期刊文献+
共找到1,669篇文章
< 1 2 84 >
每页显示 20 50 100
High Efficiency Double–Fed Induction Generator Applied to Wind Power Generator Technical Analyses
1
作者 Deng-Chern Sue 《Energy and Power Engineering》 2011年第3期253-261,共9页
High efficiency Double-Fed Induction Generator applies new power electronic technology, and utilizes vector control to fix the magnetic direction of the stator to the vertical axis. Adjusting the input current of roto... High efficiency Double-Fed Induction Generator applies new power electronic technology, and utilizes vector control to fix the magnetic direction of the stator to the vertical axis. Adjusting the input current of rotor via an inverter can separately control the cross axis and vertical axis current of real power and reactive power of a generator. Traditionally, rotating speed affects frequency and the output is unstable. This study concentrates on high efficiency Double-Fed Induction Generators and Traditional Generators from mathematic model to derive and control the characteristics simulation and comparison than get an output of high efficiency Double-Fed Industrial Generators. This study utilizes the simulation software MATLAB/Simulink to simulate the response characteristics of vector control of a Double-Fed Industrial Generator. The operating and control functions are better than those of a traditional generator. 展开更多
关键词 double-fed induction generator CUT-IN Speed PUSHOVER TORQUE STALL REGULATOR PITCH REGULATOR Inverter
下载PDF
An analytic electromagnetic calculation method for performance evolution of doubly fed induction generators for wind turbines 被引量:1
2
作者 张文娟 黄守道 +1 位作者 高剑 CHEN Zhe 《Journal of Central South University》 SCIE EI CAS 2013年第10期2763-2774,共12页
An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of D... An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of DFIG, the modeling for electromagnetic calculation of DFIG was proposed. The electromagnetic calculation of DFIG was divided into three steps: the magnetic flux calculation, parameters derivation and performance checks. For each step, the detailed numeric calculation formulas were all derived. Combining the calculation formulas, the whole electromagnetic calculation procedure was established, which consisted of three iterative calculation loops, including magnetic saturation coefficient, electromotive force and total output power. All of the electromagnetic and performance data of DIFG can be calculated conveniently by the established calculation procedure, which can be used to evaluate the new designed machine. A 1.5 MW DFIG designed by the proposed procedure was built, for which the whole type tests including no-load test, load test and temperature rising test were carried out. The test results have shown that the DFIG satisfies technical requirements and the test data fit well with the calculation results which prove the correctness of the presented calculation method. 展开更多
关键词 ELECTROMAGNETIC calculation doublY fed induction generator(dfig) wind TURBINE
下载PDF
High Voltage Ride-through Control Strategy of Doubly Fed Induction Wind Generators Based on Virtual Impedance 被引量:2
3
作者 XIE Zhen ZHANG Xing YANG Shuying SONG Haihua QU Tingyu 《中国电机工程学报》 EI CSCD 北大核心 2012年第27期I0001-I0001,共1页
关键词 双馈感应发电机 风力发电机组 高电压 虚拟阻抗 控制策略 电网干扰 异步 无功补偿装置
下载PDF
Effects of Wind Turbines Equipped with Doubly-fed Induction Generators on Distance Protection 被引量:1
4
作者 Hossein Kazemi KAREGAR Maryam KHODDAM 《电力系统自动化》 EI CSCD 北大核心 2012年第8期128-131,共4页
Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipp... Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied. 展开更多
关键词 距离保护 双馈异步发电机 风力发电机组 配备 可再生能源资源 双馈感应发电机 距离继电器 同步发电机
下载PDF
A New Approach to Calculate Parameters of Induction Generator with Double Windings
5
作者 刘长红 姚若萍 《Journal of Shanghai Jiaotong university(Science)》 EI 2005年第2期186-189,共4页
