期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Jensen-Renyi’s-Tsallis Fuzzy Divergence Information Measure with its Applications
1
作者 Ratika Kadian Satish Kumar 《Communications in Mathematics and Statistics》 SCIE 2022年第3期451-482,共32页
In this paper,we have characterized the sum of two general measures associated with two distributions with discrete random variables.One of these measures is logarithmic,while others contains the power of variables,na... In this paper,we have characterized the sum of two general measures associated with two distributions with discrete random variables.One of these measures is logarithmic,while others contains the power of variables,named as joint representation of Renyi’s-Tsallis divergence measure.Then,we propose a divergence measure based on Jensen-Renyi’s-Tsallis entropy which is known as a Jensen-Renyi’s-Tsallis divergence measure.It is a generalization of J-divergence information measure.One of the silent features of this measure is that we can allot the equal weight to each probability distribution.This makes it specifically reasonable for the study of decision problems,where the weights could be the prior probabilities.Further,the idea has been generalized from probabilistic to fuzzy similarity/dissimilarity measure.Besides the validation of the proposed measure,some of its key properties are also studied.Further,the performance of the proposed measure is contrasted with some existing measures.At last,some illustrative examples are solved in the context of clustering analysis,financial diagnosis and pattern recognition which demonstrate the practicality and adequacy of the proposed measure between two fuzzy sets(FSs). 展开更多
关键词 Fuzzy sets divergence measure Similarity measure Clustering analysis Financial diagnosis
原文传递
GEOMETRY ON THE WASSERSTEIN SPACE OVER A COMPACT RIEMANNIAN MANIFOLD
2
作者 丁昊 Shizan FANG 《Acta Mathematica Scientia》 SCIE CSCD 2021年第6期1959-1984,共26页
We revisit the intrinsic differential geometry of the Wasserstein space over a Riemannian manifold,due to a series of papers by Otto,Otto-Villani,Lott,Ambrosio-Gigli-Savaré,etc.
关键词 constant vector fields measures having divergence Levi-Civita connection parallel translations Mckean-Vlasov equations
下载PDF
Study on direct point spread function measurement of capillary plate collimators with divergent X-ray beams
3
作者 Tianming Li Tao Luo +2 位作者 Yupeng Xu Huilin He Liming Song 《Radiation Detection Technology and Methods》 CSCD 2023年第3期321-336,共16页
Purpose The Filed of View(FOV)of eXTP/LAD is limited by lead-glass capillary plate collimators placed in front of the Silicon Drift Detectors(SDDs)for reducing the background contamination caused by the photons of Cos... Purpose The Filed of View(FOV)of eXTP/LAD is limited by lead-glass capillary plate collimators placed in front of the Silicon Drift Detectors(SDDs)for reducing the background contamination caused by the photons of Cosmic X-ray Background(CXB)leaking from outside the FOV.The core quality parameters of lead-glass capillary plate collimators are Open Area Ratio(OAR)and FOV.The performance of lead-glass capillary plate collimators is determined by its design specification such as pore-to-pore misalignment,pore perpendicularity with collimator surface and pore diameter.Since the design specification is the result of a large number of micropores,we use the full width at half maximum(FWHM)and peak value of point spread function(PSF)to characterize the capillary plate collimator performance.In order to quickly evaluate the performances of collimators,we developed a direct PSF measurement method using divergent beams.Methods In this paper,the simulation package of the divergent beamsmeasurement setup is developed based on Geant4.The simulation parameters of scintillator absorption length are corrected by experimental data.We simulate the PSF of collimators with different distribution of pore diameter and misalignment by parallel beams and divergent beams.By comparing the peak value and FWHM of collimators PSF,the feasibility in replacing parallel beams measurement with divergent beams measurement is studied.Results It is verified that the influence of the geometric size of 33μm radius of the micro-focus of X-ray tube can be ignored.The results show that the FWHM of collimators is increased with error root mean square error(RMS)of the distribution of collimators pore diameter and pore inclination angle.The peak value of PSF is mainly influenced by pore non-parallelism of the pores,and it decreases with an increase in pore inclination angle.Comparison of parallel beams PSF and divergent beams PSF shows well consistency of peak value and FWHM of collimator.But,the peak value of the divergent beams PSF is mainly affected by the defects of the pores close to the optical axis and result in difference from the parallel beams results consequently.We have developed capillary plate collimators response function based on the projected area function of a cylindrical pore and the fluorescence broadening of the scintillator and fitted PSF by response function.The capillary plate collimator open area ratio is calculated by using the micropores radius and collimator frame thickness obtained by fitting parameter,and the result is close to the parallel beams PSF.Conclusion The feasibility divergent beams measurement is verified. 展开更多
关键词 GEANT4 EXTP/LAD Capillary plate collimators Divergent X-ray beams measurment
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部