To enhance the applicability and measurement accuracy of phase-based optical flow method using complex steerable pyramids in structural displacement measurement engineering applications, an improved method of optimizi...To enhance the applicability and measurement accuracy of phase-based optical flow method using complex steerable pyramids in structural displacement measurement engineering applications, an improved method of optimizing parameter settings is proposed. The optimized parameters include the best measurement points of the Region of Interest (ROI) and the levels of pyramid filters. Additionally, to address the issue of updating reference frames in practical applications due to the difficulty in estimating the maximum effective measurement value, a mechanism for dynamically updating reference frames is introduced. Experimental results demonstrate that compared to representative image gradient-based displacement measurement methods, the proposed method exhibits higher measurement accuracy in engineering applications. This provides reliable data support for structural damage identification research based on vibration signals and is expected to broaden the engineering application prospects for structural health monitoring.展开更多
Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement trans...Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement transformation coefficient(DTC)of an LVDMM changes with the coordinates in the camera image coordinate system during the displacement measuring process,and these changes affect the displacement measurement accuracy of LVDMMs in the full field of view(FFOV).To give LVDMMs higher accuracy in the FFOV and make them adaptable to widely varying measurement demands,a new calibration method is proposed to improve the displacement measurement accuracy of LVDMMs in the FFOV.First,an image coordinate system,a pixel measurement coordinate system,and a displacement measurement coordinate system are established on the laser receiving screen of the LVDMM.In addition,marker spots in the FFOV are selected,and the DTCs at the marker spots are obtained from calibration experiments.Also,a fitting method based on locally weighted scatterplot smoothing(LOWESS)is selected,and with this fitting method the distribution functions of the DTCs in the FFOV are obtained based on the DTCs at the marker spots.Finally,the calibrated distribution functions of the DTCs are applied to the LVDMM,and experiments conducted to verify the displacement measurement accuracies are reported.The results show that the FFOV measurement accuracies for horizontal and vertical displacements are better than±15μm and±19μm,respectively,and that for oblique displacement is better than±24μm.Compared with the traditional calibration method,the displacement measurement error in the FFOV is now 90%smaller.This research on an improved calibration method has certain significance for improving the measurement accuracy of LVDMMs in the FFOV,and it provides a new method and idea for other vision-based fields in which camera parameters must be calibrated.展开更多
Three dimensional(3D) displacements, which can be translated further into 3D strain, are key parameters tor design, manufacturing and quality control. Using different optical setups, phase-shift methods, and algorit...Three dimensional(3D) displacements, which can be translated further into 3D strain, are key parameters tor design, manufacturing and quality control. Using different optical setups, phase-shift methods, and algorithms, several different 3D electronic speckle pattern interferometry(ESPl) systems for displacement and strain measurements have been achieved and commercialized. This paper provides a review of the recent developments in ESPI systems for 3D displacement and strain measurement. After an overview of the fundamentals of ESP! theory, temporal phase-shift, and spatial phase-shift techniques, 3D deformation measurements by the temporal phase-shift ESPI system, which is suited well for static measurement, and by the spatial phase-shift ESPI system, which is particularly useful for dynamic measurement, are discussed. For each method, the basic theory, a brief derivation and different optical layouts are presented. The state of art application, potential and limitation of the ESPI systems are shown and demonstrated.展开更多
We propose a novel system for synchronous measurement of out-of-plane deformation and two orthogonal slopes using a single camera. The linearly polarized reference beam introduced by an optical fiber interferes with t...We propose a novel system for synchronous measurement of out-of-plane deformation and two orthogonal slopes using a single camera. The linearly polarized reference beam introduced by an optical fiber interferes with the unpolarized object beam to measure the out-of-plane deformation. A modified Mach–Zehnder interferometer is used to measure the two orthogonal slopes of the out-of-plane deformation. One of the object beams of the Mach–Zehnder interferometer is an unpolarized beam, and the other object beam is split into two orthogonal linearly polarized object beams by a polarizing prism. The two beams are orthogonally polarized. Hence, they will not interfere with each other. The two polarized beams respectively interfere with the unpolarized beam to simultaneously measure the two orthogonal slopes of the out-of-plane deformation. In addition, the imaging lens and apertures are respectively placed in three optical paths to independently control the carrier frequencies and shearing amounts. The effectiveness of this method can be proved by measuring two pressure-loaded circular plates.展开更多
The effectiveness of monitoring and early-warning systems for ground deformation phenomena,such as sinkholes,depends on their ability to accurately resolve the ongoing ground displacement and detect the subtle deforma...The effectiveness of monitoring and early-warning systems for ground deformation phenomena,such as sinkholes,depends on their ability to accurately resolve the ongoing ground displacement and detect the subtle deformation preceding catastrophic failures.Sagging sinkholes with a slow subsidence rate and diffuse edges pose a significant challenge for subsidence monitoring due to the low deformation rates and limited lateral strain gradients.In this work,we satisfactorily illustrate the practicality of the Brillouin optical time domain analysis(BOTDA)to measure the spatial-temporal patterns of the vertical displacement in such challenging slow-moving sagging sinkholes.To assess the performance of the approach,we compare the strain recorded by the distributed optical fiber sensor with the vertical displacement measured by high-precision leveling.The results show a good spatial correlation with the ability to identify the maximum subsidence point.There is also a good temporal correlation with the detection of an acceleration phase in the subsidence associated with a flood event.展开更多
