Determination of Timer Error and Evaluation of Its Effect on Dose for OB6, GammaBeam X200 and X-Ray Irradiators at the Secondary Standard Dosimetry Laboratory in Nigeria
1
作者 Olumide Olaife Akerele Samuel Mofolorunsho Oyeyemi +3 位作者 David Olakanmi Olaniyi Francis Adole Agada Bamidele Musbau Adeniran Latifat Ronke Owoade 《World Journal of Nuclear Science and Technology》 CAS 2024年第2期118-130,共13页
Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irra... Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator. 展开更多
关键词 Timer Error Irradiation SSDL Irradiators dose Accuracy
下载PDF
Evaluation of Air-Kerma and Absorbed Dose to Water for External Radiotherapy Beam Using Ionization Chamber
2
作者 Collins Omondi Margaret Chege Samson Omondi 《Open Journal of Radiology》 2024年第3期113-124,共12页
Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement... Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement using ionization chamber is a prerequisite for absorbed dose determination for external beam radiotherapy. Calibration coefficient is expressed in terms of air kerma and absorbed dose to water traceable to Secondary Standards Dosimetry Laboratory. The objective of this work was to evaluate the level of accuracy of ionization chamber used for clinical radiotherapy beam determination. Measurement and accuracy determination were carried out according to IAEA TRS 398 protocol. Clinical farmers type ionization chamber measurement and National Reference standard from Secondary Standards Dosimetry Laboratory were both exposed to cobalt-60 beam and measurement results compared under the same environmental conditions. The accuracy level between National Reference Standard and clinical radiotherapy standard was found to be −1.92% and −2.02% for air kerma and absorbed dose to water respectively. To minimize the effect of error and maximize therapeutic dose during treatment in order to achieve required clinical outcome, calibration factor was determined for air kerma (Nk) as 49.7 mGy/nC and absorbed dose to water ND, as 52.9 mGy/nC. The study established that radiotherapy beam measurement chain is prone to errors. Hence there is a need to independently verify the accuracy of radiation dose to ensure precision of dose delivery. The errors must be accounted for during clinical planning by factoring in calibration factor to minimize the systematic errors during treatment, and thereby providing enough room to achieve ±5% dose delivery to tumor target as recommended by ICRU. 展开更多
关键词 Absorbed dose to Water Air Kerma Co-60 Source Calibration SSDL Radiotherapy Beam METROLOGY Accuracy and Accuracy
下载PDF
Evaluation of Dosimetric Impact of Uncertainty of Measurement in Estimating External Radiotherapy Dose
3
作者 Collins Omondi Margaret Chege Samson Omondi 《Open Journal of Applied Sciences》 2024年第8期1985-1995,共11页
Cancer is a major societal public health and economic problem, responsible for one in every six deaths. Radiotherapy is the main technique of treatment for more than half of cancer patients. To achieve a successful ou... Cancer is a major societal public health and economic problem, responsible for one in every six deaths. Radiotherapy is the main technique of treatment for more than half of cancer patients. To achieve a successful outcome, the radiation dose must be delivered accurately and precisely to the tumor, within ± 5% accuracy. Smaller uncertainties are required for better treatment outcome. The objective of the study is to investigate the uncertainty of measurement of external radiotherapy beam using a standard ionization chamber under reference conditions. Clinical farmers type ionization chamber measurement was compared against the National Reference standard, by exposing it in a beam 60Co gamma source. The measurement set up was carried out according to IAEA TRS 498 protocol and uncertainty of measurement evaluated according to GUM TEDDOC-1585. Evaluation and analysis were done for the identified subjects of uncertainty contributors. The expanded uncertainty associated with 56 mGy/nC ND,W was found to be 0.9% corresponding to a confidence level of approximately 95% with a coverage factor of k = 2. The study established the impact of dosimetry uncertainty of measurement in estimating external radiotherapy dose. The investigation established that the largest contributor of uncertainty is the stability of the ionization chamber at 36%, followed by temperature at 22% and positioning of the chamber in the beam at 8%. The effect of pressure, electrometer, resolution, and reproducibility were found to be minimal to the overall uncertainty. The study indicate that there is no flawless measurement, as there are many prospective sources of variation. Measurement results have component of unreliability and should be regarded as best estimates of the true value. . 展开更多
关键词 Absorbed dose to Water RADIOTHERAPY Uncertainty of Measurement Secondary Standards Dosimetry Laboratory Ionizing Chamber
下载PDF
Spectral purification improves monitoring accuracy of the comprehensive growth evaluation index for film-mulched winter wheat 被引量:1
4
作者 Zhikai Cheng Xiaobo Gu +5 位作者 Yadan Du Zhihui Zhou Wenlong Li Xiaobo Zheng Wenjing Cai Tian Chang 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2024年第5期1523-1540,共18页
