When the plant protection UAV is spraying on plants, the operator usually performs visual inspection on the vertical distance between the UAV and the plant to adjust the spray height to complete the application. Visua...When the plant protection UAV is spraying on plants, the operator usually performs visual inspection on the vertical distance between the UAV and the plant to adjust the spray height to complete the application. Visual inspection by human eyes is easy to cause the error of spray deposition and deposition density. In order to improve the full utilization of drugs and the spraying efficiency of plant protection UAV, an efficient adaptive spray plant protection UAV was designed, and the vertical distance from the UAV to the plant was collected by ultrasonic wave. Meantime, the plant density was detected in real time, and the flight attitude of plant protection UAV and application rate of spray nozzle were automatically adjusted. The experimental results showed that the designed highly efficient adaptive spray plant protection UAV had fast response speed, precise spray location and less drug loss.展开更多
Quasi-PID control method that is able to effectively inhibit the inherent tracking error of PI control method is proposed on the basis of a rounded theoretical analysis of a model of switching power amplifiers (SPAs)....Quasi-PID control method that is able to effectively inhibit the inherent tracking error of PI control method is proposed on the basis of a rounded theoretical analysis of a model of switching power amplifiers (SPAs). To avoid the harmful impacts of the circuit parameter variations and the random disturbances on quasi-PID control method, a single neuron is introduced to endow it with self-adaptability. Quasi-PID control method and the single neuron combine with each other perfectly, and their formation is named as single-neuron adaptive quasi-PID control method. Simulation and experimental results show that single-neuron adaptive quasi-PID control method can accurately track both the predictable and the unpredictable waveforms. Quantitative analysis demonstrates that the accuracy of single-neuron adaptive quasi-PID control method is comparable to that of linear power amplifiers (LPAs) and so can fulfill the requirements of some high-accuracy applications, such as protective relay test. Such accuracy is very difficult to be achieved by many modern control methods for converter controls. Compared with other modern control methods, the programming realization of single-neuron adaptive quasi-PID control method is more suitable for real-time applications and realization on low-end microprocessors for its simple structure and lower computational complexity.展开更多
A fault identification scheme for protection and adaptive reclosing is proposed for a hybrid multi-terminal HVDC system to increase the reliability of fault isolation and reclosing.By analyzing the"zero passing&q...A fault identification scheme for protection and adaptive reclosing is proposed for a hybrid multi-terminal HVDC system to increase the reliability of fault isolation and reclosing.By analyzing the"zero passing"characteristic of current at the local end during the converter capacitor discharge stage,the fault identification scheme is proposed.The distributed parameter-based fault location equation,which incorporates fault distance and fault impedance,is developed with the injection signal and the distributed parameter model during the adaptive reclosing stage.The fault distance is determined using a trust region reflection algorithm to identify the permanent fault,and a fault iden-tification scheme for adaptive reclosing is developed.Simulation results show that the proposed scheme is suitable for long-distance transmission lines with strong anti-fault impedance and anti-interference performance.Also,it is less affected by communication delay and DC boundary strength than existing methods.展开更多
In the 21st century, landscape ecology should be able to design the environmental construction. The landscape ecological construction is to protect biological diversity positively, which follows the theories such as a...In the 21st century, landscape ecology should be able to design the environmental construction. The landscape ecological construction is to protect biological diversity positively, which follows the theories such as adapting to nature, mutualism and symbiosis, adjusting structure and improving function, controlling parts and adjusting the whole, and other theories of landscape ecology. This paper took humid temperate zones, landscape ecozones etc. as examples to express how to use these theories to carry out landscape ecological construction. The author put forth three points of land ecological construction: protection of rare and endangered organisms; restoration and reconstruction of important ecosystems; protection of community diversity of plant.展开更多
