This survey was designed to assess the sanitation status of hospitals and the compliance of hospital staff to disinfection strategies within the past 11 years.A total of 199 provincial affiliated tertiary or secondary...This survey was designed to assess the sanitation status of hospitals and the compliance of hospital staff to disinfection strategies within the past 11 years.A total of 199 provincial affiliated tertiary or secondary public hospitals from 2007 to 2017 were investigated and seven critical categories,namely indoor air,work surface,hand hygiene,ultraviolet(UV) irradiation intensity,use of disinfectants,sterilization of medical items,and effects of steam sterilizer,were monitored.The average qualified rates were(94.74±3.54)%(810/855),(97.25±1.65)%(1 876/1 929),(87.57±4.60)%(2 508/2 864),(95.00±4.50)%(1 196/1 259),and(98.76±1.14)%(1 599/1 619) for indoor air,work surface,hand hygiene,UV irradiation intensity,and sterilization of medical items,respectively.In terms of other categories,a few samples were not qualified:3/1 575 for use of disinfectants and 1/243 for effects of steam sterilizer.The hospital disinfection monitoring and supervision program effectively improved the effectiveness of disinfection.Routine monitoring and supervision must be conducted to ensure a safe hospital treatment environment.展开更多
目的研究以过滤、紫外线和光催化等因子组合的空气消毒器消毒相关性能。方法采用空气微生物采样器采样和检测方法进行了实验室试验和现场消毒试验。结果在20 m3气雾室内开机运行60 m in,对人工污染在空气中的白色葡萄球菌的杀灭率各次...目的研究以过滤、紫外线和光催化等因子组合的空气消毒器消毒相关性能。方法采用空气微生物采样器采样和检测方法进行了实验室试验和现场消毒试验。结果在20 m3气雾室内开机运行60 m in,对人工污染在空气中的白色葡萄球菌的杀灭率各次均达到99.94%以上。在48 m3的房间现场试验条件下,开机运行60 m in对室内空气中自然菌的消除率均达到95.49%以上;在有3人活动的20 m3气雾室内,开机运行60 m in后对空气中细菌的杀灭率均达到95.55%以上。结论该多因子组合空气消毒器在实验室和现场消毒试验条件下都具有良好的除菌效果,并具有人在条件下持续性消毒功能。展开更多
文摘This survey was designed to assess the sanitation status of hospitals and the compliance of hospital staff to disinfection strategies within the past 11 years.A total of 199 provincial affiliated tertiary or secondary public hospitals from 2007 to 2017 were investigated and seven critical categories,namely indoor air,work surface,hand hygiene,ultraviolet(UV) irradiation intensity,use of disinfectants,sterilization of medical items,and effects of steam sterilizer,were monitored.The average qualified rates were(94.74±3.54)%(810/855),(97.25±1.65)%(1 876/1 929),(87.57±4.60)%(2 508/2 864),(95.00±4.50)%(1 196/1 259),and(98.76±1.14)%(1 599/1 619) for indoor air,work surface,hand hygiene,UV irradiation intensity,and sterilization of medical items,respectively.In terms of other categories,a few samples were not qualified:3/1 575 for use of disinfectants and 1/243 for effects of steam sterilizer.The hospital disinfection monitoring and supervision program effectively improved the effectiveness of disinfection.Routine monitoring and supervision must be conducted to ensure a safe hospital treatment environment.
文摘目的研究以过滤、紫外线和光催化等因子组合的空气消毒器消毒相关性能。方法采用空气微生物采样器采样和检测方法进行了实验室试验和现场消毒试验。结果在20 m3气雾室内开机运行60 m in,对人工污染在空气中的白色葡萄球菌的杀灭率各次均达到99.94%以上。在48 m3的房间现场试验条件下,开机运行60 m in对室内空气中自然菌的消除率均达到95.49%以上;在有3人活动的20 m3气雾室内,开机运行60 m in后对空气中细菌的杀灭率均达到95.55%以上。结论该多因子组合空气消毒器在实验室和现场消毒试验条件下都具有良好的除菌效果,并具有人在条件下持续性消毒功能。