A double reheat ultra-supercritical boiler is an important development direction for high-parameter and large-capacity coal-fired power plants due to its high thermal efficiency and environmental value.China has devel...A double reheat ultra-supercritical boiler is an important development direction for high-parameter and large-capacity coal-fired power plants due to its high thermal efficiency and environmental value.China has developed a 1000 MW double reheat ultra-supercritical boiler with steam parameters of 35 MPa at 605℃/613℃/613℃.Reasonable water wall design is one of the keys to safe and reliable operation of the boiler.In order to examine the thermal-hydraulic characteristics of the double reheat ultra-supercritical boiler,the water wall system was equivalent to a flow network comprising series-parallel circuits,linking circuits and pressure nodes,and a calculation model was built on account of the conservation equations of energy,momentum and mass.Through the iterative solving of nonlinear equations,the prediction parameters of the water wall at boiler maximum continue rate(BMCR),75%turbine heat-acceptance rate(THA)and 30%THA loads,including total pressure drops,flow distribution,outlet steam temperatures,fluid and metal temperatures were gotten.The results of calculation exhibit excellent thermal-hydraulic characteristics and substantiate the feasibility of the water wall design of the double reheat ultra-supercritical boiler.展开更多
This paper presented a coupled heat transfer model combining the combustion in the furnace and the ultra-supercritical(USC) heat transfer in the water wall tubes. The thermal analysis of the spiral water wall in a 100...This paper presented a coupled heat transfer model combining the combustion in the furnace and the ultra-supercritical(USC) heat transfer in the water wall tubes. The thermal analysis of the spiral water wall in a 1000 MW double reheat USC boiler was conducted by the coupled heat transfer simulations. The simulation results show that there are two peak heat flux regions on each wall of spiral water wall, where the primary combustion zone and burnt-out zone locate respectively. In the full load condition, the maximal heat flux of the primary combustion zone is close to 500 kW/m^2, which is higher than that in the conventional single reheat USC boilers. The heat flux along the furnace width presents a parabolic shape that the values in the furnace center are much higher than that in the corner regions. The distribution of water wall temperature has a perfect accordance with the heat flux distribution of the parabolic shape curves, which can illustrate the distribution of water wall temperature is mainly determined by heat flux on the water wall. The maximal water wall temperature occurs at the middle width of furnace wall and approaches 530°C, which can be allowed by the metal material of water wall tube 12Cr1MoVG. In the primary combustion zone, the wall temperatures in half load are almost close to the values in 75% load condition, caused by the heat transfer deterioration of the subcritical pressure fluid under the high heat flux condition. The simulation results in this study are beneficial to the better design and operational optimization for the double reheat USC boilers.展开更多
700°C double reheat advanced ultra-supercritical power generation technology is one of the most important development directions for the efficient and clean utilization of coal.To solve the great exergy loss prob...700°C double reheat advanced ultra-supercritical power generation technology is one of the most important development directions for the efficient and clean utilization of coal.To solve the great exergy loss problem caused by the high superheat degrees of regenerative steam extractions in 700°C double reheat advanced ultra-supercritical power generation system,two optimization systems are proposed in this paper.System 1 is integrated with the back pressure extraction steam turbine,and system 2 is simultaneously integrated with both the outside steam cooler and back pressure extraction steam turbine.The system performance models are built by the Ebsilon Professional software.The performances of optimized systems are analyzed by the unit consumption method.The off-design performances of optimization systems are analyzed.The results show that:the standard power generation coal consumption rates of optimization systems 1 and 2 are decreased by 1.88 g·(kW·h)^(–1),2.97 g·(kW·h)^(–1)compared with that of the 700°C reference system;the average superheat degrees of regenerative steam extractions of optimized systems 1 and 2 are decreased by 122.2°C,140.7°C(100%turbine heat acceptance condition),respectively.The comparison results also show that the performance of the optimized system 2 is better than those of the optimized system 1 and the 700°C reference system.The power generation standard coal consumption rate and the power generation efficiency of the optimized system 2 are about 232.08 g·(kW·h)^(–1)and 52.96%(100%turbine heat acceptance condition),respectively.展开更多