In order to further improve the utility of unmanned aerial vehicle(UAV)remote-sensing for quickly and accurately monitoring the growth of winter wheat under film mulching, this study examined the treatments of ridge m... In order to further improve the utility of unmanned aerial vehicle(UAV)remote-sensing for quickly and accurately monitoring the growth of winter wheat under film mulching, this study examined the treatments of ridge mulching,ridge–furrow full mulching, and flat cropping full mulching in winter wheat.Based on the fuzzy comprehensive evaluation (FCE) method, four agronomic parameters (leaf area index, above-ground biomass, plant height, and leaf chlorophyll content) were used to calculate the comprehensive growth evaluation index (CGEI) of the winter wheat, and 14 visible and near-infrared spectral indices were calculated using spectral purification technology to process the remote-sensing image data of winter wheat obtained by multispectral UAV.Four machine learning algorithms, partial least squares, support vector machines, random forests, and artificial neural network networks(ANN), were used to build the winter wheat growth monitoring model under film mulching, and accuracy evaluation and mapping of the spatial and temporal distribution of winter wheat growth status were carried out.The results showed that the CGEI of winter wheat under film mulching constructed using the FCE method could objectively and comprehensively evaluate the crop growth status.The accuracy of remote-sensing inversion of the CGEI based on the ANN model was higher than for the individual agronomic parameters, with a coefficient of determination of 0.75,a root mean square error of 8.40, and a mean absolute value error of 6.53.Spectral purification could eliminate the interference of background effects caused by mulching and soil, effectively improving the accuracy of the remotesensing inversion of winter wheat under film mulching, with the best inversion effect achieved on the ridge–furrow full mulching area after spectral purification.The results of this study provide a theoretical reference for the use of UAV remote-sensing to monitor the growth status of winter wheat with film mulching. 展开更多
关键词 mulched winter wheat machine learning fuzzy comprehensive evaluation comprehensive growth evaluation index unmanned aerial vehicle
下载PDF
Landslide hazard susceptibility evaluation based on SBAS-InSAR technology and SSA-BP neural network algorithm:A case study of Baihetan Reservoir Area 被引量:1
5
作者 GUO Junqi XI Wenfei +4 位作者 YANG Zhiquan SHI Zhengtao HUANG Guangcai YANG Zhengrong YANG Dongqing 《Journal of Mountain Science》 SCIE CSCD 2024年第3期952-972,共21页
Landslide hazard susceptibility evaluation takes on critical significance in early warning and disaster prevention and reduction.In order to solve the problems of poor effectiveness of landslide data and complex calcu... Landslide hazard susceptibility evaluation takes on critical significance in early warning and disaster prevention and reduction.In order to solve the problems of poor effectiveness of landslide data and complex calculation of weights for multiple evaluation factors in the existing landslide susceptibility evaluation models,in this study,a method of landslide hazard susceptibility evaluation is proposed by combining SBAS-InSAR(Small Baseline Subsets-Interferometric Synthetic Aperture Radar)and SSA-BP(Sparrow Search Algorithm-Back Propagation)neural network algorithm.The SBAS-InSAR technology is adopted to identify potential landslide hazards in the study area,update the cataloging data of landslide hazards,and 11 evaluation factors are chosen for constructing the SSA-BP model for training and validation.Baihetan Reservoir area is selected as a case study for validation.As indicated by the results,the application of SBAS-InSAR technology,combined with both ascending and descending orbit data,effectively addresses the incomplete identification of landslide hazards caused by geometric distortion of single orbit SAR data(e.g.,shadow,overlay,and perspective contraction)in deep canyon areas,thereby enabling the acquisition of up-to-date landslide hazard data.Moreover,in comparison to the conventional BP(Back Propagation)algorithm,the accuracy of the model constructed by the SSA-BP algorithm exhibits a significant increase,with mean squared error and mean absolute error reduced by 0.0142 and 0.0607,respectively.Additionally,during the process of susceptibility evaluation,the SSA-BP model effectively circumvents the issue of considerable manual interventions in calculating the weight of evaluation factors.The area under the curve of this model reaches 0.909,surpassing BP(0.835),random forest(0.792),and the information value method(0.699).The risk of landslide occurrence in the Baihetan Reservoir area is positively correlated with slope,surface temperature,and deformation rate,while it is negatively correlated with fault distance and normalized difference vegetation index.Geological lithology exerts minimal influence on the occurrence of landslides,with the risk being low in forest land and high in grassland.The method proposed in this study provides a useful reference for disaster prevention and mitigation departments to perform landslide hazard susceptibility evaluations in deep canyon areas under complex geological conditions. 展开更多
关键词 Baihetan SBAS-InSAR SSA-BP Landslide hazard susceptibility evaluation
下载PDF
