期刊文献+
共找到1,644篇文章
< 1 2 83 >
每页显示 20 50 100
Systematic analysis and modeling of the FLASH sparing effect as a function of dose and dose rate
1
作者 Qi-Bin Fu Yan Zhang +3 位作者 Yu-Cheng Wang Tu-Chen Huang Hong-Yu Zhu Xiao-Wu Deng 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期51-58,共8页
Ultrahigh-dose-rate radiotherapy(FLASH-RT)is a revolutionary radiotherapy technology that can spare normal tissues without compromising tumor control.Although qualitative experimental results have been reported,quanti... Ultrahigh-dose-rate radiotherapy(FLASH-RT)is a revolutionary radiotherapy technology that can spare normal tissues without compromising tumor control.Although qualitative experimental results have been reported,quantitative and systematic analysis of data is necessary.Particularly,the FLASH effect response model to the dose or dose rate is still unclear.This study investigated the relationships between the FLASH effect and experimental parameters,such as dose,dose rate,and other factors by analyzing published in vivo experimental data from animal models.The data were modeled based on logistic regression analysis using the sigmoid function.The model was evaluated using prediction accuracy,receiver operating characteristic(ROC)curve,and area under the ROC curve.Results showed that the FLASH effect was closely related to the dose,mean dose rate,tissue type,and corresponding biological endpoints.The dose rate corresponding to a 50% probability of triggering cognitive protection in the brain was 45 Gy s^(-1).The dose rate corresponding to a 50% probability of triggering intestinal crypt survival and regeneration was 140 Gy s^(-1).For the skin toxicity effect,the dose corresponding to a 50% probability of triggering the FLASH effect was 24 Gy.This study helps to characterize the conditions underlying the FLASH effect and provides important information for optimizing experiments. 展开更多
关键词 FLASH radiotherapy Sparing effect Systematic analysis dose rate dose Biological endpoints
下载PDF
Laser-assisted Simulation of Dose Rate Effects of Wide Band Gap Semiconductor Devices
2
作者 TANG Ge XIAO Yao +3 位作者 SUN Peng LIU Jingrui ZHANG Fuwang LI Mo 《原子能科学技术》 EI CAS CSCD 北大核心 2023年第12期2314-2325,共12页
Laser-assisted simulation technique has played a crucial role in the investigation of dose rate effects of silicon-based devices and integrated circuits,due to its exceptional advantages in terms of flexibility,safety... Laser-assisted simulation technique has played a crucial role in the investigation of dose rate effects of silicon-based devices and integrated circuits,due to its exceptional advantages in terms of flexibility,safety,convenience,and precision.In recent years,wide band gap materials,known for their strong bonding and high ionization energy,have gained increasing attention from researchers and hold significant promise for extensive applications in specialized environments.Consequently,there is a growing need for comprehensive research on the dose rate effects of wide band gap materials.In response to this need,the use of laser-assisted simulation technology has emerged as a promising approach,offering an effective means to assess the efficacy of investigating these materials and devices.This paper focused on investigating the feasibility of laser-assisted simulation to study the dose rate effects of wide band gap semiconductor devices.Theoretical conversion factors for laser-assisted simulation of dose rate effects of GaN-based and SiC-based devices were been provided.Moreover,to validate the accuracy of the conversion factors,pulsed laser and dose rate experiments were conducted on GaN-based and SiC-based PIN diodes.The results demonstrate that pulsed laser radiation andγ-ray radiation can produce highly similar photocurrent responses in GaN-based and SiC-based PIN diodes,with correlation coefficients of 0.98 and 0.974,respectively.This finding reaffirms the effectiveness of laser-assisted simulation technology,making it a valuable complement in studying the dose rate effects of wide band gap semiconductor devices. 展开更多
关键词 laser-assisted simulation dose rate effect wide band gap semiconductor conversion factor
下载PDF
Effect of ionizing radiation on dual 8-bit analog-to-digital converters (AD9058) with various dose rates and bias conditions 被引量:1
3
作者 李兴冀 刘超铭 +2 位作者 孙中亮 肖立伊 何世禹 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第9期629-633,共5页