The accuracy prediction for the performance of an induction generator depends much on the parameters of the equivalent circuit. This paper presented a new way for calculating these parameters of induction generator wi... The accuracy prediction for the performance of an induction generator depends much on the parameters of the equivalent circuit. This paper presented a new way for calculating these parameters of induction generator with double windings. The method is based on 2D time-dependent magnetic field coupled with electric circuit. An application example of a 12-phase self-excited induction generator (SEIG) was provided to demonstrate the effectiveness of the presented approach. Some of the calculated results show good coincidence with the experiment values. 展开更多
关键词 equivalent parameters self-excited induction generators double windings FEM
下载PDF
Reactive Current Allocation and Control Strategies Improvement of Low Voltage Ride Though for Doubly Fed Induction Wind Turbine Generation System 被引量:36
6
作者 LI Hui FU Bo +2 位作者 YANG Chao ZHAO Bin TANG Xianhu 《中国电机工程学报》 EI CSCD 北大核心 2012年第22期I0004-I0004,22,共1页
为满足风电机组低电压穿越(low voltage ride through,LVRT)的测试要求及其电气模型一致性评估需要,提出考虑向电网注入无功电流的双馈风电机组LVRT的控制策略。在阐述风电机组LVRT测试要求及控制原理的基础上,推导双馈发电机(doubly... 为满足风电机组低电压穿越(low voltage ride through,LVRT)的测试要求及其电气模型一致性评估需要,提出考虑向电网注入无功电流的双馈风电机组LVRT的控制策略。在阐述风电机组LVRT测试要求及控制原理的基础上,推导双馈发电机(doubly fed induction generator,DFIG)定子侧及网侧变流器输出无功电流极限表达式,研究电网电压跌落深度和发电机总输出有功功率对其无功电流极限值的影响规律,进而提出DFIG在LVRT期间的无功电流分配算法和改进的有功、无功功率控制策略。最后,以某实际2 MW双馈风电机组为例,分别对风速为5和12 m/s、电网电压对称跌落至20%和50%工况下的LVRT运行性能进行仿真比较和样机测试。与传统LVRT控制方法的对比表明,所提改进控制策略能更好地满足风电机组LVRT的测试要求。样机测试结果进一步证明了改进控制策略和仿真模型的有效性。 展开更多
关键词 风力涡轮机 发电系统 控制策略 无功电流 分配算法 低电压 异步 双馈
下载PDF
Steady State Analysis of a Doubly Fed Induction Generator 被引量:3
7
作者 Ahmad M. Alkandari S. A. Soliman Mansour H. Abdel-Rahman 《Energy and Power Engineering》 2011年第4期393-400,共8页
In this paper, we present the steady state analysis of a double-fed induction generator (DFIG) adopted for wind power generation. The three-phase induction machine connected to the network, to work as a generator for ... In this paper, we present the steady state analysis of a double-fed induction generator (DFIG) adopted for wind power generation. The three-phase induction machine connected to the network, to work as a generator for wind farms, is excited on the rotor circuit by a slip-frequency current injected to the rotor, from an exciter mounted on the same shaft of the machine. The resulting rotating magnetic field rotates at synchronous speed;as such the generated power has a constant frequency independent of the shaft speed. Effects of the excitation voltage magnitude and phase angle on the active and reactive power are studied, when the machine runs at constant speed. It has been shown that by controlling the excitation voltage magnitude and phase angle would control the mode of operation of the machine;motor mode or generator mode. Furthermore, the effects of the shaft speed on the active and reactive power at constant excitation voltage magnitude and constant phase angle are also investigated. 展开更多
关键词 ASYNCHRONOUS Operation double FEED induction generator (dfig) wind Power
下载PDF
A Novel Grid Synchronization Control of Doubly-fed Induction Generator
8
作者 ZHAN Liang-yu JIN Xin-min ZHANG Lu 《电力电子技术》 CSCD 北大核心 2012年第4期38-42,共5页
The dynamic performance of doubly-fed induction generator(DFIG) before and after connection is analyzed based on corresponding mathematical models and transfer functions in decoupled vector control.The parameter tunin... The dynamic performance of doubly-fed induction generator(DFIG) before and after connection is analyzed based on corresponding mathematical models and transfer functions in decoupled vector control.The parameter tuning methods of rotor current regulator before and after connection are given.To reach same dynamic performance the parameters should take different values and be switched before and after connection.However on one hand the closing moment of stator contactor is difficult to get as the feedback signal is usually twenty millisecond delay or so.The delay in parameter switching will affect rotor current and torque dynamics during the delayed period after connection. On the other hand parameter switching is troublesome.Hence a synchronization control strategy without parameter switching is proposed and analyzed in detail,which has linear rising exciting current to avoid current overshooting. The dynamic performance of the proposed strategy is analyzed in frequency domain and implemented on a DFIG experimental platform subsequently.The proposed synchronization strategy is validated by experimental results. 展开更多