Evaluation of Entrance Skin Dose from Paediatric Diagnostic X-Ray Examination
6
作者 Moromoke Oluwayemisi Adelayi Oladele Samuel Ajayi 《Open Journal of Radiology》 2023年第1期26-33,共8页
As children are prone to be more radiosensitive than adults, it is imperative to assess the Entrance Skin Doses (ESDs) for patients being examined by X-rays, in order to ensure the optimization of dose while consideri... As children are prone to be more radiosensitive than adults, it is imperative to assess the Entrance Skin Doses (ESDs) for patients being examined by X-rays, in order to ensure the optimization of dose while considering a number of other fickles. The ESD received by 50 paediatrics (aged 1-13 years) undergoing 8 types of X-ray examinations were measured at Federal Teaching Hospital, Ido-Ekiti, Ekiti, Nigeria, within a period of February 2019 to March 2020 using thermoluminescent dosimeters. The mean ± SD of ESDs were 0.85 ± 0.32, 2.04 ± 0.75, 0.60 ± 0.07, 0.62 ± 0.22, 0.57 ± 0.24, 1.75 ± 0.76, 0.93 ± 0.31 and 0.63 ± 0.06 mGy for Chest, Skull, Hand, Forearm, Knee, Abdomen, Leg and Feet, respectively. The mean ESDs were found to be within the recommended reference dose in all examinations, except for the Chest examination which was higher. The data obtained in this study will serve as existing data in Nigeria for future research works, as it would assist in optimizing dose to patients, especially the paediatrics. 展开更多
关键词 Entrance Skin dose PAEDIATRICS X-Rays
下载PDF
Comparative evaluation of commercial Douchi by different molds:biogenic amines,non-volatile and volatile compounds 被引量:1
7
作者 Aijun Li Gang Yang +4 位作者 Zhirong Wang Shenglan Liao Muying Du Jun Song Jianquan Kan 《Food Science and Human Wellness》 SCIE CSCD 2024年第1期434-443,共10页
To provide new insights into the development and utilization of Douchi artificial starters,three common strains(Aspergillus oryzae,Mucor racemosus,and Rhizopus oligosporus)were used to study their influence on the fer... To provide new insights into the development and utilization of Douchi artificial starters,three common strains(Aspergillus oryzae,Mucor racemosus,and Rhizopus oligosporus)were used to study their influence on the fermentation of Douchi.The results showed that the biogenic amine contents of the three types of Douchi were all within the safe range and far lower than those of traditional fermented Douchi.Aspergillus-type Douchi produced more free amino acids than the other two types of Douchi,and its umami taste was more prominent in sensory evaluation(P<0.01),while Mucor-type and Rhizopus-type Douchi produced more esters and pyrazines,making the aroma,sauce,and Douchi flavor more abundant.According to the Pearson and PLS analyses results,sweetness was significantly negatively correlated with phenylalanine,cysteine,and acetic acid(P<0.05),bitterness was significantly negatively correlated with malic acid(P<0.05),the sour taste was significantly positively correlated with citric acid and most free amino acids(P<0.05),while astringency was significantly negatively correlated with glucose(P<0.001).Thirteen volatile compounds such as furfuryl alcohol,phenethyl alcohol,and benzaldehyde caused the flavor difference of three types of Douchi.This study provides theoretical basis for the selection of starting strains for commercial Douchi production. 展开更多
关键词 DOUCHI Starting strains Non-volatile compounds Volatile compounds Sensory evaluation
下载PDF
Identification and evaluation of shale oil micromigration and its petroleum geological significance 被引量:2
8
作者 HU Tao JIANG Fujie +10 位作者 PANG Xiongqi LIU Yuan WU Guanyun ZHOU Kuo XIAO Huiyi JIANG Zhenxue LI Maowen JIANG Shu HUANG Liliang CHEN Dongxia MENG Qingyang 《Petroleum Exploration and Development》 SCIE 2024年第1期127-140,共14页
Taking the Lower Permian Fengcheng Formation shale in Mahu Sag of Junggar Basin,NW China,as an example,core observation,test analysis,geological analysis and numerical simulation were applied to identify the shale oil... Taking the Lower Permian Fengcheng Formation shale in Mahu Sag of Junggar Basin,NW China,as an example,core observation,test analysis,geological analysis and numerical simulation were applied to identify the shale oil micro-migration phenomenon.The hydrocarbon micro-migration in shale oil was quantitatively evaluated and verified by a self-created hydrocarbon expulsion potential method,and the petroleum geological significance of shale oil micro-migration evaluation was determined.Results show that significant micro-migration can be recognized between the organic-rich lamina and organic-poor lamina.The organic-rich lamina has strong hydrocarbon generation ability.The heavy components of hydrocarbon preferentially retained by kerogen swelling or adsorption,while the light components of hydrocarbon were migrated and accumulated to the interbedded felsic or carbonate organic-poor laminae as free oil.About 69% of the Fengcheng Formation shale samples in Well MY1 exhibit hydrocarbon charging phenomenon,while 31% of those exhibit hydrocarbon expulsion phenomenon.The reliability of the micro-migration evaluation results was verified by combining the group components based on the geochromatography effect,two-dimension nuclear magnetic resonance analysis,and the geochemical behavior of inorganic manganese elements in the process of hydrocarbon migration.Micro-migration is a bridge connecting the hydrocarbon accumulation elements in shale formations,which reflects the whole process of shale oil generation,expulsion and accumulation,and controls the content and composition of shale oil.The identification and evaluation of shale oil micro-migration will provide new perspectives for dynamically differential enrichment mechanism of shale oil and establishing a“multi-peak model in oil generation”of shale. 展开更多
