The mechanical properties of residual coal pillars under the influence of upward mining disturbances significantly affect the safety of residual mining activities on working faces.This study conducted low-frequency di...The mechanical properties of residual coal pillars under the influence of upward mining disturbances significantly affect the safety of residual mining activities on working faces.This study conducted low-frequency disturbance dynamic uniaxial compression tests on coal specimens using a self-developed dynamic-static load coupling electro-hydraulic servo system,and studied the strength evolutions,surface deformations,acoustic emission(AE)characteristic parameters,and the failure modes of coal specimens with different static preloading levels were studied.The disturbance damage is positively correlated with the coal specimen static preload level.Specifically,the cumulative AE count rates of the initial accelerated damage stage for the coal specimens with static preloading level of 60%and 70%of the uniaxial compressive strength(UCS)were 2.66 and 3.19 times that of the 50%UCS specimens,respectively.Macroscopically,this behaviour manifested as a decrease in the compressive strength,and the mean strengths of the disturbance-damaged coal specimens with 60%and 70%of UCS static preloading decreased by 8.53%and 9.32%,respectively,compared to those of the specimens under pure static loading.The crack sources,such as the primary fissures,strongly control the dynamic response of the coal specimen.The difference between the dynamic responses of the coal specimens and that of dense rocks is significant.展开更多
Objective The causal agent for SARS is considered as a novel coronavirus that has never been described both in human and animals previously. The stability of SARS coronavirus in human specimens and in environments was...Objective The causal agent for SARS is considered as a novel coronavirus that has never been described both in human and animals previously. The stability of SARS coronavirus in human specimens and in environments was studied. Methods Using a SARS coronavirus strain CoV-P9, which was isolated from pharyngeal swab of a probable SARS case in Beijing, its stability in mimic human specimens and in mimic environment including surfaces of commonly used materials or in household conditions, as well as its resistances to temperature and UV irradiation were analyzed. A total of 106 TCID50 viruses were placed in each tested condition, and changes of the viral infectivity in samples after treatments were measured by evaluating cytopathic effect (CPE) in cell line Vero-E6 at 48 h after infectionn. Results The results showed that SARS coronavirus in the testing condition could survive in serum, 1:20 diluted sputum and feces for at least 96 h, whereas it could remain alive in urine for at least 72 h with a low level of infectivity. The survival abilities on the surfaces of eight different materials and in water were quite comparable, revealing reduction of infectivity after 72 to 96 h exposure. Viruses stayed stable at 4℃, at room temperature (20℃) and at 37℃ for at least 2 h without remarkable change in the infectious ability in cells, but were converted to be non-infectious after 90-, 60- and 30-min exposure at 56℃, at 67℃ and at 75℃, respectively. Irradiation of UV for 60 min on the virus in culture medium resulted in the destruction of viral infectivity at an undetectable level. Conclusion The survival ability of SARS coronavirus in human specimens and in environments seems to be relatively strong. Heating and UV irradiation can efficiently eliminate the viral infectivity.展开更多
AIM: To investigate the prevalence and implications of unusual histopathological findings in appendectomy specimens from patients with suspected acute appendicitis. METHODS: The demographic and histopathological data ...AIM: To investigate the prevalence and implications of unusual histopathological findings in appendectomy specimens from patients with suspected acute appendicitis. METHODS: The demographic and histopathological data of 1621 patients (≥ 16 years-old) who underwent appendectomy to treat an initial diagnosis of acute appendicitis between January 1999 and November 2011 were retrospectively assessed. Microscopic findings were used to classify the patients under six categories: appendix vermiformis, phlegmonous appendicitis, gan- grenous appendicitis, perforated appendicitis, supurative appendicitis, and unusual histopathologic findings. The demographic and clinicopathologic characteristics of patients with unusual histopathologic findings were evaluated in detail, and re-analysis of archived resected appendix specimens was carried out. RESULTS: A total of 912 males and 709 females, from16 to 94 years old, were included in the study and comprised 789 cases of suppurative appendicitis, 370 cases of appendix vermiformis, 243 cases of perforated gangrenous appendicitis, 53 cases of flegmaneous appendicitis, 32 cases of gangrenous appendicitis, and 134 (8.3%) cases of unusual histopathological findings. The unusual histopathological findings included fibrous obliteration (n = 62), enterobius vermicularis (n = 31), eosinophilic infiltration (n = 10), mucinous cystadenoma (n = 8), carcinoid tumor (n = 6), granulomatous inflammation (n = 5), adenocarcinoma (n = 4; one of them mucinous), and mucocele (n = 3), adenomatous polyp (n = 1), taenia sup (n = 1), ascaris lumbricoides (n = 1), appendiceal diverticula (n = 1), and B cell non-hodgkin lymphoma (n = 1). None of the 11 patients with subsequent diagnosis of tumor were suspected of cancer prior to the appendectomy. CONCLUSION: Even when the macroscopic appearance of appendectomy specimens is normal, histopathological assessment will allow early diagnosis of many unusual diseases.展开更多
Objective To provide a feasible and cost-effective next-generation sequencing (NGS) method for accurate identification of viral pathogens in clinical specimens, because enormous limitations impede the clinical use o...Objective To provide a feasible and cost-effective next-generation sequencing (NGS) method for accurate identification of viral pathogens in clinical specimens, because enormous limitations impede the clinical use of common NGS, such as high cost, complicated procedures, tremendous data analysis, and high background noise in clinical samples. Methods Viruses from cell culture materials or clinical specimens were identified following an improved NGS procedure: reduction of background noise by sample preprocessing, viral enrichment by barcoded oligonucleotide (random hexamer or non-ribosomal hexanucleotide) primer-based amplification, fragmentation-free library construction and sequencing of one-tube mixtures, as well as rapid data analysis using an in-house pipeline. Results NGS data demonstrated that both barcoded primer sets were useful to simultaneously capture multiple viral pathogens in cell culture materials or clinical specimens and verified that hexanucleotide primers captured as many viral sequences as hexamers did. Moreover, direct testing of clinical specimens using this improved hexanucleotide primer-based NGS approach provided further detailed genotypes of enteroviruses causing hand, foot, and mouth disease (HFMD) and identified other potential viruses or differentiated misdiagnosis events. Conclusion The improved barcoded oligonucleotide primer-based NGS approach is simplified, time saving, cost effective, and appropriate for direct identification of viral pathogens in clinical practice.展开更多
