Since stack effect that occurs in high-rise buildings has an effect on the indoor environment of the buildings, energy loss and smoke control in case of a fire, there is a need to conduct research on this. For an anal...Since stack effect that occurs in high-rise buildings has an effect on the indoor environment of the buildings, energy loss and smoke control in case of a fire, there is a need to conduct research on this. For an analysis of the stack effect, analysis methods on the leakage flow through gap of interior door shall be formulated. Until now, studies related to the gap leakage flow in buildings have mainly analyzed flow field and pressure in the buildings one-dimensionally using pressure difference-leakage flowrate relations of Orifice Equation and a network numerical analysis algorithm that as- sumes each compartment in the buildings as a single point. In this study, the Momentum Loss Model which enables pressure drop to be proportional to the flow velocity through the gap of door in computational domain of 3-dimensional numerical analysis was proposed to reflect the gap flow phenomenon effectively in 3-dimensional numerical analysis. Using the proposed model, 3-dimensional numerical analysis of the stack effect on the stairs in buildings was performed, and the effects of separation door and lobby between stair and accommodation on the stack effect were investigated.展开更多
Infectious disease departments in hospitals require pressure gradient to create unidirectional airflow to prevent the spread of contaminants,typically by creating active air infiltration through the difference between...Infectious disease departments in hospitals require pressure gradient to create unidirectional airflow to prevent the spread of contaminants,typically by creating active air infiltration through the difference between supply and exhaust air volumes.The door gap is the channel of air flow between rooms,so its height has an important influence on the pressure difference and infiltration air volume of the room.There is still a lack of research on setting reasonable ventilation strategies according to the different heights of door gaps at different positions in the building.In this study,model of a set of isolation wards was established and analyzed using the multi-zone simulation software CONTAM,and the ventilation strategies with different heights of door gaps were applied to the actual infection diseases department.The results show that in a building with ventilation system divided by functional area,the difference in the height of the door gaps requires different active infiltration air volumes.Pressure fluctuations in the medical and patient corridors are greater than in other rooms.The significance of this study is to understand the active infiltration of air to guide the design and operation of ventilation systems in infectious disease hospitals or building remodeled to isolate close contacts of COVID-19 patients.It is also instructive for the design of pressure gradients in clean workshops,biological laboratories,and other similar buildings.展开更多
文摘Since stack effect that occurs in high-rise buildings has an effect on the indoor environment of the buildings, energy loss and smoke control in case of a fire, there is a need to conduct research on this. For an analysis of the stack effect, analysis methods on the leakage flow through gap of interior door shall be formulated. Until now, studies related to the gap leakage flow in buildings have mainly analyzed flow field and pressure in the buildings one-dimensionally using pressure difference-leakage flowrate relations of Orifice Equation and a network numerical analysis algorithm that as- sumes each compartment in the buildings as a single point. In this study, the Momentum Loss Model which enables pressure drop to be proportional to the flow velocity through the gap of door in computational domain of 3-dimensional numerical analysis was proposed to reflect the gap flow phenomenon effectively in 3-dimensional numerical analysis. Using the proposed model, 3-dimensional numerical analysis of the stack effect on the stairs in buildings was performed, and the effects of separation door and lobby between stair and accommodation on the stack effect were investigated.
文摘Infectious disease departments in hospitals require pressure gradient to create unidirectional airflow to prevent the spread of contaminants,typically by creating active air infiltration through the difference between supply and exhaust air volumes.The door gap is the channel of air flow between rooms,so its height has an important influence on the pressure difference and infiltration air volume of the room.There is still a lack of research on setting reasonable ventilation strategies according to the different heights of door gaps at different positions in the building.In this study,model of a set of isolation wards was established and analyzed using the multi-zone simulation software CONTAM,and the ventilation strategies with different heights of door gaps were applied to the actual infection diseases department.The results show that in a building with ventilation system divided by functional area,the difference in the height of the door gaps requires different active infiltration air volumes.Pressure fluctuations in the medical and patient corridors are greater than in other rooms.The significance of this study is to understand the active infiltration of air to guide the design and operation of ventilation systems in infectious disease hospitals or building remodeled to isolate close contacts of COVID-19 patients.It is also instructive for the design of pressure gradients in clean workshops,biological laboratories,and other similar buildings.