The radiation effects on several properties (reference voltage, digital output logic voltage, and supply current) of dual 8-bit analog-to-digital (A/D) converters (AD9058) under various biased conditions are inv... The radiation effects on several properties (reference voltage, digital output logic voltage, and supply current) of dual 8-bit analog-to-digital (A/D) converters (AD9058) under various biased conditions are investigated in this paper. Gamma ray and 10-MeV proton irradiation are selected for a detailed evaluation and comparison. Based on the measurement results induced by the gamma ray with various dose rates, the devices exhibit enhanced low dose rate sensitivity (ELDRS) under zero and working bias conditions. Meanwhile, it is obvious that the ELDRS is more severe under the working bias condition than under the zero bias condition. The degradation of AD9058 does not display obvious ELDRS during 10-MeV proton irradiation with the selected flux. 展开更多
关键词 analog-to-digital converters enhanced low dose rate sensitivities (ELDRS) gamma ray and protonirradiation lower/high-dose rate
下载PDF
Study of the External Dose Rate and Retained Body Activity of Patients with Hyperthyroidism Who Are Receiving Ⅰ-131 Therapy 被引量:2
4
作者 LIU Yu Lian ZHAO Zhi Xin +4 位作者 HUO Meng Hui YIN Chen TAN Jian ZHANG Wen Yi JIAO Ling 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2018年第12期913-916,共4页
Hyperthyroidism refers to a clinical state that results from inappropriately hight hyroid hormone levels in the tissues;.Ⅰ-131 therapy plays a critical role and provides a remarkable curative effect in targeting thyr... Hyperthyroidism refers to a clinical state that results from inappropriately hight hyroid hormone levels in the tissues;.Ⅰ-131 therapy plays a critical role and provides a remarkable curative effect in targeting thyroid diseases. Thyroid cells can take up isotope I-131, which emits not only beta rays but also 展开更多
关键词 ACTIVITY Therapy Study of the External dose rate and Retained Body Activity of Patients with Hyperthyroidism Who Are Receiving
下载PDF
Calibration of a neutron dose rate meter in various neutron standard fields 被引量:1
5
作者 Tuan Khai Nguyen Hoai-Nam Tran +4 位作者 Quynh Ngoc Nguyen Thi My Linh Dang Van Loat Bui Thiansin Liamsuwan Ngoc-Thiem Le 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第6期75-82,共8页
This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and ... This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and five simulated workplace fields with241Am-Be moderated sources).The calibration in standard fields with bare sources was conducted by following the recommendations of the ISO 8529 standard.The measured total neutron ambient dose equivalent rates,denoted as H*(10)tot,were analyzed to obtain direct components,denoted as H*(10)dir,using a reduced fitting method.The CF was then calculated as the ratio between the conventional true value of the neutron ambient dose equivalent rate in a free field,denoted as H*(10)FF,and the value of H*(10)dir.In contrast,in the simulated workplace neutron fields,the calibration of the neutron dose rate meter was conducted by following the ISO 12789 standard.The CF was calculated as the ratio between the values of H*(10)totmeasured by a standard instrument(i.e.,Bonner sphere spectrometer)and the neutron dose rate meter.The CF values were obtained in the range of 0.88–1.0.The standard uncertainties(k=1)of the CFs were determined to be in the range of approximately 6.6–13.1%. 展开更多
关键词 Neutron standard fields Neutron dose rate meter Calibration factor 252Cf source 241AmBe source
下载PDF
Estimation of enhanced low dose rate sensitivity mechanisms using temperature switching irradiation on gate-controlled lateral PNP transistor 被引量:1
6
作者 Xiao-Long Li Wu Lu +7 位作者 Xin Wang Xin Yu Qi Guo Jing Sun Mo-Han Liu Shuai Yao Xin-Yu Wei Cheng-Fa He 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第3期342-350,共9页
The mechanisms occurring when the switched temperature technique is applied,as an accelerated enhanced low dose rate sensitivity(ELDRS)test technique,are investigated in terms of a specially designed gate-controlled l... The mechanisms occurring when the switched temperature technique is applied,as an accelerated enhanced low dose rate sensitivity(ELDRS)test technique,are investigated in terms of a specially designed gate-controlled lateral PNP transistor(GLPNP)that used to extract the interface traps(Nit)and oxide trapped charges(Not).Electrical characteristics in GLPNP transistors induced by ^(60)Co gamma irradiation are measured in situ as a function of total dose,showing that generation of Nit in the oxide is the primary cause of base current variations for the GLPNP.Based on the analysis of the variations of Nit and Not,with switching the temperature,the properties of accelerated protons release and suppressed protons loss play critical roles in determining the increased Nit formation leading to the base current degradation with dose accumulation.Simultaneously the hydrogen cracking mechanisms responsible for additional protons release are related to the neutralization of Not extending enhanced Nit buildup.In this study the switched temperature irradiation has been employed to conservatively estimate the ELDRS of GLPNP,which provides us with a new insight into the test technique for ELDRS. 展开更多