The sampling Moiré(SM) method is one of the vision-based non-contact deformation measurement methods, which is a powerful tool for structural health monitoring and elucidation of damage mechanisms of materials. I...The sampling Moiré(SM) method is one of the vision-based non-contact deformation measurement methods, which is a powerful tool for structural health monitoring and elucidation of damage mechanisms of materials. In this review, the basic principle of the SM method for measuring the twodimensional displacement and strain distributions is introduced. When the grid is not a standard orthogonal grating and cracks exist on the specimen surface, the measurement methods are also stated. Two of the most typical application examples are described in detail. One is the dynamic deflection measurement of a large-scale concrete bridge, and the other is the residual thermal strain measurement of small-scale flip chip packages. Several further development points of this method are pointed out. The SM method is expected to be used for deformation measurement of various structures and materials for residual stress evaluation, crack location prediction, and crack growth evaluation on broad scales.展开更多
Three-dimensional(3D)microdisplacement monitoring plays a crucial role in the assembly of large aircraft.This paper presents a broadly applicable high-precision online 3D microdisplacement monitoring method and system...Three-dimensional(3D)microdisplacement monitoring plays a crucial role in the assembly of large aircraft.This paper presents a broadly applicable high-precision online 3D microdisplacement monitoring method and system based on proximity sensors as well as a corresponding in situ calibration method,which can be applied under various extreme working conditions encountered in the aircraft assembly process,such as compact and obstructed spaces.A 3D monitoring model is first established to achieve 3D microdisplacement monitoring based only on the one-dimensional distances measured by proximity sensors,which concerns the extrinsic sensor parameters,such as the probe base point(PBP)and the unit displacement vector(UDV).Then,a calibration method is employed to obtain these extrinsic parameters with high precision by combining spatial transformation principles and weighted optimization.Finally,calibration and monitoring experiments performed for a tailplane assembly process are reported.The calibration precision for the PBP is better than±10 lm in the X and Y directions and±2 lm in the Z direction,and the calibration precision for the UDV is better than 0.07°.Moreover,the accuracy of the 3D microdisplacement monitoring system can reach±15 lm.In general,this paper provides new insights into the modeling and calibration of 3D microdisplacement monitoring based on proximity sensors and a precise,efficient,and low-cost technical means for performing related measurements in compact spaces during the aircraft assembly process.展开更多
Based on laser-scanned measuring technology, a met ho d of on-line dynamic non-contact measurement and feedback control of processin g dimension, i.e. the double edges laser-scanned large diameter on-line dynami c mea...Based on laser-scanned measuring technology, a met ho d of on-line dynamic non-contact measurement and feedback control of processin g dimension, i.e. the double edges laser-scanned large diameter on-line dynami c measurement and control system is presented, which can be used to measure diam eter in large-scale machine part processing. In this paper, the working princip le, overall structure and microcomputer real-time control and data processing s ystem of the system are discussed in detail, the method of double edges scanned large diameter dimension measurement and control is theoretically analyzed, its possibility has been verified by experiments of lathing large diameters machine parts by a vertical lathe. The system adopts the measuring scheme of double edge s laser-scanned combined with grating displacement measurement. The two edges c haracteristic information of the measured diameter is given by the double edges laser-scanned measuring system, the non-contact measurement of large diameter dimension is realized to combine with the grating displacement measuring systems . The main controller gives out feedback control signal by means of measured res ults, and controls advance and retreat of lathe tool by the servo-control syste m of a vertical lathe to realize on-line dynamic non-contact measurement and c ontrol in processing.展开更多
In this Letter,we propose a simple structure of an orthogonal type double Michelson interferometer.The orthogonal detection method overcomes the problems of uneven ranging sensitivity and the inability of traditional ...In this Letter,we propose a simple structure of an orthogonal type double Michelson interferometer.The orthogonal detection method overcomes the problems of uneven ranging sensitivity and the inability of traditional interferometers to determine the displacement direction.The displacement measurement principle and signal processing method of the orthogonal double interferometer are studied.Unlike the arctangent algorithm,the displacement analysis uses the arc cosine algorithm,avoiding any pole limit in the distance analysis process.The minimum step size of the final experimental displacement system is 5 nm,which exhibits good repeatability,and the average error is less than 0.12 nm.展开更多