Faced with the conflict between the environmental protection and timber production, the concept of new forestry and the effect of new forestry objectives on existing harvesting techniques and equipment have been intro...Faced with the conflict between the environmental protection and timber production, the concept of new forestry and the effect of new forestry objectives on existing harvesting techniques and equipment have been introduced. Adaptive management-a help tool for developing new harvesting techniques and equipment has been proposed. An adaptive approach for developing a forest harvesting for new forestry should be composed of careful planing, considerable hypotheses, detailed testing and evaluating as well as correct and fast feedback. New forestry practices are by no means easy because the complexity of the problem and almost every thing is new. We will see more successful new harvesting techniques and equipment being developing by adaptive approach for new forestry in the future.展开更多
This paper presents a technique that increases the second-zone coverage of distance relays without causing overreach problems. The technique is based on the impedance seen by distance relays when faults are simulated ...This paper presents a technique that increases the second-zone coverage of distance relays without causing overreach problems. The technique is based on the impedance seen by distance relays when faults are simulated on the reach of zone-1 relays. The approach checks the relay operation for the maximum as well as the minimum generation outputs of the power system. The proposed technique can be used for different reach setting for zone-1. Results show that it is possible to increase the coverage provided by zone-2 distance relays without causing coordination problems with the primary relays that protect the lines emanating from the remote bus. The proposed method is modified for use in an adaptive protection system. It is shown that further improvements can be achieved when settings are calculated using the proposed method and the prevailing system conditions. The proposed method and its adaptive version were applied to a part of the Power system. The simulation of the system is done by using PSCAD-EMTDC software. The simulated results are observed and compared with the conventional and proposed technique.展开更多
Traditional garden is a vital element of traditional cultural heritage in China, and it is a common concern of the public to protect, inherit and develop traditional cultural heritage. This paper, on the basis of inve...Traditional garden is a vital element of traditional cultural heritage in China, and it is a common concern of the public to protect, inherit and develop traditional cultural heritage. This paper, on the basis of investigating current protection of royal gardens, private gardens in southern regions of the Yangtze River, and gardens in different regions, summarized 4 fundamental modes of traditional garden protection, namely protective development mode, developmental protection mode, controlled protection mode, no-protection mode. Advantages and disadvantages of different modes were reviewed, protective development was proposed as a traditional garden protection mode adaptive to actual conditions of China.展开更多
SiC MOSFET因其高击穿电压、高开关速度、低导通损耗等性能优势而被广泛应用于各类电力电子变换器中。然而,由于其短路耐受时间仅为2~7μs,且随母线电压升高而缩短,快速可靠的短路保护电路已成为其推广应用的关键技术之一。为应对不同...SiC MOSFET因其高击穿电压、高开关速度、低导通损耗等性能优势而被广泛应用于各类电力电子变换器中。然而,由于其短路耐受时间仅为2~7μs,且随母线电压升高而缩短,快速可靠的短路保护电路已成为其推广应用的关键技术之一。为应对不同母线电压下的Si C MOSFET短路故障,文中提出一种基于漏源电压积分的自适应快速短路保护方法(drain-sourcevoltageintegration-basedadaptivefast short-circuit protection method,DSVI-AFSCPM),研究所提出的DSVI-AFSCPM在硬开关短路(hardswitchingfault,HSF)和负载短路(fault under load,FUL)条件下的保护性能,进而研究不同母线电压对DSVI-AFSCPM的作用机理。同时,探究Si CMOSFET工作温度对其响应速度的影响。最后,搭建实验平台,对所提出的DSVI-AFSCPM在发生硬开关短路和负载短路时不同母线电压、不同工作温度下的保护性能进行实验测试。实验结果表明,所提出的DSVI-AFSCPM在不同母线电压下具有良好的保护速度自适应性,即母线电压越高,短路保护速度越快,并且其响应速度受Si CMOSFET工作温度影响较小,两种短路工况下工作温度从25℃变化到125℃,短路保护时间变化不超过90 ns。因此,该文为Si CMOSFET在不同母线电压下的可靠使用提供一定技术支撑。展开更多
基金Supported by Natural Science Foundation of Uygur Autonomous Region in 2020(2020D01C003)。
文摘When the plant protection UAV is spraying on plants, the operator usually performs visual inspection on the vertical distance between the UAV and the plant to adjust the spray height to complete the application. Visual inspection by human eyes is easy to cause the error of spray deposition and deposition density. In order to improve the full utilization of drugs and the spraying efficiency of plant protection UAV, an efficient adaptive spray plant protection UAV was designed, and the vertical distance from the UAV to the plant was collected by ultrasonic wave. Meantime, the plant density was detected in real time, and the flight attitude of plant protection UAV and application rate of spray nozzle were automatically adjusted. The experimental results showed that the designed highly efficient adaptive spray plant protection UAV had fast response speed, precise spray location and less drug loss.