关键词 摘要 编辑部 编辑工作 读者
下载PDF
Control of Doubly Fed Induction Generator under Unbalanced Voltages for Reduction of Torque Pulsation
9
作者 S. Wangsathitwong S. Sirisumrannukul +1 位作者 S. Chatratana W. Deleroi 《Journal of Energy and Power Engineering》 2011年第3期243-251,共9页
The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is t... The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is the consequence of the interaction of stator and rotor currents of different sequences. This paper presents a control technique to reduce the effect of unbalanced voltages on the DFIG in wind energy conversion systems. The negative sequence stator voltage is derived from the unbalanced three phase stator voltages. The compensated rotor voltage in terms of the derived negative sequence stator voltage and slip which minimizes the negative stator and rotor currents is proposed. The results from the simulation of control system with steady state model and dynamic model of the DFIG show that additional control loop with compensated voltage can significantly reduce torque and reactive power pulsations. 展开更多
关键词 doubly fed induction generator (dfig unbalanced voltages symmetrical components.
下载PDF
Dynamic Couplingand Cooperative Control for Multi-paralleled Doubly Fed Induction Generator Wind Farms during Symmetrical Low Voltage Ride-through in a Weak Grid
10
作者 Lei Guan Jun Yao 《Protection and Control of Modern Power Systems》 SCIE EI 2024年第3期112-125,共14页
In multi-fed grid-connected systems,there are complex dynamic interactions between different pieces of equipment.Particularly in situations of weak-grid faults,the dynamic coupling between equipment becomes more prono... In multi-fed grid-connected systems,there are complex dynamic interactions between different pieces of equipment.Particularly in situations of weak-grid faults,the dynamic coupling between equipment becomes more pronounced.This may cause the system to experience small-signal instability during the fault steady-state.In this paper,multi-paralleled doubly fed induction generator(DFIG)-based wind farms(WFs)are taken as an example to study the dynamic coupling within a multi-fed system during fault steady-state of symmetrical low voltage ride-through(LVRT)in a weak grid.The analysis reveals that the dynamic coupling between WFs will introduce a damping shift to each WF.This inevitably affects the system’s dynamic stability and brings the risk of small-signal instability during fault steady-state in LVRT scenarios.Increasing the distance to fault location and fault severity will exacerbate the dynamic coupling between WFs.Because of the dynamic coupling,adjusting the control state of one WF will affect the stability of the remaining WFs in the system.Hence,a cooperative control strategy for multi-paralleled DFIG WFs is proposed to improve dynamic stability during LVRT.The analysis and the effectiveness of the proposed control strategy are verified by modal analysis and simu-lation. 展开更多
关键词 doubly fed induction generator(dfig) wind farms(WFs) dynamic stability low voltage ride through(LVRT) weak grid dynamic coupling
原文传递
Robust Optimal Framework for Doubly Fed Induction Generator with Uncertain Dynamics
11
作者 Yongfeng Lü Xiaowei Zhao Priyank Shah 《Protection and Control of Modern Power Systems》 SCIE EI 2024年第5期129-141,共13页