关键词 ionizing radiation damage enhanced low dose rate sensitivity(ELDRS) switched temperature irradiation gate-controlled lateral PNP transistor(GLPNP)
下载PDF
Study on the dose rate upset effect of partially depleted silicon-on-insulator static random access memory
7
作者 赵发展 刘梦新 +7 位作者 郭天雷 刘刚 海潮和 韩郑生 杨善潮 李瑞宾 林东生 陈伟 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第12期4599-4605,共7页
This paper implements the study on the Dose Rate Upset effect of PDSOI SRAM (Partially Depleted Silicon- On-Insulator Static Random Access Memory) with the Qiangguang-I accelerator in Northwest Institute of Nuclear ... This paper implements the study on the Dose Rate Upset effect of PDSOI SRAM (Partially Depleted Silicon- On-Insulator Static Random Access Memory) with the Qiangguang-I accelerator in Northwest Institute of Nuclear Technology. The SRAM (Static Random Access Memory) chips are developed by the Institute of Microelectronics of Chinese Academy of Sciences. It uses the full address test mode to determine the upset mechanisms. A specified address test is taken in the same time. The test results indicate that the upset threshold of the PDSOI SRAM is about l×10s Gy(Si)/s. However, there are a few bits upset when the dose rate reaches up to 1.58 x 109 Gy(Si)/s. The SRAM circuit can still work after the high level 3~ ray pulse. Finally, the upset mechanism is determined to be the rail span collapse by comparing the critical charge with the collected charge after γ ray pulse. The physical locations of upset cells are plotted in the layout of the SRAM to investigate the layout defect. Then, some layout optimizations are made to improve the dose rate hardened performance of the PDSOI SRAM. 展开更多
关键词 dose rate PDSOI SRAMS upset
下载PDF
Implementation and application of PyNE sub-voxel R2S for shutdown dose rate analysis
8
作者 Xiaokang ZHANG Patrick C SHRIWISE +1 位作者 Songlin LIU Paul P H WILSON 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第9期145-151,共7页
PyNE R2S is a mesh-based R2S implementation with the capability of performing shutdown dose rate(SDR)analysis directly on CAD geometry with Cartesian or tetrahedral meshes.It supports advanced variance reduction for f... PyNE R2S is a mesh-based R2S implementation with the capability of performing shutdown dose rate(SDR)analysis directly on CAD geometry with Cartesian or tetrahedral meshes.It supports advanced variance reduction for fusion energy systems.However,the assumption of homogenized materials of PyNE R2S with a Cartesian mesh throughout a mesh voxel introduces an approximation in the case where a voxel covers multiple non-void cells.This work implements a sub-voxel method to add fldelity to PyNE R2S with a Cartesian mesh during the process of activation and photon source sampling by performing independent inventory calculations for each cell within a mesh voxel and using the results of those independent calculations to sample the photon source more precisely.PyNE sub-voxel R2S has been verifled with the Frascati Neutron Generator(FNG)-ITER and ITER computational shutdown dose rate benchmark problems.The results for sub-voxel R2S show satisfactory agreement with the experimental values or reference results.PyNE sub-voxel R2S has been applied to the shutdown dose rate calculation of the Chinese Fusion Engineering Testing Reactor(CFETR).In conclusion,sub-voxel R2S is a reliable tool for SDR calculation and obtains more accurate results with the same voxel size than voxel R2S. 展开更多
关键词 shutdown dose rate R2S sub-voxel PyNE
下载PDF
The Experience of Pain and Anxiety in Cervical Cancer Patients Undergoing Multiple Fraction High-Dose Rate Brachytherapy: A Prospective Observational Study
9
作者 Kenza Benali Mohammed Adnane Tazi +5 位作者 Gael Kietga Tayeb Kebdani Khalid Hassouni Sanaa El Majjaoui Hanan El Kacemi Noureddine Benjaafar 《Journal of Cancer Therapy》 CAS 2022年第7期405-416,共12页