关键词 shale oil micro-migration identification micro-migration evaluation Junggar Basin Mahu Sag Lower Permian Fengcheng Formation hydrocarbon expulsion potential method
下载PDF
Method for evaluation of geological strength index of carbonate cliff rocks:Coupled hyperspectral-digital borehole image technique 被引量:1
9
作者 Haiqing Yang Guizhong Huang +3 位作者 Chiwei Chen Yong Yang Qi Wang Xionghui Dai 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第10期4204-4215,共12页
The deterioration of unstable rock mass raised interest in evaluating rock mass quality.However,the traditional evaluation method for the geological strength index(GSI)primarily emphasizes the rock structure and chara... The deterioration of unstable rock mass raised interest in evaluating rock mass quality.However,the traditional evaluation method for the geological strength index(GSI)primarily emphasizes the rock structure and characteristics of discontinuities.It ignores the influence of mineral composition and shows a deficiency in assessing the integrity coefficient.In this context,hyperspectral imaging and digital panoramic borehole camera technologies are applied to analyze the mineral content and integrity of rock mass.Based on the carbonate mineral content and fissure area ratio,the strength reduction factor and integrity coefficient are calculated to improve the GSI evaluation method.According to the results of mineral classification and fissure identification,the strength reduction factor and integrity coefficient increase with the depth of rock mass.The rock mass GSI calculated by the improved method is mainly concentrated between 40 and 60,which is close to the calculation results of the traditional method.The GSI error rates obtained by the two methods are mostly less than 10%,indicating the rationality of the hyperspectral-digital borehole image coupled evaluation method.Moreover,the sensitivity of the fissure area ratio(Sr)to GSI is greater than that of the strength reduction factor(a),which means the proposed GSI is suitable for rocks with significant fissure development.The improved method reduces the influence of subjective factors and provides a reliable index for the deterioration evaluation of rock mass. 展开更多
关键词 Hyperspectral image Digital panoramic borehole image Geological strength index Carbonate rock mass Quantitative evaluation
下载PDF
Systematic analysis and modeling of the FLASH sparing effect as a function of dose and dose rate
10
作者 Qi-Bin Fu Yan Zhang +3 位作者 Yu-Cheng Wang Tu-Chen Huang Hong-Yu Zhu Xiao-Wu Deng 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期51-58,共8页
Ultrahigh-dose-rate radiotherapy(FLASH-RT)is a revolutionary radiotherapy technology that can spare normal tissues without compromising tumor control.Although qualitative experimental results have been reported,quanti... Ultrahigh-dose-rate radiotherapy(FLASH-RT)is a revolutionary radiotherapy technology that can spare normal tissues without compromising tumor control.Although qualitative experimental results have been reported,quantitative and systematic analysis of data is necessary.Particularly,the FLASH effect response model to the dose or dose rate is still unclear.This study investigated the relationships between the FLASH effect and experimental parameters,such as dose,dose rate,and other factors by analyzing published in vivo experimental data from animal models.The data were modeled based on logistic regression analysis using the sigmoid function.The model was evaluated using prediction accuracy,receiver operating characteristic(ROC)curve,and area under the ROC curve.Results showed that the FLASH effect was closely related to the dose,mean dose rate,tissue type,and corresponding biological endpoints.The dose rate corresponding to a 50% probability of triggering cognitive protection in the brain was 45 Gy s^(-1).The dose rate corresponding to a 50% probability of triggering intestinal crypt survival and regeneration was 140 Gy s^(-1).For the skin toxicity effect,the dose corresponding to a 50% probability of triggering the FLASH effect was 24 Gy.This study helps to characterize the conditions underlying the FLASH effect and provides important information for optimizing experiments. 展开更多
关键词 FLASH radiotherapy Sparing effect Systematic analysis dose rate dose Biological endpoints
下载PDF
Comprehensive Evaluation of Flower Border Application Value of New and Superior Plants in Hefei Area 被引量:1
11
作者 MENG Yi ZHAO Zhiyan +1 位作者 LIANG Tingwu LU Zhaoliang 《Journal of Landscape Research》 2024年第2期69-71,76,共4页