In recent years,the avian influenza has brought not only serious economic loss to the poultry industry in China but also a serious threat to human health because of the avian influenza virus(AIV) gene recombination an...In recent years,the avian influenza has brought not only serious economic loss to the poultry industry in China but also a serious threat to human health because of the avian influenza virus(AIV) gene recombination and reassortment.Until now,traditional RT-PCR,fluorescence RT-PCR and virus isolation identification have been developed and utilized to detect AIV,but these methods require high-level instruments and experimental conditions,not suitable for the rapid detection in field and farms.In order to develop a rapid,sensitive and practical method to detect and identify AIV subtypes,4 specific primers to the conserved region of AIV M gene were designed and a loop-mediated isothermal amplification(RT-LAMP) method was established.Using this method,the M gene of H1–H16 subtypes of AIV were amplified in 30 min with a water bath and all 16 H subtypes of AIV were able to be visually identified in presence of fluorescein,without cross reaction with other susceptible avian viruses.In addition,the detection limit of the common H1,H5,H7,and H9 AIV subtypes with the RT-LAMP method was 0.1 PFU(plaque-forming unit),which was 10 times more sensitive than that using the routine RT-PCR.Further comparative tests found that the positivity rate of RT-LAMP on detecting clinical samples was 4.18%(14/335) comparing with 3.58%(12/335) from real-time RT-PCR.All these results suggested that the RT-LAMP method can specifically detect and identify AIV with high sensitivity and can be considered as a fast,convenient and practical method for the clinic test and epidemiological investigation of AIV.展开更多
BACKGROUND Pathological manifestations of hepatic tumours are often associated with prognosis. Although surgical specimens(SS) can provide more information,currently, pre-treatment needle core biopsy(NCB) is increasin...BACKGROUND Pathological manifestations of hepatic tumours are often associated with prognosis. Although surgical specimens(SS) can provide more information,currently, pre-treatment needle core biopsy(NCB) is increasingly showing important value in understanding the nature of liver tumors and even in diagnosis and treatment decisions. However, the concordance of the clinicopathological characteristics and immunohistochemical(IHC) staining between NCB and SS from patients with hepatic tumours were less concerned.AIM To introduce a more accurate method for interpreting the IHC staining results in order to improve the diagnostic value of hepatic malignancy in NCB samples.METHOD A total of 208 patients who underwent both preoperative NCB and surgical resection for hepatocellular carcinoma(HCC) or intrahepatic cholangiocarcinomaRESULTS Morphologically, the presence of compact tumour nests or a cord-like structure in NCB was considered the primary cause of misdiagnosis of HCC from ICC. The kappa statistic showed a moderate agreement in histomorphology(k = 0.504) and histological grade(k = 0.488) between NCB and SS of the tumours. A 4-tier(+++,++, +, and-) scoring scheme that emphasized the focal neoplastic cell immunoreactivity of tumour cells revealed perfect concordance of CK19, GPC3 and HepPar1 between NCB and SS(k = 0.717; k = 0.768; k = 0.633). Furthermore,with the aid of a binary classification derived from the 4-tier score, a high concordance was achieved in interpreting the IHC staining of the three markers between NCB and final SS(k = 0.931; k = 0.907; k = 0.803), increasing the accuracy of NCB diagnosis C(k = 0.987; area under the curve = 0.997, 95%CI: 0.990-1.000; P< 0.001).CONCLUSION These findings imply that reasonable interpretation of IHC results in NCB is vital for improving the accuracy of tumour diagnosis. The simplified binary classification provides an easy and applicable approach.展开更多
The mechanism of cracks propagation and cracks coalescence due to compressive loading of the brittle substances containing pre-existing cracks (flaws) was modeled experimentally using specially made rock-like specim...The mechanism of cracks propagation and cracks coalescence due to compressive loading of the brittle substances containing pre-existing cracks (flaws) was modeled experimentally using specially made rock-like specimens from Portland Pozzolana Cement (PPC). The breakage process of the specimens was studied by inserting single and double flaws with different inclination angles at the center and applying uniaxial compressive stress at both ends of the specimen. The first crack was oriented at 50&#176; from the horizontal direction and kept constant throughout the analysis while the orientation of the second crack was changed. It is experimentally observed that the wing cracks are produced at the first stage of loading and start their propagation toward the direction of uniaxial compressive loading. The secondary cracks may also be produced in form of quasi-coplanar and/or oblique cracks in a stable manner. The secondary cracks may eventually continue their propagation in the direction of maximum principle stress. These experimental works were also simulated numerically by a modified higher order displacement discontinuity method and the cracks propagation and cracks coalescence were studied based on Mode I and Mode II stress intensity factors (SIFs). It is concluded that the wing cracks initiation stresses for the specimens change from 11.3 to 14.1 MPain the case of numerical simulations and from 7.3 to 13.8 MPa in the case of experimental works. It is observed that cracks coalescence stresses change from 21.8 to 25.3 MPa and from 19.5 to 21.8 MPa in the numerical and experimental analyses, respectively. Comparing some of the numerical and experimental results with those recently cited in the literature validates the results obtained by the proposed study. Finally, a numerical simulation was accomplished to study the effect of confining pressure on the crack propagation process, showing that the SIFs increase and the crack initiation angles change in this case.展开更多
Crack propagation processes in specially prepared concrete discs and rectangular specimens containing a single cylindrical hole or multiple holes of varying diameters have been studied both experimentally and numerica...Crack propagation processes in specially prepared concrete discs and rectangular specimens containing a single cylindrical hole or multiple holes of varying diameters have been studied both experimentally and numerically. In this research, the cracks coalescence paths in Brazilian disc and rectangular specimens made from rock-like material containing multi-holes are investigated. These concrete specimens are specially prepared from an appropriate mixture of Portland Pozzolana Cement (PPC), fine sands, and water. The pre-holed Brazilian discs and rectangular specimens are experimentally tested under compression. The breakage load in the ring type disc specimens containing an axial hole with varying diameters is measured and the distribution of the induced lateral stress is obtained. The mechanism of cracks propagation in the wall of the ring type specimens is also stud- ied. In the case of multi-hole Brazilian disc and rectangular specimens, the cracks propagation and cracks coalescence are also investigated. These experiments are numerically modeled by a modified higher order displacement discontinuity method. It has been shown that the corresponding experimental and numerical results are in good agreement with each other. The results presented in this research vali date the accuracy and applicability of these crack analyses procedures.展开更多
This article presents a list of insect types preserved in Kunming Natural History Museum of Zoology (KNHMZ). As of March, 2015, 3412 type specimens belonging to 266 species/subspecies of 37 families in 9 orders (Od...This article presents a list of insect types preserved in Kunming Natural History Museum of Zoology (KNHMZ). As of March, 2015, 3412 type specimens belonging to 266 species/subspecies of 37 families in 9 orders (Odonata, Isoptera, Mantodea, Orthoptera, Hemiptera, Coleoptera, Diptera, Hymenoptera and Lepidoptera) are included. Information corrections of some specimens are provided in this article.展开更多
