期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Repetitive transcranial magnetic stimulation improves consciousness disturbance in stroke patients A quantitative electroencephalography spectral power analysis 被引量:2
1
作者 Ying Xie Tong Zhang 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第31期2465-2472,共8页
Repetitive transcranial magnetic stimulation is a noninvasive treatment technique that can directly alter cortical excitability and improve cerebral functional activity in unconscious patients. To investigate the effe... Repetitive transcranial magnetic stimulation is a noninvasive treatment technique that can directly alter cortical excitability and improve cerebral functional activity in unconscious patients. To investigate the effects and the electrophysiological changes of repetitive transcranial magnetic stimulation cortical treatment, 10 stroke patients with non-severe brainstem lesions and with disturbance of consciousness were treated with repetitive transcranial magnetic stimulation. A quantitative electroencephalography spectral power analysis was also performed. The absolute power in the alpha band was increased immediately after the first repetitive transcranial magnetic stimulation treatment, and the energy was reduced in the delta band. The alpha band relative power values slightly decreased at 1 day post-treatment, then increased and reached a stable level at 2 weeks post-treatment. Glasgow Coma Score and JFK Coma Recovery Scale-Revised score were improved. Relative power value in the alpha band was positively related to Glasgow Coma Score and JFK Coma Recovery Scale-Revised score. These data suggest that repetitive transcranial magnetic stimulation is a noninvasive, safe, and effective treatment technology for improving brain functional activity and promoting awakening in unconscious stroke patients. 展开更多
关键词 repetitive transcranial magnetic stimulation consciousness disturbance stroke quantitative electroencephalography nervous excitation consciousness neuroregenerative disease regeneration neural regeneration
下载PDF
Non-invasive determination of hepatic steatosis by acoustic structure quantification from ultrasound echo amplitude 被引量:15
2
作者 Hidekatsu Kuroda Keisuke Kakisaka +7 位作者 Naohisa Kamiyama Takayoshi Oikawa Mio Onodera Kei Sawara Kanta Oikawa Ryujin Endo Yasuhiro Takikawa Kazuyuki Suzuki 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第29期3889-3895,共7页
AIM:To use leptin-deficient(ob/ob) mice with demonstrated differences in steatosis levels to test a new diagnostic method using the acoustical structure quantification(ASQ) mode and the associated analytical parameter... AIM:To use leptin-deficient(ob/ob) mice with demonstrated differences in steatosis levels to test a new diagnostic method using the acoustical structure quantification(ASQ) mode and the associated analytical parameter,"focal disturbance ratio"(FD-ratio).METHODS:Nine ob/ob mice,at 5,8,and 12 wk of age(n = 3 in each age group),were used as models for hepatic steatosis.Echo signals obtained from ultrasonography in the mice were analyzed by ASQ,which uses a statistical analysis of echo amplitude to estimate inhomogeneity in the diagnostic region.FD-ratio,as calculated from this analysis,was the focus of the present study.FD-ratio and fat droplet areas and sizes were compared between age groups.RESULTS:No fibrosis or inflammation was observed in any of the groups.The fat droplet area significantly(P < 0.01) increased with age from 1.25% ± 0.28% at 5 wk to 31.07% ± 0.48% at 8 wk to 51.69% ± 3.19% at 12 wk.The median fat droplet size also significantly(P < 0.01) increased with age,from 1.33(0.55-10.52) m at 5 wk,2.82(0.61-44.13) m at 8 wk and 6.34(0.66-81.83) m at 12 wk.The mean FD-ratio was 0.42 ± 0.11 at 5 wk,0.11 ± 0.05 at 8 wk,and 0.03 ± 0.02 at 12 wk.The FD-ratio was significantly lower at 12 wk than at 5 wk and 8 wk(P < 0.01).A significant negative correlation was observed between the FD-ratio and either the fat droplet area(r =-0.7211,P = 0.0017) or fat droplet size(r =-0.9811,P = 0.0052).CONCLUSION:This tool for statistical analysis of signals from ultrasonography using the FD-ratio can be used to accurately quantify fat in vivo in an animal model of hepatic steatosis,and may serve as a quantitative biomarker of hepatic steatosis. 展开更多
关键词 Non-alcoholic fatty liver disease Quantitation of hepatic steatosis Animal model Focal disturbance ratio Acoustic structure quantification Ultrasonography
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部