The compact,sensitive,and multidimensional displacement measurement device plays a crucial role in semiconductor manufacture and high-resolution optical imaging.The metasurface offers a promising solution to develop h...The compact,sensitive,and multidimensional displacement measurement device plays a crucial role in semiconductor manufacture and high-resolution optical imaging.The metasurface offers a promising solution to develop high-precision displacement metrology.In this work,we proposed and experimentally demonstrated a two-dimensional displacement(XZ)measurement device by a dielectric metasurface.Both transversal and longitudinal displacements of the metasurface can be obtained by the analysis of the interference optical intensity that is generated by the deflected light beams while the metasurface is under linearly polarized incidence.We experimentally demonstrated that displacements down to 5.4 nm along the x-axis and 0.12μm along the z-axis can be resolved with a 900μm×900μm metasurface.Our work opens up new possibilities to develop a compact high-precision multidimensional displacement sensor.展开更多
We describe a new method for angular displacement measurements that is based on a Fabry-Perot interferometer. A measurement accuracy of 10-8 rad is obtained by use of the sinusoidal phase modulating interferometry. An...We describe a new method for angular displacement measurements that is based on a Fabry-Perot interferometer. A measurement accuracy of 10-8 rad is obtained by use of the sinusoidal phase modulating interferometry. Another Fabry-Perot interferometer is used to obtain the key initial angle of incidence.展开更多
The numerical moire method with sensitivity as high as 0.03 nm has been presented. A quantitative displacement and strain analysis program has been proposed by using this method. It is applied to an edge dislocation a...The numerical moire method with sensitivity as high as 0.03 nm has been presented. A quantitative displacement and strain analysis program has been proposed by using this method. It is applied to an edge dislocation and a stacking fault in aluminum. The measured strain of edge dislocation is compared with theoretical prediction given by Peierls-Nabarro dislocation model. The displacement of stacking fault is also obtained.展开更多
In this paper, a sinusoidal phase-modulating Fabry-Perot interferometer is proposed to measure angular displacement. The usefulness of the interferometer is demonstrated by simulations and experiments.
This paper presents the anisotropic optical feedback of a single frequency intra-cavity He-Ne laser. A novel phenomenon was discovered that the laser output an elliptical polarized frequency instead of the initial lin...This paper presents the anisotropic optical feedback of a single frequency intra-cavity He-Ne laser. A novel phenomenon was discovered that the laser output an elliptical polarized frequency instead of the initial linear polarized one. Two intensities with a phase difference were detected, both of which were modulated in the form of cosine wave and a fringe shift corresponds to a λ/2 movement of the feedback mirror. The phase difference can be continuously modulated by the wave plate in the external cavity. Frequency stabilization was used to stabilize the laser frequency so as to enlarge the measuring range and improve the measurement precision. This anisotropic optical feedback system offers a potential displacement measurement technology with the function of subdivision of λ/2 and in-time direction judgment. The three-mirror Fabry Perot cavity model is used to present the experimental results. Given the lack of need of lasing adjustment, this full intra-cavity laser can significantly improve the simplicity and stability of the optical feedback system.展开更多
The current research of hydrodynamic bearing in blood pump mainly focuses on the bearing structure design.Compared with the typical plane slider bearing and Rayleigh step bearing,spiral groove bearing has excellent pe...The current research of hydrodynamic bearing in blood pump mainly focuses on the bearing structure design.Compared with the typical plane slider bearing and Rayleigh step bearing,spiral groove bearing has excellent performance in load-carrying capacity.However,the load-carrying capacity would decrease significantly with increasing flow rate in conventional designs.In this paper,the special treatment is made to the upper spiral groove bearing to make sure that both the circulatory flowing and load-carrying capacity are high.Three-dimensional computational fluid dynamics(CFD) models in the space between rotor and shaft are developed by using FLUENT software.Effects of groove number,film height and groove depth on load-carrying capacity of the spiral groove bearings are investigated by orthogonal experiment design.The experimental results show that film height is the most remarkable factor to the load-carrying capacity.The variation tendency of load-carrying capacity reveals that the best combination of geometry is the one with groove number of 8,film height 0.03 mm and groove depth 0.08 mm.The velocity and pressure distributions in spiral groove bearings are also analyzed,and the analysis result shows that the distributions are in conformity with the design of the blood pump based on the principle of hydrodynamic bearing.The displacement of the rotor with the best combination parameters is tested by using laser displacement sensors,the testing result shows that the suspending performance is satisfactory both in axial and radial directions.This research proposes a bearing design method which has sufficient load-carrying capacity to support rotor as an effective passive hydrodynamic bearing.展开更多
ASeblsf-tmraicxti:n gA innteewrf esreelnf-cme ioxcincgu rms iicnr oa -liansteerrf derioodmee t(eLrD b)a sbeyd r eofnl eecxtitnergn tahl ep lhiagshet fmroomdu ala tmioinrr oisr-plirkees etanrtgedet. in front of the ...ASeblsf-tmraicxti:n gA innteewrf esreelnf-cme ioxcincgu rms iicnr oa -liansteerrf derioodmee t(eLrD b)a sbeyd r eofnl eecxtitnergn tahl ep lhiagshet fmroomdu ala tmioinrr oisr-plirkees etanrtgedet. in front of the laser. Sinusoidal phase modulation of the beam is obtained by an electro-optic crystal (EOC) in the external cavity. The phase of the interference signal is demodulated by Fourier analysis method. The combination of the modulation and demodulation decreases the sensitivity of the instru-ment to fluctuations of the laser power and the noise induced by environment. Experimentally, the new micro-interferometer is applied to measure the micro-displacement of a high precision commer-cial PZT with an accuracy of 〈10 nm.展开更多