AIM: To determine the distal intramural spread (DIS) margin of rectal cancer.METHODS: Sixty-one p53-positive specimens of rectal cancer were used. After conventional hematoxylin and eosin (H&E) staining, the DI...AIM: To determine the distal intramural spread (DIS) margin of rectal cancer.METHODS: Sixty-one p53-positive specimens of rectal cancer were used. After conventional hematoxylin and eosin (H&E) staining, the DIS margin of rectal cancer in large specimens was examined by immunohistochemistry. The patients were divided into A, B, C, and D groups. After a long-term follow-up, the survival curves of the four groups were estimated using the life table. RESULTS: Fifty-one of the sixty-one cases (83.6%) had DIS. The extent of DIS ranged 0.11-3.5 cm; meanwhile the.mean of DIS measured by H&E staining was 0.13 cm. The significant difference was found between the means (t=5.622, P〈0.0001). Only 1 of 51 patients had DIS greater than 3 cm. The DIS was less than 1.0 cm in most rectal cancer patients. The long-term results indicated that the survival rate of the patients whose DIS was greater than 1.0 cm was lower than that of the patients whose DIS was less than 0.5 cm. CONCLUSION: Rectal cancer patients with DIS greater than 1.0 cm have poor prognosis.展开更多
In order to facilitate herpetological research for all the herpetologists both in and outside of China, we will report all the type specimens of amphibia and reptilia deposited in the Herpetological Museum of Chengdu ...In order to facilitate herpetological research for all the herpetologists both in and outside of China, we will report all the type specimens of amphibia and reptilia deposited in the Herpetological Museum of Chengdu Institute of Biology(CIB), Chinese Academy of Sciences in series. This report focuses on the family Rhacophoridae of Anura in Amphibia, including 13 species. The contents of the report include synonym lists and generic transfer of type species, measurements of type specimens, particularly for those with no previously published measurement data, and chromosomal data for each species.展开更多
In order to facilitate herpetological research for herpetologists in and outside of China,we will report all the type specimens of Amphibia and Reptilia deposited in the Herpetological Museum of the Chengdu Institute ...In order to facilitate herpetological research for herpetologists in and outside of China,we will report all the type specimens of Amphibia and Reptilia deposited in the Herpetological Museum of the Chengdu Institute of Biology(CIB),Chinese Academy of Sciences(CAS) in series. This report focuses on the type specimens of the family Hynobiidae of Urodela in Amphibia,which comprises seven species. Each entry provides the genus name,species name,information of the original description,the catalog number of holotype,sex,type locality,information of allotype(if any) and paratype,number and distribution of deposited specimens,and comments where they are appropriate.展开更多
This paper presents an attempt at the application of catastrophe theory to the stability analysis of J-controlled crack growth in three-point bending specimens. By introducing the solutions of J-integral in the comple...This paper presents an attempt at the application of catastrophe theory to the stability analysis of J-controlled crack growth in three-point bending specimens. By introducing the solutions of J-integral in the completely yielding state for the ideal plastic material, the critical condition of losing stability for the crack propagation in the specimen is obtained, based on the cusp catastrophe theory. The process of the crack growth from geometrical sense is described.展开更多
Icosahedral quasicrystals are the most important and thermodynamically stable in all about 200 kinds of quasicrystals currently observed. Beyond the scope of classical elasticity, apart from a phonon displacement fiel...Icosahedral quasicrystals are the most important and thermodynamically stable in all about 200 kinds of quasicrystals currently observed. Beyond the scope of classical elasticity, apart from a phonon displacement field, there is a phason displacement field in the elasticity of the quasicrystal, which induces an important effect on the mechanical properties of the material and makes an analytical solution difficult to obtain. In this paper, a finite element algorithm for the static elasticity of icosahedral quasicrystals is developed by transforming the elastic boundary value problem of the icosahedral quasicrystals into an equivalent variational problem. Analytical and numerical solutions for an icosahedral A1-Pd-Mn quasicrystal cuboid subjected to a uniaxial tension with different phonon-phason coupling parameters are given to verify the validity of the numerical approach. A comparison between the analytical and numerical solutions of the specimen demonstrates the accuracy and efficiency of the present algorithm. Finally, in order to reveal the fracture behavior of the icosahedral A1-Pd-Mn quasicrystal, a cracked specimen with a finite size of matter is investigated, both with and without phonon-phason coupling. Meanwhile, the geometry factors are calculated, including the stress intensity factor and the crack opening displacement for the finite-size specimen. Computational results reveal the importance of pbonon-phason coupling effect on the icosahedral A1-Pd-Mn quasicrystal. Furthermore, the finite element procedure can be used to solve more complicated boundary value problems.展开更多
Background: Epidermal growth factor receptor(EGFR) mutation is the key predictor of EGFR tyrosine kinase inhibitors(TKIs) efficacy in non-small cell lung cancer(NSCLC). We conducted this study to verify the fea...Background: Epidermal growth factor receptor(EGFR) mutation is the key predictor of EGFR tyrosine kinase inhibitors(TKIs) efficacy in non-small cell lung cancer(NSCLC). We conducted this study to verify the feasibility of EGFR mutation analysis in cytological specimens and investigate the responsiveness to gefitinib treatment in patients carrying EGFR mutations.Methods: A total of 210 cytological specimens were collected for EGFR mutation detection by both direct sequencing and amplification refractory mutation system(ARMS). We analyzed EGFR mutation status by both methods and evaluated the responsiveness to gefitinib treatment in patients harboring EGFR mutations by overall response rate(ORR), disease control rate(DCR) and progression free survival(PFS).Results: Of all patients, EGFR mutation rate was 28.6%(60/210) by direct sequencing and 45.2%(95/210) by ARMS(P〈0.001) respectively. Among the EGFR wild type patients tested by direct sequencing, 26.7% of them were positive by ARMS. For the 72 EGFR mutation positive patients treated with gefitinib, the ORR, DCR and median PFS were 69.4%, 90.2% and 9.3 months respectively. The patients whose EGFR mutation status was negative by direct sequencing but positive by ARMS had lower ORR(48.0% vs. 80.9%, P=0.004) and shorter median PFS(7.4 vs. 10.5 months, P=0.009) as compared with that of EGFR mutation positive patients by both detection methods. Conclusions: Our study verified the feasibility of EGFR analysis in cytological specimens in advanced NSCLC. ARMS is more sensitive than direct sequencing in EGFR mutation detection. EGFR Mutation status tested on cytological samples is applicable for predicting the response to gefitinib. Abundance of EGFR mutations might have an influence on TKIs efficacy.展开更多
