High-density electrical method has been proved to be an effective method for probing shallow sedimentary layers.It is principally used to identify the boundary between the Quaternary soil layer and bedrock according t...High-density electrical method has been proved to be an effective method for probing shallow sedimentary layers.It is principally used to identify the boundary between the Quaternary soil layer and bedrock according to the vertical change of apparent resistivity.However,the artificial filling layer has the characteristics of heterogeneity and high porosity,which makes it challenging to detect the artificial filling layer by high-density electrical method.The key to solve this problem is to detect the difference of conductivity between the filling layer and the underlying bedrock.This paper takes the land in Chengjiangshan area of Huaibei City,Anhui Province as the detection target.On the basis of fully analyzing the physical properties of the artificial filling layer,two-dimensional high-density electrical survey and inversion are used to define the thickness of the artificial filling layer.The research shows that the highdensity resistivity method has obvious advantages in delineating the distribution of bedrock and the thickness of the filling layer,and the reliability of the high-density electrical method in the detection of the artificial filling layer,and delineates the scope of the filling layer is verified by the borehole data.展开更多
The authors employ the high-density resistivity method to image the subsurface structure of a mountain in Erdaojiang District,Tonghua City,Jilin Province,China,to evaluate the potential risk of slope failure on surrou...The authors employ the high-density resistivity method to image the subsurface structure of a mountain in Erdaojiang District,Tonghua City,Jilin Province,China,to evaluate the potential risk of slope failure on surrounding residential areas and infrastructure,and identify a shallow fault that extends across the center of the mountain and is perpendicular to the mountain slope and accurately locate the spatial position and depth of another fault on the southern side of the mountain.The results provide an important basis for evaluating mountain slope stability.This study also demonstrates that the high-density resistivity method is effective for detecting mountain faults.展开更多
By determining the distribution and extent of geological structures surrounding the Mingyan Tunnel,Xicheng Town,Helong City,Jilin Province,we can evaluate the stability of the rock mass and assess potential hazards du...By determining the distribution and extent of geological structures surrounding the Mingyan Tunnel,Xicheng Town,Helong City,Jilin Province,we can evaluate the stability of the rock mass and assess potential hazards during tunnel construction.We use the high-density resistivity method to analyze the subsurface structure of the study area.Conductive anomalies are likely to represent joint and fissure systems within strongly weathered host rocks,and the bedrock surrounding the tunnel is relatively stable and does not contain well-developed faults.High-density resistivity analysis can provide valuable information in the context of tunnel engineering and safety.展开更多
This paper presents a self-contained description on the configuration of propagator method(PM)to calculate the electron velocity distribution function(EVDF) of electron swarms in gases under DC electric and magnetic f...This paper presents a self-contained description on the configuration of propagator method(PM)to calculate the electron velocity distribution function(EVDF) of electron swarms in gases under DC electric and magnetic fields crossed at a right angle. Velocity space is divided into cells with respect to three polar coordinates v,θ and f. The number of electrons in each cell is stored in three-dimensional arrays. The changes of electron velocity due to acceleration by the electric and magnetic fields and scattering by gas molecules are treated as intercellular electron transfers on the basis of the Boltzmann equation and are represented using operators called the propagators or Green’s functions. The collision propagator, assuming isotropic scattering, is basically unchanged from conventional PMs performed under electric fields without magnetic fields. On the other hand, the acceleration propagator is customized for rotational acceleration under the action of the Lorentz force. The acceleration propagator specific to the present cell configuration is analytically derived. The mean electron energy and average electron velocity vector in a model gas and SF6 were derived from the EVDF as a demonstration of the PM under the Hall deflection and they were in a fine agreement with those obtained by Monte Carlo simulations. A strategy for fast relaxation is discussed, and extension of the PM for the EVDF under AC electric and DC/AC magnetic fields is outlined as well.展开更多
Some unfavorable geological conditions can affect the construction of tunnels.In order to evaluate the damage degree of tunnel construction and determine the surrounding rock grade and stability of the tunnel,the auth...Some unfavorable geological conditions can affect the construction of tunnels.In order to evaluate the damage degree of tunnel construction and determine the surrounding rock grade and stability of the tunnel,the authors used high-density resistivity method to detect the surrounding rocks of Shimodong tunnel in Xicheng Town of Helong City.The underground resistivity structures of the entrance,exit and middle parts of the tunnel are obtained.Through analysis,it is found that there are no bedrock faults near the tunnel,although some joints and fissures are developed in some locations,which are characterized by low-resistivity anomalies.The tunnel structures are stable overall,favorable for safe and efficient construction.The study also proves the good application effect of the high-density resistivity method in tunnel safety detection.展开更多
