期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Partial Discharge Measurement and Analysis in High Voltage IGBT Modules Under DC Voltage 被引量:10
1
作者 Pengyu Fu Zhibin Zhao +4 位作者 Xiang Cui Teng Wen Haoyu Wang Xuebao Li Peng Zhang 《CSEE Journal of Power and Energy Systems》 SCIE 2018年第4期513-523,共11页
Insulation performance of high voltage IGBT modules is one of the key attributes in power system applications.However,the existing standards of IGBT devices and research on the evaluation of insulation performance of ... Insulation performance of high voltage IGBT modules is one of the key attributes in power system applications.However,the existing standards of IGBT devices and research on the evaluation of insulation performance of high voltage IGBT modules are insufficient;for example,partial discharge resistance under DC voltage blocking condition is not considered.In this paper,a new test was proposed to allow the measurement of partial discharges in all the components of IGBT modules under DC voltage.The topology of the measuring circuit is arranged in the polarity discrimination way to exclude the interference,and the voltage and discharge current waveforms during the partial discharge process are measured by the wideband time domain measurement technique.According to the proposed test,the discharge phenomenon of the IGBT modules below the rating voltage were detected.A comprehensive waveform analysis on the voltage and discharge current was performed,and the influence of the applied voltage on the waveform parameters was obtained.The waveform parameters are influenced by the applied voltage and insulation structure,which enables the discrimination of the causes of the observed partial discharge in the IGBT module under DC voltage by the waveform analysis technique.Based on the waveform analysis technique,the types and causes of the observed partial discharges were discussed and inferred,and the correctness of the inference was further verified by observation.The proposed test and waveform analysis technique provide the possibility to evaluate and distinguish partial discharges in the high voltage IGBT module under DC voltage,which may be helpful to insulation performance evaluation and insulation defect diagnosis in high voltage IGBT module. 展开更多
关键词 DC voltage high voltage IGBT module insulation performance partial discharge measurement waveform analysis wideband time domain measurement
原文传递
Surface potential uniformity and sensitivity of large-area PTFE electret discs of different thicknesses produced by a modified corona poling rotating system for dosimetry applications
2
作者 A.Komeijani H.Bagheri B.Shekarchi 《Journal of Advanced Dielectrics》 CAS 2019年第6期52-62,共11页
In this study,large-area(6-cm diameter)Teflon polytetrafluoroethylene(PTFE)discs of different thicknesses(0.2-,0.5-and 1-mm)were negatively and positively charged by using the“modified single point-to-plane corona po... In this study,large-area(6-cm diameter)Teflon polytetrafluoroethylene(PTFE)discs of different thicknesses(0.2-,0.5-and 1-mm)were negatively and positively charged by using the“modified single point-to-plane corona poling rotating system”.The effects of some crucial parameters of the PTFE disc as well as the modified corona poling rotating system on the PTFE surface potential uniformity such as.(a)PTFE disc thickness,(b)PTFE disc polarity and(c)needle-to-PTFE disc distance were successfully reported.Accordingly,closer needle-to-PTFE disc distance,positive charging mode and thinner PTFE disc provided a better PTFE surface potential uniformity.However,the effects of PTFE charge polarity and needle distance on the electrostatic charge potential uniformity were much more remarkable in comparison with the effects of PTFE thickness.Additionally,the surface potential distribution profiles of charged PTFE discs were totally flat and independent of the PTFE thickness at 5-and 13-mm needle distances for the negative and positive charging modes,respectively.At the optimized charging conditions,large-area PTFE electret disc(0.5-mm-thick)with positive uniform surface charge potential especially at the edges up to1.8 kV with stability up to 77 days studied was produced by applying a new multiple heat treatment protocol to the PTFE disc for radon dosimetry.As also observed in this study,the sensitivity of PTFE electret dosimeters to a defined radon gas concentration increases as the PTFE thickness increases.Meanwhile,0.5-mm-thick PTFE electret disc produced was selected to be used as a high quality electret dosimeter with acceptable and superior parameters for different applications in particular medium-term radiation dosimetry in both low and high dose rate ionizing radiation fields. 展开更多
关键词 PTFE electrets dielectric polarization surface charge uniformity and stability electrostatic discharges and measurements DOSIMETRY
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部