To utilize exist SCADA(Supervisory Control and Data Acqui si tion)/EMS (Energy Management System) fully and economize capital, Henan Electric Power Dispatching and Communication Center in China established a set of H...To utilize exist SCADA(Supervisory Control and Data Acqui si tion)/EMS (Energy Management System) fully and economize capital, Henan Electric Power Dispatching and Communication Center in China established a set of Henan Dispatcher Training Simulator (HNDTS) base on its exist SCADA/EMS. In order to i ntegrated with exist SCADA/EMS, the integration method and technique are propose d. Graph data integration discussed with emphasis. After integration implemented , HNDTS can share all data with SCADA/EMS and dispatchers can be trained in same environment as real work situation, in the same time it can avoid amout of work of maintenance engineers. Both advantages and disadvantages of integration are analyzed. In the end of paper, the requirement for future DTS is put forward bas e on the experience of author.展开更多
A fault management dispatcher training simulator for large-scale Distribution Automation System (TDAS) is developed to train operators in distribution control center. This simulator is composed of independent simulati...A fault management dispatcher training simulator for large-scale Distribution Automation System (TDAS) is developed to train operators in distribution control center. This simulator is composed of independent simulation server and operator consoles and can be used for network analysis, network operation, fault management and evaluation. TDAS DB is duplicated online to the simulation server keeping the data security. The system can model distribution network penetrated with distributed generations (DG) using the real data from the TDAS DB. Network fault scenarios are automatically generated by calculating fault current and generating fault indicators. Also, manual entry of cry wolf alarm is available. Moreover, operation solution for scenario of fault isolation and service restoration is generated automatically so that trainee can check their operation result. Operator actions during training session are saved and can be played back as well as displayed on one-line diagram pictures.展开更多
文摘To utilize exist SCADA(Supervisory Control and Data Acqui si tion)/EMS (Energy Management System) fully and economize capital, Henan Electric Power Dispatching and Communication Center in China established a set of Henan Dispatcher Training Simulator (HNDTS) base on its exist SCADA/EMS. In order to i ntegrated with exist SCADA/EMS, the integration method and technique are propose d. Graph data integration discussed with emphasis. After integration implemented , HNDTS can share all data with SCADA/EMS and dispatchers can be trained in same environment as real work situation, in the same time it can avoid amout of work of maintenance engineers. Both advantages and disadvantages of integration are analyzed. In the end of paper, the requirement for future DTS is put forward bas e on the experience of author.
文摘A fault management dispatcher training simulator for large-scale Distribution Automation System (TDAS) is developed to train operators in distribution control center. This simulator is composed of independent simulation server and operator consoles and can be used for network analysis, network operation, fault management and evaluation. TDAS DB is duplicated online to the simulation server keeping the data security. The system can model distribution network penetrated with distributed generations (DG) using the real data from the TDAS DB. Network fault scenarios are automatically generated by calculating fault current and generating fault indicators. Also, manual entry of cry wolf alarm is available. Moreover, operation solution for scenario of fault isolation and service restoration is generated automatically so that trainee can check their operation result. Operator actions during training session are saved and can be played back as well as displayed on one-line diagram pictures.