文摘Quasi-PID control method that is able to effectively inhibit the inherent tracking error of PI control method is proposed on the basis of a rounded theoretical analysis of a model of switching power amplifiers (SPAs). To avoid the harmful impacts of the circuit parameter variations and the random disturbances on quasi-PID control method, a single neuron is introduced to endow it with self-adaptability. Quasi-PID control method and the single neuron combine with each other perfectly, and their formation is named as single-neuron adaptive quasi-PID control method. Simulation and experimental results show that single-neuron adaptive quasi-PID control method can accurately track both the predictable and the unpredictable waveforms. Quantitative analysis demonstrates that the accuracy of single-neuron adaptive quasi-PID control method is comparable to that of linear power amplifiers (LPAs) and so can fulfill the requirements of some high-accuracy applications, such as protective relay test. Such accuracy is very difficult to be achieved by many modern control methods for converter controls. Compared with other modern control methods, the programming realization of single-neuron adaptive quasi-PID control method is more suitable for real-time applications and realization on low-end microprocessors for its simple structure and lower computational complexity.
基金supported by the Technology Projects of Southern Power Grid Electric Power Research Institute of China(SEPRI-K22B055)National Nature Science Foundation project(2021YFB1507000,2021YFB1507004)the Natural Science Foundation of Xinjiang Uygur Autonomous Region(2022D01C662).
文摘A fault identification scheme for protection and adaptive reclosing is proposed for a hybrid multi-terminal HVDC system to increase the reliability of fault isolation and reclosing.By analyzing the"zero passing"characteristic of current at the local end during the converter capacitor discharge stage,the fault identification scheme is proposed.The distributed parameter-based fault location equation,which incorporates fault distance and fault impedance,is developed with the injection signal and the distributed parameter model during the adaptive reclosing stage.The fault distance is determined using a trust region reflection algorithm to identify the permanent fault,and a fault iden-tification scheme for adaptive reclosing is developed.Simulation results show that the proposed scheme is suitable for long-distance transmission lines with strong anti-fault impedance and anti-interference performance.Also,it is less affected by communication delay and DC boundary strength than existing methods.
文摘In the 21st century, landscape ecology should be able to design the environmental construction. The landscape ecological construction is to protect biological diversity positively, which follows the theories such as adapting to nature, mutualism and symbiosis, adjusting structure and improving function, controlling parts and adjusting the whole, and other theories of landscape ecology. This paper took humid temperate zones, landscape ecozones etc. as examples to express how to use these theories to carry out landscape ecological construction. The author put forth three points of land ecological construction: protection of rare and endangered organisms; restoration and reconstruction of important ecosystems; protection of community diversity of plant.
文摘Faced with the conflict between the environmental protection and timber production, the concept of new forestry and the effect of new forestry objectives on existing harvesting techniques and equipment have been introduced. Adaptive management-a help tool for developing new harvesting techniques and equipment has been proposed. An adaptive approach for developing a forest harvesting for new forestry should be composed of careful planing, considerable hypotheses, detailed testing and evaluating as well as correct and fast feedback. New forestry practices are by no means easy because the complexity of the problem and almost every thing is new. We will see more successful new harvesting techniques and equipment being developing by adaptive approach for new forestry in the future.
文摘This paper presents a technique that increases the second-zone coverage of distance relays without causing overreach problems. The technique is based on the impedance seen by distance relays when faults are simulated on the reach of zone-1 relays. The approach checks the relay operation for the maximum as well as the minimum generation outputs of the power system. The proposed technique can be used for different reach setting for zone-1. Results show that it is possible to increase the coverage provided by zone-2 distance relays without causing coordination problems with the primary relays that protect the lines emanating from the remote bus. The proposed method is modified for use in an adaptive protection system. It is shown that further improvements can be achieved when settings are calculated using the proposed method and the prevailing system conditions. The proposed method and its adaptive version were applied to a part of the Power system. The simulation of the system is done by using PSCAD-EMTDC software. The simulated results are observed and compared with the conventional and proposed technique.
基金Sponsored by National Natural Science Foundation of China(51208429)
文摘Traditional garden is a vital element of traditional cultural heritage in China, and it is a common concern of the public to protect, inherit and develop traditional cultural heritage. This paper, on the basis of investigating current protection of royal gardens, private gardens in southern regions of the Yangtze River, and gardens in different regions, summarized 4 fundamental modes of traditional garden protection, namely protective development mode, developmental protection mode, controlled protection mode, no-protection mode. Advantages and disadvantages of different modes were reviewed, protective development was proposed as a traditional garden protection mode adaptive to actual conditions of China.