This paper presents a new optical interferometric system, MMI-T/G, composed of a modified four-beam moire interferometer and a Twyman/Green interferometer. The MMI-T/G system can measure three-dimensional displacement...This paper presents a new optical interferometric system, MMI-T/G, composed of a modified four-beam moire interferometer and a Twyman/Green interferometer. The MMI-T/G system can measure three-dimensional displacement fringe patterns with a single loading on the specimen, and the in-plane and out-of-plane displacement fields can be measured independently and defined clearly. The optical setup has the advantages of structural novelty, flexibility, and high fringe contrast. Moreover, the in-plane displacement sensitivity is twice of that of the normal moire interferometer. The measuring techniques to obtain the fringe patterns and displacement fields using the MMI-T/G system are described. The experimental results of thermal displacement of an electronic device are shown.展开更多
Being the two primary approaches for full-field kinematics measurements, both subset-based local digital image correlation (DIC) and finite element-based global DIC have been extensively studied. Nowadays, most comm...Being the two primary approaches for full-field kinematics measurements, both subset-based local digital image correlation (DIC) and finite element-based global DIC have been extensively studied. Nowadays, most commercial DIC systems employ local DIC algorithm because of its advantages of straight forward principle and higher efficiency. However, several researchers argue that global DIC can provide better displacement results due to the displacement continuity constraint among adjacent elements. As such, thoroughly examining the performance of these two different DIC methods seems to be highly necessary. Here, the random errors associated with local DIC and two global DIC methods are theoretically analyzed at first. Subsequently, based on the same algorithmic details and parameters during analyses of numerical and real experiments, the performance of the different DIC approaches is fairly compared. Theoretical and experimental results reveal that local DIC outperforms its global counterpart in terms of both displacement results and computational efficiency when element (subset) size is no less than 11 pixels.展开更多
The auditory system of mammals enables the perception of sound from our surrounding world.Containing some of the smallest bones in the body,the ear transduces complex acoustic signals with high-temporal sensitivity to...The auditory system of mammals enables the perception of sound from our surrounding world.Containing some of the smallest bones in the body,the ear transduces complex acoustic signals with high-temporal sensitivity to complex mechanical vibrations with magnitudes as small as tens of picometers.Measurements of the shape and acoustically induced motions of different components of the ear are essential if we are to expand our understanding of hearing mechanisms,and also provide quantitative information for the development of numerical ear models that can be used to improve hearing protection,clinical diagnosis,and repair of damaged or diseased ears.We are developing digital holographic methods and instrumentation using an ultra-high speed camera to measure shape and acoustically-induced motions in the middle ear.Specifically we study the eardrum,the first structure of the middle ear which initializes the acoustic-mechanical transduction of sound for hearing.Our measurement system is capable of performing holographic measurement at rates up to 2.1 M frames per second.Two shape measurement modalities had previously been implemented into our holographic systems:(1)a multi-wavelength method with a wavelength tunable laser;and(2)a multi-angle illumination method with a single wavelength laser.In this paper,we present a third method using a miniaturized fringe projection system with a microelectromechanical system(MEMS)mirror.Further,we optimize the processing of large data sets of holographic displacement measurements using a vectorized Pearson's correlation algorithm.We validate and compare the shape and displacement measurements of our methodologies using a National Institute of Standards and Technology(NIST)traceable gauge and sound-activated latex membranes and human eardrums.展开更多
A signal processing method of realizing a large-range displacement measurement in a sinusoidal phase- modulating laser diode interferometer is proposed. The method of obtaining the dynamic value of the effective sinus...A signal processing method of realizing a large-range displacement measurement in a sinusoidal phase- modulating laser diode interferometer is proposed. The method of obtaining the dynamic value of the effective sinusoidal phase-modulating depth is detailed, and the residual amplitude modulation is also taken into account. Numerical simulations and experiments are carried out to compare this method with the traditional one. We prove that, with this method, the sinusoidal phase-modulating laser diode interferometer can realize a centimeter-level displacement measurement range with high precision, which is much better than the traditional method.展开更多
文摘To enhance the applicability and measurement accuracy of phase-based optical flow method using complex steerable pyramids in structural displacement measurement engineering applications, an improved method of optimizing parameter settings is proposed. The optimized parameters include the best measurement points of the Region of Interest (ROI) and the levels of pyramid filters. Additionally, to address the issue of updating reference frames in practical applications due to the difficulty in estimating the maximum effective measurement value, a mechanism for dynamically updating reference frames is introduced. Experimental results demonstrate that compared to representative image gradient-based displacement measurement methods, the proposed method exhibits higher measurement accuracy in engineering applications. This provides reliable data support for structural damage identification research based on vibration signals and is expected to broaden the engineering application prospects for structural health monitoring.
