期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Analysis of Effects of the Arc Voltage on Arc Discharges in a Cathode Ion Source of Neutral Beam Injector
1
作者 陈俞钱 胡纯栋 谢亚红 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第4期453-456,共4页
A hot cathode bucket ion source is used for the EAST(experimental advanced superconducting tokamak)neutral beam injector.The thermal electrons emitted from the surface of the cathode are extracted and accelerated by... A hot cathode bucket ion source is used for the EAST(experimental advanced superconducting tokamak)neutral beam injector.The thermal electrons emitted from the surface of the cathode are extracted and accelerated by the electric field formed by the arc voltage,which is applied between the arc chamber of the ion source and the cathode.This paper analyzes the effects of arc voltage on the arc discharge in a hot cathode high current ion source. 展开更多
关键词 high current ion source arc discharge thermal emission limited mode stability
下载PDF
Feedback model of secondary electron emission in DC gas discharge plasmas
2
作者 Saravanan ARUMUGAM Prince ALEX Suraj Kumar SINHA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第2期128-133,共6页
Feedback is said to exist in any amplifier when the fraction of output power in fed back as an input.Similarly,in gaseous discharge ions that incident on the cathode act as a natural feedback element to stabilize and ... Feedback is said to exist in any amplifier when the fraction of output power in fed back as an input.Similarly,in gaseous discharge ions that incident on the cathode act as a natural feedback element to stabilize and self sustain the discharge.The present investigation is intended to emphasize the feedback nature of ions that emits secondary electrons(SEs)from the cathode surface in DC gas discharges.The average number of SEs emitted per incident ion and non ionic species(energetic neutrals,metastables and photons)which results from ion is defined as effective secondary electronemission coefficient(ESEEC,Eg).In this study,we derive an analytic expression that corroborates the relation betweenEg and power influx by ion to the cathode based on the feedback theory of an amplifier.In addition,experimentally,we confirmed the typical positive feedback nature of SEEfrom the cathode in argon DC glow discharges.The experiment is done for three different cathode material of same dimension(tungsten(W),copper(Cu)and brass)under identical discharge conditions(pressure:0.45 mbar,cathode bias:-600 V,discharge gab:15 cm and operating gas:argon).Further,we found that theEg value of these cathode material controls the amount of feedback power given by ions.The difference in feedback leads different final output i.e the power carried by ion at cathode(Pi C¢∣).The experimentally obtained value of Pi C¢∣is 4.28 W,6.87 W and9.26 W respectively for W,Cu and brass.In addition,the present investigation reveals that the amount of feedback power in a DC gas discharges not only affect the fraction of power fed back to the cathode but also the entire characteristics of the discharge. 展开更多
关键词 feedback secondary electron emission DC gas discharges power influx by ion at cathode cathode temperature
下载PDF
Diagnosis of Hydrogen Plasma in a Miniature Penning Ion Source by Double Probes 被引量:1
3
作者 金大志 杨中海 +1 位作者 肖坤祥 戴晶怡 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第1期48-51,共4页
Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron dens... Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron density increases and the electron temperature decreases with the increase in gas pressure and the discharge current. The electron temperature is about 5 - 9 eV and the electron density is 6.0× 10^13 ~ 1.2 × 10^14 m^-3 while the discharge current is in a range of 50 - 120 μA. 展开更多
关键词 Penning discharge ion source hydrogen plasma DIAGNOSIS double probes
下载PDF
Novel Application of High Voltage Electrostatics Corona Ions Discharge Related to Treatment, Sanitization and Disinfection of Biological Matter Such HIV-AIDS Infected Blood
4
作者 HAMADE Thomas A. 《Journal of Shanghai Jiaotong university(Science)》 EI 2018年第1期112-121,共10页
A novel high-voltage electrostatics corona ions pre-charger apparatus and methods were invented earlier by Hamade related to treat various types of receptors such as but not limited to electret polymer, air filters, p... A novel high-voltage electrostatics corona ions pre-charger apparatus and methods were invented earlier by Hamade related to treat various types of receptors such as but not limited to electret polymer, air filters, particulates, catalytic converters, bioaerosols, fluids, pollutants, virus, and bacteria. It is shown in this article that his work led to the construction of various prototype chargers, customized differently for each type of a receptor. In particular his recent development of biological matter corona charger(BMCC) prototype related to expose, treat, sanitize, and disinfect bioaerosols, virus, bacteria, and contaminated fluids and blood such as human immunodeficiency virus(HIV)-acquired immune deficiency syndrome(AIDS). It is shown in this paper that each previous investigated research contemplated ionized corona charger attendant to a charging process and the corona, imparts and provides enough treatment charges to receptors including the aforementioned receptors.Researchers often relied on adopting prior corona charger methods that do not necessarily and effectively solve the problems associated with them or utilize them for optimum treatment effect. The inventor exhaustively studied the characteristics of corona discharge, and has found that the greatest difficulty in corona discharge has to do with the maintenance of the corona, particularly when the receptor is being charged. This is due to variations in either the dielectric value between the corona electrode and a grounded base or flaws in the design as the receptor passes there between suppressing or hindering corona and its effectiveness. What is needed in-the-art is an apparatus and method to achieve maximum possible charge on a receptor, a charge order of magnitude greater than that used by other investigators. This often requires customizing each apparatus and method and does not just merely use one type of a charger to satisfy all applications. To satisfy this need, we build a low cost prototype BMCC that generates self-sustaining charge corona, eliminates many previous design flaws such as spark over, and make it ready for testing remotely or with apparatus. 展开更多
关键词 high voltage corona ions discharge DISINFECTion acquired immune deficiency syndrome(AIDS) infected blood electret emission catalytic converter
原文传递
Ion resonance causes striations in electronegative rf glow discharges
5
《Science Foundation in China》 CAS 2016年第4期33-33,共1页
With the support by the National Natural Science Foundation of China,Dr Liu Yongxin(刘永新)and his coworkers at the Key Laboratory of Materials Modification by Laser,Ion,and Electron Beams(Ministry of Education),Schoo... With the support by the National Natural Science Foundation of China,Dr Liu Yongxin(刘永新)and his coworkers at the Key Laboratory of Materials Modification by Laser,Ion,and Electron Beams(Ministry of Education),School of Physics and Optoelectronic Technology,Dalian University of Technology,observed,for the first time,the self-organized striated structures of the plasma emission in 展开更多
关键词 TIME 刘永新 ion resonance causes striations in electronegative rf glow discharges
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部