期刊文献+
共找到992篇文章
< 1 2 50 >
每页显示 20 50 100
Design of Permanent Magnet Synchronous Generators for Wave Power Generation 被引量:4
1
作者 Fang Hongwei Wang Dan 《Transactions of Tianjin University》 EI CAS 2016年第5期396-402,共7页
In this paper, a design method for ocean wave permanent magnet synchronous generator(PMSG)is proposed with new performance criteria to obtain better output performance at the cost of less permanent magnet material. Be... In this paper, a design method for ocean wave permanent magnet synchronous generator(PMSG)is proposed with new performance criteria to obtain better output performance at the cost of less permanent magnet material. Besides, a simple equivalent analytical geometry method is put forward to calculate the sizes of permanent magnets. Based on geometric and electromagnetic models, four types of rotor structures are compared, i.e., embedded, tangential, tile surface mount and convex surface mount structures. The designs and comparisons of machine are performed with the same permanent magnet volume. Moreover, the influences of mechanical pole-arc coefficient of tile surface mount PMSG on electrical efficiency, output power, material corrosion, core loss, and torque ripple are investigated. Finite-element analysis method is applied to verify the results using Ansoft/Maxwell. 展开更多
关键词 analytical geometry method mechanical pole-arc coefficient OCEAN wave power generation permanent magnet synchronous generator
下载PDF
Maximum Power Point Tracking in Variable Speed Wind Turbine Based on Permanent Magnet Synchronous Generator Using Maximum Torque Sliding Mode Control Strategy 被引量:3
2
作者 Esmaeil Ghaderi Hossein Tohidi Behnam Khosrozadeh 《Journal of Electronic Science and Technology》 CAS CSCD 2017年第4期391-399,共9页
The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, th... The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, the rotor speed is set at an optimal point for different wind speeds. As a result of which, the tip speed ratio reaches an optimal point, mechanical power coefficient is maximized, and wind turbine produces its maximum power and mechanical torque. Then, the maximum mechanical torque is tracked using electromechanical torque. In this technique, tracking error integral of maximum mechanical torque, the error, and the derivative of error are used as state variables. During changes in wind speed, sliding mode control is designed to absorb the maximum energy from the wind and minimize the response time of maximum power point tracking(MPPT). In this method, the actual control input signal is formed from a second order integral operation of the original sliding mode control input signal. The result of the second order integral in this model includes control signal integrity, full chattering attenuation, and prevention from large fluctuations in the power generator output. The simulation results, calculated by using MATLAB/m-file software, have shown the effectiveness of the proposed control strategy for wind energy systems based on the permanent magnet synchronous generator(PMSG). 展开更多
关键词 Maximum power point tracking permanent magnet synchronous generator(PMSG) sliding mode control wind turbine
下载PDF
The Study of Optimal Structure and Value of Dump Resistance in Direct-Drive Permanent Magnet Synchronous Generators 被引量:3
3
作者 Jun Jia Jie Zhao +3 位作者 Dichen Liu Chen Cheng Jun Wang Linge Qi 《Journal of Power and Energy Engineering》 2014年第4期334-339,共6页
This paper studied the direct-drive permanent magnet synchronous machine (permanent magnet synchronous generator, PMSG) Chopper optimal topology and resistance value. Compared the different Chopper circuit low voltage... This paper studied the direct-drive permanent magnet synchronous machine (permanent magnet synchronous generator, PMSG) Chopper optimal topology and resistance value. Compared the different Chopper circuit low voltage ride-through capability in the same grid fault conditions in simulation. This paper computes the dump resistance ceiling according to the power electronic devices and over-current capability. Obtaining the dump resistance low limit according to the temperature resistance allows, and calculating the optimal value by drop voltage in the DC-Bus during the fault. The feasibility of the proposed algorithm is verified by simulation results. 展开更多
关键词 permanent magnetic synchronous generator (PMSG) Optimal RESISTANCE CHOPPER
下载PDF
Analysis and Design of Surface Permanent Magnet Synchronous Motor and Generator 被引量:7
4
作者 Chengyuan He Thomas Wu 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第1期94-100,共7页
