Indoor air environment includes indoor thermal environment and air quality, and a reasonable ventilation provides guarantee for a good indoor environment. A numerical study of the indoor environment in different venti...Indoor air environment includes indoor thermal environment and air quality, and a reasonable ventilation provides guarantee for a good indoor environment. A numerical study of the indoor environment in different ventilation is presented in this paper. The External Energy Saving Lab of the WenYuan Building was selected for this purpose, and its indoor air quality and thermal performance in the typical summer climate were simulated. For the numerical simulation, the techniques of Fluent Air-pak was adopted to establish the physical and numerical model of lab. A attention is given to the velocity field and the distribution of pollutant concentration, followed by a discussion of two ventilation modes (displacement ventilation and up-in and up-out ventilation). By comparison, it is found that the Displacement ventilation in improving indoor air quality is obviously superior to the traditional up-in and up-out ventilation.展开更多
As infectious respiratory diseases are highly transmissible through the air,researchers have improved traditional total volume air distribution systems to reduce infection risk.Multi-vent module-based adaptive ventila...As infectious respiratory diseases are highly transmissible through the air,researchers have improved traditional total volume air distribution systems to reduce infection risk.Multi-vent module-based adaptive ventilation(MAV)is a novel ventilation type that facilitates the switching of inlets and outlets to suit different indoor scenarios without changing ductwork layout.However,little research has evaluated MAV module sizing and air velocity selection,both related to MAV system efficiency in removing contaminants and the corresponding level of protection for occupants in the ventilated room.Therefore,the module-source offset ratio(MSOR)is proposed,based on the MAV module size and its distance from an infected occupant,to inform selection of optimal MAV module parameters.Computational fluid dynamics simulations illustrated contaminant distribution in a two-person MAV equipped office.Discrete phase particles modelled respiratory contaminants from the infected occupant,and contaminant concentration distributions were compared under four MAV air distribution layouts,three air velocities,and three module sizes considered using the MsOR.Results indicate that lower air velocities favour rising contaminant levels,provided the ventilation rate is met.Optimal contaminant discharge can be achieved when the line of outlets is located directly above the infected occupant.Using this parameter to guide MAV system design,85.7% of contaminants may be rendered harmless to the human body within 120 s using the default air vent layout.A more appropriate supply air velocity and air vent layout increases this value to 91.4%.These results are expected to inform the deployment of MAV systems to reduce airborne infection risk.展开更多
Natural ventilation(NV)has been considered a simple and effective method of ventilation.However,the intro-duction of NV does not achieve better indoor air quality(IAQ)when the outdoor atmospheric environment is pollut...Natural ventilation(NV)has been considered a simple and effective method of ventilation.However,the intro-duction of NV does not achieve better indoor air quality(IAQ)when the outdoor atmospheric environment is polluted.Therefore,portable air cleaners(PACs)are increasing in use in recent years,but their effectiveness is highly dependent on the residents’habits.A typical residence in Xi’an,China was selected to examine the effects of the use of NV alone and the use of NV and PACs together on IAQ in the three occupant states,i.e.,unoc-cupied,sleeping and leisure.Parameters,such as temperature,relative humidity,CO_(2),and PM_(2.5)concentration were measured when changing the window opening and the position of the PAC.The results showed that in the unoccupied state,opening the inner door can promote a more uniform thermal and humid environment.In the sleeping state,the I/O ratio of the PM_(2.5)concentration was the lowest when the window opening of the bedroom was 1/2 or 3/4,with a mean value of 0.3.In the leisure state,only using NV,when the purification rate reaches 90%,the mean purification time of each window opening in the living room is 87.5 min.The mean purification time was reduced to 25 min when both NV and PAC were used.The on-site purification efficiencies were 91.0%and 94.5%,when the window opening was 1/2(i.e.,the PAC was placed in the center of the room)and 3/4(i.e.,the PAC was placed away from the outer window),respectively.展开更多
Mechanical Ventilation with Heat Recovery(MVHR)systems are gaining increasing interest in buildings with low energy demand,for improvement of the Indoor Air Quality(IAQ)and reduction of the ventilation energy loss.In ...Mechanical Ventilation with Heat Recovery(MVHR)systems are gaining increasing interest in buildings with low energy demand,for improvement of the Indoor Air Quality(IAQ)and reduction of the ventilation energy loss.In retrofitted buildings,MVHRs are often integrated with an additional air heater to cover space heating demand.Hence,evaluation of the interactions between MVHR and heat emitter,and their effects on indoor airflow characteristics is of significant importance.The present study aims to investigate effects of a combined MVHR-fan-coil system in heating mode on IAQ and thermal comfort parameters inside a retrofitted room,by means of a computational fluid dynamic(CFD)code.The proposed CFD model is validated by comparing the numerical results with experimental data.The results yielded by numerical simulations allow evaluating the indoor environmental quality characteristics as well as addressing the MVHR and fan coil interactions.The results indicate that the airflow discharged from the fan coil could have a significant impact on the age of the air;while it provides a desirable thermal comfort condition within the room,it may hinder to some extent delivery of the fresh air to the occupied zone due to creation of counterflow fields.Furthermore,it is shown that although increasing the fan speed(ON mode)would slightly enhance the air change efficiency,the OFF mode yields not only a better distribution of the fresh air but also a higher ventilation efficiency than when fan coil operates.展开更多