Purpose: To evaluate the anxiety and pain levels of cervical cancer patients undergoing intracavitary multifraction high-dose rate (HDR) brachytherapy, as part of a process to develop guidelines for quality patient-ce... Purpose: To evaluate the anxiety and pain levels of cervical cancer patients undergoing intracavitary multifraction high-dose rate (HDR) brachytherapy, as part of a process to develop guidelines for quality patient-centered care. Methods: Cervical cancer patients (n = 31) undergoingmultiple fraction HDR brachytherapy treatment at the National Institute of Oncology in Rabat (Morocco) completed ratings of pain and anxiety intensity using 11-point verbal analog scales, at 6 key time points over 2 brachytherapy insertion procedures and 4 brachytherapy fractions. Women were evaluated for psychological status at baseline before starting the brachytherapy process using the Hospital Anxiety and Depression Scale (HADS). Scores were grouped as follows: 0 - 7 = normal, 8 - 10 = borderline, 11 - 21 = abnormal. Factors that could affect anxiety levels such as education level, relationship status, number of pregnancies and prior surgical history were documented. Results: Between July and August 2020, 31 women with a median age of 49.6 years were evaluated (range: 27 - 70). The HADS score identified depression in 5 patients (16.1%) and anxiety in 12 patients (38.7%). Throughout both treatment procedures, anticipatory anxiety was reported, with a maximum intensity in the operating room during spinal anesthesia (3.23 ± 1.7) and during applicator insertion (2.97 ± 2.4). Moderate-to-severe anxiety scores were reported in 25.8% and 22.6% of patients respectively. Level of education showed a significant correlation with anxiety scores (p = 0.027). Pain increased significantly during the procedure (p ± 1.4) and applicator removal (4.74 ± 1.5) turned out to be the most painful parts of the procedure. No correlation was found between pain and anxiety levels. Conclusion: Intracavitary multifraction high-dose rate brachytherapy is associated with mild to moderate levels of pain and anxiety, although a subset of patients reported more severe symptoms and may require additional medical and psychological support, with particular emphasis on bed-rest duration and applicator removal. The development of effective interventions (both pharmacological and non-pharmacological) is needed to improve women’s experiences of brachytherapy for locally advanced cervical cancer. 展开更多
关键词 Cervical Cancer BRACHYTHERAPY High-dose rate PAIN ANXIETY
下载PDF
Study of the Photon Flux and the Dose Rate in the Vicinity of a 60Co Gamma Irradiator
10
作者 Elassaad Jemii Lotfi Ghedira 《World Journal of Nuclear Science and Technology》 2016年第2期89-95,共7页
The present work presents an overview of the study of some dosimetric quantities in the vicinity of the Tunisian Gamma Irradiation Facility. Firstly, we have confirmed our previous calculation of the photon flux and t... The present work presents an overview of the study of some dosimetric quantities in the vicinity of the Tunisian Gamma Irradiation Facility. Firstly, we have confirmed our previous calculation of the photon flux and the dose rates, using a simulation with GEANT 4. A good agreement between calculation and simulation was obtained, which well confirmed the modeling of the CNSTN extended source by a pencil-like source. Secondly we have determined the isodose curves in the vicinity of the irradiator using a straightforward calculation. Finally, we have presented many comments for some published work concerning the methods used to determine these dosimetric quantities. 展开更多
关键词 Photon Flux dose rates Simulation GEANT 4 Isodose Curves
下载PDF
Energy spectrum measurement and dose rate estimation of natural neutrons in Tibet region 被引量:1
11
作者 吴建华 徐勇军 +1 位作者 刘森林 汪传高 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第6期25-28,共4页
In this work, natural neutron spectra at nine sites in Tibet region were measured using a multi-sphere neutron spectrometer. The altitude-dependence of the spectra total fluence rate and ambient dose equivalent rate w... In this work, natural neutron spectra at nine sites in Tibet region were measured using a multi-sphere neutron spectrometer. The altitude-dependence of the spectra total fluence rate and ambient dose equivalent rate were analyzed. From the normalized natural neutron spectra at different altitudes, the spectrum fractions for neutrons of greater than 0.1 MeV do not differ obviously, while those of the thermal neutrons differ greatly from each other. The total fluence rate, effective dose rate and the ambient dose equivalent rate varied with the altitude according to an exponential law. 展开更多