An analytic hierarchy process(AHP)was employed to assess the applicability of 18 new and superior varieties of flowers in Hefei City flower border applications.A total of 12 indicators were selected from three distinc... An analytic hierarchy process(AHP)was employed to assess the applicability of 18 new and superior varieties of flowers in Hefei City flower border applications.A total of 12 indicators were selected from three distinct aspects of adaptability,ornamental characteristics and use traits,in order to establish a comprehensive evaluation model.The results demonstrate that grade I(J≥2.685)exhibits excellent application value,encompassing six species of plants,such asHydrangeamacrophylla‘Endless Summer’;grade II(2.684≤J≤2.420)is also of notable application value,encompassing five species of plants,such asCallistemonrigidus;grade III(2.419≤J≤2.615)is of average application value,including five species of plants,such asCrocosmiacrocosmiflora;grade IV(J≤2.16)is of relatively poor application value.The evaluation results may be utilized as a theoretical reference for the promotion of new and superior varieties in the flower border of Hefei. 展开更多
关键词 Analytic hierarchy process(AHP) New and superior variety Application value Comprehensive evaluation
下载PDF
Feasibility of Integrating Leprosy Post-Exposure Prophylaxis with Single-Dose Rifampicin (LPEP) into Routine Leprosy Control Program in Bukedi and Teso Regions in Uganda
12
作者 Rose Kengonzi Turyahabwe Stavia +9 位作者 Lisa Gerwing-Adima Nyote Ronald Kamara Vincent Consolata Mbambara Yusuf Wanyama Buyinza Godfrey Tinyo Daniel Mulwani Elisa Namuyode Damali Aloket Francis 《Advances in Infectious Diseases》 CAS 2024年第3期563-580,共18页
Background: World Health Organization recommends the implementation of contact tracing and Leprosy Post Exposure prophylaxis (LPEP) to interrupt the chain of transmission. To accelerate the uptake of this recommendati... Background: World Health Organization recommends the implementation of contact tracing and Leprosy Post Exposure prophylaxis (LPEP) to interrupt the chain of transmission. To accelerate the uptake of this recommendation, a cross-sectional study among contacts of leprosy patients was conducted to investigate the feasibility of integrating leprosy systematic contact tracing and post-exposure prophylaxis (PEP) into the routine leprosy control program. Methods: This was a mixed methods cross-sectional study. The study was implemented in Kumi, Ngora, Serere, Soroti, Budaka and Kibuku Districts. Results: The 45 enrolled index patients (97.8% of the registered) identified a total of 135 contacts, of which 134 (99·2%) consented and were screened. Among them, one new leprosy patient was identified and started on treatment with multidrug therapy (MDT). All the eligible contacts, received the prophylactic treatment with Single Dose Rifampicin (SDR). Overall, SDR was administered to 133(98.5% of the listed contacts) with no adverse event reported. Factors associated with successful contact investigation and management included: Involvement of index patients, health care workers during the contact screening and SDR A administration, counselling of the index patients and contacts by the health care works, LPEP being administered as Directly observed Therapy (DOT) among others. Results Interpretation: The integration of leprosy post-exposure prophylaxis with administration of SDR and contact tracing is feasible, generally accepted by the patient, their contacts and health workers and can be integrated into the National Leprosy control programmes with minimal additional efforts once contact tracing has been established. Therefore, we recommend integration of administration of SDR in to the routine leprosy control program. 展开更多
关键词 LEPROSY Post Exposure Prophylaxis Single dose Rifampicin
下载PDF
Role of high-dose amoxicillin dual therapy for Helicobacter pylori eradication in an Irish cohort:A prospective study
13
作者 Raffaele Palmirotta Concetta Cafiero Marica Colella 《World Journal of Clinical Cases》 SCIE 2024年第35期6859-6863,共5页
Helicobacter pylori(H.pylori)infections may cause chronic gastritis,peptic ulcer disease,gastric cancers,and other conditions outside of the gastrointestinal tract.Hence,it is important to diagnose and treat it early.... Helicobacter pylori(H.pylori)infections may cause chronic gastritis,peptic ulcer disease,gastric cancers,and other conditions outside of the gastrointestinal tract.Hence,it is important to diagnose and treat it early.H.pylori is resistant to certain drugs in traditional eradication therapy,so alternative therapy protocols are needed,such as high-dose amoxicillin dual therapy(HDADT).This article aims to comment on a recent paper by Costigan et al in the World Journal of Clinical Cases.In this study,the authors recruited 139 patients diagnosed with H.pylori,all treated with HDADT.Of these,93 were treatment-naïve and 46 had received at least one alternative treatment in the past.Four weeks after the end of the treatment,the urea breath test was administered to estimate the eradication rate.The total eradication rate was 56%(78/139),62%for the treatment-naïve arm and 43%for the previous treatment arm,thus indicating a lower success rate for the arm that had previously received a different treatment regimen.In conclusion,a therapeutic approach with first-line HDADT may potentially be a better treat-ment,but the results are not sufficient to recommend the use of this regimen in a country with high levels of dual resistance. 展开更多
关键词 Helicobacter pylori Helicobacter pylori eradication High dose amoxicillin High dose amoxicillin dual therapy Triple therapy
下载PDF
Accurate models and nutritional strategies for specific oxidative stress factors: Does the dose matter in swine production?