The authors employ the high-density resistivity method during an archaeological investigation of Sumicheng site,an ancient city of the Tang Dynasty,to find evidence of human activities and locate a favorable target fo...The authors employ the high-density resistivity method during an archaeological investigation of Sumicheng site,an ancient city of the Tang Dynasty,to find evidence of human activities and locate a favorable target for archaeological excavation in the southern part of the outer city.There are two obvious high-resistivity structures,the south wall of the inner city and an ancient building near the south gate along the outer city wall,of which the resistivities are indicative of rammed soil foundations.The south wall of the inner city is continuous but is cut off abruptly to the east,which we suggest it is due to either wall damage or destruction.The resistivity signature of the target area is verified by archaeological excavation,proving the feasibility and effectiveness of implementing the high-density resistivity method for archaeological exploration.展开更多
The principles, methods, technologies and application effects of several electromagnetic methods for the detection of the hidden danger of water gushing at the coal face were introduced. Also, emphasis was laid on exp...The principles, methods, technologies and application effects of several electromagnetic methods for the detection of the hidden danger of water gushing at the coal face were introduced. Also, emphasis was laid on expounding the methods, principles and effects of down-hole detections by electric transmission tomography and transient electromagnetic method. The potential of point power supplied in the underground homogeneous semi-space, as well as the response to a low-resistivity abnormal body in the homogeneous semi-space, was simulated by adopting 3-D finite element method to interpret the basic theory of the electric transmission tomography. The results of actual measurement show that the mine electromagnetic method is sensitive to water-bearing low-resistivity bodies and can play a unique role in detecting the hidden danger of water gushing at the coal face.展开更多
Drilling a well randomly would lead to high uncertainties and could not meet the demand of water supply from the increasing population.It is in dire need to improve success rate of well drilling.The high-density resis...Drilling a well randomly would lead to high uncertainties and could not meet the demand of water supply from the increasing population.It is in dire need to improve success rate of well drilling.The high-density resistivity method offers us a good choice.In this study,high-density resistivity method is used for groundwater survey in five villages in the Taobei District of Baicheng.The data obtained by high-density resistivity method is inverted through Res2dinv software.It is found that the electrical structure is characterized by a horizontal layer distribution,and the resistivity shows a"high-medium low-low"feature from shallow to deep.Moreover,obvious electrical gradient zones are identified in the strata below each section,which are interpreted as tectonic weak zones,i.e.,the faults.The low-resistance anomaly areas are inferred to be favorable aquifers.The results show that high-density resistivity exploration is an efficient and practical method for determining water well sites in rural areas and can provide a guide for finding water resources in the area.展开更多
With the development of distribution automation system, the centralized meter reading system has been adopted more and more extensively, which provides real-time electricity consumption data of end-users, and conseque...With the development of distribution automation system, the centralized meter reading system has been adopted more and more extensively, which provides real-time electricity consumption data of end-users, and consequently lays foundation for operating condition on-line analysis of distribution network. In this paper, a modified back/forward sweep method, which directly uses real-time electricity consumption data acquired from the centralized meter reading system, is proposedto realize voltage analysis based on 24-hour electricity consumption data of a typical transformer district. Furthermore, the calculated line losses are verified through data collected from the energy metering of the distribution transformer, illustrating that the proposed method can be applied in analyzing voltage level and discovering unknown energy losses, which will lay foundation for on-line analysis, calculation and monitoring of power distribution network.展开更多
The situation of electricity in Pakistan has been alarming from the last ten years. The deficiency in electricity has not only obstructed the business activities but also affected the domestic consumers, educational i...The situation of electricity in Pakistan has been alarming from the last ten years. The deficiency in electricity has not only obstructed the business activities but also affected the domestic consumers, educational institutes and hospitals. Usually electrical power companies are liable for electricity shortfall and power interruption. However, electricity end consumers are also equally responsible behind strange shortfall and unusual power interruption. Frequently, the consumers use the heavy electrical equipment in their homes including heaters, geysers, irons and water motors which causes the more electricity consumption, load shedding and huge amount of bills. For escaping the huge amount of electricity bill, the consumers commit the illegal and unethical connections. The illegal usage of electrical power failed the power companies to plan schedule load shedding accordingly and the other side the damaged electricity wires or Pole Mount Transformer increased faults due to overburdening, which directly affected on extend power interruption. In addition that, responsible teams of electrical power companies cannot reach instantly to repair faults and prevent the theft. Electricity thieving is social crime committed by the consumers or meter readers which causes the electricity strange shortfall within country. This paper presents the practical demonstration about the common energy theft methods and techniques done by electricity consumers within their home and residential building. In Pakistan EPC (electrical power companies) deploy the traditional electromechanical meters for electricity consumption measurements, however, these meters do not have any real time communication. Therefore there are many easy ways to manipulate the meter reading as well as internal structural of metering system.展开更多