The present paper presents a numerical analysis of the difference in comfort level inside a room of a residential building when roof top turbine ventilator is installed. This analysis simulates various comfort factors...The present paper presents a numerical analysis of the difference in comfort level inside a room of a residential building when roof top turbine ventilator is installed. This analysis simulates various comfort factors which includes the indoor air movement, room temperature, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD). Various test cases of ventilator exhaust rate were examined. The results showed that general comfort satisfying international standards in building can be achieved. This study also presents a qualitative and quantitative study of indoor air temperature and overall indoor air flow pattern. A promising conclusion that can be drawn from this study is that wind driven ventilators can play an important role in the design of a cost effective and energy efficient ventilation system inside a building.展开更多
Wind catchers used in various countries in Middle East and North Africa in order to improve indoor air environ-ment and to reduce reliance on cooling load.However,nowadays they are used across the globe with modern sh...Wind catchers used in various countries in Middle East and North Africa in order to improve indoor air environ-ment and to reduce reliance on cooling load.However,nowadays they are used across the globe with modern shapes and advanced techniques.The study focuses on investigating new and innovative shapes of wind catch-ers to improve air speed indoors which will elevate indoor comfort and air quality in buildings.The study used computer modeling CFD and a real model experiment to conduct the study.The study highlighted that curved shapes have highest pattern of wind speed driven,especially curved shape with double inlets.In addition,the study showed that octagon shape has the lowest pattern of wind speed driven because of its various sides which prevent air to flow easily inside the tunnel.展开更多
The necessity and feasibility of the use of the personalized ventilation(PV)technology in a toll booth is described.First,the indoor environment of the toll booth equipped with a PV system is analyzed.Based on the a...The necessity and feasibility of the use of the personalized ventilation(PV)technology in a toll booth is described.First,the indoor environment of the toll booth equipped with a PV system is analyzed.Based on the analysis results,a set of equipment for controlling the indoor air quality(IAQ)of the toll booth is devised.Then,a full-scale model of the toll booth is set up in the laboratory.The airflow organization,the optimum operation parameters,and the restraint effects of the PV system on pollution are also experimentally studied.The experimental results on the air supply characteristics show that the PV system can effectively reduce the air age,improve the ventilation efficiency,and enhance the comfort and acceptability of human beings.In addition,this system plays a significant role in preventing pollution.展开更多
For a mechanically ventilated space,the nominal age of the air can be obtained by the reciprocal of the air change rate.However,values of the local mean age of the air in practice may differ to some extent from the no...For a mechanically ventilated space,the nominal age of the air can be obtained by the reciprocal of the air change rate.However,values of the local mean age of the air in practice may differ to some extent from the nominal one since the nominal time constant employs as reference the theoretical optimum model.This discrepancy could become more prominent in spaces conditioning with both ventilation and heating system where the indoor air pattern is affected by turbulent mixed convection flow.Given importance of knowledge on the distribution of age of the air in these spaces,the present study provides insights on how ventilation design in floor heating systems can optimise the delivery of fresh air into the breathing zone.In this context,by establishing a computational fluid dynamic(CFD)model validated against experimental data,the local mean age of the air as well as the indoor air quality(IAQ)indices in the breathing zone of the floor heating system are examined under different ventilation modes.Six different ventilation scenarios are regarded in order to find the optimal ventilation design in terms of the delivery of the fresh air and ventilation effectiveness in occupied space.Furthermore,the integrated effects of the floor temperature and inlet supply temperature along with the ventilation design on the distribution of local age of the air are addressed.The obtained results indicate that the up-supply ventilation strategy is more efficient than down-supply one in the ventilation effectiveness and delivery of fresh air into the breathing zone.Moreover,it is shown that the mean age of the air in the breathing zone of the up-supply ventilation increases with increment of the Ri(Richardson number),whereas an increase in Ri improves the delivery of fresh air in down-supply mode.For a given floor temperature,the similar trend is also observed in the variation of age of the air with the characteristic temperature of supply inlet,namely the temperature difference between inlet supply and surrounding walls.展开更多
文摘Indoor air environment includes indoor thermal environment and air quality, and a reasonable ventilation provides guarantee for a good indoor environment. A numerical study of the indoor environment in different ventilation is presented in this paper. The External Energy Saving Lab of the WenYuan Building was selected for this purpose, and its indoor air quality and thermal performance in the typical summer climate were simulated. For the numerical simulation, the techniques of Fluent Air-pak was adopted to establish the physical and numerical model of lab. A attention is given to the velocity field and the distribution of pollutant concentration, followed by a discussion of two ventilation modes (displacement ventilation and up-in and up-out ventilation). By comparison, it is found that the Displacement ventilation in improving indoor air quality is obviously superior to the traditional up-in and up-out ventilation.
