期刊文献+
共找到42,543篇文章
< 1 2 250 >
每页显示 20 50 100
Characterization of W Coating on Cu Substrate Prepared by Double-Glow Discharge
1
作者 张福斌 王正铎 +1 位作者 陈强 蔡惠平 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第1期71-74,共4页
In this study, tungsten (W) was coated on a copper (Cu) substrate by using doubleglow discharge technique using a pure W panel as the target and argon (Ar) as the discharge and sputtering gas. The crystal struct... In this study, tungsten (W) was coated on a copper (Cu) substrate by using doubleglow discharge technique using a pure W panel as the target and argon (Ar) as the discharge and sputtering gas. The crystal structure of the W coating was examined by X-ray diffraction (XRD). Scanning electron microscopy (SEM) was performed with cross-section images to investigate the penetration depth of W into the Cu body. Additionally, the properties of wearability resistance, corrosion resistance and mechanical strength of the W coated Cu matrix were also measured. It is concluded that in double-glow plasma, W coated Cu can be facilely prepared. It is noticed that the treatment temperature heavily dominates the properties of the W-Cu composite. 展开更多
关键词 double-glow discharge W-CU CHARACTERIZATIONS
下载PDF
Quantitative Analysis on Carbon Migration in Double-Glow Discharge Plasma Surface Alloying Process
2
作者 ZHANGZhen-xia WANGCong-zeng +1 位作者 ZHANGWen-quan SUXue-kuan 《材料热处理学报》 EI CAS CSCD 北大核心 2004年第05B期674-677,共4页
Carbon migration is of great significance in double-glow discharge plasma surface alloying process, but literature of quantitative analysis about carbon migration is relatively scarce. In this paper differential equat... Carbon migration is of great significance in double-glow discharge plasma surface alloying process, but literature of quantitative analysis about carbon migration is relatively scarce. In this paper differential equations of the carbon and metal concentration distribution were established. By means of differential equations carbon migration was described and a numerical solution was acquired. The computational results fit the experiment results quite well. 展开更多
关键词 双重辉光放电 等离子表面铸合 碳迁移 碳钢
下载PDF
Comparative analysis of single-crater parameters in ultrasonic-assisted and unassisted micro-EDM of Ti6Al4V using discharge plasma imaging
3
作者 Sohaib Raza Chandrakant Nirala 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2024年第2期11-24,共14页
Ultrasonic-assisted micro-electro-discharge machining(EDM)has the potential to enhance processing responses such as material removal rate(MRR)and surface finish.To understand the reasons for this enhancement,the physi... Ultrasonic-assisted micro-electro-discharge machining(EDM)has the potential to enhance processing responses such as material removal rate(MRR)and surface finish.To understand the reasons for this enhancement,the physical mechanisms responsible for the individual discharges and the craters that they form need to be explored.This work examines features of craters formed by single discharges at various parameter values in both conventional and ultrasonic-assistedEDM of Ti6Al4V.High-speed imaging of the plasma channel is performed,and data on the individual discharges are captured in real-time.A 2D axisymmetric model using finite element software is established to model crater formation.On the basis of simulation and experimental results,a comparative study is then carried out to examine the effects of ultrasonic vibrational assistance on crater geometry.For every set ofEDM parameters,the crater diameter and depth from a single discharge are found to be higher in ultrasonic-assistedEDM than in conventionalEDM.The improved crater geometry and the reduced bulge formation at the crater edges are attributed to the increased melt pool velocity and temperature predicted by the model. 展开更多
关键词 Ultrasonic vibration discharge crater Plasma diameter Single discharge
下载PDF
On the evolution and formation of discharge morphology in pulsed dielectric barrier discharge
4
作者 陈星宇 李孟琦 +3 位作者 王威逸 张权治 彭涛 熊紫兰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期101-113,共13页