This paper presents an analytical method to design the high-efficiency surface permanent magnet synchronous motor(SPMSM)or generator(SPMSG).The air-gap and permanent magnet size can be approximately determined based o... This paper presents an analytical method to design the high-efficiency surface permanent magnet synchronous motor(SPMSM)or generator(SPMSG).The air-gap and permanent magnet size can be approximately determined based on our mathematics model,which is the most important part of SPMSM design.From our method,we can know that motor’s power out torque is related to the torque angle that we selected in our design and it affects the air-gap and permanent magnet size.If we choose a low torque angle,the motor or generator’s overload power handing capability will increase.The embrace value has a vital place in designing a motor or generator due to its effects on air gap flux density,cogging torque,efficiency and so on.In order to avoid the knee effect,the working point of the permanent magnet we selected in the design should be bigger than 0.5.The developed 36 slots,4 poles,surface mound permanent generator is proposed.The corresponding finite element analysis(FEA)model is built based on our design method.Structure optimization includes stator and rotor structure size,permanent magnet size,magnetic bridge and air gap length which are analyzed and simulated by ANSYS Maxwell 2D FEA.Thermal analysis is conducted,and the housing of the alternator is designed.The alternator prototype is fabricated and tested based on our design. 展开更多
关键词 initeelement analysis FABRICATION high-efficiency mathematic model surface permanent magnet synchronous motor or generator.
下载PDF
Performance analysis of 20 Pole 1.5 KW Three Phase Permanent Magnet Synchronous Generator for low Speed Vertical Axis Wind Turbine 被引量:2
5
作者 Shahrukh Adnan Khan Rajprasad K. Rajkumar +1 位作者 Rajparthiban K. Rajkumar Aravind CV 《Energy and Power Engineering》 2013年第4期423-428,共6页
This paper gives performance analysis of a three phase Permanent Magnet Synchronous Generator (PMSG) connected to a Vertical Axis Wind Turbine (VAWT). Low speed wind condition (less than 5 m/s) is taken in considerati... This paper gives performance analysis of a three phase Permanent Magnet Synchronous Generator (PMSG) connected to a Vertical Axis Wind Turbine (VAWT). Low speed wind condition (less than 5 m/s) is taken in consideration and the entire simulation is carried in Matlab/Simulink environment. The rated power for the generator is fixed at 1.5 KW and number of pole at 20. It is observed under low wind speed of6 m/s, a turbine having approximately1 mof radius and2.6 mof height develops 150 Nm mechanical torque that can generate power up to 1.5 KW. The generator is designed using modeling tool and is fabricated. The fabricated generator is tested in the laboratory with the simulation result for the error analysis. The range of error is about 5%-27% for the same output power value. The limitations and possible causes for error are presented and discussed. 展开更多
关键词 Vertical Axis WIND TURBINE Three Phase Multi-pole permanent magnet synchronous generator Low WIND Speed Modeling Performance Analysis
下载PDF
Predictive control of a chaotic permanent magnet synchronous generator in a wind turbine system 被引量:1
6
作者 Manal Messadi Adel Mellit +1 位作者 Karim Kemih Malek Ghanes 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第1期177-183,共7页
This paper investigates how to address the chaos problem in a permanent magnet synchronous generator(PMSG) in a wind turbine system. Predictive control approach is proposed to suppress chaotic behavior and make oper... This paper investigates how to address the chaos problem in a permanent magnet synchronous generator(PMSG) in a wind turbine system. Predictive control approach is proposed to suppress chaotic behavior and make operating stable;the advantage of this method is that it can only be applied to one state of the wind turbine system. The use of the genetic algorithms to estimate the optimal parameter values of the wind turbine leads to maximization of the power generation.Moreover, some simulation results are included to visualize the effectiveness and robustness of the proposed method. 展开更多
关键词 permanent magnet synchronous generator chaotic system genetic algorithm predictive control
下载PDF
Influence of Design Parameters on Cogging Torque in Directly Driven Permanent Magnet Synchronous Wind Generators
7
作者 Q.L. Deng S.D. Huang F. Xiao 《Journal of Energy and Power Engineering》 2010年第7期42-47,共6页
In order to reduce the cogging torque, this paper investigates the influence of some parameters on the cogging torque developed by directly driven permanent magnet synchronous wind generators. Based on the remanent ma... In order to reduce the cogging torque, this paper investigates the influence of some parameters on the cogging torque developed by directly driven permanent magnet synchronous wind generators. Based on the remanent magnetic flux densities, the cogging torque is computed by using finite element method. It is shown that many parameters have influence on cogging torque and the slot and pole number combination has a significant effect on cogging torque. A simple factor has been introduced to indicate the effect of the slot and pole number combination. Some practical experience to reduce the cogging torque was applied to 2 MW three phase permanent magnet synchronous generator at rated speed of 37.5 rpm for wind energy conversion. The simulation and experiment results verify the effect of the proposed method. 展开更多
关键词 Cogging torque permanent magnet synchronous generator electric machine design.