基金supported financially by the National Natural Science Foundation of China (NSFC) (Grant No.51775378)the Key Projects in Tianjin Science&Technology Support Program (Grant No.19YFZC GX00890).
文摘Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement transformation coefficient(DTC)of an LVDMM changes with the coordinates in the camera image coordinate system during the displacement measuring process,and these changes affect the displacement measurement accuracy of LVDMMs in the full field of view(FFOV).To give LVDMMs higher accuracy in the FFOV and make them adaptable to widely varying measurement demands,a new calibration method is proposed to improve the displacement measurement accuracy of LVDMMs in the FFOV.First,an image coordinate system,a pixel measurement coordinate system,and a displacement measurement coordinate system are established on the laser receiving screen of the LVDMM.In addition,marker spots in the FFOV are selected,and the DTCs at the marker spots are obtained from calibration experiments.Also,a fitting method based on locally weighted scatterplot smoothing(LOWESS)is selected,and with this fitting method the distribution functions of the DTCs in the FFOV are obtained based on the DTCs at the marker spots.Finally,the calibrated distribution functions of the DTCs are applied to the LVDMM,and experiments conducted to verify the displacement measurement accuracies are reported.The results show that the FFOV measurement accuracies for horizontal and vertical displacements are better than±15μm and±19μm,respectively,and that for oblique displacement is better than±24μm.Compared with the traditional calibration method,the displacement measurement error in the FFOV is now 90%smaller.This research on an improved calibration method has certain significance for improving the measurement accuracy of LVDMMs in the FFOV,and it provides a new method and idea for other vision-based fields in which camera parameters must be calibrated.
基金supported by National Natural Science Foundation of China(Grant Nos.51275054,51075116)
文摘Three dimensional(3D) displacements, which can be translated further into 3D strain, are key parameters tor design, manufacturing and quality control. Using different optical setups, phase-shift methods, and algorithms, several different 3D electronic speckle pattern interferometry(ESPl) systems for displacement and strain measurements have been achieved and commercialized. This paper provides a review of the recent developments in ESPI systems for 3D displacement and strain measurement. After an overview of the fundamentals of ESP! theory, temporal phase-shift, and spatial phase-shift techniques, 3D deformation measurements by the temporal phase-shift ESPI system, which is suited well for static measurement, and by the spatial phase-shift ESPI system, which is particularly useful for dynamic measurement, are discussed. For each method, the basic theory, a brief derivation and different optical layouts are presented. The state of art application, potential and limitation of the ESPI systems are shown and demonstrated.
基金Project supported by the National Key Research and Development Program of China (Grant No. 2016YFF0101803)the Hefei Municipal Natural Science Foundation (Grant No. 2021017)the Fundamental Research Funds for the Central Universities of China (Grant No. JZ2019HGTB0076)。
文摘We propose a novel system for synchronous measurement of out-of-plane deformation and two orthogonal slopes using a single camera. The linearly polarized reference beam introduced by an optical fiber interferes with the unpolarized object beam to measure the out-of-plane deformation. A modified Mach–Zehnder interferometer is used to measure the two orthogonal slopes of the out-of-plane deformation. One of the object beams of the Mach–Zehnder interferometer is an unpolarized beam, and the other object beam is split into two orthogonal linearly polarized object beams by a polarizing prism. The two beams are orthogonally polarized. Hence, they will not interfere with each other. The two polarized beams respectively interfere with the unpolarized beam to simultaneously measure the two orthogonal slopes of the out-of-plane deformation. In addition, the imaging lens and apertures are respectively placed in three optical paths to independently control the carrier frequencies and shearing amounts. The effectiveness of this method can be proved by measuring two pressure-loaded circular plates.
基金This work has been supported by Ministerio de Ciencia e Innovacion,Gobierno de Espana(Grant Nos.CGL2017-85045-P,PID2021-123189NB-I00,DI-17-09169)Government of Aragon(Grant No.Reference Group T20_23R)Jorge Sevil has a predoctoral contract(Grant No.PRE2018-084240)co-financed by the Spanish Government and the European Social Fund(ESF).