The discharge morphology of pulsed dielectric barrier discharge(PDBD) plays important roles in its applications. Here, we systematically investigated the effects of the voltage amplitude,discharge gap, and O_(2)conten... The discharge morphology of pulsed dielectric barrier discharge(PDBD) plays important roles in its applications. Here, we systematically investigated the effects of the voltage amplitude,discharge gap, and O_(2)content on the PDBD morphology, and revealed the possible underlying mechanism of the U-shaped formation. First, the morphological evolution under different conditions was recorded. A unique U-shaped region appears in the middle edge region when the gap is larger than 2 mm, while the entire discharge region remains columnar under a 2 mm gap in He PDBD. The width of the discharge and the U-shaped region increase with the increase in voltage, and decrease with the increase of the gap and O_(2)content. To explain this phenomenon,a two-dimensional symmetric model was developed to simulate the spatiotemporal evolution of different species and calculate the electric thrust. The discharge morphology evolution directly corresponds to the excited-state atomic reduction process. The electric thrust on the charged particles mainly determines the reaction region and strongly influences the U-shaped formation.When the gap is less than 2 mm, the electric thrust is homogeneous throughout the entire region,resulting in a columnar shape. However, when the gap is larger than 2 mm or O_(2)is added, the electric thrust in the edge region becomes greater than that in the middle, leading to the U-shaped formation. Furthermore, in He PDBD, the charged particles generating electric thrust are mainly electrons and helium ions, while in He/O_(2)PDBD those that generate electric thrust at the outer edge of the electrode surface are mainly various oxygen-containing ions. 展开更多
关键词 low-temperature plasma dielectric barrier discharge discharge morphology particle distribution electric thrust
下载PDF
Experimental study on the effect of H_(2)O and O_(2) on the degradation of SF_(6) by pulsed dielectric barrier discharge
5
作者 李亚龙 万昆 +5 位作者 王宇非 张晓星 杨照迪 傅明利 卓然 王邸博 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期125-131,共7页
SF_(6) has excellent insulation performance and arc extinguishing ability,and is widely used in the power industry.However,its global warming potential is about 23,500 times that of C0_(2),it can exist stably in the a... SF_(6) has excellent insulation performance and arc extinguishing ability,and is widely used in the power industry.However,its global warming potential is about 23,500 times that of C0_(2),it can exist stably in the atmosphere,it is not easily degradable and is of great potential harm to the environment.Based on pulsed dielectric barrier discharge plasma technology,the effects of H_(2)O and 0_(2) on the degradation of SF_(6) were studied.Studies have shown that H_(2)O can effectively promote the decomposition of SF_(6) and improve its degradation rate and energy efficiency of degradation.Under the action of a pulse input voltage and input frequency of 15 kV and 15 kHz,respectively,when H_(2)O is added alone the effect of 1% H_(2)O is the best,and the rate and energy efficiency of degradation of SF_(6) reach their maximum values,which are 91.9% and 8.25 g kWh^(-1),respectively.The synergistic effect of H_(2)O and O_(2) on the degradation of SF_(6) was similar to that of H_(2)O.When the concentration of H_(2)O and O_(2) was 1%,the system obtained the best rate and energy efficiency of degradation,namely 89.7% and 8.05 g kWh~(-1),respectively.At the same time,different external gases exhibit different capabilities to regulate decomposition products.The addition of H_(2)O can effectively improve the selectivity of S0_(2).Under the synergistic effect of H_(2)O and O_(2),with increase in O_(2) concentration the degradation products gradually transformed into SO_(2)F_(2).From the perspective of harmless treatment of the degradation products of SF_(6),the addition of O_(2) during the SF_(6) degradation process should be avoided. 展开更多
关键词 SF_(6) pulsed dielectric barrier discharge DEGRADATION discharge gas
下载PDF
Predictors of Abnormal Vaginal Discharge among Women of Reproductive Age in Southeast Nigeria
6
作者 Jideuma Egwim Victor Dike +5 位作者 Hope Igbonagwam Nkechinyere Oke Uzoma Amajo Akuchi Okafor Angela Izegbune Ijedimma Okafor 《International Journal of Clinical Medicine》 CAS 2024年第7期240-256,共17页
Background: An abnormal vaginal discharge is a common complaint among women of reproductive age, and it can indicate serious conditions like pelvic inflammatory disease and cervical cancer. This study aimed to assess ... Background: An abnormal vaginal discharge is a common complaint among women of reproductive age, and it can indicate serious conditions like pelvic inflammatory disease and cervical cancer. This study aimed to assess the predictors of abnormal vaginal discharge in women of reproductive age group in Imo State, Southeast Nigeria. Methods: A cross-sectional study was conducted among 368 women of reproductive age group attending the clinic at Federal University Teaching Hospital Owerri, in Imo State, Nigeria. Respondents were recruited using a systematic sampling technique. Data were collected using a pre-tested interviewer-administered questionnaire. Multivariable analysis was performed to determine predictors of abnormal vaginal discharge. Statistical significance was set at p Results: The mean age of the respondents was 30 ±  4.5 years. Predictors of abnormal vaginal discharge were: age 36 - 45 years (OR: 4.5;95% C.I: 1.023 - 8.967, p = 0.041), being a student (OR: 2.4: 95% C.I: 1.496 - 7.336, p = 0.003), use of oral contraceptives (OR: 3.4;95% C.I: 1.068 - 6.932, p = 0.010), use of water cistern (OR: 4.7;C.I: 1.654 - 5.210, p = 0.028) anal hygiene practices (OR: 2.7;95% C.I: 1.142 - 4.809, p Conclusion: These findings suggest that targeted sexual and reproductive health interventions should be provided to reduce the risk of abnormal vaginal discharge in women of reproductive age group. 展开更多