关键词 中子能谱测量 西藏地区 剂量率 剂量当量率 估算 天然 能量密度 高度变化
下载PDF
Fixed Dose Rate versus Standard Dose Rate Infusion of Gemcitabine and Cisplatin in Advanced Stage Non-Small Cell Lung Cancer 被引量:1
12
作者 Dina A. Salem Dina R. Ibrahim +1 位作者 Ahmed Ezzat Azza M. Adel 《Journal of Cancer Therapy》 2015年第1期45-52,共8页
Background: Comparing the efficacy and safety of gemcitabine at a fixed-dose rate (FDR) infusion (10 mg/m2/min) with the standard dose rate infusion in patients with locally advanced and metastatic non-small squamous ... Background: Comparing the efficacy and safety of gemcitabine at a fixed-dose rate (FDR) infusion (10 mg/m2/min) with the standard dose rate infusion in patients with locally advanced and metastatic non-small squamous cell carcinoma (NSCLC). Methods: The study randomized 60 patients with confirmed diagnosis of NSCLC to receive gemcitabine at a dose of 1000 mg/m2 on days 1 and 8 given as a 30-min infusion (Arm A) or at a rate of 10 mg/m2/min (Arm B). Cisplatin 75 mg/m2 was administered intravenously on day 2 in both arms. Results: No difference in overall response rate (46.6% versus 43.3%). Median time to progression for Arm A was 7 months (95% CI, 6.207 - 7.793 months), versus 6 months for Arm B (95% CI, 4.990 - 7.010 months). Median survival time was comparable [12 months (95% CI, 8.588 - 15.412 months) versus 11 months (95% CI, 9.066 - 12.934 months)] respectively. Two-year survival (18% versus 11%, p = 0.38) was detected. No treatment related deaths occurred. Main hematological toxicities were grade I and II neutropenia, in 36.7% and 53.3% respectively (p = 0.044). Grade III anemia was observed in 10% and 6.7% in both arms respectively (p = 0.024). Grade I and II nausea and vomiting was observed in 50% and 46.7%. Conclusions: FDR gemcitabine in combination with cisplatin had equivalent efficacy and more severe hematologic toxicities compared to the standard 30-min gemcitabine infusion with cisplatin in patients with advanced NSCLC. 展开更多
关键词 NON-SMALL Cell Lung Cancer GEMCITABINE Fixed-dose rate TOXICITIES
下载PDF
TrueBeam Low Dose Rate Investigation for Pulsed Reduced Dose Rate IMRT
13
作者 Mark Geurts 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2017年第2期139-149,共11页
The capability of the TrueBeam treatment system to deliver step and shoot IMRT plans at low dose rates was evaluated. Beam characteristics during low dose rates (5 to 100 MU/min) were evaluated for consistency using a... The capability of the TrueBeam treatment system to deliver step and shoot IMRT plans at low dose rates was evaluated. Beam characteristics during low dose rates (5 to 100 MU/min) were evaluated for consistency using a planar ion chamber array. MU constancy, linearity, and beam profile symmetry were all found to be equivalent within 0.5%. The response of the Scandi Dos Delta 4 system was also evaluated at low dose rates of using static open beams compared to ion chamber measurements, and step and shoot IMRT plans comparing 5 - 20 MU/min and 100 MU/min dose rates, with a maximum observed absolute dose difference of 0.8% and equivalence margin of 0.2%. The Gamma Index and measurement reproducibility were also found to be equivalent. 展开更多
关键词 PRDR Low dose rate DELTA 4 TrueBeam
下载PDF
Will High Dose Rate Interstitial Brachytherapy Be a Surrogate to Surgery in Early Mobile Squamous Cell Carcinoma of Tongue—An Indian Experience
14
作者 Parthasarathy Vedasoundaram K. S. Reddy +4 位作者 Gangotri Selvarajan Saravanan Kandasamy Mourougan Sinnathambi Muzamil Asif Vivekanandam Singhavajhala 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2014年第3期143-155,共13页
The study was intended to highlight functional outcome and survival advantage when High Dose Rate (HDR) interstitial implant was used for anterior 2/3rd tongue, either as a primary or as boost depending upon stage of ... The study was intended to highlight functional outcome and survival advantage when High Dose Rate (HDR) interstitial implant was used for anterior 2/3rd tongue, either as a primary or as boost depending upon stage of disease. Materials and Methods: Fifty-one patients with squamous cell carcinoma of anterior 2/3rd tongue received interstitial brachytherapy either as primary or as boost with Iridium 192 remote after loading high dose rate (Microselectron or Gamma MediX) machines from November 2008 to September 2013. Age group ranged from 32 to 73 years, mean 52.1. Of these 51, 37 were males and 14 were females. 