14
作者 Changming Hong Yujian Huang +6 位作者 Shuting Cao Li Wang Xuefen Yang Shenglan Hu Kaiguo Gao Zongyong Jiang Hao Xiao 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2024年第2期519-534,共16页
Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxid... Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxidant strategies in relation to oxidative stress-induced pig production,it remains so far largely unsuccessful to develop accurate models and nutritional strategies for specific oxidative stress factors.Here,we discuss the dose and dose intensity of the causes of oxidative stress involving physiological,environmental and dietary factors,recent research models and the antioxidant strategies to provide theoretical guidance for future oxidative stress research in swine. 展开更多
关键词 Accurate models dose Nutritional strategies Oxidative stress SWINE
下载PDF
Helicobacter pylori:High dose amoxicillin does not improve primary or secondary eradication rates in an Irish cohort
15
作者 Conor Costigan Aoife M O'Sullivan +10 位作者 Jim O'Connell Shreyashee Sengupta Thomas Butler Stephen Molloy Fintan John O'Hara Barbara Ryan Niall Breslin Sarah O'Donnell Anthony O'Connor Sinead Smith Deirdre McNamara 《World Journal of Clinical Cases》 SCIE 2024年第16期2773-2779,共7页
BACKGROUND Helicobacter pylori(H.pylori)eradication rates have fallen globally,likely in large part due to increasing antibiotic resistance to traditional therapy.In areas of high clarithromycin and metronidazole resi... BACKGROUND Helicobacter pylori(H.pylori)eradication rates have fallen globally,likely in large part due to increasing antibiotic resistance to traditional therapy.In areas of high clarithromycin and metronidazole resistance such as ours,Maastricht VI guidelines suggest high dose amoxicillin dual therapy(HDADT)can be considered,subject to evidence for local efficacy.In this study we assess efficacy of HDADT therapy for H.pylori eradication in an Irish cohort.AIM To assess the efficacy of HDADT therapy for H.pylori eradication in an Irish cohort as both first line,and subsequent therapy for patients diagnosed with H.pylori.METHODS All patients testing positive for H.pylori in a tertiary centre were treated prospectively with HDADT(amoxicillin 1 g tid and esomeprazole 40 mg bid×14 d)over a period of 8 months.Eradication was confirmed with Urea Breath Test at least 4 wk after cessation of therapy.A delta-over-baseline>4%was considered positive.Patient demographics and treatment outcomes were recorded,analysed and controlled for basic demographics and prior H.pylori treatment.RESULTS One hundred and ninety-eight patients were identified with H.pylori infection,10 patients were excluded due to penicillin allergy and 38 patients refused follow up testing.In all 139 were included in the analysis,55%(n=76)were female,mean age was 46.6 years.Overall,93(67%)of patients were treatment-naïve and 46(33%)had received at least one previous course of treatment.The groups were statistically similar.Self-reported compliance with HDADT was 97%,mild side-effects occurred in 7%.There were no serious adverse drug reactions.Overall the eradication rate for our cohort was 56%(78/139).Eradication rates were worse for those with previous treatment[43%(20/46)vs 62%(58/93),P=0.0458,odds ratio=2.15].Age and Gender had no effect on eradication status.CONCLUSION Overall eradication rates with HDADT were disappointing.Despite being a simple and possibly better tolerated regime,these results do not support its routine use in a high dual resistance country.Further investigation of other regimens to achieve the>90%eradication target is needed. 展开更多
关键词 Helicobacter pylori eradication Helicobacter pylori High dose amoxicillin High dose amoxicillin dual therapy Triple therapy
下载PDF
A Bioequivalence Study of Empagliflozin/Metformin Fixed-Dose Combination in Healthy Subjects under Fasting Conditions
16
作者 Evelyn Pena Alfredo Inatti +2 位作者 Anyoly Taly José Chacón Xenon Serrano-Martin 《Journal of Biosciences and Medicines》 2024年第9期235-250,共16页
Background: This study evaluated the bioequivalence of empagliflozin 12.5 mg/metformin 1000 mg tablets compared to Synjardy® (Empagliflozin 12.5 mg/metformin 1000 mg) tablets in healthy male subjects under fastin... Background: This study evaluated the bioequivalence of empagliflozin 12.5 mg/metformin 1000 mg tablets compared to Synjardy® (Empagliflozin 12.5 mg/metformin 1000 mg) tablets in healthy male subjects under fasting conditions. Methods: This was a phase I, randomized, single-dose, two-period, two-sequence, crossover study to evaluate the bioequivalence (BE) profiles of two fixed-dose combinations (FDCs) of empagliflozin/metformin. Cmax, AUC0-t and AUC0-∞ from test and reference formulations were evaluated to access BE. The plasma concentrations were measured using a validated liquid chromatography-mass