For understanding acoustic emission (AE) activity and accumulation of micro-damage inside rock under pure tensile state, the AE signals has been monitored on the test of directly tension on two kinds of marble speci...For understanding acoustic emission (AE) activity and accumulation of micro-damage inside rock under pure tensile state, the AE signals has been monitored on the test of directly tension on two kinds of marble specimens. A tensile constitutive model was proposed with the damage factor calculated by AE energy rate. The tensile strength of marble was discrete obviously and was sensitive to the inside microdefects and grain composition. With increasing of loading, the tensile stress-strain curve obviously showed nonlinear with the tensile tangent modulus decreasing. In repeated loading cycle, the tensile elastic modulus was less than that in the previous loading cycle because of the generation of micro damage during the prior loading. It means the linear weakening occurring in the specimens. The AE activity was corresponding with occurrence of nonlinear deformation. In the initial loading stage which only elastic deformation happened on the specimens, there were few AE events occurred; while when the nonlinear deformation happened with increasing of loading, lots of AE events were generated. The quantity and energy of AE events were proportionally related to the variation of tensile tangent modulus. The Kaiser effect of AE activity could be clearly observed in tensile cycle loading. Based on the theory of damage mechanics, the damage factor was defined by AE energy rate and the tensile damage constitutive model was proposed which only needed two property constants. The theoretical stress-strain curve was well fitted with the curve plotted with tested datum and the two property constants were easily gotten by the laboratory testing.展开更多
A simultaneous experimental and numerical study on crack propagation in the pre-cracked beams specimens(concrete-like materials) is carried out using three-point bending flexural test. The crack propagation and coales...A simultaneous experimental and numerical study on crack propagation in the pre-cracked beams specimens(concrete-like materials) is carried out using three-point bending flexural test. The crack propagation and coalescence paths of internal cracks in side beam specimens are experimentally studied by inserting double internal cracks. The effects of crack positions on the fracturing path in the bridge areas of the double cracked beam specimens are also studied. It has been observed that the breaking of concrete-like cracked beams specimens occurs mainly by the propagation of wing cracks emanating from the tips of the pre-existing cracks in the numerical and experimental analyses, respectively. The same specimens are numerically simulated by an indirect boundary element method(IBEM) known as displacement discontinuity method(DDM) using higher displacement discontinuity. These numerical results are compared with the existing experimental results. This comparison illustrates the higher accuracy of the results obtained by the indirect boundary element method by using only a small number of elements compared with the discrete element method(PFC2D code).展开更多
In China,there are over 180 species of snakes in 57 genera and eight families(excluding the family Viperidae). In the Herpetological Museum of the Chengdu Institute of Biology(CIB),Chinese Academy of Sciences,the snak...In China,there are over 180 species of snakes in 57 genera and eight families(excluding the family Viperidae). In the Herpetological Museum of the Chengdu Institute of Biology(CIB),Chinese Academy of Sciences,the snake type specimens represent 11 species in 10 genera and three families(Xenopeltidae,Xenodermatidae and Colubridae). As a series of reports on the type specimens of Amphibia and Reptilia deposited in the Herpetological Museum of CIB,this paper focuses on the serpent families excluding Viperidae in the collections at this Museum.展开更多
Objective To develop RT-nPCR assays for amplifying partial and complete VP1 genes of human enteroviruses(HEVs)from clinical samples and to contribute to etiological surveillance of HEV-related diseases.Methods A panel...Objective To develop RT-nPCR assays for amplifying partial and complete VP1 genes of human enteroviruses(HEVs)from clinical samples and to contribute to etiological surveillance of HEV-related diseases.Methods A panel of RT-nPCR assays,consisting of published combined primer pairs for VP1 genes of HEV A–C and in-house designed primers for HEV-D,was established in this study.The sensitivity of each RT-nPCR assay was evaluated with serially diluted virus stocks of five serotypes expressed as CCID50 perμL and copies perμL,and the newly established methods were tested in clinical specimens collected in recent years.Results The sensitivity of RT-nPCR assays for amplifying partial VP1 gene of HEVs was 0.1 CCID50 perμL and 10 virus copies perμL,and for the complete VP1 gene was 1 CCID50 perμL and 100 virus copies perμL,using serially-diluted virus stocks of five serotypes.As a proof-of-concept,25 serotypes were identified and complete VP1 sequences of 23 serotypes were obtained by this system among 858 clinical specimens positive for HEVs during the past eight surveillance seasons.Conclusion This RT-nPCR system is capable of amplifying the partial and complete VP1 gene of HEV A–D,providing rapid,sensitive,and reliable options for molecular typing and molecular epidemiology of HEVs in clinical specimens.展开更多
In this paper, a compression-to-tension conversion technique is developed by applying predominant mode I loading test, using a servo-controlled compression system. The technique is applied to thin mortar plate specime...In this paper, a compression-to-tension conversion technique is developed by applying predominant mode I loading test, using a servo-controlled compression system. The technique is applied to thin mortar plate specimens of different widths that include a prefabricated crack on either a single side to facilitate unilateral crack propagation, or prefabricated cracks positioned on both sides asymmetrically with respect to the specimen midpoint to facilitate bilateral crack propagation under direct tensile stress with a loading rate of 0.001 mm/s. The results show that the main pathways of unilateral crack propagation governing specimen failure are fluctuated locally, but present an approximately straight line overall in the absence of pre-existing internal defects. However, the pathways of bilateral crack propagation are relatively complex, although they present similar characteristics. Analysis results suggest that bilateral crack propagation can be basically divided into three stages, i.e. a stage of linear propagation, a stage representing deviation from the other crack, and a stage where one crack approaches either the other crack or approaches the opposite edge of the specimen, and thereby forming a continuous crack through the specimen. In addition, the stressestrain curves of bilateral crack specimens do not vary significantly around the point of peak stress prior to specimen failure, which means that the specimens do not fail instantaneously.展开更多
基金Projects(51925402,52334005,52304094)supported by the National Natural Science Foundation of ChinaProject(20201102004)supported by the Shanxi Science and Technology Major Project,China。
文摘The mechanical properties of residual coal pillars under the influence of upward mining disturbances significantly affect the safety of residual mining activities on working faces.This study conducted low-frequency disturbance dynamic uniaxial compression tests on coal specimens using a self-developed dynamic-static load coupling electro-hydraulic servo system,and studied the strength evolutions,surface deformations,acoustic emission(AE)characteristic parameters,and the failure modes of coal specimens with different static preloading levels were studied.The disturbance damage is positively correlated with the coal specimen static preload level.Specifically,the cumulative AE count rates of the initial accelerated damage stage for the coal specimens with static preloading level of 60%and 70%of the uniaxial compressive strength(UCS)were 2.66 and 3.19 times that of the 50%UCS specimens,respectively.Macroscopically,this behaviour manifested as a decrease in the compressive strength,and the mean strengths of the disturbance-damaged coal specimens with 60%and 70%of UCS static preloading decreased by 8.53%and 9.32%,respectively,compared to those of the specimens under pure static loading.The crack sources,such as the primary fissures,strongly control the dynamic response of the coal specimen.The difference between the dynamic responses of the coal specimens and that of dense rocks is significant.