基金supported by the National Natural Science Foundation of China[No.52078009]the special fund of Beijing Key Laboratory of Indoor Air Quality Evaluation and Control[No.BZ0344KF20-05]the joint research project of the Wind Engineering Research Center,Tokyo Polytechnic University(MEXT(Japan)Promotion of Distinctive Joint ResearchCenter Program)[No.JPMXP0619217840,No.JURC20202007].
文摘As infectious respiratory diseases are highly transmissible through the air,researchers have improved traditional total volume air distribution systems to reduce infection risk.Multi-vent module-based adaptive ventilation(MAV)is a novel ventilation type that facilitates the switching of inlets and outlets to suit different indoor scenarios without changing ductwork layout.However,little research has evaluated MAV module sizing and air velocity selection,both related to MAV system efficiency in removing contaminants and the corresponding level of protection for occupants in the ventilated room.Therefore,the module-source offset ratio(MSOR)is proposed,based on the MAV module size and its distance from an infected occupant,to inform selection of optimal MAV module parameters.Computational fluid dynamics simulations illustrated contaminant distribution in a two-person MAV equipped office.Discrete phase particles modelled respiratory contaminants from the infected occupant,and contaminant concentration distributions were compared under four MAV air distribution layouts,three air velocities,and three module sizes considered using the MsOR.Results indicate that lower air velocities favour rising contaminant levels,provided the ventilation rate is met.Optimal contaminant discharge can be achieved when the line of outlets is located directly above the infected occupant.Using this parameter to guide MAV system design,85.7% of contaminants may be rendered harmless to the human body within 120 s using the default air vent layout.A more appropriate supply air velocity and air vent layout increases this value to 91.4%.These results are expected to inform the deployment of MAV systems to reduce airborne infection risk.
基金This study was jointly funded by the National Key Research and Development Program of China(No.2016YFC0700500)the Opening Fund of Key Laboratory of Plateau Green Building and Ecological Community in Qinghai Province(No.KLKF-2020-005).
文摘Natural ventilation(NV)has been considered a simple and effective method of ventilation.However,the intro-duction of NV does not achieve better indoor air quality(IAQ)when the outdoor atmospheric environment is polluted.Therefore,portable air cleaners(PACs)are increasing in use in recent years,but their effectiveness is highly dependent on the residents’habits.A typical residence in Xi’an,China was selected to examine the effects of the use of NV alone and the use of NV and PACs together on IAQ in the three occupant states,i.e.,unoc-cupied,sleeping and leisure.Parameters,such as temperature,relative humidity,CO_(2),and PM_(2.5)concentration were measured when changing the window opening and the position of the PAC.The results showed that in the unoccupied state,opening the inner door can promote a more uniform thermal and humid environment.In the sleeping state,the I/O ratio of the PM_(2.5)concentration was the lowest when the window opening of the bedroom was 1/2 or 3/4,with a mean value of 0.3.In the leisure state,only using NV,when the purification rate reaches 90%,the mean purification time of each window opening in the living room is 87.5 min.The mean purification time was reduced to 25 min when both NV and PAC were used.The on-site purification efficiencies were 91.0%and 94.5%,when the window opening was 1/2(i.e.,the PAC was placed in the center of the room)and 3/4(i.e.,the PAC was placed away from the outer window),respectively.