基金financially supported by the National Key Research&Development Program of China(2018YFB0604400)。
文摘A double reheat ultra-supercritical boiler is an important development direction for high-parameter and large-capacity coal-fired power plants due to its high thermal efficiency and environmental value.China has developed a 1000 MW double reheat ultra-supercritical boiler with steam parameters of 35 MPa at 605℃/613℃/613℃.Reasonable water wall design is one of the keys to safe and reliable operation of the boiler.In order to examine the thermal-hydraulic characteristics of the double reheat ultra-supercritical boiler,the water wall system was equivalent to a flow network comprising series-parallel circuits,linking circuits and pressure nodes,and a calculation model was built on account of the conservation equations of energy,momentum and mass.Through the iterative solving of nonlinear equations,the prediction parameters of the water wall at boiler maximum continue rate(BMCR),75%turbine heat-acceptance rate(THA)and 30%THA loads,including total pressure drops,flow distribution,outlet steam temperatures,fluid and metal temperatures were gotten.The results of calculation exhibit excellent thermal-hydraulic characteristics and substantiate the feasibility of the water wall design of the double reheat ultra-supercritical boiler.
基金the financial support of the National Key Research & Development Program of China (Grant No.:2017YFB0602102)
文摘This paper presented a coupled heat transfer model combining the combustion in the furnace and the ultra-supercritical(USC) heat transfer in the water wall tubes. The thermal analysis of the spiral water wall in a 1000 MW double reheat USC boiler was conducted by the coupled heat transfer simulations. The simulation results show that there are two peak heat flux regions on each wall of spiral water wall, where the primary combustion zone and burnt-out zone locate respectively. In the full load condition, the maximal heat flux of the primary combustion zone is close to 500 kW/m^2, which is higher than that in the conventional single reheat USC boilers. The heat flux along the furnace width presents a parabolic shape that the values in the furnace center are much higher than that in the corner regions. The distribution of water wall temperature has a perfect accordance with the heat flux distribution of the parabolic shape curves, which can illustrate the distribution of water wall temperature is mainly determined by heat flux on the water wall. The maximal water wall temperature occurs at the middle width of furnace wall and approaches 530°C, which can be allowed by the metal material of water wall tube 12Cr1MoVG. In the primary combustion zone, the wall temperatures in half load are almost close to the values in 75% load condition, caused by the heat transfer deterioration of the subcritical pressure fluid under the high heat flux condition. The simulation results in this study are beneficial to the better design and operational optimization for the double reheat USC boilers.
基金financially supported by National key research and development program of China(No.2017YFB0602101,2018YFB0604404)。
文摘700°C double reheat advanced ultra-supercritical power generation technology is one of the most important development directions for the efficient and clean utilization of coal.To solve the great exergy loss problem caused by the high superheat degrees of regenerative steam extractions in 700°C double reheat advanced ultra-supercritical power generation system,two optimization systems are proposed in this paper.System 1 is integrated with the back pressure extraction steam turbine,and system 2 is simultaneously integrated with both the outside steam cooler and back pressure extraction steam turbine.The system performance models are built by the Ebsilon Professional software.The performances of optimized systems are analyzed by the unit consumption method.The off-design performances of optimization systems are analyzed.The results show that:the standard power generation coal consumption rates of optimization systems 1 and 2 are decreased by 1.88 g·(kW·h)^(–1),2.97 g·(kW·h)^(–1)compared with that of the 700°C reference system;the average superheat degrees of regenerative steam extractions of optimized systems 1 and 2 are decreased by 122.2°C,140.7°C(100%turbine heat acceptance condition),respectively.The comparison results also show that the performance of the optimized system 2 is better than those of the optimized system 1 and the 700°C reference system.The power generation standard coal consumption rate and the power generation efficiency of the optimized system 2 are about 232.08 g·(kW·h)^(–1)and 52.96%(100%turbine heat acceptance condition),respectively.