下载PDF
Prediction of the Inductance in a Synchronous Linear Permanent Magnet Generator
8
作者 Boel Ekergard Rafael Waters Mats Leijon 《Journal of Electromagnetic Analysis and Applications》 2011年第5期155-159,共5页
This paper presents calculations of the varying inductances profile for a synchronous linear surface mounted permanent magnet generator in an ABC reference system. Calculations are performed by utilizing the reluctanc... This paper presents calculations of the varying inductances profile for a synchronous linear surface mounted permanent magnet generator in an ABC reference system. Calculations are performed by utilizing the reluctance term, known from analytic calculations and finite element method simulations. With the inductance term identified, the voltage difference between the generator’s no load and load voltage can be calculated and an external circuit can be designed for optimal use of the generator. Two different operation intervals of the linear generator are considered and the results are discussed. The result indicates that time costly finite element simulations can be replaced with simple analytical calculations for a surface mounted permanent magnet linear generator. 展开更多
关键词 Wave Power synchronous Linear permanent magnet generator Varying Inductance ABC of Frame Reference
下载PDF
Coordinated Robust PID-based Damping Control of Permanent Magnet Synchronous Generators for Low-frequency Oscillations Considering Power System Operational Uncertainties
9
作者 Rehan Sadiq Zhen Wang +2 位作者 Chi Yung Chung Deqiang Gan Cunzhi Tong 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第4期1042-1051,共10页
In recent years, with the growth of wind energy resources,the capability of wind farms to damp low-frequency oscillations(LFOs) has provided a notable advantage for the stabilityenhancement of the modern power grid. M... In recent years, with the growth of wind energy resources,the capability of wind farms to damp low-frequency oscillations(LFOs) has provided a notable advantage for the stabilityenhancement of the modern power grid. Meanwhile, owingto variations in the power system operating point (OP), thedamping characteristics of LFOs may be affected adversely. Inthis respect, this paper presents a coordinated robust proportional-integral-derivative (PID) based damping control approachfor permanent magnet synchronous generators (PMSGs)to effectively stabilize LFOs, while considering power system operationaluncertainties in the form of a polytopic model constructedby linearizing the power system under a given set ofOPs. The proposed approach works by modulating the DC-linkvoltage control loop of the grid-side converter (GSC) via a supplementaryPID controller, which is synthesized by transformingthe design problem into H-infinity static output feedback(SOF) control methodology. The solution of H-infinity SOF controlproblem involves satisfying linear matrix inequality (LMI)constraints based on the parameter-dependent Lyapunov functionto ensure asymptotic stability such that the minimal H-infinityperformance objective is simultaneously accomplished forthe entire polytope. The coordinated damping controllers forthe multiple wind farms are then designed sequentially by usingthe proposed approach. Eigenvalue analysis confirms the improveddamping characteristics of the closed-loop system forseveral representative OPs. Afterward, the simulation results, includingthe performance comparison with existing approaches,validate the higher robustness of the proposed approach for awide range of operating scenarios. 展开更多
关键词 permanent magnet synchronous generator(PMSG) low-frequency oscillation(LFO) proportional-integralderivative(PID) robust control H-infinity static output feed-back control linear matrix inequality(LMI)
原文传递
Current Loop Disturbance Suppression for Dual Three Phase Permanent Magnet Synchronous Generators Based on Modified Linear Active Disturbance Rejection Control
10
作者 Dezhi Xu Hu Yao +1 位作者 Yang He Wenxiang Zhao 《Chinese Journal of Electrical Engineering》 EI CSCD 2024年第1期101-113,共13页