8 patients belonged to Stage I, 18 from Stage II and 28 patients were Stage III. Stage I patients received primary brachytherapy alone of dose 38.50 Gy to 40 Gy and fraction dose ranged from 250 cGy to 350 cGy. Stage II and Stage III patients received external beam radiation of dose 44 Gy/200cGy per fraction for 22 fractions followed by spinal cord sparing for 6 Gy/200cGy per fraction for 3 fractions. Brachytherapy boost of dose 21 Gy was delivered after external beam radiation. Stage III patients received concurrent chemotherapy with Injection Cisplatin along with external beam radiotherapy 44 Gy/200cGy per fraction for 22 fractions followed by spinal cord sparing for 6 Gy/200cGy per fraction for 3 fractions. Brachytherapy boost of dose 21 Gy was delivered after external beam radiation. 55% of patients were habituated to tobacco and alcohol in one form or the other or both. Surprisingly 45% of patients were nonsmokers and non-alcoholic. Results: Follow-up period ranged from eight months to sixty months. 42 patients had complete response. 9 patients had residual disease. 2 patients died due to non-cancerous cause though they had excellent local control, one with pulmonary tuberculosis and the other with massive Myocardial Infarction. 2 patients died due to disease progression. Overall complete response rate was 82.35%. Those patients who had good coverage index and conformal index had good response compared to those patients with lesser these values. Conclusion: It is surprising to observe from the study that oral cavity cancers are not uncommon in non-smokers and non-alcoholics. Overall complete response of 82% is comparable to any other study quoted in literature. Surgery offers same cure rate but at the rate of organ loss and functional impairment. Organ preservation with good functional outcome is possible in radiotherapy unlike surgery. This study proves brachytherapy can be considered as a surrogate to surgery in early stage tongue cancers with good functional outcome and with lesser morbidity. 展开更多
关键词 TONGUE Cancer High dose rate INTERSTITIAL BRACHYTHERAPY ORGAN PRESERVATION
下载PDF
Organ at Risk Doses during High Dose Rate Intracavitary Brachytherapy for Cervical Cancer: A Dosimetric Study
15
作者 N. V. Vinin Joneetha Jones +6 位作者 V. T. Ajas Geetha Muttath C. A. Suja E. K. Nabeel Yahiya P. N. Shoaib Nawaz Arun P. Narendran P. Shimjith 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第4期472-478,共7页
Background: Treatment of Cervical cancer includes a combination of external beam radiotherapy (EBRT) with intracavitary brachytherapy (ICBT). ICBT helps to boost radiation dose to primary disease. Organs like rectum, ... Background: Treatment of Cervical cancer includes a combination of external beam radiotherapy (EBRT) with intracavitary brachytherapy (ICBT). ICBT helps to boost radiation dose to primary disease. Organs like rectum, bladder, sigmoid and small bowel lie close to the cervix region and these organs receive dose from EBRT as well as ICBT and we want to know the dose to these organ at risk (OAR). Materials & Methods: Dosimetric details of 174 ICBT applications done in 58 patients were retrospectively analysed. All patients received EBRT dose of 50.4 Gy in 28 fractions. All patients had ICBT, three sessions with 7 Gy prescribed to point A. Dosimetric data including dose to right and left point A and dose to OARs were recorded from Oncentra Planning System. Results: Mean dose to point A on right side was 6.89 Gy and left side was 6.91 Gy. Mean D2cc dose to rectum, bladder, sigmoid and small bowel was 3.5 Gy, 5.25 Gy, 4.75 Gy and 4.2 Gy respectively. Mean EQD2 dose combining EBRT and ICBT in point A was 78.7 Gy on right side and 79 Gy on left side. Mean EQD2 doses to D2cc of rectum, bladder, sigmoid and small bowel was 62 Gy, 74.4 Gy, 70.5 Gy and 66.5 Gy respectively. Conclusion: From the results of this dosimetric study it is evident that OARs like rectum, sigmoid, bladder & bowel are receiving only acceptable doses of radiation using point A prescribed CT based ICBT planning. Hence with regards to OAR doses, CT based ICBT planning with dose prescribed to point A is a feasible option. 展开更多
关键词 Intracavitary BRACHYTHERAPY CARCINOMA CERVIX ORGAN at Risk High dose rate BRACHYTHERAPY
下载PDF
Commissioning and Optimization of a Total Skin Electron Therapy Technique Using a High Dose Rate Electron Facility
16
作者 Y. A. M. Yousif Casper A. Willemse 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第3期197-207,共11页