A robust optimal framework is designed herein to mitigate the oscillatory dynamics in a doubly fed induction generator(DFIG)even in the presence of network disturbances and input variation.To address uncertain dynamic... A robust optimal framework is designed herein to mitigate the oscillatory dynamics in a doubly fed induction generator(DFIG)even in the presence of network disturbances and input variation.To address uncertain dynamics,herein,a novel transformation formula is developed for a wind energy conversion system.An unscented Kalman filter is applied to estimate the un-measured internal states of the wind energy conversion system using terminal measurements.The detailed convergence and stability analyses of the presented framework are investigated to validate its effectiveness.Additionally,comparative modal analyses are carried out to demonstrate the improvement in the damping of critical low-frequency oscillatory modes using the presented framework.The simulation results demonstrate satisfactory performance under various operating scenarios,such as increasing and decreasing wind speed and varying the terminal voltage.The comparative performance is demonstrated to validate the effectiveness of the presented framework over that of the state-of-the-art frameworks. 展开更多
关键词 Optimal control power system renew-able energy sources wind energy conversion system doubly fed induction generator
原文传递
A Long-Range Generalized Predictive Control Algorithm for a DFIG Based Wind Energy System 被引量:1
12
作者 J.S.Solis-Chaves Lucas L.Rodrigues +1 位作者 C.M.Rocha-Osorio Alfeu J.Sguarezi Filho 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第5期1209-1219,共11页
This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based. This controller uses the state space equations t... This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based. This controller uses the state space equations that consider the rotor current and voltage as state and control variables, to execute the predictive control action. Therefore, the model of the plant must be transformed into two discrete transference functions, by means of an auto-regressive moving average model, in order to attain a discrete and decoupled controller, which makes it possible to treat it as two independent single-input single-output systems instead of a magnetic coupled multiple-input multiple-output system. For achieving that, a direct power control strategy is used, based on the past and future rotor currents and voltages estimation. The algorithm evaluates the rotor current predictors for a defined prediction horizon and computes the new rotor voltages that must be injected to controlling the stator active and reactive powers. To evaluate the controller performance, some simulations were made using Matlab/Simulink. Experimental tests were carried out with a small-scale prototype assuming normal operating conditions with constant and variable wind speed profiles. Finally, some conclusions respect to the dynamic performance of this new controller are summarized. 展开更多
关键词 Direct power CONTROL doublY-fed induction generator flux oriented CONTROL generalized PREDICTIVE CONTROL LONG-RANGE PREDICTIVE CONTROL wind energy systems
下载PDF
Analysis on Effect of Parameters of Different Wind Generator on Power Grid Transient Stability
13
作者 Zhi-wei Wen Li Ding Shi-en He 《Energy and Power Engineering》 2013年第4期363-367,共5页
To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different... To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different wind farm integration on grid typically in China has been presented. The influence of the variations of transient reactance, negative sequence reactance and rotary inertia on critical clearing time of power system transient stability is analyzed by time-domain simulation. Mixture operation of DFIG and PMSG to optimize the stability of system has been analyzed firstly. The digital simulation results show that doubly-fed induction wind turbines is a better choice to meet the requirement of system instability due to large wind farm integration in comparison with direct-drive PM synchronous wind turbines. With a rather large rotary inertia, the proper ratio of direct-drive PM synchronous wind turbines used in wind farm could be comprehensive planning by optimized the stability of system. Analysis of this paper should be provided as academic reference for improving design of wind farm system. 展开更多