A modified four-dimensional linear active disturbance rejection control(LADRC)strategy is proposed for a dual three-phase permanent magnet synchronous generator(DTP-PMSG)system to reduce cross-coupling between the d a... A modified four-dimensional linear active disturbance rejection control(LADRC)strategy is proposed for a dual three-phase permanent magnet synchronous generator(DTP-PMSG)system to reduce cross-coupling between the d and q axis currents in the d-q subspace and harmonic currents in the x-y subspace.In the d-q subspace,the proposed strategy uses a model-based LADRC to enhance the decoupling effect between the d and q axes and the disturbance rejection ability against parameter variation.In the x-y subspace,the 5th and 7th harmonic current suppression abilities are improved by using quasi-resonant units parallel to the extended state observer of the traditional LADRC.The proposed modified LADRC strategy improved both the steady-state performance and dynamic response of the DTP-PMSG system.The experimental results demonstrate that the proposed strategy is both feasible and effective. 展开更多
关键词 Dual three-phase permanent magnet synchronous generator current loop decoupling control harmonic suppression linear active disturbance rejection control
原文传递
An Improved Stator Flux Observation Method of Permanent Magnet Synchronous Motor 被引量:1
11
作者 Guangjing Su Hongmei Li +1 位作者 Ying Dai Zheng Li 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2016年第6期90-96,共7页
The stator flux and electromagnetic torque observation is the basis of direct torque controlled permanent magnet synchronous motor( PMSM) drive system. However,the traditional stator flux observer based on voltage mod... The stator flux and electromagnetic torque observation is the basis of direct torque controlled permanent magnet synchronous motor( PMSM) drive system. However,the traditional stator flux observer based on voltage model is affected by integral initial values and integral drift,that based on current model is affected by the parameters of PMSM,so a new stator flux observation method is proposed based on an improved secondorder generalized integrator( SOGI). Compared to the stator flux observation method based on the conventional SOGI,the proposed method can not only overcome the influence of integral initial values and integral drift,but also completely eliminate the DC offset's influence. Therefore,the observation accuracy of stator flux is further improved. The simulation and experimental results both show that the proposed method has a higher stator flux and electromagnetic torque observation precision. 展开更多
关键词 permanent magnet synchronous motor direct torque control second-order generalized integrator stator flux observation electromagnetic torque observation
下载PDF
Design Optimization of Axial Flux Permanent Magnet (AFPM) Synchronous Machine Using 3D FEM Analysis
12
作者 Joya C. Kappatou Georgios D. Zalokostas Dimitrios A. Spyratos 《Journal of Electromagnetic Analysis and Applications》 2016年第11期247-260,共15页
This paper deals with the investigation of the behavior of a low speed, dual rotor-single coreless stator, axial flux permanent magnet synchronous machine for small power applications. Firstly, with the use of nonline... This paper deals with the investigation of the behavior of a low speed, dual rotor-single coreless stator, axial flux permanent magnet synchronous machine for small power applications. Firstly, with the use of nonlinear 3D FEM electromagnetic analysis, four models with different magnet topologies are designed, simulated and compared. With criteria such as output power, power factor and torque ripple, the best performing model is selected and a further investigation, regarding the effect of the disk rotor material on the behavior of the machine, is conducted. The simulation results show how the different types of commercially available steel types affect the magnetic field and the performance of the machine. 展开更多
关键词 Axial Flux permanent magnet magnet Topology synchronous generator
下载PDF
Integrated Equivalent Model of Permanent Magnet Synchronous Generator Based Wind Turbine for Large-scale Offshore Wind Farm Simulation 被引量:2
13