Total skin electron therapy (TSET) is used for the treatment of Mycosis Fungoides. Several tech-niques have been developed, in order to achieve homogeneous dose distribution over the complete body surface. To implemen... Total skin electron therapy (TSET) is used for the treatment of Mycosis Fungoides. Several tech-niques have been developed, in order to achieve homogeneous dose distribution over the complete body surface. To implement a TSET technique, one has to optimize a variety of parameters. Monte Carlo simulation of TSET can facilitate this optimization. The aim of this study was to commission and optimize a TSET technique using the 4 and 6 MeV electron and the high dose rate facility on the Elekta Precise accelerator. The EGS4nrc/BEAMnrc Monte Carlo code was used. The beam data were calculated and measured at two different scoring planes for a single beam. The Model was validated by comparing the simulation with measurements. Two different vertical angles were used to obtain a uniform dose. The angle was optimized for best dose uniformity. The Rando phantom is placed on a rotating platform and rotates 60 degrees apart to facilitate the six patient position orientations. The doses delivered in a phantom by complete treatment were measured with Kodak EDR2 films and TLDs. The dose distribution varied among various scanning directions by 2 - 3 mm and 3 - 4 mm for 4 and 6 MeV respectively. The composite percentage depth dose of all six dual fields for the 4 and 6 MeV yielded an R80 of ~4 mm and ~6 mm, respectively. Dose uniformity was ±6% for 4 MeV and ±5% for 6 MeV. The bremsstrahlung contamination was 0.9% - 1.3%. Good agreements were found with published literature and inline with international protocols. 展开更多
关键词 TOTAL SKIN ELECTRON THERAPY MYCOSIS Fungoides High dose rate ELECTRON Monte Carlo Simulation
下载PDF
Relationship between Patient-Dependent Parameters and Radiation Dose Rates Measured around Patients Undergoing PET/CT Imaging Using <sup>18</sup>F-FDG
17
作者 Khaled Soliman Saad Al Qahtani Ahmed Alenezi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第3期403-413,共11页
Objectives: Patients undergoing 18F-FDG PET/CT imaging are considered external radiation sources. Accurate dose rate estimates are important for conducting realistic risk assessments and performing dose reconstruction... Objectives: Patients undergoing 18F-FDG PET/CT imaging are considered external radiation sources. Accurate dose rate estimates are important for conducting realistic risk assessments and performing dose reconstruction in cases of accidental exposures. The patient radiation self-attenuation factor is assumed to be a function of the patient’s body size metrics, but we can use these metrics to predict the dose rate around the patients with accuracy. The objective of this work was first to measure the patient attenuation factor by performing direct dose rate measurements from patients undergoing PET/CT imaging studies using 18F-FDG. The second objective was to study the possible correlation between the measured dose rate constant per unit activity from the patients and their body size metrics;five metrics were tested in this work. The last objective was to measure the patients’ voiding factor. Methods: We have measured dose rates at one meter from 57 patients and noted the patient’s height (H), weight (W) and calculated patient size metrics namely: Equivalent Cylindrical Diameter (ECD), Equivalent Spherical Diameter (ESD) and the Body Mass Index (BMI). Results: The measured average dose rate was 92.2 ± 14 μSv&middot;h-1&middot;GBq-1 measured at one meter. Therefore, the dose rate constant of 92 μSv&middot;h-1&middot;GBq-1 proposed by the AAPM, TG-108 report is adequate for radiation protection purposes. There was no statistically significant correlation between the dose rate constant per unit activity and the patient body size metrics. We have measured a patient voiding factor of 0.89 ± 0.06 in comparison with 0.85 recommended by the AAPM. Conclusions: The presented data can be used by medical physicist working in nuclear medicine in formulating more accurate risk estimations resulting from radiation exposure from patients undergoing 18F-FDG PET/CT imaging. 展开更多
关键词 FDG MEASURED dose rate PATIENT VOIDING FACTOR PATIENT Attenuation FACTOR PATIENT Size
下载PDF
Assessment of Natural Radioactivity Levels and Radiation Dose Rate in Some Soil Samples from Historical Area, AL-RAKKAH, Saudi Arabia
18
作者 K. S. Al Mugren 《Natural Science》 2015年第5期238-247,共10页
