friendly way.
基金This project is supported by National Natural Science Foundation of China(No.50275102) National Foundation for Abroad Return People, China (No.2001345).
文摘To control the position of differential cylinder closed loop without usingany throttle elements, a flew idea that two speed variable pumps are used to compensate thenon-symmetric flow of differential cylinder is carried out. According to the leaking property of thesystem, a speed offset principle is also proposed to eliminate the cavitation and tension caused bythe leakage and condensation of oil, which makes the system be in the same state as a valvecontrolled circuit. This principle is explained theoretically and experimentally. Further therelationship that the pressures in cylinder chambers change with load and leakage, and therelationship between biasing speed and pre-load pressures in cylinder chambers are established. Theresearch has proved that the new system has similar technique features as those of controlled withservo valves, but due to the elimination of all the throttle lose the efficiency of system can beimproved greatly.
文摘The time domain guideposts requirements of a pump-motor system is transfered into a series of constraints which express the robust performance upper bound and regional poles limits of the closed loop system. Then the servo system control problem is transferred into the problem of robust performance optimizing under regional poles constrains described by linear matrix inequality (LMI). These LMIs are easy to solve through the Matlab LMI-toolbox. Simulations indicate that the controller has excellent dynamic, static and disturbance rejection performance, and the control system is robust and has perfect H2 performance to the bounded external torque disturbance.