文摘The effectiveness of monitoring and early-warning systems for ground deformation phenomena,such as sinkholes,depends on their ability to accurately resolve the ongoing ground displacement and detect the subtle deformation preceding catastrophic failures.Sagging sinkholes with a slow subsidence rate and diffuse edges pose a significant challenge for subsidence monitoring due to the low deformation rates and limited lateral strain gradients.In this work,we satisfactorily illustrate the practicality of the Brillouin optical time domain analysis(BOTDA)to measure the spatial-temporal patterns of the vertical displacement in such challenging slow-moving sagging sinkholes.To assess the performance of the approach,we compare the strain recorded by the distributed optical fiber sensor with the vertical displacement measured by high-precision leveling.The results show a good spatial correlation with the ability to identify the maximum subsidence point.There is also a good temporal correlation with the detection of an acceleration phase in the subsidence associated with a flood event.
基金supported by Japan Society for the Promotion of Science (JSPS) KAKENHI (Grant Nos. JP20K04171 and JP20H02038)。
文摘The sampling Moiré(SM) method is one of the vision-based non-contact deformation measurement methods, which is a powerful tool for structural health monitoring and elucidation of damage mechanisms of materials. In this review, the basic principle of the SM method for measuring the twodimensional displacement and strain distributions is introduced. When the grid is not a standard orthogonal grating and cracks exist on the specimen surface, the measurement methods are also stated. Two of the most typical application examples are described in detail. One is the dynamic deflection measurement of a large-scale concrete bridge, and the other is the residual thermal strain measurement of small-scale flip chip packages. Several further development points of this method are pointed out. The SM method is expected to be used for deformation measurement of various structures and materials for residual stress evaluation, crack location prediction, and crack growth evaluation on broad scales.
基金This work was supported in part by the National Natural Science Foundation of China(U1808217)the National Science Fund for Distinguished Young Scholars(52125504)+1 种基金the Highlevel Personnel Innovation Support Program of Dalian(2017RJ04)the Liao Ning Revitalization Talents Program(XLYC1807086 and XLYC1801008).
文摘Three-dimensional(3D)microdisplacement monitoring plays a crucial role in the assembly of large aircraft.This paper presents a broadly applicable high-precision online 3D microdisplacement monitoring method and system based on proximity sensors as well as a corresponding in situ calibration method,which can be applied under various extreme working conditions encountered in the aircraft assembly process,such as compact and obstructed spaces.A 3D monitoring model is first established to achieve 3D microdisplacement monitoring based only on the one-dimensional distances measured by proximity sensors,which concerns the extrinsic sensor parameters,such as the probe base point(PBP)and the unit displacement vector(UDV).Then,a calibration method is employed to obtain these extrinsic parameters with high precision by combining spatial transformation principles and weighted optimization.Finally,calibration and monitoring experiments performed for a tailplane assembly process are reported.The calibration precision for the PBP is better than±10 lm in the X and Y directions and±2 lm in the Z direction,and the calibration precision for the UDV is better than 0.07°.Moreover,the accuracy of the 3D microdisplacement monitoring system can reach±15 lm.In general,this paper provides new insights into the modeling and calibration of 3D microdisplacement monitoring based on proximity sensors and a precise,efficient,and low-cost technical means for performing related measurements in compact spaces during the aircraft assembly process.
文摘Based on laser-scanned measuring technology, a met ho d of on-line dynamic non-contact measurement and feedback control of processin g dimension, i.e. the double edges laser-scanned large diameter on-line dynami c measurement and control system is presented, which can be used to measure diam eter in large-scale machine part processing. In this paper, the working princip le, overall structure and microcomputer real-time control and data processing s ystem of the system are discussed in detail, the method of double edges scanned large diameter dimension measurement and control is theoretically analyzed, its possibility has been verified by experiments of lathing large diameters machine parts by a vertical lathe. The system adopts the measuring scheme of double edge s laser-scanned combined with grating displacement measurement. The two edges c haracteristic information of the measured diameter is given by the double edges laser-scanned measuring system, the non-contact measurement of large diameter dimension is realized to combine with the grating displacement measuring systems . The main controller gives out feedback control signal by means of measured res ults, and controls advance and retreat of lathe tool by the servo-control syste m of a vertical lathe to realize on-line dynamic non-contact measurement and c ontrol in processing.
基金supported in part by the National Natural Science Foundation of China(No.62005194).
文摘In this Letter,we propose a simple structure of an orthogonal type double Michelson interferometer.The orthogonal detection method overcomes the problems of uneven ranging sensitivity and the inability of traditional interferometers to determine the displacement direction.The displacement measurement principle and signal processing method of the orthogonal double interferometer are studied.Unlike the arctangent algorithm,the displacement analysis uses the arc cosine algorithm,avoiding any pole limit in the distance analysis process.The minimum step size of the final experimental displacement system is 5 nm,which exhibits good repeatability,and the average error is less than 0.12 nm.
