Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20...Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application.展开更多
To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture usin...To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture using buttress plate associated with antografting of fibula and iliac bone were analyzed retrospectively.Results All cases were followed up for an average of 24 months(8~55 months).The average time of octets bridge forming were 4 months(3~5 months) while the average time for bone union were 8 months (6~14 months).According to Shelbourne rating system,result of all 18 cases were excellent and no malunion,infection were found.Conclusion Buttress plate associated with antografting of fibula and iliac bone is an effective alternative for the treatment of distal femoral C3 type fracture.It can provide more stable fixation to the bone and earlier functional exercises can be achieved.5 refs,3 figs,1 tab.展开更多
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ...Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.展开更多
To discuss and evaluate the method and effect of using calcaneal anatomic plate in treatment of intra-articular fractures of the calcaneus with assistant of arthroscope, 86 intra-articular fractures of the calcaneus i...To discuss and evaluate the method and effect of using calcaneal anatomic plate in treatment of intra-articular fractures of the calcaneus with assistant of arthroscope, 86 intra-articular fractures of the calcaneus in 78 patients were reduced by open reduction, and rigid fixation was made with calcaneal anatomic plate under assistant of arthroscope. The average follow-up duration was 18 months (range 12-30 months). The effect of treatment was evaluated according to AOFAS and X-ray before and after operation. The results showed that 86 patients have obtained satisfactory reduction according to X-ray, and there was significant difference before and after operation (P〈0. 01), the total excellent and fine rate was 91.86%. Treating intra-articular fractures of the calcaneus with calcaneal anatomic plate under arthroscope may provide more chance to achieve anatomical reconstruction, which can lead to satisfied recovery of function and few complication.展开更多
Purpose:To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods:The study group is treated...Purpose:To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods:The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results:The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion:The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal.展开更多
Objective:To investigate the effect of locking compression plate internal fixation on the injury extent and bone metabolism of Robinson 2A and 2B middle clavicular fractures.Methods:Totally 80 cases of patients with R...Objective:To investigate the effect of locking compression plate internal fixation on the injury extent and bone metabolism of Robinson 2A and 2B middle clavicular fractures.Methods:Totally 80 cases of patients with Robinson 2A and 2B middle clavicular fractures admitted to our hospital between March 2017 and January 2019 were divided into the control group(n=41)receiving conventional kirschner wire internal fixation and the observation group(n=39)receiving locking compression plate internal fixation according to the operation plans.The differences in serum contents of inflammatory factors,oxidative stress indexes and bone metabolism indexes were compared between the two groups of patients before patients entered operating room,24 h after surgery and 48 h after surgery.Results:Before patients entered operating room,there were no statistically significant differences in the serum contents of inflammatory factors,oxidative stress indexes or bone metabolism indexes between the two groups(P>0.05).At 24 h and 48 h after surgery,serum inflammatory factors interleukin-1(IL-1),interleukin-17(IL-17),high-sensitivity C-reactive protein(hs-CRP)and tumor necrosis factorα(TNF-α)contents in the observation group were lower than those in the control group;serum reactive oxygen species(ROS)and lipid hydroperoxide(LHP)contents were lower than those in the control group,while catalase(CAT)and glutathione peroxidase(GSH-Px)contents were higher than those in the control group;serum N-terminal propeptide of procollagen type I(PINP),bone gla protein(BGP)and alkaline phosphatase(ALP)contents were higher than those in the control group,while N-telopeptide of typeⅠcollagen(NTX),C-telopeptide of typeⅠcollagen(CTX)and tartrate-resistant acid phosphatase 5b(TRACP5b)contents were lower than those in the control group(P<0.05).Conclusion:Locking compression plate internal fixation can reduce the postoperative trauma extent and help promote the fracture healing in patients with Robinson 2A and 2B middle clavicular fracture.展开更多
Purpose To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods The study group is treated...Purpose To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal.展开更多
Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic...Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76°and 64°, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs.展开更多
Objectives: This study compared the clinical and radiological outcomes of two different methods for the treatment of distal radial intra-articular fractures. Patients and Methods: Forty-six patients with distal radius...Objectives: This study compared the clinical and radiological outcomes of two different methods for the treatment of distal radial intra-articular fractures. Patients and Methods: Forty-six patients with distal radius intra-arti-cular fractures were divided into two groups. Group I included 24 patients with type C fracture treated by external fixator augmented by percutaneous K-wires. Group II included 22 patients with type C fracture treated by volar locked distal radial plate augmented by K-wires. Two patients had complex injuries necessitating double plating (sandwich). All patients were evaluated clinically by Mayo Wrist Score and radiologically by Sarmiento’s radiological score. Results: Both groups reported good personal satisfaction according to Mayo Wrist Score, and the results were not statistically different between the two groups. In Group I, 19 patients (79.2%) had excellent radiological outcome and five patients (20.9%) had good radiological outcome according to Sarmiento’s radiological score. In Group II, 20 patients (90.9%) had excellent outcome, and two (9.1%) had good radiological outcome;there was no or insignificant deformity. Conclusions: Complex distal radial fractures can be treated either by external fixation (ligamentotaxis) or by locked pre-contoured plating. The clinical outcome of plating and external fixator in our study did not show any statistically significant difference. The radiological outcome had no correlation with the clinical outcome.展开更多
Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,...Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,VIP and Wanfang,were searched for the original study.Literature was screened according to the inclusion and exclusion criteria,and the methodological quality of the included studies was evaluated by Cochrane risk bias assessment tool.The software Revman 5.4 was used for data analysis.Results:A total of 19 studies were included in the study.The clinical effective rate of the plate group[RR=0.96,95%CI(0.93,0.99),P=0.007],Radial inclination[MD=-1.85,95%CI(-2.93,-0.77),P=0.0008],Ulnar inclination[MD=-2.49,95%CI(-3.95,-1.04),P=0.0007],relative height of radius[MD=-1.63,95%CI(-2.40,-0.86),P<0.0001]were better than those in small splints group.There was no significant difference in fracture healing time[MD=-4.39,95%CI(-9.07,0.28),P=0.07]and complications[RR=1.57,95%CI(0.98,2.52),P=0.06]between the two groups.In terms of treatment cost[MD=-2.83,95%CI(-3.37,-2.30),P<0.00001],the small splint group was better than the plate treatment group.Conclusion:Compared with small splints therapy,plate internal fixation has advantages in clinical effective rate and imaging scores.There is no significant difference in fracture healing time and complications between the two groups.In terms of treatment cost,small splint therapy is better than plate therapy.Clinical treatment should be selected and formulated according to the individual situation,demands and clinical practice of patients.展开更多
Purpose: The proximal femoral nail anti-rotation (PFNA) is known to have advantages in enhancing the anchorage ability of internal fixation in elderly unstable osteoporotic intertrochanteric fracture patients. However...Purpose: The proximal femoral nail anti-rotation (PFNA) is known to have advantages in enhancing the anchorage ability of internal fixation in elderly unstable osteoporotic intertrochanteric fracture patients. However whether it is superior to condylar blade fixation is not clear. This study aimed to determine which treatment has better clinical outcomes in older patients. Materials and Methods: A total of 86 patients over the age of 60 with unstable trochanteric fractures within the past 3 weeks, were included in this prospective study conducted from June 1, 2018, to May 31, 2021. All the intertrochanteric fractures were classified according to AO/OTA classification. Among them, 44 cases were treated with the Proximal Femoral Nail (PFNA2) with or without an augmentation screw, and 42 cases were treated with the Condylar Blade Plate. In addition, the operative time, intraoperative blood loss, intraoperative and postoperative blood transfusion, postoperative weight-bearing time, hospitalization time, Harris score of hip function, Kyle’s criteria and postoperative complications were compared between the two groups. Results: The mean duration of surgery for the PFN group was 66.8 minutes (on average), whereas for the condylar blade plate group, it was 99.30 minutes (on average). The PFNA2 group experienced less blood loss (average of 80 mL) compared to the condylar blade plate group (average of 120 mL). Union and partial weight-bearing occurred earlier in the PFNA2 group (14.1 weeks and 10.6 weeks, respectively) compared to the Condylar blade plate group (18.7 weeks and 15.8 weeks). In two patients from the PFNA2 group, screw backing out and varus collapse complications were encountered;however, these patients remained asymptomatic and did not require revision surgery. In two other patients, screw cut out and breakage of the nail at the helical screw hole leading to non-union of the proximal femur were observed during the nine-month follow-up, necessitating revision surgery with prosthetic replacement. Among the condylar blade plate group, three patients experienced complications, including blade breakage at the blade and plate junction. In two cases, the fracture united in varus, and in one case, the blade cut through, resulting in non-union of the femoral head, which required revision surgery. According to the Harris hip score and Kyle’s criteria, a good-excellent outcome was observed in 92.85% of cases in the PFNA2 group and 90.90% of cases in the condylar blade plate group. Conclusion: Both the Proximal Femoral Nail A2 and Condylar blade plate are effective implants for the treatment of unstable trochanteric fractures. The intramedullary implant promotes biological healing and allows for early ambulation with minimal complications. Similarly satisfactory restoration of anatomy and favorable radiological and functional results can be achieved with the biological fixation provided by the 95-degree condylar blade plate. However, the use of PFNA2 internal fixation technique has the advantage of less trauma in elderly patients than the 95-degree condylar blade plate.展开更多
Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly...Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group(60 cases)and observation group(60 cases).The control group was treated with plate screw internal fixation,The observation group used locking compression plate internal fixation,Compare the effect of treatment,the success rate of operation and the time of postoperative recovery.results:compared the effective rate of the two groups,the observation group(93.33%)was significantly higher than the control group(75.00%).Compared with the two groups,the success rate of operation and the time of postoperative recovery,the observed composition power was higher than that of the control group,and the postoperative recovery time was lower than that of the control group,P<0.05.Conclusion:The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation,shorten the recovery time after operation,the overall curative effect is ideal,and the clinical popularization value is high.展开更多
Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphaticall...Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphatically observing fracture healing and shoulder joint function.Methods:Totally 44 elderly patients with Robinson type 2B displaced midshaft clavicle fractures were included from the Department of Orthopaedics,Shenyang Fourth People's Hospital during February 2016 and December 2018,including 23 males and 21 females,mean age(69.8±10.2)years old.The patients were divided into a bridge combined internal fixation system group(bridge group,n=22)and a locking compression plate internal fixation group(plate group,n=22)according to the internal fixation methods.The operation time,intraoperative blood loss,fracture healing time,and postoperative complications were recorded.At 12 months after surgery,the shoulder joint Constant-Murley score and DASH score were used to assess the recovery of joint function.The serum levels of bone turnover biochemical markers procollagen I N-terminal peptide(P1NP),cross-linked Carboxy-terminal telopeptide of typeⅠcollagen(CTX-I),and osteoblast specific factor(OSF)were measured before and 3 months after surgery.Results:The operation time,intraoperative blood loss and fracture healing time of the bridge group were significantly shorter than those of the plate group(P<0.05).Constant scores and DASH scores in the bridge group were significantly better than those of the plate group at 12 months after surgery(P<0.05).Serum levels of CTX-I was significantly decreased,while the P1NP and OSF were significantly increased compared with before surgery in the both groups(P<0.05),and the changes were more obvious in the bridge group(P<0.05).The incidence of complications was similar between the two groups(P<0.05).Conclusion:Compared with the locking plate system,the bridge combined internal fixation system can effectively improve the operation efficiency,have more benefits on fracture healing,better promote the recovery of patients'function,and reduce the failure rate of internal fixation,thus providing a better choice to treat displaced midshaft clavicle fractures by intraoperative internal fixation.展开更多
Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in ou...Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in our hospital from November 2019 to November 2020 were selected.In order to study the effective treatment method,the random-number table method was used in this study to divide the patients into two groups,namely the experimental group and the control group,and the locking compression plate treatment method and the pure plate and screw internal fixation treatment method were administered respectively to study their clinical application effects.Results:Compared with the control group,patients in the experimental group had a lower incidence of complications,shorter hospitalizations and shorter recovery time.Meanwhile,the experimental group had a better quality of recovery,and all data were significantly different from those of the control group,P<0.05,the intervention effect of the experimental group was better.Conclusion:The application of the locking compression plate in the treatment of patients with limb fractures is more conducive to promoting the postoperative healing of the patients'fractures,reducing the incidence of postoperative complications,and promoting the rapid recovery of patients,which has positive significance for clinical development.展开更多
Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the pr...Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the present work, we used the finite element analysis method to compare the biomechanical performance of a model of a construct comprising a simulated distal radius fracture considered fixated using a notional intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis system (“fixator”) versus using a commercially-available volar locking plate (VP). The biomechanical parameters determined were longitudinal stiffness and factor of safety under each of the applied loads.?For the fixator model, 1) each of the biomechanical parameters was markedly influenced by fracture gap fill ratio (FGFR) (defined as the proportion of the volume of the fracture gap that is considered occupied by the expanded polymer-filled balloon)?but not by modulus of elasticity assigned to the polymer;2) with FGFR = 100%, stiffness was comparable to that of the Ti-6Al-4V alloy VP construct model;and 3) stiffness was within the range of literature values for stiffness of constructs comprising simulated fractures in fresh cadaveric distal radii fixated using metal volar locking plate. These results suggest that the fixator may be an alternative modality to metal volar plating and, as such, deserves further evaluation.展开更多
The quadrilateral plate(QP)is an essential structure of the inner wall of the acetabulum,an important weight-bearing joint of the human body,which is often involved in acetabular fractures.The operative exposure,reduc...The quadrilateral plate(QP)is an essential structure of the inner wall of the acetabulum,an important weight-bearing joint of the human body,which is often involved in acetabular fractures.The operative exposure,reduction and fixation of QP fractures have always been the difficulties in orthopedics due to the special morphological structure and anatomical features of the QP.Fortunately,there have been many effective methods and instruments developed for QP exposure,reduction and fixation by virtue of the combined efforts of numerous orthopedists.At the same time,each method presents with its own advantages and disadvantages,resulting in different prognoses.It is necessary to have a thorough understanding of the anatomy,radiology and fixation techniques of the QP in terms of patient prognosis optimization.In this paper,the anatomical features,definition and classification of QP,operative approach selection,implant internal fixation methods and efficacy were reviewed.展开更多