基金This work was supported by the National High-Technology Research and Development Program of China (863 Program) 2003AA208402.
文摘Objective The causal agent for SARS is considered as a novel coronavirus that has never been described both in human and animals previously. The stability of SARS coronavirus in human specimens and in environments was studied. Methods Using a SARS coronavirus strain CoV-P9, which was isolated from pharyngeal swab of a probable SARS case in Beijing, its stability in mimic human specimens and in mimic environment including surfaces of commonly used materials or in household conditions, as well as its resistances to temperature and UV irradiation were analyzed. A total of 106 TCID50 viruses were placed in each tested condition, and changes of the viral infectivity in samples after treatments were measured by evaluating cytopathic effect (CPE) in cell line Vero-E6 at 48 h after infectionn. Results The results showed that SARS coronavirus in the testing condition could survive in serum, 1:20 diluted sputum and feces for at least 96 h, whereas it could remain alive in urine for at least 72 h with a low level of infectivity. The survival abilities on the surfaces of eight different materials and in water were quite comparable, revealing reduction of infectivity after 72 to 96 h exposure. Viruses stayed stable at 4℃, at room temperature (20℃) and at 37℃ for at least 2 h without remarkable change in the infectious ability in cells, but were converted to be non-infectious after 90-, 60- and 30-min exposure at 56℃, at 67℃ and at 75℃, respectively. Irradiation of UV for 60 min on the virus in culture medium resulted in the destruction of viral infectivity at an undetectable level. Conclusion The survival ability of SARS coronavirus in human specimens and in environments seems to be relatively strong. Heating and UV irradiation can efficiently eliminate the viral infectivity.
文摘AIM: To investigate the prevalence and implications of unusual histopathological findings in appendectomy specimens from patients with suspected acute appendicitis. METHODS: The demographic and histopathological data of 1621 patients (≥ 16 years-old) who underwent appendectomy to treat an initial diagnosis of acute appendicitis between January 1999 and November 2011 were retrospectively assessed. Microscopic findings were used to classify the patients under six categories: appendix vermiformis, phlegmonous appendicitis, gan- grenous appendicitis, perforated appendicitis, supurative appendicitis, and unusual histopathologic findings. The demographic and clinicopathologic characteristics of patients with unusual histopathologic findings were evaluated in detail, and re-analysis of archived resected appendix specimens was carried out. RESULTS: A total of 912 males and 709 females, from16 to 94 years old, were included in the study and comprised 789 cases of suppurative appendicitis, 370 cases of appendix vermiformis, 243 cases of perforated gangrenous appendicitis, 53 cases of flegmaneous appendicitis, 32 cases of gangrenous appendicitis, and 134 (8.3%) cases of unusual histopathological findings. The unusual histopathological findings included fibrous obliteration (n = 62), enterobius vermicularis (n = 31), eosinophilic infiltration (n = 10), mucinous cystadenoma (n = 8), carcinoid tumor (n = 6), granulomatous inflammation (n = 5), adenocarcinoma (n = 4; one of them mucinous), and mucocele (n = 3), adenomatous polyp (n = 1), taenia sup (n = 1), ascaris lumbricoides (n = 1), appendiceal diverticula (n = 1), and B cell non-hodgkin lymphoma (n = 1). None of the 11 patients with subsequent diagnosis of tumor were suspected of cancer prior to the appendectomy. CONCLUSION: Even when the macroscopic appearance of appendectomy specimens is normal, histopathological assessment will allow early diagnosis of many unusual diseases.
基金supported by the China Mega-Project for Infectious Disease(2016ZX10004-101,2016ZX10004-215)Beijing Municipal Science&Technology Commission Project(D151100002115003)Guangzhou Municipal Science&Technology Commission Project(2015B2150820)
文摘Objective To provide a feasible and cost-effective next-generation sequencing (NGS) method for accurate identification of viral pathogens in clinical specimens, because enormous limitations impede the clinical use of common NGS, such as high cost, complicated procedures, tremendous data analysis, and high background noise in clinical samples. Methods Viruses from cell culture materials or clinical specimens were identified following an improved NGS procedure: reduction of background noise by sample preprocessing, viral enrichment by barcoded oligonucleotide (random hexamer or non-ribosomal hexanucleotide) primer-based amplification, fragmentation-free library construction and sequencing of one-tube mixtures, as well as rapid data analysis using an in-house pipeline. Results NGS data demonstrated that both barcoded primer sets were useful to simultaneously capture multiple viral pathogens in cell culture materials or clinical specimens and verified that hexanucleotide primers captured as many viral sequences as hexamers did. Moreover, direct testing of clinical specimens using this improved hexanucleotide primer-based NGS approach provided further detailed genotypes of enteroviruses causing hand, foot, and mouth disease (HFMD) and identified other potential viruses or differentiated misdiagnosis events. Conclusion The improved barcoded oligonucleotide primer-based NGS approach is simplified, time saving, cost effective, and appropriate for direct identification of viral pathogens in clinical practice.