基金supported by the National Natural Science Foundation of China(No.U20A20216)the Technology Domain Fund of 173 Project(No.2021-JCJQ-JJ-0284)。
文摘The compact,sensitive,and multidimensional displacement measurement device plays a crucial role in semiconductor manufacture and high-resolution optical imaging.The metasurface offers a promising solution to develop high-precision displacement metrology.In this work,we proposed and experimentally demonstrated a two-dimensional displacement(XZ)measurement device by a dielectric metasurface.Both transversal and longitudinal displacements of the metasurface can be obtained by the analysis of the interference optical intensity that is generated by the deflected light beams while the metasurface is under linearly polarized incidence.We experimentally demonstrated that displacements down to 5.4 nm along the x-axis and 0.12μm along the z-axis can be resolved with a 900μm×900μm metasurface.Our work opens up new possibilities to develop a compact high-precision multidimensional displacement sensor.
基金This work was supported by the National High Tech-nology Development 863 Program(2002aa404050)of China and the Foundation for Development of science of Shanghai(0114nm013),
文摘We describe a new method for angular displacement measurements that is based on a Fabry-Perot interferometer. A measurement accuracy of 10-8 rad is obtained by use of the sinusoidal phase modulating interferometry. Another Fabry-Perot interferometer is used to obtain the key initial angle of incidence.
基金the National Natural Science Foundation of China under Grants No.10562003 and 10272054
文摘The numerical moire method with sensitivity as high as 0.03 nm has been presented. A quantitative displacement and strain analysis program has been proposed by using this method. It is applied to an edge dislocation and a stacking fault in aluminum. The measured strain of edge dislocation is compared with theoretical prediction given by Peierls-Nabarro dislocation model. The displacement of stacking fault is also obtained.
文摘In this paper, a sinusoidal phase-modulating Fabry-Perot interferometer is proposed to measure angular displacement. The usefulness of the interferometer is demonstrated by simulations and experiments.
基金supported by the National Natural Science Foundation of China (Grant No 60437010)
文摘This paper presents the anisotropic optical feedback of a single frequency intra-cavity He-Ne laser. A novel phenomenon was discovered that the laser output an elliptical polarized frequency instead of the initial linear polarized one. Two intensities with a phase difference were detected, both of which were modulated in the form of cosine wave and a fringe shift corresponds to a λ/2 movement of the feedback mirror. The phase difference can be continuously modulated by the wave plate in the external cavity. Frequency stabilization was used to stabilize the laser frequency so as to enlarge the measuring range and improve the measurement precision. This anisotropic optical feedback system offers a potential displacement measurement technology with the function of subdivision of λ/2 and in-time direction judgment. The three-mirror Fabry Perot cavity model is used to present the experimental results. Given the lack of need of lasing adjustment, this full intra-cavity laser can significantly improve the simplicity and stability of the optical feedback system.
基金supported by National Natural Science Foundation of China(Grant No.51275461)Zhejiang Provincial Natural Science Foundation of China(Grant No.Z1110189)+1 种基金National Hi-tech Research and Development Program of China(863 ProgramGrant No.2009AA045401)
文摘The current research of hydrodynamic bearing in blood pump mainly focuses on the bearing structure design.Compared with the typical plane slider bearing and Rayleigh step bearing,spiral groove bearing has excellent performance in load-carrying capacity.However,the load-carrying capacity would decrease significantly with increasing flow rate in conventional designs.In this paper,the special treatment is made to the upper spiral groove bearing to make sure that both the circulatory flowing and load-carrying capacity are high.Three-dimensional computational fluid dynamics(CFD) models in the space between rotor and shaft are developed by using FLUENT software.Effects of groove number,film height and groove depth on load-carrying capacity of the spiral groove bearings are investigated by orthogonal experiment design.The experimental results show that film height is the most remarkable factor to the load-carrying capacity.The variation tendency of load-carrying capacity reveals that the best combination of geometry is the one with groove number of 8,film height 0.03 mm and groove depth 0.08 mm.The velocity and pressure distributions in spiral groove bearings are also analyzed,and the analysis result shows that the distributions are in conformity with the design of the blood pump based on the principle of hydrodynamic bearing.The displacement of the rotor with the best combination parameters is tested by using laser displacement sensors,the testing result shows that the suspending performance is satisfactory both in axial and radial directions.This research proposes a bearing design method which has sufficient load-carrying capacity to support rotor as an effective passive hydrodynamic bearing.
