Self-heating and electric field distribution are the primary factors affecting the accuracy of the Ultra High Voltage Direct Current(UHVDC)resistive divider.Reducing the internal temperature rise of the voltage divide...Self-heating and electric field distribution are the primary factors affecting the accuracy of the Ultra High Voltage Direct Current(UHVDC)resistive divider.Reducing the internal temperature rise of the voltage divider caused by self-heating,reducing the maximum electric field strength of the voltage divider,and uniform electric field distribution can effectively improve the UHVDC resistive divider’s accuracy.In this paper,thermal analysis and electric field distribution optimization design of 1200 kV UHVDC resistive divider are carried out:(1)Using the proposed iterative algorithm,the heat dissipation and temperature distribution of the high voltage DC resistive divider are studied,and the influence of the ambient temperature and the power of the divider on the temperature of the insulating medium of the divider is analyzed;(2)Established the finite element models of 1200 kV and 2×600 kV DC resistive dividers,analyzed the influence of the size of the grading ring and the installation position on the maximum electric field strength of the voltage divider,and calculated the impact of the shielding resistor layer on the vicinity of the measuring resistor layer.The research indicates that:(1)The temperature of the insulating medium is linearly related to the horsepower of the voltage divider and the ambient temperature;(2)After the optimized design of the electric field,the maximum electric field strength of the 1200 kV DC resistive divider is reduced to 1471 V/mm,which is about 24% lower than that of the unoptimized design;(3)Installing the shielding resistor layer can significantly improve the electric field near the measuring resistor layer.This paper has an important reference function for improving the accuracy of the UHVDC resistive divider.展开更多
A miniaturized broadband Wilkinson power divider is proposed. Micro-strip branch lines are introduced to replace multiple resistors used in multi-stage Wilkinson power dividers to increase the bandwidth of single-stag...A miniaturized broadband Wilkinson power divider is proposed. Micro-strip branch lines are introduced to replace multiple resistors used in multi-stage Wilkinson power dividers to increase the bandwidth of single-stage Wilkinson power dividers. To demonstrate its performance, an improved single-stage Wilkinson power divider with four micro-strip branch lines was designed. Simulated results show that the insert loss is better than 3.2 dB, the input return loss, output return loss, and isolation are better than 15 dB respectively, across a 76% bandwidth from 18 to 40 GHz. .展开更多
基金supported by the Science and Technology Project of China Electric Power Research Institute,Research on 1200 kV DC Voltage Proportional Metering Technology with Weak Environmental Sensitivity and Development of Standard Devices(JL83-21-002).
文摘Self-heating and electric field distribution are the primary factors affecting the accuracy of the Ultra High Voltage Direct Current(UHVDC)resistive divider.Reducing the internal temperature rise of the voltage divider caused by self-heating,reducing the maximum electric field strength of the voltage divider,and uniform electric field distribution can effectively improve the UHVDC resistive divider’s accuracy.In this paper,thermal analysis and electric field distribution optimization design of 1200 kV UHVDC resistive divider are carried out:(1)Using the proposed iterative algorithm,the heat dissipation and temperature distribution of the high voltage DC resistive divider are studied,and the influence of the ambient temperature and the power of the divider on the temperature of the insulating medium of the divider is analyzed;(2)Established the finite element models of 1200 kV and 2×600 kV DC resistive dividers,analyzed the influence of the size of the grading ring and the installation position on the maximum electric field strength of the voltage divider,and calculated the impact of the shielding resistor layer on the vicinity of the measuring resistor layer.The research indicates that:(1)The temperature of the insulating medium is linearly related to the horsepower of the voltage divider and the ambient temperature;(2)After the optimized design of the electric field,the maximum electric field strength of the 1200 kV DC resistive divider is reduced to 1471 V/mm,which is about 24% lower than that of the unoptimized design;(3)Installing the shielding resistor layer can significantly improve the electric field near the measuring resistor layer.This paper has an important reference function for improving the accuracy of the UHVDC resistive divider.
文摘A miniaturized broadband Wilkinson power divider is proposed. Micro-strip branch lines are introduced to replace multiple resistors used in multi-stage Wilkinson power dividers to increase the bandwidth of single-stage Wilkinson power dividers. To demonstrate its performance, an improved single-stage Wilkinson power divider with four micro-strip branch lines was designed. Simulated results show that the insert loss is better than 3.2 dB, the input return loss, output return loss, and isolation are better than 15 dB respectively, across a 76% bandwidth from 18 to 40 GHz. .