关键词 wind FARM doublY-fed induction generator DIRECT-DRIVE PM SYNCHRONOUS generator Parameter
下载PDF
Research on multi-time scale doubly-fed wind turbine test system based on FPGA+CPU heterogeneous calculation
14
作者 Qing Mu Xing Zhang +3 位作者 Xiaoxin Zhou Xiaowei Fan Yingmei Liu Dongbo Pan 《Global Energy Interconnection》 2019年第1期7-18,共12页
As the proportion of renewable energy increases, the interaction between renewable energy devices and the grid continues to enhance. Therefore, the renewable energy dynamic test in a power system has become more and m... As the proportion of renewable energy increases, the interaction between renewable energy devices and the grid continues to enhance. Therefore, the renewable energy dynamic test in a power system has become more and more important. Traditional dynamic simulation systems and digital-analog hybrid simulation systems are difficult to compromise on the economy, flexibility and accuracy. A multi-time scale test system of doubly fed induction generator based on FPGA+ CPU heterogeneous calculation is proposed in this paper. The proposed test system is based on the ADPSS simulation platform. The power circuit part of the test system is setup up using the EMT(electromagnetic transient simulation) simulation, and the control part uses the actual physical devices. In order to realize the close-loop testing for the physical devices, the power circuit must be simulated in real-time. This paper proposes a multi-time scale simulation algorithm, in which the decoupling component divides the power circuit into a large time scale system and a small time scale system in order to reduce computing effort. This paper also proposes the FPGA+CPU heterogeneous computing architecture for implementing this multitime scale simulation. In FPGA, there is a complete small time-scale EMT engine, which support the flexibly circuit modeling with any topology. Finally, the test system is connected to an DFIG controller based on Labview to verify the feasibility of the test system. 展开更多
关键词 Renewable energy gen erati on doublY fed in duction generator ADPSS simulati on SYSTEM wind turbine test SYSTEM Multi-time scale FPGA+CPU
下载PDF
Small Signal Stability Analysis of DFIG Fed Wind Power System Using a Robust Fuzzy Logic Controller
15
作者 M. Panneer Selvam P. Prakasam 《Circuits and Systems》 2016年第4期390-401,共12页
This paper focuses on the small signal stability analysis of Doubly-Fed Induction Generator (DFIG) fed wind power system under three modes of operation. The system stability is affected by the influence of electromech... This paper focuses on the small signal stability analysis of Doubly-Fed Induction Generator (DFIG) fed wind power system under three modes of operation. The system stability is affected by the influence of electromechanical oscillations, which can be damped using Power System Stabilizer (PSS). A detailed modeling of DFIG fed wind system including controller has been carried out. The damping controller is designed using fuzzy logic to damp the oscillatory modes for stability. The robust performance of the system with controllers has been evaluated using eigen value analysis and time domain simulations under various disturbances and wind speeds. The effectiveness of the proposed fuzzy based PSS is compared with the performance of conventional PSS implemented in the wind system. 展开更多
关键词 doubly-fed induction generator (dfig) Conventional Power System Stabilizer (CPSS) Fuzzy Logic Based Power System Stabilizer (FPSS)
下载PDF
Robust nonlinear controller design of wind turbine with doubly fed induction generator by using Hamiltonian energy approach 被引量:1
16
作者 Bing WANG Yanping QIAN Yiming ZHANG 《控制理论与应用(英文版)》 EI CSCD 2013年第2期282-287,共6页