基金Selected from Proceedings of the 7th International Conference on Frontiers of Design and Manufacturing (ICFDM’2006)This project is supported by Na-tional Natural Science Foundation of China (No. 50375074)Specialized Research Fund for the Doctoral Program of Higher Education (No. 20050319007).
文摘ASeblsf-tmraicxti:n gA innteewrf esreelnf-cme ioxcincgu rms iicnr oa -liansteerrf derioodmee t(eLrD b)a sbeyd r eofnl eecxtitnergn tahl ep lhiagshet fmroomdu ala tmioinrr oisr-plirkees etanrtgedet. in front of the laser. Sinusoidal phase modulation of the beam is obtained by an electro-optic crystal (EOC) in the external cavity. The phase of the interference signal is demodulated by Fourier analysis method. The combination of the modulation and demodulation decreases the sensitivity of the instru-ment to fluctuations of the laser power and the noise induced by environment. Experimentally, the new micro-interferometer is applied to measure the micro-displacement of a high precision commer-cial PZT with an accuracy of 〈10 nm.
基金The authors are grateful to the financial support by the Science and Technology Development Foundation, Education Commission of Beijing, P. R. China (No. 00KJ-094).
文摘This paper presents a new optical interferometric system, MMI-T/G, composed of a modified four-beam moire interferometer and a Twyman/Green interferometer. The MMI-T/G system can measure three-dimensional displacement fringe patterns with a single loading on the specimen, and the in-plane and out-of-plane displacement fields can be measured independently and defined clearly. The optical setup has the advantages of structural novelty, flexibility, and high fringe contrast. Moreover, the in-plane displacement sensitivity is twice of that of the normal moire interferometer. The measuring techniques to obtain the fringe patterns and displacement fields using the MMI-T/G system are described. The experimental results of thermal displacement of an electronic device are shown.
基金supported by the Science Fund of State Key Laboratory of Automotive Safety and Energy(KF16162)
文摘Being the two primary approaches for full-field kinematics measurements, both subset-based local digital image correlation (DIC) and finite element-based global DIC have been extensively studied. Nowadays, most commercial DIC systems employ local DIC algorithm because of its advantages of straight forward principle and higher efficiency. However, several researchers argue that global DIC can provide better displacement results due to the displacement continuity constraint among adjacent elements. As such, thoroughly examining the performance of these two different DIC methods seems to be highly necessary. Here, the random errors associated with local DIC and two global DIC methods are theoretically analyzed at first. Subsequently, based on the same algorithmic details and parameters during analyses of numerical and real experiments, the performance of the different DIC approaches is fairly compared. Theoretical and experimental results reveal that local DIC outperforms its global counterpart in terms of both displacement results and computational efficiency when element (subset) size is no less than 11 pixels.
基金support from the US National Institute on Deafness and Other Communication Disorders(NIDCD R01 DC016079)is gratefully acknowledgedsupport by the Center for Holographic Studies and Laser micro-mechaTronics(CHSLT)at WPI.
文摘The auditory system of mammals enables the perception of sound from our surrounding world.Containing some of the smallest bones in the body,the ear transduces complex acoustic signals with high-temporal sensitivity to complex mechanical vibrations with magnitudes as small as tens of picometers.Measurements of the shape and acoustically induced motions of different components of the ear are essential if we are to expand our understanding of hearing mechanisms,and also provide quantitative information for the development of numerical ear models that can be used to improve hearing protection,clinical diagnosis,and repair of damaged or diseased ears.We are developing digital holographic methods and instrumentation using an ultra-high speed camera to measure shape and acoustically-induced motions in the middle ear.Specifically we study the eardrum,the first structure of the middle ear which initializes the acoustic-mechanical transduction of sound for hearing.Our measurement system is capable of performing holographic measurement at rates up to 2.1 M frames per second.Two shape measurement modalities had previously been implemented into our holographic systems:(1)a multi-wavelength method with a wavelength tunable laser;and(2)a multi-angle illumination method with a single wavelength laser.In this paper,we present a third method using a miniaturized fringe projection system with a microelectromechanical system(MEMS)mirror.Further,we optimize the processing of large data sets of holographic displacement measurements using a vectorized Pearson's correlation algorithm.We validate and compare the shape and displacement measurements of our methodologies using a National Institute of Standards and Technology(NIST)traceable gauge and sound-activated latex membranes and human eardrums.
基金supported by the National Natural Science Foundation of China under Grant No.51475262
文摘A signal processing method of realizing a large-range displacement measurement in a sinusoidal phase- modulating laser diode interferometer is proposed. The method of obtaining the dynamic value of the effective sinusoidal phase-modulating depth is detailed, and the residual amplitude modulation is also taken into account. Numerical simulations and experiments are carried out to compare this method with the traditional one. We prove that, with this method, the sinusoidal phase-modulating laser diode interferometer can realize a centimeter-level displacement measurement range with high precision, which is much better than the traditional method.