作者 Ming Zou Yan Wang +3 位作者 Chengyong Zhao Jianzhong Xu Xiaojiang Guo Xu Sun 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第5期1415-1426,共12页
The high-speed simulation of large-scale offshore wind farms(OWFs) preserving the internal machine information has become a huge challenge due to the large wind turbine(WT) count and microsecond-range time step. Hence... The high-speed simulation of large-scale offshore wind farms(OWFs) preserving the internal machine information has become a huge challenge due to the large wind turbine(WT) count and microsecond-range time step. Hence, it is undoable to investigate the internal node information of the OWF in the electro-magnetic transient(EMT) programs. To fill this gap,this paper presents an equivalent modeling method for largescale OWF, whose accuracy and efficiency are guaranteed by integrating the individual devices of permanent magnet synchronous generator(PMSG) based WT. The node-elimination algorithm is used while the internal machine information is recursively updated. Unlike the existing aggregation methods, the developed EMT model can reflect the characteristics of each WT under different wind speeds and WT parameters without modifying the codes. The access to each WT controller is preserved so that the time-varying dynamics of all the WTs could be simulated. Comparisons of the proposed model with the detailed model in PSCAD/EMTDC have shown very high precision and high efficiency. The proposed modeling procedures can be used as reference for other types of WTs once the structures and parameters are given. 展开更多
关键词 Offshore wind farm(OWF) electro-magnetic transient(EMT) integrated equivalent modelling permanent magnet synchronous generator(PMSG)based wind turbine(WT)
原文传递
The Minimum Rotor Rotation Angle for Calculating On-Load Electromotive Force Waveform of Synchronous Generators
14
作者 XIAYonghong WANG Shanming +1 位作者 HUANG Shaogang QIU Arui 《中国电机工程学报》 EI CSCD 北大核心 2012年第30期I0013-I0013,15,共1页
为了快速计算同步发电机负载运行时的稳态性能,希望在转子相对定子旋转的角度尽可能小的情况下就能够准确得到电枢绕组电动势波形。根据电机理论,针对分数槽绕组同步发电机负载运行时的气隙磁通密度进行分析,得到了准确计算电枢绕组电... 为了快速计算同步发电机负载运行时的稳态性能,希望在转子相对定子旋转的角度尽可能小的情况下就能够准确得到电枢绕组电动势波形。根据电机理论,针对分数槽绕组同步发电机负载运行时的气隙磁通密度进行分析,得到了准确计算电枢绕组电动势波形的转子最小旋转角。应用有限元法计算最小旋转角范围内定、转子不同位置下的电磁场,通过对电磁场计算结果进行后处理,得到了定子每个齿磁通在一个或者多个周期的变化波形,从而快速计算电枢绕组电动势波形。对两台不同电枢绕组形式的永磁同步发电机负载电动势波形进行了计算,通过对计算结果进行比较,验证了方法的正确性。在一台电机上进行了实验,计算结果和实验结果较吻合。该方法具有计算准确以及计算量小的优点。 展开更多
关键词 同步发电机 角度计算 旋转角度 电动势 波形 转子 空载 负载特性
下载PDF
Design and analysis of a novel hybrid cooling method of high-speed high-power permanent magnet assisted synchronous reluctance starter/generator in aviation applications
15
作者 Hong GUO Xu HE +4 位作者 Jinquan XU Wei TIAN Xiaofeng DING Laicai JU Dehong LI 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2023年第3期285-302,共18页
To improve the heat dissipation performance,this paper proposes a novel hybrid cooling method for high-speed high-power Permanent Magnet assisted Synchronous Reluctance Starter/Generator(PMa Syn R S/G)in aerospace app... To improve the heat dissipation performance,this paper proposes a novel hybrid cooling method for high-speed high-power Permanent Magnet assisted Synchronous Reluctance Starter/Generator(PMa Syn R S/G)in aerospace applications.The hybrid cooling structure with oil circulation in the housing,oil spray at winding ends and rotor end surface is firstly proposed for the PMa Syn R S/G.Then the accurate loss calculation of the PMa Syn R S/G is proposed,which includes air gap friction loss under oil spray cooling,copper loss,stator and rotor core loss,permanent magnet eddy current loss and bearing loss.The parameter sensitivity analysis of the hybrid cooling structure is proposed,while the equivalent thermal network model of the PMa Syn R S/G is established considering the uneven spraying at the winding ends.Finally,the effectiveness of the proposed hybrid cooling method is demonstrated on a 40 k W/24000 r/min PMa Syn R S/G experimental platform. 展开更多
关键词 Air gap friction loss Oil spray cooling permanent magnet assisted synchronous reluctance starter/generator Thermal analysis Thermal network model
原文传递
A Novel Modified Fuzzy-predictive Control of Permanent Magnet Synchronous Generator Based Wind Energy Conversion System