Objective: To investigate the efficacy of the locking internal fixator (LIF), which includes the locking compression plate (LCP) and the less invasive stable system (LISS), in the proximal and distal tibial fra...Objective: To investigate the efficacy of the locking internal fixator (LIF), which includes the locking compression plate (LCP) and the less invasive stable system (LISS), in the proximal and distal tibial fractures. Methods: We did a retrospective study on a total of 98 patients with either proximal or distal tibial fractures from January 2003 to January 2007, who had received the opera- tion with LIF by the minimally invasive plate osteosynthe- sis (MIPO) technique. The data consisted of 43 proximal tibial fractures (type AO41 C3) and 55 distal tibial fractures (type AO43C3). Results: No complications were observed in all patients after operation. The mean healing time was 8.4 months (range 5-14 months). Only two cases of delayed union oc- curred at postoperative 10 months. No infections were re- ported after the definitive surgery even in the cases of open fractures. All patients reached a full range of motion at post- operative 6 to 9 months and regained the normal functions of knee and ankle joints. Conclusion: Using LIF in MIPO technique is a reliable approach towards the proximal and distal tibial fractures that are not suitable for intramedullary nailing.展开更多
Purpose: Distal radial fracture is one of the most common fractures. Up to now, locking plates (LP) and external fixation (EF) are two conventional surgical approaches to type C radius fracture. Which method is s...Purpose: Distal radial fracture is one of the most common fractures. Up to now, locking plates (LP) and external fixation (EF) are two conventional surgical approaches to type C radius fracture. Which method is superior has not yet reached a consensus. We try to assess the clinical effectiveness of the two in- terventions by this meta-analysis. Methods: We used network to search the PubMed, Embase, and Cochrane Medical Library of randomized controlled clinical trials about the type C distal radius fractures performed according to the search strategy mentioned in Cochrane Handbook 5.1.0 from Jan. 2005 to Jan. 2016. Patients in the experimental group were used LP, in the control group were included EF and other surgical approaches. Publication language was restricted to English. Studies that patient population and surgical indication did not define had been excluded. Studies must report at least one of the outcomes as follow: radial inclination, patmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The trials in which participants included children were excluded. We used Jadad study scores to appraise the study. Results: Seven studies included 162 patients (LP group) and 190 patients (EF group). We compared the radial inclination, palmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The radial inclination were revealed a difference favoring LP over EF [WMD = 1.84, 95% CI (0.17, 3.50), p = 0.03] and the palmar tilt and ulnar variance was no significant difference between the two groups [(WMD = 3.61, 95% CI (0.00, 7.23), p = 0.05; WMD = 0.05, 95% CI (-0.99,1.09), p = 0.93]. The functional activities of range of flexion and extension and range of supination and pronation between the two groups was no difference [WMD = 10.04, 95% CI (-6.88, 26.96), p = 0.24; WMD = 12.53, 95% CI (-9.99, 35.06), p = 0.28]. Conclusion: Locking plate and external fixation is feasible to heal radius type C fracture. We found the small difference between the two groups on imaging examination. The locking plate has the advantage on maintaining reduction, however no significant difference regarding outcomes has been found be- tween the two groups.展开更多
Objective To discuss the clinical effect of treatment with anterior decompression, bone graft and cervical locking plate fixation for cervical degeneration disease.Method 23 patients with cervical spondylotic myelopat...Objective To discuss the clinical effect of treatment with anterior decompression, bone graft and cervical locking plate fixation for cervical degeneration disease.Method 23 patients with cervical spondylotic myelopathy and cervical ossification of the posterior longitudinal ligament have undergone the treatment of anterior cervical spine locking plate fusion.Neurological signs and symptoms were evaluated before and after surgery, and mean follow up time was 11.3 months.Result In all cases,radiography demonstrated a solid bony fusion.Additional general complications include a large wound hematoma in one and hoarseness in one.All patients’ neurological function were improved.Conclusion The clinical effect of treatment with anterior decompression, bone graft and cervical locking plate fixation for cervical degeneration disease is satisfactory.展开更多
Purpose:Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment.This study compared the functional outcomes between variable angle volar plating and exte...Purpose:Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment.This study compared the functional outcomes between variable angle volar plating and external fixator with K-wire augmentation in open reduction and internal fixation.Methods:A total of 62 adult patients with comminuted intraarticular distal radius fracture were randomized into 2 groups:volar plate group and external fixator group.These patients aged between 18 and 60 years had unilateral fractures,and agreed to be included in the study.Patients with a history of fracture,bilateral fracture,associated other injuries,delayed injury for more than 2 weeks,open fracture,pre-existing arthrosis or disability,psychiatric illness and pathological fracture were excluded.Patients were followed up at 6 weeks,3 months,6 months and 1 year.The assessment of pain,functional activity,range of motion and grip strength was done at each stage of follow-up.The pain and functional activities were assessed by patient rated wrist evaluation(PRWE)score and disabilities of the arm,shoulder and hand(DASH)score.Results:Patients in volar plate group had superior PRWE score and DASH score at each stage of followup.At 1 year follow-up,the mean PRWE score were 7.48 for volar plate group and 7.35 for external fixator group;while the mean DASH score was 4.65 for volar plate group and 5.61 for external fixator group.They had better flexion and extension range of movement.They also had better pronation and supination range of motion at initial follow-up,however the difference get attenuated by 1 year.Volar plate group had significantly better grip strength than external fixator group.Complication rates were higher in external fixation group.Conclusion:Fixation with variable angle volar plate results in early wrist mobilization,better range of movement,less pain and disability and early return of function.展开更多
文摘Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application.