文摘Mechanical Ventilation with Heat Recovery(MVHR)systems are gaining increasing interest in buildings with low energy demand,for improvement of the Indoor Air Quality(IAQ)and reduction of the ventilation energy loss.In retrofitted buildings,MVHRs are often integrated with an additional air heater to cover space heating demand.Hence,evaluation of the interactions between MVHR and heat emitter,and their effects on indoor airflow characteristics is of significant importance.The present study aims to investigate effects of a combined MVHR-fan-coil system in heating mode on IAQ and thermal comfort parameters inside a retrofitted room,by means of a computational fluid dynamic(CFD)code.The proposed CFD model is validated by comparing the numerical results with experimental data.The results yielded by numerical simulations allow evaluating the indoor environmental quality characteristics as well as addressing the MVHR and fan coil interactions.The results indicate that the airflow discharged from the fan coil could have a significant impact on the age of the air;while it provides a desirable thermal comfort condition within the room,it may hinder to some extent delivery of the fresh air to the occupied zone due to creation of counterflow fields.Furthermore,it is shown that although increasing the fan speed(ON mode)would slightly enhance the air change efficiency,the OFF mode yields not only a better distribution of the fresh air but also a higher ventilation efficiency than when fan coil operates.
文摘The present paper presents a numerical analysis of the difference in comfort level inside a room of a residential building when roof top turbine ventilator is installed. This analysis simulates various comfort factors which includes the indoor air movement, room temperature, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD). Various test cases of ventilator exhaust rate were examined. The results showed that general comfort satisfying international standards in building can be achieved. This study also presents a qualitative and quantitative study of indoor air temperature and overall indoor air flow pattern. A promising conclusion that can be drawn from this study is that wind driven ventilators can play an important role in the design of a cost effective and energy efficient ventilation system inside a building.
文摘Wind catchers used in various countries in Middle East and North Africa in order to improve indoor air environ-ment and to reduce reliance on cooling load.However,nowadays they are used across the globe with modern shapes and advanced techniques.The study focuses on investigating new and innovative shapes of wind catch-ers to improve air speed indoors which will elevate indoor comfort and air quality in buildings.The study used computer modeling CFD and a real model experiment to conduct the study.The study highlighted that curved shapes have highest pattern of wind speed driven,especially curved shape with double inlets.In addition,the study showed that octagon shape has the lowest pattern of wind speed driven because of its various sides which prevent air to flow easily inside the tunnel.
文摘The necessity and feasibility of the use of the personalized ventilation(PV)technology in a toll booth is described.First,the indoor environment of the toll booth equipped with a PV system is analyzed.Based on the analysis results,a set of equipment for controlling the indoor air quality(IAQ)of the toll booth is devised.Then,a full-scale model of the toll booth is set up in the laboratory.The airflow organization,the optimum operation parameters,and the restraint effects of the PV system on pollution are also experimentally studied.The experimental results on the air supply characteristics show that the PV system can effectively reduce the air age,improve the ventilation efficiency,and enhance the comfort and acceptability of human beings.In addition,this system plays a significant role in preventing pollution.
文摘For a mechanically ventilated space,the nominal age of the air can be obtained by the reciprocal of the air change rate.However,values of the local mean age of the air in practice may differ to some extent from the nominal one since the nominal time constant employs as reference the theoretical optimum model.This discrepancy could become more prominent in spaces conditioning with both ventilation and heating system where the indoor air pattern is affected by turbulent mixed convection flow.Given importance of knowledge on the distribution of age of the air in these spaces,the present study provides insights on how ventilation design in floor heating systems can optimise the delivery of fresh air into the breathing zone.In this context,by establishing a computational fluid dynamic(CFD)model validated against experimental data,the local mean age of the air as well as the indoor air quality(IAQ)indices in the breathing zone of the floor heating system are examined under different ventilation modes.Six different ventilation scenarios are regarded in order to find the optimal ventilation design in terms of the delivery of the fresh air and ventilation effectiveness in occupied space.Furthermore,the integrated effects of the floor temperature and inlet supply temperature along with the ventilation design on the distribution of local age of the air are addressed.The obtained results indicate that the up-supply ventilation strategy is more efficient than down-supply one in the ventilation effectiveness and delivery of fresh air into the breathing zone.Moreover,it is shown that the mean age of the air in the breathing zone of the up-supply ventilation increases with increment of the Ri(Richardson number),whereas an increase in Ri improves the delivery of fresh air in down-supply mode.For a given floor temperature,the similar trend is also observed in the variation of age of the air with the characteristic temperature of supply inlet,namely the temperature difference between inlet supply and surrounding walls.