This study aims to determine the activity concentrations of naturally occurring, technically-enhanced levels of radiation and the gamma absorbed dose rates in soil samples collected across the land scape of historical... This study aims to determine the activity concentrations of naturally occurring, technically-enhanced levels of radiation and the gamma absorbed dose rates in soil samples collected across the land scape of historical area which discovered in east of Saudi Arabia at 2009 G, Called AL- RAKKAH. By using an HPGe detector gamma-ray spectrometer, the activity concentrations of 226Ra 232Th and 40K were found in surface soil samples ranged from 17. 4 ± 1.2 Bq/kg to 28.3 ± 2.3 Bq/kg with an average value of 23 ± 1.6 Bq/kg, ranging from 1.1 ± 1.8 Bq/kg to 81.0 ± 1.7 Bq/kg with the average value 20 ± 1.4 Bq/kg and from 218 ± 11 Bq/kg to 255 ± 18 Bq/kg, with the mean value of 233 ± 12 Bq/kg respectively. The mean radium equivalent (Raeq) and outdoor radiation hazard index (Hex) for the area under study were determined as 69.52 Bq/kg and 0.16 respectively. The total absorbed dose rate due to three primordial radionuclides lies in the range of 17.74 - 72.24 nGy·h-1 with a mean of 32.69 nGy·h-1, which yields total annual effective dose of 0.37 mSv·y-1. The measured values are comparable with other global radioactivity measurements and are found to be safe for public and environment. The baseline data of this type will almost certainly be of importance in making estimations of population exposure. 展开更多
关键词 Soil GAMMA RAY Spectroscopy RADIOACTIVITY dose rate Alrakkah SAUDI ARABIA
下载PDF
Natural background radiation dose rate levels and incidences of reproductive abnormalities in high radiation area in Abeokuta, Southwestern Nigeria
19
作者 Nnamdi Norbert Jibiri John Bamidele Famodimu 《Natural Science》 2013年第11期1145-1153,共9页
A 10 y (1999-2008) birth records from two public and most accessible maternity hospitals locally in the city of Abeokuta, Nigeria were used to investigate the possible association of high outdoor gamma radiation expos... A 10 y (1999-2008) birth records from two public and most accessible maternity hospitals locally in the city of Abeokuta, Nigeria were used to investigate the possible association of high outdoor gamma radiation exposure on reproductive abnormalities in the city. From the delivery record of 11,923 births in the period under study, a total number of 485 incidences of reproductive abnormalities were recoded. These incidences comprise 228 multiple births, 190 still births and, 67 premature births. Using the available terrestrial gamma radiation exposure data for the city and different reproductive abnormalities, regression assessment was carried out using the Pearson Product Moment (PPM) correlation statistics. The correlation showed that the incidences of reproductive abnormalities and the radiation dose levels were negatively correlated and correlation coefficient values were very low for each of the reproductive abnormalities considered. Factors such as socio-economic potentials of patients, dietary and other environmental factors may have substantial influence on the reproductive defects in the area other than radiation. However, the present study has added to the radiometric information needed in understanding the relationship between natural outdoor radiation exposure and occurrences of reproductive abnormalities in areas of high radiation in the country. 展开更多
关键词 HIGH Background RADIATION Gamma RADIATION dose rates REPRODUCTIVE ABNORMALITIES Abeokuta NIGERIA
下载PDF
High Dose Rate (HDR) Brachytherapy for Mycosis Fungoides of the Wrist
20
作者 Gaurav Shukla Virginia Lockamy +4 位作者 James Keller Joya Sahu Barbara Pro Onder Alpdogan Wenyin Shi 《International Journal of Clinical Medicine》 2015年第3期154-157,共4页
Mycosis fungoides (MF) is the most common cutaneous T-cell lymphoma accounting for approximately half of all cutaneous T-cell lymphomas. Radiation therapy is an effective treatment for early stage MF and has been show... Mycosis fungoides (MF) is the most common cutaneous T-cell lymphoma accounting for approximately half of all cutaneous T-cell lymphomas. Radiation therapy is an effective treatment for early stage MF and has been shown to result in long-term disease-free intervals, with even curative potential. Radiation is also effective as palliative treatment for the localized lesion resistant to the topic or other treatments. In the current study, we report using high dose rate (HDR) radiation treatment for a patient with resistant mycosis fungoides involving the wrist. We report a convenient treatment with an ideal radiation dose distribution, and a excellent clinical outcome. 展开更多
关键词 MYCOSIS Fungoides CUTANEOUS T-CELL Lymphoma Radiation Therapy High dose rate (HDR)
下载PDF
上一页 1 2 83 下一页 到第
使用帮助 返回顶部