文摘To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture using buttress plate associated with antografting of fibula and iliac bone were analyzed retrospectively.Results All cases were followed up for an average of 24 months(8~55 months).The average time of octets bridge forming were 4 months(3~5 months) while the average time for bone union were 8 months (6~14 months).According to Shelbourne rating system,result of all 18 cases were excellent and no malunion,infection were found.Conclusion Buttress plate associated with antografting of fibula and iliac bone is an effective alternative for the treatment of distal femoral C3 type fracture.It can provide more stable fixation to the bone and earlier functional exercises can be achieved.5 refs,3 figs,1 tab.
基金2022 Key Specialty Construction Project of Traditional Chinese Medicine:Traditional Chinese Orthopedics and Traumatology Department (No.962042)2020 Regional Traditional Chinese Medicine (Orthopedics and Traumatology)Diagnosis and Treatment Center (Jin Wei Zhong[2020]No.5)。
文摘Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.
文摘To discuss and evaluate the method and effect of using calcaneal anatomic plate in treatment of intra-articular fractures of the calcaneus with assistant of arthroscope, 86 intra-articular fractures of the calcaneus in 78 patients were reduced by open reduction, and rigid fixation was made with calcaneal anatomic plate under assistant of arthroscope. The average follow-up duration was 18 months (range 12-30 months). The effect of treatment was evaluated according to AOFAS and X-ray before and after operation. The results showed that 86 patients have obtained satisfactory reduction according to X-ray, and there was significant difference before and after operation (P〈0. 01), the total excellent and fine rate was 91.86%. Treating intra-articular fractures of the calcaneus with calcaneal anatomic plate under arthroscope may provide more chance to achieve anatomical reconstruction, which can lead to satisfied recovery of function and few complication.
文摘Purpose:To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods:The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results:The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion:The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal.
基金Application and clinical characteristics of Ilizarov technique in the treatment of bone defect,No:20150802.
文摘Objective:To investigate the effect of locking compression plate internal fixation on the injury extent and bone metabolism of Robinson 2A and 2B middle clavicular fractures.Methods:Totally 80 cases of patients with Robinson 2A and 2B middle clavicular fractures admitted to our hospital between March 2017 and January 2019 were divided into the control group(n=41)receiving conventional kirschner wire internal fixation and the observation group(n=39)receiving locking compression plate internal fixation according to the operation plans.The differences in serum contents of inflammatory factors,oxidative stress indexes and bone metabolism indexes were compared between the two groups of patients before patients entered operating room,24 h after surgery and 48 h after surgery.Results:Before patients entered operating room,there were no statistically significant differences in the serum contents of inflammatory factors,oxidative stress indexes or bone metabolism indexes between the two groups(P>0.05).At 24 h and 48 h after surgery,serum inflammatory factors interleukin-1(IL-1),interleukin-17(IL-17),high-sensitivity C-reactive protein(hs-CRP)and tumor necrosis factorα(TNF-α)contents in the observation group were lower than those in the control group;serum reactive oxygen species(ROS)and lipid hydroperoxide(LHP)contents were lower than those in the control group,while catalase(CAT)and glutathione peroxidase(GSH-Px)contents were higher than those in the control group;serum N-terminal propeptide of procollagen type I(PINP),bone gla protein(BGP)and alkaline phosphatase(ALP)contents were higher than those in the control group,while N-telopeptide of typeⅠcollagen(NTX),C-telopeptide of typeⅠcollagen(CTX)and tartrate-resistant acid phosphatase 5b(TRACP5b)contents were lower than those in the control group(P<0.05).Conclusion:Locking compression plate internal fixation can reduce the postoperative trauma extent and help promote the fracture healing in patients with Robinson 2A and 2B middle clavicular fracture.
文摘Purpose To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal.
文摘Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76°and 64°, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs.