In this study we consider the boundary estimation of annular two-phase flow in a pipe with the potential distribution on the electrodes mounted on the outer boundary of the pipe, by taking use of electrical impedance ...In this study we consider the boundary estimation of annular two-phase flow in a pipe with the potential distribution on the electrodes mounted on the outer boundary of the pipe, by taking use of electrical impedance tomography (EIT) technique with the numerical solution obtained from an improved boundary distributed source (IBDS) method. The particle swarm optimization (PSO) is used to iteratively seek the boundary configuration. The simulation results showed that PSO and EIT technique with numerical solution obtained from IBDS has been successfully applied to the monitoring of an annular two-phase flow.展开更多
文摘High-density electrical method has been proved to be an effective method for probing shallow sedimentary layers.It is principally used to identify the boundary between the Quaternary soil layer and bedrock according to the vertical change of apparent resistivity.However,the artificial filling layer has the characteristics of heterogeneity and high porosity,which makes it challenging to detect the artificial filling layer by high-density electrical method.The key to solve this problem is to detect the difference of conductivity between the filling layer and the underlying bedrock.This paper takes the land in Chengjiangshan area of Huaibei City,Anhui Province as the detection target.On the basis of fully analyzing the physical properties of the artificial filling layer,two-dimensional high-density electrical survey and inversion are used to define the thickness of the artificial filling layer.The research shows that the highdensity resistivity method has obvious advantages in delineating the distribution of bedrock and the thickness of the filling layer,and the reliability of the high-density electrical method in the detection of the artificial filling layer,and delineates the scope of the filling layer is verified by the borehole data.
基金Supported by National Key R&D Program of China and Fundamental Research Funds for the Central Universities(2017YFC0601305)。
文摘The authors employ the high-density resistivity method to image the subsurface structure of a mountain in Erdaojiang District,Tonghua City,Jilin Province,China,to evaluate the potential risk of slope failure on surrounding residential areas and infrastructure,and identify a shallow fault that extends across the center of the mountain and is perpendicular to the mountain slope and accurately locate the spatial position and depth of another fault on the southern side of the mountain.The results provide an important basis for evaluating mountain slope stability.This study also demonstrates that the high-density resistivity method is effective for detecting mountain faults.
基金Supported by The National Natural Science Foundation of China(41504076)Jilin Science and Technological Development Program(20180101093JC)。
文摘By determining the distribution and extent of geological structures surrounding the Mingyan Tunnel,Xicheng Town,Helong City,Jilin Province,we can evaluate the stability of the rock mass and assess potential hazards during tunnel construction.We use the high-density resistivity method to analyze the subsurface structure of the study area.Conductive anomalies are likely to represent joint and fissure systems within strongly weathered host rocks,and the bedrock surrounding the tunnel is relatively stable and does not contain well-developed faults.High-density resistivity analysis can provide valuable information in the context of tunnel engineering and safety.
文摘This paper presents a self-contained description on the configuration of propagator method(PM)to calculate the electron velocity distribution function(EVDF) of electron swarms in gases under DC electric and magnetic fields crossed at a right angle. Velocity space is divided into cells with respect to three polar coordinates v,θ and f. The number of electrons in each cell is stored in three-dimensional arrays. The changes of electron velocity due to acceleration by the electric and magnetic fields and scattering by gas molecules are treated as intercellular electron transfers on the basis of the Boltzmann equation and are represented using operators called the propagators or Green’s functions. The collision propagator, assuming isotropic scattering, is basically unchanged from conventional PMs performed under electric fields without magnetic fields. On the other hand, the acceleration propagator is customized for rotational acceleration under the action of the Lorentz force. The acceleration propagator specific to the present cell configuration is analytically derived. The mean electron energy and average electron velocity vector in a model gas and SF6 were derived from the EVDF as a demonstration of the PM under the Hall deflection and they were in a fine agreement with those obtained by Monte Carlo simulations. A strategy for fast relaxation is discussed, and extension of the PM for the EVDF under AC electric and DC/AC magnetic fields is outlined as well.
基金National Key R&D Program of China(2017YFC0601305)Fundamental Research Funds for the Central Universities.
文摘Some unfavorable geological conditions can affect the construction of tunnels.In order to evaluate the damage degree of tunnel construction and determine the surrounding rock grade and stability of the tunnel,the authors used high-density resistivity method to detect the surrounding rocks of Shimodong tunnel in Xicheng Town of Helong City.The underground resistivity structures of the entrance,exit and middle parts of the tunnel are obtained.Through analysis,it is found that there are no bedrock faults near the tunnel,although some joints and fissures are developed in some locations,which are characterized by low-resistivity anomalies.The tunnel structures are stable overall,favorable for safe and efficient construction.The study also proves the good application effect of the high-density resistivity method in tunnel safety detection.
基金projects of Jilin Provincial Institute of Cultural Relics and Archaeology(No.3S318B564423)National Key R&D Program of China(No.2017YFC0601305)Fundamental Research Funds for the Central Universities.