Based on Hamiltonian energy theory, this paper proposes a robust nonlinear controller for the wind turbine with doubly fed induction generator (DFIG), such that the closed-loop system can achieve its stability. Furt... Based on Hamiltonian energy theory, this paper proposes a robust nonlinear controller for the wind turbine with doubly fed induction generator (DFIG), such that the closed-loop system can achieve its stability. Furthermore, in the presence of disturbances, the closed-loop system is finite-gain L2 stable by the Hamiltonian controller. The Hamiltonian energy approach provides us a physical insight and gives a new way to the controller design. The simulation results illustrate that the proposed method is effective and has its advantage. 展开更多
关键词 Hamiltonian energy theory wind turbine doubly fed induction generator Robust control
原文传递
WIND POWER IMPACT ON TRANSIENT FAULT BEHAVIOR IN ELECTRICAL POWER GRID USING DOUBLY FED INDUCTION GENERATOR
17
作者 LATA GIDWANI H.P.TIWARI 《International Journal of Modeling, Simulation, and Scientific Computing》 EI 2012年第3期1-17,共17页
The amount of electrical energy produced by wind mills is constantly increasing.Nowadays detailed analyzes considering the impact of wind energy integration on the transmission system are required.The goal of this stu... The amount of electrical energy produced by wind mills is constantly increasing.Nowadays detailed analyzes considering the impact of wind energy integration on the transmission system are required.The goal of this study is to investigate the dynamic response of a wind turbine with doubly fed induction generator connected to the power system during grid disturbance.The current and future wind power situation is modeled as two cases and a transient fault is simulated.In order to analyze the impact of wind energy integration in electrical power grid,a power system model has been developed,integrated with wind turbine using doubly fed induction generator and transient analysis are performed.Here,an attempt has been made to compare the impact,in terms of voltages,currents,total harmonic distortion,etc.,of adding wind turbines into electrical power grid. 展开更多
关键词 doubly fed induction generator power grid transient fault wind power
原文传递
适应并离网模式切换的DFIG电磁暂态仿真建模
18
作者 于光耀 杨帮宇 +3 位作者 李振斌 崇志强 李惠玲 黄丽妍 《电网与清洁能源》 CSCD 北大核心 2024年第2期95-102,共8页
目前,常用的商业仿真软件中的双馈式感应发电机(double-fed Induction Generator,DFIG)模型通常不支持离网运行模式,难以实现风力发电系统由离网到并网的全过程电磁暂态仿真,对电力系统仿真分析工作带来极大不便。研究适应并离网模式切... 目前,常用的商业仿真软件中的双馈式感应发电机(double-fed Induction Generator,DFIG)模型通常不支持离网运行模式,难以实现风力发电系统由离网到并网的全过程电磁暂态仿真,对电力系统仿真分析工作带来极大不便。研究适应并离网模式切换的DFIG电磁暂态仿真建模方法。基于模块化思想分别对风力机、异步电机、变流器以及断路器进行建模,在系统组装形成DFIG风力发电系统电磁暂态仿真模型。提出了适应并离网模式切换的DFIG受控源等效电路模型和离散时间域实现方法,通过设计状态变量矩阵元素的截取和扩充算法实现了模型在并离网模式下的无缝衔接。在MATLAB/Simulink中搭建DFIG发电系统模型对所提方法和模型进行验证,仿真结果表明,所提建模方法能够很好地支持DFIG离网运行模式,实现DFIG由离网到并网的全过程电磁暂态仿真。 展开更多
关键词 双馈式感应发电机(dfig) 并离网切换 电磁暂态仿真 建模方法
下载PDF
基于硬件在环仿真的DFIG并网系统开环模式谐振风险及验证
19
作者 陈江 杜文娟 杨佳 《南方电网技术》 CSCD 北大核心 2024年第2期98-105,132,共9页
开环模式谐振理论是阐释风电并网引起的电力系统振荡机理的研究成果,其中基于平均模型的离线时域仿真结果可信度存疑。为提升开环模式谐振的工程指导可靠度,首先基于硬件在环仿真,组建了用于验证开环模式谐振的半实物实验平台;其次建立... 开环模式谐振理论是阐释风电并网引起的电力系统振荡机理的研究成果,其中基于平均模型的离线时域仿真结果可信度存疑。为提升开环模式谐振的工程指导可靠度,首先基于硬件在环仿真,组建了用于验证开环模式谐振的半实物实验平台;其次建立双馈风电场并网系统的小信号模型,提出开环模式分析通用方法评估系统振荡风险;最后以两个算例进行了开环模式谐振现象的分析与实验。得到结论:硬件在环仿真的结果符合开环模式分析的结果,在开环模式谐振条件下,系统稳定性下降。留数法可以较为准确地预测系统闭环模式,系统参数的合理整定可以减小开环模式谐振带来的影响。 展开更多
关键词 开环模式谐振 硬件在环仿真 双馈感应发电风电场 振荡风险 稳定性分析
下载PDF
计及风力发电机转速安全约束的DFIG一次调频模型预测控制策略
20
作者 周涛 张锋杨 +2 位作者 徐妍 王亚伦 纪子洋 《南京理工大学学报》 CAS CSCD 北大核心 2024年第2期155-164,共10页
针对传统方法控制双馈感应发电机(DFIG)的调频效果过于依赖参数整定的问题,该文提出了一种基于模型预测控制(MPC),计及转速安全约束的风力发电机参与一次调频控制策略。该方法结合风力发电机动力学模型与频率响应模型建立预测模型,通过... 针对传统方法控制双馈感应发电机(DFIG)的调频效果过于依赖参数整定的问题,该文提出了一种基于模型预测控制(MPC),计及转速安全约束的风力发电机参与一次调频控制策略。该方法结合风力发电机动力学模型与频率响应模型建立预测模型,通过线性回归方法变参考值将风力发电机转速的稳定性纳入考虑。相较于虚拟惯性控制等方法将系统频率偏差与转子动能直接关联,该文方法通过建立全新的预测模型,实时统筹考虑整个系统的状态信息,无需反复调整参数,在考虑转速安全性的同时兼顾全局性能。最后,通过实际算例分析验证了该文调频策略的有效性以及相对现有方法的优越性。 展开更多
关键词 双馈感应发电机 一次调频 频率响应模型 模型预测控制 转子动能控制 虚拟惯性控制 转速安全 线性回归
下载PDF
上一页 1 2 84 下一页 到第
使用帮助 返回顶部