期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Cyclic test and numerical study of seismic performance of precast segmental concrete double-columns
1
作者 ZOU Shuang WENLIUHAN Hei-sha +2 位作者 MAO Yong-ping YU Bi-peng ZHANG Chong-bin 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第8期2502-2512,共11页
The comparative research on the seismic performance of grouted sleeve connected pier(GS)and prestressed precast segmental concrete pier(PC)is mostly carried out by numerical simulation.In this study,the GS pier and th... The comparative research on the seismic performance of grouted sleeve connected pier(GS)and prestressed precast segmental concrete pier(PC)is mostly carried out by numerical simulation.In this study,the GS pier and the PC pier of the new railway project from Hetian to Ruoqiang are taken into consideration.Two kinds of 1/5-scale assembled double-column specimens are made,and the quasi-static tests are carried out.The overall seismic performance of the two spliced piers is studied,and compared in terms of failure mechanism,bearing capacity,ductility,stiffness and energy dissipation capacity.The results show that the failure modes of both GS pier and PC pier are characterized by bending.However,the specific failure location and form are different.The GS pier presents a complete hysteretic curve,large equivalent stiffness and strong energy dissipation capacity.The hysteretic area of the PC pier is small.However,it has good self-reset ability and quasi-static residual displacement.Finite element models are set up using DispBeamColumn fiber elements and ZeroLength elements.The models that are calibrated with the test data can effectively simulate the damage development under monotonic loading.The load−displacement curves are in good agreement with the backbone curves of the test results. 展开更多
关键词 pseudo static test seismic performance prestressed precast segmental concrete double-column piers steel sleeve connection precast concrete prestressed steel
下载PDF
ISOLATION AND PURIFICATION OF ALKALOIDS FROM PLUMULA NELUMBINIS BY DOUBLE-COLUMN ADSORPTION CHROMOTOGRAPHY
2
作者 ZHANG Jixiang GUO Jinsheng OU Lailiang 《Chinese Journal of Reactive Polymers》 2007年第1期119-124,共6页
The performance of adsorption and separation for liensinine, isoliensinine and neferine was studied by double-column adsorption chromatography using macroporous adsorption and cation exchange resins. The alkaloid extr... The performance of adsorption and separation for liensinine, isoliensinine and neferine was studied by double-column adsorption chromatography using macroporous adsorption and cation exchange resins. The alkaloid extract with 49.2% total contents by mass representing 10.6% liensinine, 10.6% isoliensinine and 28.0% neferine respectively was prepared by D72 cation exchange resins, in which most of the impurities were water-soluble alkaloids. Furthermore,the alkaloid extract with 82.6% total contents by mass containing 33.1%, 15.0% and 34.5% of the three adsorbates respectively was prepared by double-column adsorption chromatography using AKS-W macroporous adsorption and D72 cation exchange resins. As a result, the content of single and total alkaloids has been greatly increased by the double-column adsorption chromatography. 展开更多
关键词 double-column adsorption chromatography Macroporous adsorption resin Cation exchange resin Alkaloids from plumula nelumbinis.
下载PDF
Simulation research on the energy dissipation and shock absorption performance of a swing column device based on fuzzy control
3
作者 Zheng Yong Yuan Bo 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第4期987-998,共12页
Double-column bridge piers are prone to local damage during earthquakes,leading to the destruction of bridges.To improve the earthquake resistance of double-column bridge piers,a novel swing column device(SCD),consist... Double-column bridge piers are prone to local damage during earthquakes,leading to the destruction of bridges.To improve the earthquake resistance of double-column bridge piers,a novel swing column device(SCD),consisting of a magnetorheological(MR)damper,a current controller,and a swing column,was designed for the present work.To verify the seismic energy dissipation ability of the SCD,a lumped mass model for a double-column bridge pier with the SCD was established according to the low-order modeling method proposed by Steo.Furthermore,the motion equation of the double-column bridge pier with the SCD was established based on the D′Alembert principle and solved with the use of computational programming.It was found that the displacement response of the double-column bridge pier was effectively controlled by the SCD.However,due to rough current selection and a time delay,there is a significant overshoot of the bridge acceleration using SCD.Hence,to solve the overshoot phenomenon,a current controller was designed based on fuzzy logic theory.It was found that the SCD design based on fuzzy control provided an ideal shock absorption effect,while reducing the displacement and acceleration of the bridge pier by 36.43%‒40.63%and 30.06%‒33.6%,respectively. 展开更多
关键词 swing column device double-column bridge pier fuzzy control MR damper structural control low-element modeling method
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部