16
作者 Ehsan Akbari Milad Samady Shadlu 《Chinese Journal of Electrical Engineering》 EI CSCD 2023年第4期107-121,共15页
A wind energy conversion system(WECS)based on a permanent magnet synchronous generator(PMSG)is an effective solution for renewable energy generation in modern power systems.The main advantages of PMSG include high per... A wind energy conversion system(WECS)based on a permanent magnet synchronous generator(PMSG)is an effective solution for renewable energy generation in modern power systems.The main advantages of PMSG include high performance at high and low speeds,minimal control effort owing to lower rotor inertia,self-excitation,high reliability,and simplicity of structure compared with induction generators.However,the intermittent nature of wind energy implies that maximum efficiency is not obtained from this system.Accordingly,maximum power point tracking(MPPT)in wind turbine systems has been proposed to address this problem.Traditional MPPT strategies suffer from severe output power fluctuations,low efficiency,and significant ripples in turbine rotation speed.This paper presents a novel MPPT control strategy based on fuzzy logic control(FLC)and model predictive control(MPC)to extract the maximum power from a PMSG-WECS and control the machine-side and grid-side converters.The simulation results obtained from Matlab/Simulink confirm the superiority of the control model in eliminating the output power fluctuations of the wind generators and accurately tracking the maximum power point.A comparative study between conventional MPPT and control methods is also conducted. 展开更多
关键词 Maximum power point tracking(MPPT) wind energy conversion system(WECS) permanent magnet synchronous generator(PMSG) fuzzy logic control(FLC) model predictive control(MPC)
原文传递
Fault Detection Method for Permanent Magnet Synchronous Generator Wind Energy Converters Using Correlation Features Among Three-phase Currents 被引量:2
17
作者 Yanghong Tan Haixia Zhang Ye Zhou 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第1期168-178,共11页
In a permanent magnet synchronous generator(PMSG)system,conversion systems are major points of failure that create expensive and time-consuming problems.Fault detection is usually used to achieve a steady system.This ... In a permanent magnet synchronous generator(PMSG)system,conversion systems are major points of failure that create expensive and time-consuming problems.Fault detection is usually used to achieve a steady system.This paper presents a full analysis of a PMSG system for wind turbines(WT)and proposes a fault detection method using correlation features.The proposed method is motivated by the balance among the three-phase currents both before and after an opencircuit fault occurs in a converter of the PMSG system.It is unnecessary to analyze the output waveforms of a converter during fault detection.In this study,two correlation features of stator currents,the mean and covariation,are extracted to train an artificial neural network(ANN),thereby enhancing the performance of the proposed method under different wind speed conditions.Moreover,additional sensors and the collection of a massive amount of data are not required.Model simulations of an ideal inverter and a PMSG system are conducted using PSCAD software.The simulation results show that the proposed method can detect the locations of faulty switches with a diagnostic rate greater than 99.4%for the ideal inverter,and the PMSG drives settings at different wind speeds. 展开更多
关键词 permanent magnet synchronous generator(PMSG) artificial neural network(ANN) mixed logical dynamical(MLD)theory conversion system
原文传递
Robust nonlinear control via feedback linearization and Lyapunov theory for permanent magnet synchronous generator-based wind energy conversion system 被引量:2
18
作者 Ridha CHEIKH Arezki MENACER +1 位作者 L.CHRIFI-ALAOUI Said DRID 《Frontiers in Energy》 SCIE CSCD 2020年第1期180-191,共12页