文摘Objectives: This study compared the clinical and radiological outcomes of two different methods for the treatment of distal radial intra-articular fractures. Patients and Methods: Forty-six patients with distal radius intra-arti-cular fractures were divided into two groups. Group I included 24 patients with type C fracture treated by external fixator augmented by percutaneous K-wires. Group II included 22 patients with type C fracture treated by volar locked distal radial plate augmented by K-wires. Two patients had complex injuries necessitating double plating (sandwich). All patients were evaluated clinically by Mayo Wrist Score and radiologically by Sarmiento’s radiological score. Results: Both groups reported good personal satisfaction according to Mayo Wrist Score, and the results were not statistically different between the two groups. In Group I, 19 patients (79.2%) had excellent radiological outcome and five patients (20.9%) had good radiological outcome according to Sarmiento’s radiological score. In Group II, 20 patients (90.9%) had excellent outcome, and two (9.1%) had good radiological outcome;there was no or insignificant deformity. Conclusions: Complex distal radial fractures can be treated either by external fixation (ligamentotaxis) or by locked pre-contoured plating. The clinical outcome of plating and external fixator in our study did not show any statistically significant difference. The radiological outcome had no correlation with the clinical outcome.
基金Special Project for Seedling Cultivation funded by Special Fund of Chinese Central Government for Basic Scientific Research Operations in Commonweal Research Institutes(No.ZZ11-084)。
文摘Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,VIP and Wanfang,were searched for the original study.Literature was screened according to the inclusion and exclusion criteria,and the methodological quality of the included studies was evaluated by Cochrane risk bias assessment tool.The software Revman 5.4 was used for data analysis.Results:A total of 19 studies were included in the study.The clinical effective rate of the plate group[RR=0.96,95%CI(0.93,0.99),P=0.007],Radial inclination[MD=-1.85,95%CI(-2.93,-0.77),P=0.0008],Ulnar inclination[MD=-2.49,95%CI(-3.95,-1.04),P=0.0007],relative height of radius[MD=-1.63,95%CI(-2.40,-0.86),P<0.0001]were better than those in small splints group.There was no significant difference in fracture healing time[MD=-4.39,95%CI(-9.07,0.28),P=0.07]and complications[RR=1.57,95%CI(0.98,2.52),P=0.06]between the two groups.In terms of treatment cost[MD=-2.83,95%CI(-3.37,-2.30),P<0.00001],the small splint group was better than the plate treatment group.Conclusion:Compared with small splints therapy,plate internal fixation has advantages in clinical effective rate and imaging scores.There is no significant difference in fracture healing time and complications between the two groups.In terms of treatment cost,small splint therapy is better than plate therapy.Clinical treatment should be selected and formulated according to the individual situation,demands and clinical practice of patients.
文摘Purpose: The proximal femoral nail anti-rotation (PFNA) is known to have advantages in enhancing the anchorage ability of internal fixation in elderly unstable osteoporotic intertrochanteric fracture patients. However whether it is superior to condylar blade fixation is not clear. This study aimed to determine which treatment has better clinical outcomes in older patients. Materials and Methods: A total of 86 patients over the age of 60 with unstable trochanteric fractures within the past 3 weeks, were included in this prospective study conducted from June 1, 2018, to May 31, 2021. All the intertrochanteric fractures were classified according to AO/OTA classification. Among them, 44 cases were treated with the Proximal Femoral Nail (PFNA2) with or without an augmentation screw, and 42 cases were treated with the Condylar Blade Plate. In addition, the operative time, intraoperative blood loss, intraoperative and postoperative blood transfusion, postoperative weight-bearing time, hospitalization time, Harris score of hip function, Kyle’s criteria and postoperative complications were compared between the two groups. Results: The mean duration of surgery for the PFN group was 66.8 minutes (on average), whereas for the condylar blade plate group, it was 99.30 minutes (on average). The PFNA2 group experienced less blood loss (average of 80 mL) compared to the condylar blade plate group (average of 120 mL). Union and partial weight-bearing occurred earlier in the PFNA2 group (14.1 weeks and 10.6 weeks, respectively) compared to the Condylar blade plate group (18.7 weeks and 15.8 weeks). In two patients from the PFNA2 group, screw backing out and varus collapse complications were encountered;however, these patients remained asymptomatic and did not require revision surgery. In two other patients, screw cut out and breakage of the nail at the helical screw hole leading to non-union of the proximal femur were observed during the nine-month follow-up, necessitating revision surgery with prosthetic replacement. Among the condylar blade plate group, three patients experienced complications, including blade breakage at the blade and plate junction. In two cases, the fracture united in varus, and in one case, the blade cut through, resulting in non-union of the femoral head, which required revision surgery. According to the Harris hip score and Kyle’s criteria, a good-excellent outcome was observed in 92.85% of cases in the PFNA2 group and 90.90% of cases in the condylar blade plate group. Conclusion: Both the Proximal Femoral Nail A2 and Condylar blade plate are effective implants for the treatment of unstable trochanteric fractures. The intramedullary implant promotes biological healing and allows for early ambulation with minimal complications. Similarly satisfactory restoration of anatomy and favorable radiological and functional results can be achieved with the biological fixation provided by the 95-degree condylar blade plate. However, the use of PFNA2 internal fixation technique has the advantage of less trauma in elderly patients than the 95-degree condylar blade plate.