基金supported by the Special Foundation for State Basic Research Program of China(2013FY113300-8)the National Key R&D Program of China(2016YFD0500800)
文摘In recent years,the avian influenza has brought not only serious economic loss to the poultry industry in China but also a serious threat to human health because of the avian influenza virus(AIV) gene recombination and reassortment.Until now,traditional RT-PCR,fluorescence RT-PCR and virus isolation identification have been developed and utilized to detect AIV,but these methods require high-level instruments and experimental conditions,not suitable for the rapid detection in field and farms.In order to develop a rapid,sensitive and practical method to detect and identify AIV subtypes,4 specific primers to the conserved region of AIV M gene were designed and a loop-mediated isothermal amplification(RT-LAMP) method was established.Using this method,the M gene of H1–H16 subtypes of AIV were amplified in 30 min with a water bath and all 16 H subtypes of AIV were able to be visually identified in presence of fluorescein,without cross reaction with other susceptible avian viruses.In addition,the detection limit of the common H1,H5,H7,and H9 AIV subtypes with the RT-LAMP method was 0.1 PFU(plaque-forming unit),which was 10 times more sensitive than that using the routine RT-PCR.Further comparative tests found that the positivity rate of RT-LAMP on detecting clinical samples was 4.18%(14/335) comparing with 3.58%(12/335) from real-time RT-PCR.All these results suggested that the RT-LAMP method can specifically detect and identify AIV with high sensitivity and can be considered as a fast,convenient and practical method for the clinic test and epidemiological investigation of AIV.
基金Supported by The Special Scientific Research Fund for Beijing Health Development,No.2014-2-2182The Scientific Research Project of Beijing You’an Hospital,CCMU,No.YNKTTS20180110Capital Characteristic Fund,No.Z171100001017035
文摘BACKGROUND Pathological manifestations of hepatic tumours are often associated with prognosis. Although surgical specimens(SS) can provide more information,currently, pre-treatment needle core biopsy(NCB) is increasingly showing important value in understanding the nature of liver tumors and even in diagnosis and treatment decisions. However, the concordance of the clinicopathological characteristics and immunohistochemical(IHC) staining between NCB and SS from patients with hepatic tumours were less concerned.AIM To introduce a more accurate method for interpreting the IHC staining results in order to improve the diagnostic value of hepatic malignancy in NCB samples.METHOD A total of 208 patients who underwent both preoperative NCB and surgical resection for hepatocellular carcinoma(HCC) or intrahepatic cholangiocarcinomaRESULTS Morphologically, the presence of compact tumour nests or a cord-like structure in NCB was considered the primary cause of misdiagnosis of HCC from ICC. The kappa statistic showed a moderate agreement in histomorphology(k = 0.504) and histological grade(k = 0.488) between NCB and SS of the tumours. A 4-tier(+++,++, +, and-) scoring scheme that emphasized the focal neoplastic cell immunoreactivity of tumour cells revealed perfect concordance of CK19, GPC3 and HepPar1 between NCB and SS(k = 0.717; k = 0.768; k = 0.633). Furthermore,with the aid of a binary classification derived from the 4-tier score, a high concordance was achieved in interpreting the IHC staining of the three markers between NCB and final SS(k = 0.931; k = 0.907; k = 0.803), increasing the accuracy of NCB diagnosis C(k = 0.987; area under the curve = 0.997, 95%CI: 0.990-1.000; P< 0.001).CONCLUSION These findings imply that reasonable interpretation of IHC results in NCB is vital for improving the accuracy of tumour diagnosis. The simplified binary classification provides an easy and applicable approach.
文摘The mechanism of cracks propagation and cracks coalescence due to compressive loading of the brittle substances containing pre-existing cracks (flaws) was modeled experimentally using specially made rock-like specimens from Portland Pozzolana Cement (PPC). The breakage process of the specimens was studied by inserting single and double flaws with different inclination angles at the center and applying uniaxial compressive stress at both ends of the specimen. The first crack was oriented at 50&#176; from the horizontal direction and kept constant throughout the analysis while the orientation of the second crack was changed. It is experimentally observed that the wing cracks are produced at the first stage of loading and start their propagation toward the direction of uniaxial compressive loading. The secondary cracks may also be produced in form of quasi-coplanar and/or oblique cracks in a stable manner. The secondary cracks may eventually continue their propagation in the direction of maximum principle stress. These experimental works were also simulated numerically by a modified higher order displacement discontinuity method and the cracks propagation and cracks coalescence were studied based on Mode I and Mode II stress intensity factors (SIFs). It is concluded that the wing cracks initiation stresses for the specimens change from 11.3 to 14.1 MPain the case of numerical simulations and from 7.3 to 13.8 MPa in the case of experimental works. It is observed that cracks coalescence stresses change from 21.8 to 25.3 MPa and from 19.5 to 21.8 MPa in the numerical and experimental analyses, respectively. Comparing some of the numerical and experimental results with those recently cited in the literature validates the results obtained by the proposed study. Finally, a numerical simulation was accomplished to study the effect of confining pressure on the crack propagation process, showing that the SIFs increase and the crack initiation angles change in this case.
基金sponsored by Iran’s National Elites Foundation (INEF)
文摘Crack propagation processes in specially prepared concrete discs and rectangular specimens containing a single cylindrical hole or multiple holes of varying diameters have been studied both experimentally and numerically. In this research, the cracks coalescence paths in Brazilian disc and rectangular specimens made from rock-like material containing multi-holes are investigated. These concrete specimens are specially prepared from an appropriate mixture of Portland Pozzolana Cement (PPC), fine sands, and water. The pre-holed Brazilian discs and rectangular specimens are experimentally tested under compression. The breakage load in the ring type disc specimens containing an axial hole with varying diameters is measured and the distribution of the induced lateral stress is obtained. The mechanism of cracks propagation in the wall of the ring type specimens is also stud- ied. In the case of multi-hole Brazilian disc and rectangular specimens, the cracks propagation and cracks coalescence are also investigated. These experiments are numerically modeled by a modified higher order displacement discontinuity method. It has been shown that the corresponding experimental and numerical results are in good agreement with each other. The results presented in this research vali date the accuracy and applicability of these crack analyses procedures.