spectrometry (LC-MS/MS) method. Of the 24 subjects enrolled, 23 completed both periods of the study. The two formulations test and reference were considered bioequivalent if 90% confidence interval (CI) fell within 80.00% - 125.00% for Cmax, AUC0-t and AUC0-∞. Tolerability and safety were assessed throughout the study. Results: The pharmacokinetic (PK) parameters were similar between the test product (T) and reference product (R) Synjardy®. The 90% CI of the test/reference ratios of log-transformed PK parameters point estimates was Cmax: 89.87% (85.68% - 94.27%), AUC0-t: 87.91% (83.65% - 92.39%) and AUC0-∞: 87.16% (82.80% - 91.75%) to empagliflozin and Cmax: 92.19% (87.95% - 96.65%), AUC0-t: 91.38% (84.42% - 98.91%) and AUC0-∞: 93.78% (83.82% - 104.93%) to metformin respectively (90% CI for all PK parameters fell within 80.00% - 125.00%). Conclusion: Our results demonstrated BE between the test and reference formulations of oral tablets of empagliflozin 12.5 mg/metformin 1000 mg (FDC) in healthy male subjects under fasting conditions. 展开更多
关键词 BIOEQUIVALENCE Fix dose Combinations PHARMACOKINETIC Empagliflozin
下载PDF
Validation of the TOPAS Monte-Carlo Code of the Off-Field Dose of a 6 MV Synergy Linac
17
作者 Kodjo Joel Fabrice N’Guessan Ibrahima Sakho Bogbé D. L. H. Gogon 《Journal of Biosciences and Medicines》 2024年第7期38-54,共17页
The risk of radiation-induced second cancer and the late tissue loss due to Off-field doses in radiotherapy remain a serious concern. Monte Carlo (MC) simulation is currently one of the most accurate methods for calcu... The risk of radiation-induced second cancer and the late tissue loss due to Off-field doses in radiotherapy remain a serious concern. Monte Carlo (MC) simulation is currently one of the most accurate methods for calculating these doses. MC simulation model based on the Particle Simulation Tool (TOPAS) has been developed to simulate the off-field dose of an Elekta Synergy linear accelerator (Linac) emitting 6 MV photons. Measurements were taken in a water phantom using an ionization chamber to validate this model. The Percentage Depth Dose (PDD) at the depth of 0.0, 5.0, 10.0 and 15.0 cm from the beam axis for a 10 × 10 cm2 field size was measured and simulated. Off-field dose profiles at the depth of 1.5 (dmax), 5.0 and 10.0 cm for field sizes of 5 × 5, 10 × 10, 15 × 15, and 20 × 20 cm2 respectively were measured and simulated. Comparison of measured and simulated off-field dose values showed a good agreement. The average gamma passing rate of the PDDs and profiles curves for off-field doses were 87.5% and 98.11% respectively. The local dose difference based on the PDD curve between the measured and simulated was less than 6.0 % for all locations. For all field size considered in this study, the average difference between profile curves for off-field dose measured and simulated was 9.1%. PDDs and Profiles curves for off-field dose simulation uncertainties were less than 2.0% and 1.0% respectively. TOPAS-MC simulation model developed is a good representation of our 6 MV Linac Elekta Synergy for assessing off-field dose, which would be the primary cause of some secondary cancers. 展开更多
关键词 Radiotherapy Off-Field dose Secondary Cancer TOPAS-MC Simulation DOSIMETRY
下载PDF
Evaluation Test Research of DR Inspection System for Circumferential Welds in Long Distance Pipeline
18
作者 WANG Changjiang WANG Xue +4 位作者 ZHANG Shimin ZHAO Yan LYU Xinyu ZHONG Qian ZHOU Guangyan 《材料导报》 EI CAS CSCD 北大核心 2024年第22期223-229,共7页
Digital radiographic(DR)testing equipment has been widely promoted and applied in the inspection of circumferential welds in oil and gas pipelines.In order to establish a comprehensive quality control system for digit... Digital radiographic(DR)testing equipment has been widely promoted and applied in the inspection of circumferential welds in oil and gas pipelines.In order to establish a comprehensive quality control system for digital radiographic testing and fully evaluate the integrated system inspection ability of equipment,personnel,and processes,a scientific and standardized evaluation method to the system is very necessary.Here investigates the precedents of relevant non-destructive testing evaluation methods at home and abroad,considers the testing characteristics of DR equipment,develops a complete set of DR testing system evaluation procedures.It deeply studies the adaptability methods of program processes from defect production to slicing processing and data statistical calculation for digital radiographic testing evaluation.To check the repeatability and reliability of the detectable system,five process welds with 200 real metallographic defects were fabricated in the laboratory.From the detected results,the DR system has good repeatability in image quality,and the detectable defect size reaches 0.85 mm under achieving 90%detection probability at a confidence level of 95%,the error of detected defect length is±2 mm,and the error of detected defect localization is±5 mm.The qualitative and quantitative detection of defects are accurate and reliable.The test further confirmed the reliable detection ability of the DR detection system,and fully validated the scientific and practical evaluation method designed.The research on the evaluation test method can serve as an important link in the quality control system for the on-site application of digital ray equipment in long-distance pipelines.The designed program,test,and evaluation content can serve as an important basis for the formulation of relevant specifications or standards. 展开更多