文摘The authors employ the high-density resistivity method during an archaeological investigation of Sumicheng site,an ancient city of the Tang Dynasty,to find evidence of human activities and locate a favorable target for archaeological excavation in the southern part of the outer city.There are two obvious high-resistivity structures,the south wall of the inner city and an ancient building near the south gate along the outer city wall,of which the resistivities are indicative of rammed soil foundations.The south wall of the inner city is continuous but is cut off abruptly to the east,which we suggest it is due to either wall damage or destruction.The resistivity signature of the target area is verified by archaeological excavation,proving the feasibility and effectiveness of implementing the high-density resistivity method for archaeological exploration.
基金Supported by the National Basic Research of China(2006CB202207)the National Natural Science Foundation of China(40674060)
文摘The principles, methods, technologies and application effects of several electromagnetic methods for the detection of the hidden danger of water gushing at the coal face were introduced. Also, emphasis was laid on expounding the methods, principles and effects of down-hole detections by electric transmission tomography and transient electromagnetic method. The potential of point power supplied in the underground homogeneous semi-space, as well as the response to a low-resistivity abnormal body in the homogeneous semi-space, was simulated by adopting 3-D finite element method to interpret the basic theory of the electric transmission tomography. The results of actual measurement show that the mine electromagnetic method is sensitive to water-bearing low-resistivity bodies and can play a unique role in detecting the hidden danger of water gushing at the coal face.
基金Project of the National Natural Science Foundation(No.41874125).
文摘Drilling a well randomly would lead to high uncertainties and could not meet the demand of water supply from the increasing population.It is in dire need to improve success rate of well drilling.The high-density resistivity method offers us a good choice.In this study,high-density resistivity method is used for groundwater survey in five villages in the Taobei District of Baicheng.The data obtained by high-density resistivity method is inverted through Res2dinv software.It is found that the electrical structure is characterized by a horizontal layer distribution,and the resistivity shows a"high-medium low-low"feature from shallow to deep.Moreover,obvious electrical gradient zones are identified in the strata below each section,which are interpreted as tectonic weak zones,i.e.,the faults.The low-resistance anomaly areas are inferred to be favorable aquifers.The results show that high-density resistivity exploration is an efficient and practical method for determining water well sites in rural areas and can provide a guide for finding water resources in the area.
文摘With the development of distribution automation system, the centralized meter reading system has been adopted more and more extensively, which provides real-time electricity consumption data of end-users, and consequently lays foundation for operating condition on-line analysis of distribution network. In this paper, a modified back/forward sweep method, which directly uses real-time electricity consumption data acquired from the centralized meter reading system, is proposedto realize voltage analysis based on 24-hour electricity consumption data of a typical transformer district. Furthermore, the calculated line losses are verified through data collected from the energy metering of the distribution transformer, illustrating that the proposed method can be applied in analyzing voltage level and discovering unknown energy losses, which will lay foundation for on-line analysis, calculation and monitoring of power distribution network.
文摘The situation of electricity in Pakistan has been alarming from the last ten years. The deficiency in electricity has not only obstructed the business activities but also affected the domestic consumers, educational institutes and hospitals. Usually electrical power companies are liable for electricity shortfall and power interruption. However, electricity end consumers are also equally responsible behind strange shortfall and unusual power interruption. Frequently, the consumers use the heavy electrical equipment in their homes including heaters, geysers, irons and water motors which causes the more electricity consumption, load shedding and huge amount of bills. For escaping the huge amount of electricity bill, the consumers commit the illegal and unethical connections. The illegal usage of electrical power failed the power companies to plan schedule load shedding accordingly and the other side the damaged electricity wires or Pole Mount Transformer increased faults due to overburdening, which directly affected on extend power interruption. In addition that, responsible teams of electrical power companies cannot reach instantly to repair faults and prevent the theft. Electricity thieving is social crime committed by the consumers or meter readers which causes the electricity strange shortfall within country. This paper presents the practical demonstration about the common energy theft methods and techniques done by electricity consumers within their home and residential building. In Pakistan EPC (electrical power companies) deploy the traditional electromechanical meters for electricity consumption measurements, however, these meters do not have any real time communication. Therefore there are many easy ways to manipulate the meter reading as well as internal structural of metering system.
文摘In this study we consider the boundary estimation of annular two-phase flow in a pipe with the potential distribution on the electrodes mounted on the outer boundary of the pipe, by taking use of electrical impedance tomography (EIT) technique with the numerical solution obtained from an improved boundary distributed source (IBDS) method. The particle swarm optimization (PSO) is used to iteratively seek the boundary configuration. The simulation results showed that PSO and EIT technique with numerical solution obtained from IBDS has been successfully applied to the monitoring of an annular two-phase flow.