Based on the scheme of damped harmonic oscillator quantization and thermo-field dynamics (TFD), the quantization of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling is propo...Based on the scheme of damped harmonic oscillator quantization and thermo-field dynamics (TFD), the quantization of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling is proposed. The quantum fluctuations of charge and current of each loop in a squeezed vacuum state are studied in the thermal excitation case. It is shown that the fluctuations not only depend on circuit inherent parameters, but also rely on excitation quantum number and squeezing parameter. Moreover, due to the finite environmental temperature and damped resistance, the fluctuations increase with the temperature rising, and decay with time.展开更多
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th...In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.展开更多
In this paper, the authors discuss the upper bound for the genus of strong embeddings for 3-connected planar graphs on higher surfaces. It is shown that the problem of determining the upper bound for the strong embedd...In this paper, the authors discuss the upper bound for the genus of strong embeddings for 3-connected planar graphs on higher surfaces. It is shown that the problem of determining the upper bound for the strong embedding of 3-connected planar near-triangulations on higher non-orientable surfaces is NP-hard. As a corollary, a theorem of Richter, Seymour and Siran about the strong embedding of 3-connected planar graphs is generalized to orientable surface.展开更多
A near-triangulation is such a connected planar graph whose inner faces are all triangles but the outer face may be not. Let G be a near-triangulation of order n and C be an SCDC (small circuit double cover)[2] of G. ...A near-triangulation is such a connected planar graph whose inner faces are all triangles but the outer face may be not. Let G be a near-triangulation of order n and C be an SCDC (small circuit double cover)[2] of G. Let Then, C0 is said to he an equilibrium SCDC of G. In this paper, we show that if G is an outer planar graph, δ(C0)≤2, otherwiseδ(C0) ≤4.展开更多
X-band accelerators for multi-bunches are a new way to produce high luminosity and energy efficiency bunches. The smaller the size and the more bunches, the more severe is the wakefield in the X-band accelerators, unl...X-band accelerators for multi-bunches are a new way to produce high luminosity and energy efficiency bunches. The smaller the size and the more bunches, the more severe is the wakefield in the X-band accelerators, unless some means of strongly suppressing the transverse wakefield is adopted in the design of the accelerating structure. Here, the derivation of the wakefield function of the double circuit model and its application to the designed accelerator structure have been demonstrated.展开更多
基金Project supported by the Natural Science Foundation of Heze University of Shandong Province, China (Grant No XY05WL01), the University Experimental Technology Foundation of Shandong Province, China (Grant No S04W138), the Natural Science Foundation of Shandong Province, China (Grant No Y2004A09) and the National Natural Science Foundation of China (Grant No 10574060).
文摘Based on the scheme of damped harmonic oscillator quantization and thermo-field dynamics (TFD), the quantization of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling is proposed. The quantum fluctuations of charge and current of each loop in a squeezed vacuum state are studied in the thermal excitation case. It is shown that the fluctuations not only depend on circuit inherent parameters, but also rely on excitation quantum number and squeezing parameter. Moreover, due to the finite environmental temperature and damped resistance, the fluctuations increase with the temperature rising, and decay with time.
文摘In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.
文摘In this paper, the authors discuss the upper bound for the genus of strong embeddings for 3-connected planar graphs on higher surfaces. It is shown that the problem of determining the upper bound for the strong embedding of 3-connected planar near-triangulations on higher non-orientable surfaces is NP-hard. As a corollary, a theorem of Richter, Seymour and Siran about the strong embedding of 3-connected planar graphs is generalized to orientable surface.
基金Supported by the National Natural Science Foundation of China (69973001)
文摘A near-triangulation is such a connected planar graph whose inner faces are all triangles but the outer face may be not. Let G be a near-triangulation of order n and C be an SCDC (small circuit double cover)[2] of G. Let Then, C0 is said to he an equilibrium SCDC of G. In this paper, we show that if G is an outer planar graph, δ(C0)≤2, otherwiseδ(C0) ≤4.
文摘X-band accelerators for multi-bunches are a new way to produce high luminosity and energy efficiency bunches. The smaller the size and the more bunches, the more severe is the wakefield in the X-band accelerators, unless some means of strongly suppressing the transverse wakefield is adopted in the design of the accelerating structure. Here, the derivation of the wakefield function of the double circuit model and its application to the designed accelerator structure have been demonstrated.