In this paper,the method for the nonlinear control design of a permanent magnet synchronous generator based-wind energy conversion system(WECS)is proposed in order to obtain robustness against disturbances and harvest... In this paper,the method for the nonlinear control design of a permanent magnet synchronous generator based-wind energy conversion system(WECS)is proposed in order to obtain robustness against disturbances and harvest a maximum power from a typical stochastic wind environment.The technique overcomes both the problem of nonlinearity and the uncertainty of the parameter compared to such classical control designs based on traditional control techniques.The method is based on the differential geometric feedback linearization technique(DGT)and the Lyapunov theory.The results obtained show the effectiveness and performance of the proposed approach. 展开更多
关键词 permanent magnet synchronous generator wind energy conversion system stochastic differential GEOMETRIC feedback LINEARIZATION maximum power point tracking LYAPUNOV robust control
原文传递
Wide Speed Range Permanent Magnet Synchronous Generator Design for a DC Power System 被引量:3
19
作者 Dongmin Miao Yves Mollet +1 位作者 Johan Gyselinck Jianxin Shen 《Chinese Journal of Electrical Engineering》 CSCD 2017年第1期33-41,共9页
A wide speed range permanent magnet synchronous generator(PMSG)system is studied in this paper,including the PMSG design and comparative study on control strategies with a pulse width modulation(PWM)rectifier,the purp... A wide speed range permanent magnet synchronous generator(PMSG)system is studied in this paper,including the PMSG design and comparative study on control strategies with a pulse width modulation(PWM)rectifier,the purpose of which is to regulate the DC-link voltage.It is of great importance to study the foregoing DC power system based on the PMSG and PWM rectifier,where vector control(VC)can be implemented and the corresponding field-weakening strategy can be realized by injecting a field-weakening current component without any auxiliary devices.Large machine inductance is desired in order to limit the short-circuit current and the loaded voltage drop.Different control strategies including VC,direct torque control(DTC)and direct voltage control(DVC)are studied and compared with both simulations and experiments. 展开更多
关键词 Wide speed range permanent magnet synchronous generator PWM rectifier vector control field-weakening control direct torque control direct voltage control
原文传递
Control Strategy of Wind Turbine Based on Permanent Magnet Synchronous Generator and Energy Storage for Stand-Alone Systems 被引量:2
20
作者 Fujin Deng Dong Liu +1 位作者 Zhe Chen Peng Su 《Chinese Journal of Electrical Engineering》 CSCD 2017年第1期51-62,共12页
This paper investigates a variable speed wind turbine based on permanent magnet synchronous generator and a full-scale power converter in a stand-alone system.An energy storage system(ESS)including battery and fuel ce... This paper investigates a variable speed wind turbine based on permanent magnet synchronous generator and a full-scale power converter in a stand-alone system.An energy storage system(ESS)including battery and fuel cell-electrolyzer combination is connected to the DC link of the full-scale power converter through the power electronics interface.Wind is the primary power source of the system,the battery and FC-electrolyzer combination is used as a backup and a long-term storage system to provide or absorb power in the stand-alone system,respectively.In this paper,a control strategy is proposed for the operation of this variable speed wind turbine in a stand-alone system,where the generator-side converter and the ESS operate together to meet the demand of the loads.This control strategy is competent for supporting the variation of the loads or wind speed and limiting the DC-link voltage of the full-scale power converter in a small range.A simulation model of a variable speed wind turbine in a stand-alone system is developed using the simulation tool of PSCAD/EMTDC.The dynamic performance of the stand-alone wind turbine system and the proposed control strategy is assessed and emphasized with the simulation results. 展开更多
关键词 Variable speed wind turbine(VSWT) permanent magnet synchronous generator(PMSG) stand-alone system energy storage system(ESS).
原文传递
上一页 1 2 50 下一页 到第
使用帮助 返回顶部