Some double-circuit transmission lines are untransposed,which results in complex coupling relations between the parameters of the transmission lines.If the traditional modal transformation matrix is directly used to d...Some double-circuit transmission lines are untransposed,which results in complex coupling relations between the parameters of the transmission lines.If the traditional modal transformation matrix is directly used to decouple the parameters,it can lead to large errors in the decoupled modal parameter,errors which will be amplified in the fault location equation.Consequently,it makes the fault location results of the untransposed double-circuit transmission lines less accurate.Therefore,a new modal transformation method is needed to decou-ple the parameter matrix of untransposed double-circuit transmission lines and realize the fault location according to the decoupled modal parameter.By improving the basis of the Karrenbauer matrix,a modal transformation matrix suitable for decoupling parameters of untransposed double-circuit transmission lines is obtained.To address the dif-ficulties in solving the fault location equation of untransposed double-circuit transmission lines,a new fault location method based on an improved Karrenbauer matrix and the quantum-behaved particle swarm optimization(QPSO)algorithm is proposed.Firstly,the line parameter matrix is decomposed into identical and inverse sequence compo-nents using the identical-inverse sequence component transformation.The Karrenbauer matrix is then transformed to obtain the improved Karrenbauer matrix for untransposed double-circuit transmission lines and applied to identi-cal and inverse sequence components to solve the decoupled modal parameter.Secondly,based on the principle that voltage magnitudes at both ends are equal,the fault location equation is expressed using sequence compo-nents at each end,and the QPSO algorithm is introduced to solve the equation.Finally,the feasibility and accuracy of the proposed method are verified by PSCAD simulation.The simulation results fully demonstrate that the innova-tive improvement on the basis of the traditional modal transformation matrix in this paper can realize the modal transformation of the complex coupling parameters of the untransposed double-circuit transmission lines.It causes almost no errors in the decoupling process.The QPSO algorithm can also solve the fault location equation more accu-rately.The new fault location method can realize the accurate fault location of untransposed double-circuit transmis-sion lines.展开更多
Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term...Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term observation station close to the world’s first commercially operating 1000 kV UHV AC double-circuit transmission line in China.During six months of observations,the impact of RI was studied on the line during fog,drizzle,and light snow and rain.It was found that RI increases linearly with the natural logarithm of the precipitation intensity.The Levenberg-Marquardt algorithm(LMA)is employed to fit the RI value with the precipitation intensity.The reasonable distribution of RI in different foul weather is verified by one-sample K-S test.This test is seen as beneficial for further RI prediction based on statistical weather mode.展开更多
The amplitude of switching overvoltages is a key factor for designing the insulation of UHV equipment. The effect of different arresters needs to be studied, since installing arresters is an important way to suppress ...The amplitude of switching overvoltages is a key factor for designing the insulation of UHV equipment. The effect of different arresters needs to be studied, since installing arresters is an important way to suppress switching overvoltages in UHV transmission lines. Switching overvoltages on the 1000 kV Huainan-Huxi double-circuit transmission line were simulated for different operating modes and different arrester designs using the electromagnetic transient program PSCAD/EMTDC. With parallel resistors, the switching overvoltages are less than 1.70 p.u. (1.0 p.u.=1100×√ 2 /√3 kV). If the arrestors are better, the switching overvoltages can be reduced even lower to 1.55 p.u. Without parallel resistors, the arresters can reduce three-phase energizing overvoltages to 1.70 p.u, while the single-phase reclosing overvoltages still exceed the limit. The results show that the parallel resistors cannot be eliminated if the arresters are only installed at each end of the transmission line. Also, better quality arresters significantly lower the switching overvoltages.展开更多
基金funded by the National Natural Science Foundation of China(No.62363022,61663021,71763025,61861025)the Natural Science Foundation of Gansu Province(No.23JRRA886)the Gansu Provincial Department of Education:Industrial Support Plan Project(No.2023CYZC-35).
文摘Some double-circuit transmission lines are untransposed,which results in complex coupling relations between the parameters of the transmission lines.If the traditional modal transformation matrix is directly used to decouple the parameters,it can lead to large errors in the decoupled modal parameter,errors which will be amplified in the fault location equation.Consequently,it makes the fault location results of the untransposed double-circuit transmission lines less accurate.Therefore,a new modal transformation method is needed to decou-ple the parameter matrix of untransposed double-circuit transmission lines and realize the fault location according to the decoupled modal parameter.By improving the basis of the Karrenbauer matrix,a modal transformation matrix suitable for decoupling parameters of untransposed double-circuit transmission lines is obtained.To address the dif-ficulties in solving the fault location equation of untransposed double-circuit transmission lines,a new fault location method based on an improved Karrenbauer matrix and the quantum-behaved particle swarm optimization(QPSO)algorithm is proposed.Firstly,the line parameter matrix is decomposed into identical and inverse sequence compo-nents using the identical-inverse sequence component transformation.The Karrenbauer matrix is then transformed to obtain the improved Karrenbauer matrix for untransposed double-circuit transmission lines and applied to identi-cal and inverse sequence components to solve the decoupled modal parameter.Secondly,based on the principle that voltage magnitudes at both ends are equal,the fault location equation is expressed using sequence compo-nents at each end,and the QPSO algorithm is introduced to solve the equation.Finally,the feasibility and accuracy of the proposed method are verified by PSCAD simulation.The simulation results fully demonstrate that the innova-tive improvement on the basis of the traditional modal transformation matrix in this paper can realize the modal transformation of the complex coupling parameters of the untransposed double-circuit transmission lines.It causes almost no errors in the decoupling process.The QPSO algorithm can also solve the fault location equation more accu-rately.The new fault location method can realize the accurate fault location of untransposed double-circuit transmis-sion lines.
基金supported in part by the National Basic Research Program(973 Program)under Grant 2011CB209402-3the Science and Technology Project of the State Grid Corporation of China under Grant GY71-15-033.
文摘Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term observation station close to the world’s first commercially operating 1000 kV UHV AC double-circuit transmission line in China.During six months of observations,the impact of RI was studied on the line during fog,drizzle,and light snow and rain.It was found that RI increases linearly with the natural logarithm of the precipitation intensity.The Levenberg-Marquardt algorithm(LMA)is employed to fit the RI value with the precipitation intensity.The reasonable distribution of RI in different foul weather is verified by one-sample K-S test.This test is seen as beneficial for further RI prediction based on statistical weather mode.
基金Supported by the National Natural Science Foundation of China(No. 50737001)
文摘The amplitude of switching overvoltages is a key factor for designing the insulation of UHV equipment. The effect of different arresters needs to be studied, since installing arresters is an important way to suppress switching overvoltages in UHV transmission lines. Switching overvoltages on the 1000 kV Huainan-Huxi double-circuit transmission line were simulated for different operating modes and different arrester designs using the electromagnetic transient program PSCAD/EMTDC. With parallel resistors, the switching overvoltages are less than 1.70 p.u. (1.0 p.u.=1100×√ 2 /√3 kV). If the arrestors are better, the switching overvoltages can be reduced even lower to 1.55 p.u. Without parallel resistors, the arresters can reduce three-phase energizing overvoltages to 1.70 p.u, while the single-phase reclosing overvoltages still exceed the limit. The results show that the parallel resistors cannot be eliminated if the arresters are only installed at each end of the transmission line. Also, better quality arresters significantly lower the switching overvoltages.