文摘Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group(60 cases)and observation group(60 cases).The control group was treated with plate screw internal fixation,The observation group used locking compression plate internal fixation,Compare the effect of treatment,the success rate of operation and the time of postoperative recovery.results:compared the effective rate of the two groups,the observation group(93.33%)was significantly higher than the control group(75.00%).Compared with the two groups,the success rate of operation and the time of postoperative recovery,the observed composition power was higher than that of the control group,and the postoperative recovery time was lower than that of the control group,P<0.05.Conclusion:The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation,shorten the recovery time after operation,the overall curative effect is ideal,and the clinical popularization value is high.
文摘Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphatically observing fracture healing and shoulder joint function.Methods:Totally 44 elderly patients with Robinson type 2B displaced midshaft clavicle fractures were included from the Department of Orthopaedics,Shenyang Fourth People's Hospital during February 2016 and December 2018,including 23 males and 21 females,mean age(69.8±10.2)years old.The patients were divided into a bridge combined internal fixation system group(bridge group,n=22)and a locking compression plate internal fixation group(plate group,n=22)according to the internal fixation methods.The operation time,intraoperative blood loss,fracture healing time,and postoperative complications were recorded.At 12 months after surgery,the shoulder joint Constant-Murley score and DASH score were used to assess the recovery of joint function.The serum levels of bone turnover biochemical markers procollagen I N-terminal peptide(P1NP),cross-linked Carboxy-terminal telopeptide of typeⅠcollagen(CTX-I),and osteoblast specific factor(OSF)were measured before and 3 months after surgery.Results:The operation time,intraoperative blood loss and fracture healing time of the bridge group were significantly shorter than those of the plate group(P<0.05).Constant scores and DASH scores in the bridge group were significantly better than those of the plate group at 12 months after surgery(P<0.05).Serum levels of CTX-I was significantly decreased,while the P1NP and OSF were significantly increased compared with before surgery in the both groups(P<0.05),and the changes were more obvious in the bridge group(P<0.05).The incidence of complications was similar between the two groups(P<0.05).Conclusion:Compared with the locking plate system,the bridge combined internal fixation system can effectively improve the operation efficiency,have more benefits on fracture healing,better promote the recovery of patients'function,and reduce the failure rate of internal fixation,thus providing a better choice to treat displaced midshaft clavicle fractures by intraoperative internal fixation.
文摘Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in our hospital from November 2019 to November 2020 were selected.In order to study the effective treatment method,the random-number table method was used in this study to divide the patients into two groups,namely the experimental group and the control group,and the locking compression plate treatment method and the pure plate and screw internal fixation treatment method were administered respectively to study their clinical application effects.Results:Compared with the control group,patients in the experimental group had a lower incidence of complications,shorter hospitalizations and shorter recovery time.Meanwhile,the experimental group had a better quality of recovery,and all data were significantly different from those of the control group,P<0.05,the intervention effect of the experimental group was better.Conclusion:The application of the locking compression plate in the treatment of patients with limb fractures is more conducive to promoting the postoperative healing of the patients'fractures,reducing the incidence of postoperative complications,and promoting the rapid recovery of patients,which has positive significance for clinical development.
文摘Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the present work, we used the finite element analysis method to compare the biomechanical performance of a model of a construct comprising a simulated distal radius fracture considered fixated using a notional intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis system (“fixator”) versus using a commercially-available volar locking plate (VP). The biomechanical parameters determined were longitudinal stiffness and factor of safety under each of the applied loads.?For the fixator model, 1) each of the biomechanical parameters was markedly influenced by fracture gap fill ratio (FGFR) (defined as the proportion of the volume of the fracture gap that is considered occupied by the expanded polymer-filled balloon)?but not by modulus of elasticity assigned to the polymer;2) with FGFR = 100%, stiffness was comparable to that of the Ti-6Al-4V alloy VP construct model;and 3) stiffness was within the range of literature values for stiffness of constructs comprising simulated fractures in fresh cadaveric distal radii fixated using metal volar locking plate. These results suggest that the fixator may be an alternative modality to metal volar plating and, as such, deserves further evaluation.
文摘The quadrilateral plate(QP)is an essential structure of the inner wall of the acetabulum,an important weight-bearing joint of the human body,which is often involved in acetabular fractures.The operative exposure,reduction and fixation of QP fractures have always been the difficulties in orthopedics due to the special morphological structure and anatomical features of the QP.Fortunately,there have been many effective methods and instruments developed for QP exposure,reduction and fixation by virtue of the combined efforts of numerous orthopedists.At the same time,each method presents with its own advantages and disadvantages,resulting in different prognoses.It is necessary to have a thorough understanding of the anatomy,radiology and fixation techniques of the QP in terms of patient prognosis optimization.In this paper,the anatomical features,definition and classification of QP,operative approach selection,implant internal fixation methods and efficacy were reviewed.