关键词 digital ray evaluation test REPEATABILITY RELIABILITY
下载PDF
Research on a TOPSIS energy efficiency evaluation system for crude oil gathering and transportation systems based on a GA-BP neural network
19
作者 Xue-Qiang Zhang Qing-Lin Cheng +2 位作者 Wei Sun Yi Zhao Zhi-Min Li 《Petroleum Science》 SCIE EI CAS CSCD 2024年第1期621-640,共20页
As the main link of ground engineering,crude oil gathering and transportation systems require huge energy consumption and complex structures.It is necessary to establish an energy efficiency evaluation system for crud... As the main link of ground engineering,crude oil gathering and transportation systems require huge energy consumption and complex structures.It is necessary to establish an energy efficiency evaluation system for crude oil gathering and transportation systems and identify the energy efficiency gaps.In this paper,the energy efficiency evaluation system of the crude oil gathering and transportation system in an oilfield in western China is established.Combined with the big data analysis method,the GA-BP neural network is used to establish the energy efficiency index prediction model for crude oil gathering and transportation systems.The comprehensive energy consumption,gas consumption,power consumption,energy utilization rate,heat utilization rate,and power utilization rate of crude oil gathering and transportation systems are predicted.Considering the efficiency and unit consumption index of the crude oil gathering and transportation system,the energy efficiency evaluation system of the crude oil gathering and transportation system is established based on a game theory combined weighting method and TOPSIS evaluation method,and the subjective weight is determined by the triangular fuzzy analytic hierarchy process.The entropy weight method determines the objective weight,and the combined weight of game theory combines subjectivity with objectivity to comprehensively evaluate the comprehensive energy efficiency of crude oil gathering and transportation systems and their subsystems.Finally,the weak links in energy utilization are identified,and energy conservation and consumption reduction are improved.The above research provides technical support for the green,efficient and intelligent development of crude oil gathering and transportation systems. 展开更多
关键词 Crude oil gathering and transportation system GA-BP neural network Energy efficiency evaluation TOPSIS evaluation method Energy saving and consumption reduction
下载PDF
Life Time Attributable Cancer Risk Estimated Using Scanner Reported Dose Length Product during Chest Computed Tomography Imaging in Young Children
20
作者 Mousa Bakkari Khaled Soliman +3 位作者 Abdullah Alrushoud Marwan Fahad Alosaimi Hanaa Alsheikh Abdelwahed Alhejaili 《Open Journal of Radiology》 2024年第2期74-82,共9页
This study aims to estimate the lifetime attributable cancer risk (LAR) for pediatric chest computed tomography (CT) examinations in five age groups using recently published age and region-specific conversion coeffici... This study aims to estimate the lifetime attributable cancer risk (LAR) for pediatric chest computed tomography (CT) examinations in five age groups using recently published age and region-specific conversion coefficients multiplying the widely available scanner registered dose length products (DLP) displayed on the CT console and hence calculating the Effective Dose (ED). The ED is then multiplied by the International Commission on Radiological Protection (ICRP) published risk factor for LAR. The obtained LAR values are compared with the international literature. Factors that may affect the LAR value are reported and discussed. The study included one hundred twenty five chest CT examinations for both males and females aged from less than one year to fifteen years. The patients reported data are from one single medical institution and using two CT scanners from June 2022 to December 2023. The results of this study may serve as benchmark for institutional radiation dose reference levels and risk estimation. 展开更多
关键词 Cancer Risk LAR Chest CT Pediatric Radiology Radiation dose DLP