基金supported by the key project of Science-technology basic condition platform from The Ministry of Science and Technology of the People's Republic of China(2005DKA21402)
文摘This article presents a list of insect types preserved in Kunming Natural History Museum of Zoology (KNHMZ). As of March, 2015, 3412 type specimens belonging to 266 species/subspecies of 37 families in 9 orders (Odonata, Isoptera, Mantodea, Orthoptera, Hemiptera, Coleoptera, Diptera, Hymenoptera and Lepidoptera) are included. Information corrections of some specimens are provided in this article.
文摘AIM: To determine the distal intramural spread (DIS) margin of rectal cancer.METHODS: Sixty-one p53-positive specimens of rectal cancer were used. After conventional hematoxylin and eosin (H&E) staining, the DIS margin of rectal cancer in large specimens was examined by immunohistochemistry. The patients were divided into A, B, C, and D groups. After a long-term follow-up, the survival curves of the four groups were estimated using the life table. RESULTS: Fifty-one of the sixty-one cases (83.6%) had DIS. The extent of DIS ranged 0.11-3.5 cm; meanwhile the.mean of DIS measured by H&E staining was 0.13 cm. The significant difference was found between the means (t=5.622, P〈0.0001). Only 1 of 51 patients had DIS greater than 3 cm. The DIS was less than 1.0 cm in most rectal cancer patients. The long-term results indicated that the survival rate of the patients whose DIS was greater than 1.0 cm was lower than that of the patients whose DIS was less than 0.5 cm. CONCLUSION: Rectal cancer patients with DIS greater than 1.0 cm have poor prognosis.
基金supported by the Project of the Postdoctoral Science Foundation of China(No.20100471689)the‘Xibuzhiguang’Project of the Chinese Academy of Sciences(No.Y1C3011)+2 种基金the‘Lingyuqianyan’Project of the Chinese Academy of Sciences(No.Y1B3011)the National Natural Science Foundation of China(31101618)the Project of the Chinese Academy of Sciences(KSCX2-EW-Q-6 and KSCX2-EW-J-22)
文摘In order to facilitate herpetological research for all the herpetologists both in and outside of China, we will report all the type specimens of amphibia and reptilia deposited in the Herpetological Museum of Chengdu Institute of Biology(CIB), Chinese Academy of Sciences in series. This report focuses on the family Rhacophoridae of Anura in Amphibia, including 13 species. The contents of the report include synonym lists and generic transfer of type species, measurements of type specimens, particularly for those with no previously published measurement data, and chromosomal data for each species.
基金supported by the grant of the National Natural Science Foundation of China (NSFC) (30870287) to Xiaomao ZENGthe grants of NSFC (30900138)Henan University of Science and Technology Foundation (09001367) to Jianli XIONG
文摘In order to facilitate herpetological research for herpetologists in and outside of China,we will report all the type specimens of Amphibia and Reptilia deposited in the Herpetological Museum of the Chengdu Institute of Biology(CIB),Chinese Academy of Sciences(CAS) in series. This report focuses on the type specimens of the family Hynobiidae of Urodela in Amphibia,which comprises seven species. Each entry provides the genus name,species name,information of the original description,the catalog number of holotype,sex,type locality,information of allotype(if any) and paratype,number and distribution of deposited specimens,and comments where they are appropriate.
文摘This paper presents an attempt at the application of catastrophe theory to the stability analysis of J-controlled crack growth in three-point bending specimens. By introducing the solutions of J-integral in the completely yielding state for the ideal plastic material, the critical condition of losing stability for the crack propagation in the specimen is obtained, based on the cusp catastrophe theory. The process of the crack growth from geometrical sense is described.
基金Project supported by the National Natural Science Foundation of China(Grant No.11172319)the Scientific Fund of Chinese Universities(Grant Nos.2011JS046 and 2013BH008)+1 种基金the Opening Fund of State Key Laboratory of Nonlinear Mechanics,Program for New Century Excellent Talents in University,China(Grant No.NCET-13-0552)the National Science Foundation for Post-doctoral Scientists of China(Grant No.2013M541086)
文摘Icosahedral quasicrystals are the most important and thermodynamically stable in all about 200 kinds of quasicrystals currently observed. Beyond the scope of classical elasticity, apart from a phonon displacement field, there is a phason displacement field in the elasticity of the quasicrystal, which induces an important effect on the mechanical properties of the material and makes an analytical solution difficult to obtain. In this paper, a finite element algorithm for the static elasticity of icosahedral quasicrystals is developed by transforming the elastic boundary value problem of the icosahedral quasicrystals into an equivalent variational problem. Analytical and numerical solutions for an icosahedral A1-Pd-Mn quasicrystal cuboid subjected to a uniaxial tension with different phonon-phason coupling parameters are given to verify the validity of the numerical approach. A comparison between the analytical and numerical solutions of the specimen demonstrates the accuracy and efficiency of the present algorithm. Finally, in order to reveal the fracture behavior of the icosahedral A1-Pd-Mn quasicrystal, a cracked specimen with a finite size of matter is investigated, both with and without phonon-phason coupling. Meanwhile, the geometry factors are calculated, including the stress intensity factor and the crack opening displacement for the finite-size specimen. Computational results reveal the importance of pbonon-phason coupling effect on the icosahedral A1-Pd-Mn quasicrystal. Furthermore, the finite element procedure can be used to solve more complicated boundary value problems.
文摘Background: Epidermal growth factor receptor(EGFR) mutation is the key predictor of EGFR tyrosine kinase inhibitors(TKIs) efficacy in non-small cell lung cancer(NSCLC). We conducted this study to verify the feasibility of EGFR mutation analysis in cytological specimens and investigate the responsiveness to gefitinib treatment in patients carrying EGFR mutations.Methods: A total of 210 cytological specimens were collected for EGFR mutation detection by both direct sequencing and amplification refractory mutation system(ARMS). We analyzed EGFR mutation status by both methods and evaluated the responsiveness to gefitinib treatment in patients harboring EGFR mutations by overall response rate(ORR), disease control rate(DCR) and progression free survival(PFS).Results: Of all patients, EGFR mutation rate was 28.6%(60/210) by direct sequencing and 45.2%(95/210) by ARMS(P〈0.001) respectively. Among the EGFR wild type patients tested by direct sequencing, 26.7% of them were positive by ARMS. For the 72 EGFR mutation positive patients treated with gefitinib, the ORR, DCR and median PFS were 69.4%, 90.2% and 9.3 months respectively. The patients whose EGFR mutation status was negative by direct sequencing but positive by ARMS had lower ORR(48.0% vs. 80.9%, P=0.004) and shorter median PFS(7.4 vs. 10.5 months, P=0.009) as compared with that of EGFR mutation positive patients by both detection methods. Conclusions: Our study verified the feasibility of EGFR analysis in cytological specimens in advanced NSCLC. ARMS is more sensitive than direct sequencing in EGFR mutation detection. EGFR Mutation status tested on cytological samples is applicable for predicting the response to gefitinib. Abundance of EGFR mutations might have an influence on TKIs efficacy.