文摘Objective: To investigate the efficacy of the locking internal fixator (LIF), which includes the locking compression plate (LCP) and the less invasive stable system (LISS), in the proximal and distal tibial fractures. Methods: We did a retrospective study on a total of 98 patients with either proximal or distal tibial fractures from January 2003 to January 2007, who had received the opera- tion with LIF by the minimally invasive plate osteosynthe- sis (MIPO) technique. The data consisted of 43 proximal tibial fractures (type AO41 C3) and 55 distal tibial fractures (type AO43C3). Results: No complications were observed in all patients after operation. The mean healing time was 8.4 months (range 5-14 months). Only two cases of delayed union oc- curred at postoperative 10 months. No infections were re- ported after the definitive surgery even in the cases of open fractures. All patients reached a full range of motion at post- operative 6 to 9 months and regained the normal functions of knee and ankle joints. Conclusion: Using LIF in MIPO technique is a reliable approach towards the proximal and distal tibial fractures that are not suitable for intramedullary nailing.
文摘Purpose: Distal radial fracture is one of the most common fractures. Up to now, locking plates (LP) and external fixation (EF) are two conventional surgical approaches to type C radius fracture. Which method is superior has not yet reached a consensus. We try to assess the clinical effectiveness of the two in- terventions by this meta-analysis. Methods: We used network to search the PubMed, Embase, and Cochrane Medical Library of randomized controlled clinical trials about the type C distal radius fractures performed according to the search strategy mentioned in Cochrane Handbook 5.1.0 from Jan. 2005 to Jan. 2016. Patients in the experimental group were used LP, in the control group were included EF and other surgical approaches. Publication language was restricted to English. Studies that patient population and surgical indication did not define had been excluded. Studies must report at least one of the outcomes as follow: radial inclination, patmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The trials in which participants included children were excluded. We used Jadad study scores to appraise the study. Results: Seven studies included 162 patients (LP group) and 190 patients (EF group). We compared the radial inclination, palmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The radial inclination were revealed a difference favoring LP over EF [WMD = 1.84, 95% CI (0.17, 3.50), p = 0.03] and the palmar tilt and ulnar variance was no significant difference between the two groups [(WMD = 3.61, 95% CI (0.00, 7.23), p = 0.05; WMD = 0.05, 95% CI (-0.99,1.09), p = 0.93]. The functional activities of range of flexion and extension and range of supination and pronation between the two groups was no difference [WMD = 10.04, 95% CI (-6.88, 26.96), p = 0.24; WMD = 12.53, 95% CI (-9.99, 35.06), p = 0.28]. Conclusion: Locking plate and external fixation is feasible to heal radius type C fracture. We found the small difference between the two groups on imaging examination. The locking plate has the advantage on maintaining reduction, however no significant difference regarding outcomes has been found be- tween the two groups.
文摘Objective To discuss the clinical effect of treatment with anterior decompression, bone graft and cervical locking plate fixation for cervical degeneration disease.Method 23 patients with cervical spondylotic myelopathy and cervical ossification of the posterior longitudinal ligament have undergone the treatment of anterior cervical spine locking plate fusion.Neurological signs and symptoms were evaluated before and after surgery, and mean follow up time was 11.3 months.Result In all cases,radiography demonstrated a solid bony fusion.Additional general complications include a large wound hematoma in one and hoarseness in one.All patients’ neurological function were improved.Conclusion The clinical effect of treatment with anterior decompression, bone graft and cervical locking plate fixation for cervical degeneration disease is satisfactory.
文摘Purpose:Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment.This study compared the functional outcomes between variable angle volar plating and external fixator with K-wire augmentation in open reduction and internal fixation.Methods:A total of 62 adult patients with comminuted intraarticular distal radius fracture were randomized into 2 groups:volar plate group and external fixator group.These patients aged between 18 and 60 years had unilateral fractures,and agreed to be included in the study.Patients with a history of fracture,bilateral fracture,associated other injuries,delayed injury for more than 2 weeks,open fracture,pre-existing arthrosis or disability,psychiatric illness and pathological fracture were excluded.Patients were followed up at 6 weeks,3 months,6 months and 1 year.The assessment of pain,functional activity,range of motion and grip strength was done at each stage of follow-up.The pain and functional activities were assessed by patient rated wrist evaluation(PRWE)score and disabilities of the arm,shoulder and hand(DASH)score.Results:Patients in volar plate group had superior PRWE score and DASH score at each stage of followup.At 1 year follow-up,the mean PRWE score were 7.48 for volar plate group and 7.35 for external fixator group;while the mean DASH score was 4.65 for volar plate group and 5.61 for external fixator group.They had better flexion and extension range of movement.They also had better pronation and supination range of motion at initial follow-up,however the difference get attenuated by 1 year.Volar plate group had significantly better grip strength than external fixator group.Complication rates were higher in external fixation group.Conclusion:Fixation with variable angle volar plate results in early wrist mobilization,better range of movement,less pain and disability and early return of function.