文摘For understanding acoustic emission (AE) activity and accumulation of micro-damage inside rock under pure tensile state, the AE signals has been monitored on the test of directly tension on two kinds of marble specimens. A tensile constitutive model was proposed with the damage factor calculated by AE energy rate. The tensile strength of marble was discrete obviously and was sensitive to the inside microdefects and grain composition. With increasing of loading, the tensile stress-strain curve obviously showed nonlinear with the tensile tangent modulus decreasing. In repeated loading cycle, the tensile elastic modulus was less than that in the previous loading cycle because of the generation of micro damage during the prior loading. It means the linear weakening occurring in the specimens. The AE activity was corresponding with occurrence of nonlinear deformation. In the initial loading stage which only elastic deformation happened on the specimens, there were few AE events occurred; while when the nonlinear deformation happened with increasing of loading, lots of AE events were generated. The quantity and energy of AE events were proportionally related to the variation of tensile tangent modulus. The Kaiser effect of AE activity could be clearly observed in tensile cycle loading. Based on the theory of damage mechanics, the damage factor was defined by AE energy rate and the tensile damage constitutive model was proposed which only needed two property constants. The theoretical stress-strain curve was well fitted with the curve plotted with tested datum and the two property constants were easily gotten by the laboratory testing.
文摘A simultaneous experimental and numerical study on crack propagation in the pre-cracked beams specimens(concrete-like materials) is carried out using three-point bending flexural test. The crack propagation and coalescence paths of internal cracks in side beam specimens are experimentally studied by inserting double internal cracks. The effects of crack positions on the fracturing path in the bridge areas of the double cracked beam specimens are also studied. It has been observed that the breaking of concrete-like cracked beams specimens occurs mainly by the propagation of wing cracks emanating from the tips of the pre-existing cracks in the numerical and experimental analyses, respectively. The same specimens are numerically simulated by an indirect boundary element method(IBEM) known as displacement discontinuity method(DDM) using higher displacement discontinuity. These numerical results are compared with the existing experimental results. This comparison illustrates the higher accuracy of the results obtained by the indirect boundary element method by using only a small number of elements compared with the discrete element method(PFC2D code).
基金funded by the National Natural Science Foundation of China (NSFC 31071892)the Program for New Century Excellent Talents in University, the Ministry of Education of China (NCET-08-0908)the Sichuan Foundation for Youth Scientists and Technologists (08ZQ06-006)
文摘In China,there are over 180 species of snakes in 57 genera and eight families(excluding the family Viperidae). In the Herpetological Museum of the Chengdu Institute of Biology(CIB),Chinese Academy of Sciences,the snake type specimens represent 11 species in 10 genera and three families(Xenopeltidae,Xenodermatidae and Colubridae). As a series of reports on the type specimens of Amphibia and Reptilia deposited in the Herpetological Museum of CIB,this paper focuses on the serpent families excluding Viperidae in the collections at this Museum.
基金National Science and Technology Major Projects[No.2017ZX10104001 and No.2017ZX10103008]Fujian Provincial Natural Science Foundation[No.2016J01350]。
文摘Objective To develop RT-nPCR assays for amplifying partial and complete VP1 genes of human enteroviruses(HEVs)from clinical samples and to contribute to etiological surveillance of HEV-related diseases.Methods A panel of RT-nPCR assays,consisting of published combined primer pairs for VP1 genes of HEV A–C and in-house designed primers for HEV-D,was established in this study.The sensitivity of each RT-nPCR assay was evaluated with serially diluted virus stocks of five serotypes expressed as CCID50 perμL and copies perμL,and the newly established methods were tested in clinical specimens collected in recent years.Results The sensitivity of RT-nPCR assays for amplifying partial VP1 gene of HEVs was 0.1 CCID50 perμL and 10 virus copies perμL,and for the complete VP1 gene was 1 CCID50 perμL and 100 virus copies perμL,using serially-diluted virus stocks of five serotypes.As a proof-of-concept,25 serotypes were identified and complete VP1 sequences of 23 serotypes were obtained by this system among 858 clinical specimens positive for HEVs during the past eight surveillance seasons.Conclusion This RT-nPCR system is capable of amplifying the partial and complete VP1 gene of HEV A–D,providing rapid,sensitive,and reliable options for molecular typing and molecular epidemiology of HEVs in clinical specimens.
基金support provided by the Strategic Program of Chinese Academy of Sciences (Grant No. XDB10030400)the Hundred Talent Program of Chinese Academy of Sciences (Grant No. Y323081C01)
文摘In this paper, a compression-to-tension conversion technique is developed by applying predominant mode I loading test, using a servo-controlled compression system. The technique is applied to thin mortar plate specimens of different widths that include a prefabricated crack on either a single side to facilitate unilateral crack propagation, or prefabricated cracks positioned on both sides asymmetrically with respect to the specimen midpoint to facilitate bilateral crack propagation under direct tensile stress with a loading rate of 0.001 mm/s. The results show that the main pathways of unilateral crack propagation governing specimen failure are fluctuated locally, but present an approximately straight line overall in the absence of pre-existing internal defects. However, the pathways of bilateral crack propagation are relatively complex, although they present similar characteristics. Analysis results suggest that bilateral crack propagation can be basically divided into three stages, i.e. a stage of linear propagation, a stage representing deviation from the other crack, and a stage where one crack approaches either the other crack or approaches the opposite edge of the specimen, and thereby forming a continuous crack through the specimen. In addition, the stressestrain curves of bilateral crack specimens do not vary significantly around the point of peak stress prior to specimen failure, which means that the specimens do not fail instantaneously.