关键词 PREDICTORS ABNORMAL VAGINAL discharge
下载PDF
Novel method for identifying the stages of discharge underwater based on impedance change characteristic
7
作者 高崇 康忠健 +3 位作者 龚大建 张扬 王玉芳 孙一鸣 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期133-145,共13页
It is difficult to determine the discharge stages in a fixed time of repetitive discharge underwater due to the arc formation process being susceptible to external environmental influences. This paper proposes a novel... It is difficult to determine the discharge stages in a fixed time of repetitive discharge underwater due to the arc formation process being susceptible to external environmental influences. This paper proposes a novel underwater discharge stage identification method based on the Strong Tracking Filter(STF) and impedance change characteristics. The time-varying equivalent circuit model of the discharge underwater is established based on the plasma theory analysis of the impedance change characteristics and mechanism of the discharge process. The STF is used to reduce the randomness of the impedance of repeated discharges underwater, and then the universal identification resistance data is obtained. Based on the resistance variation characteristics of the discriminating resistance of the pre-breakdown, main, and oscillatory discharge stages, the threshold values for determining the discharge stage are obtained. These include the threshold values for the resistance variation rate(K) and the moment(t).Experimental and error analysis results demonstrate the efficacy of this innovative method in discharge stage determination, with a maximum mean square deviation of Scrless than 1.761. 展开更多
关键词 discharge underwater discharge stage identification impedance characteristics strong tracking filter
下载PDF
Experimental study of the effect of gas discharge on ionic liquid electrospray
8
作者 石文 杨鹏飞 +1 位作者 宋培义 吴健 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期37-43,共7页
Ionic liquid electrospray(ILE) in an atmospheric environment is often accompanied by the gas discharge phenomenon. It interferes with the normal operation of the electrospray and the measurement of experimental parame... Ionic liquid electrospray(ILE) in an atmospheric environment is often accompanied by the gas discharge phenomenon. It interferes with the normal operation of the electrospray and the measurement of experimental parameters. In this study, electrospray experiments were conducted on the ionic liquid EMI-BF4. The observations revealed that the operating modes of the ionic liquid depend on the voltage polarity at high voltages. Additionally, a correspondence between the operating mode of ILE and the current signal in the circuit was established. The shape of the liquid cone formed at the needle tip bore a striking resemblance to the plume of corona discharge, suggesting that the motion trajectory of electrons influenced the curvature of the liquid cone. Steamer theory provided a clear explanation for the change in curvature as the voltage increased. 展开更多
关键词 ionic liquid ELECTROSPRAY Taylor cone jet corona discharge
下载PDF
Role of micro-Ca/In alloying in tailoring the microstructural characteristics and discharge performance of dilute Mg-Bi-Sn-based alloys as anodes for Mg-air batteries
9
作者 Fei-er Shangguan Wei-li Cheng +6 位作者 Yu-hang Chen Ze-qin Cui Hui Yu Hong-xia Wang Li-fei Wang Hang Li Hua Hou 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期251-266,共16页
The influence of micro-Ca/In alloying on the microstructural charac teristics,electrochemical behaviors and discharge properties of extruded dilute Mg-0.5Bi-0.5Sn-based(wt.%)alloys as anodes for Mg-air batteries are e... The influence of micro-Ca/In alloying on the microstructural charac teristics,electrochemical behaviors and discharge properties of extruded dilute Mg-0.5Bi-0.5Sn-based(wt.%)alloys as anodes for Mg-air batteries are evaluated.The grain size and texture intensity of the Mg-Bi-Sn-based alloys are significantly decreased after the Ca/In alloying,particularly for the In-containing alloy.Note that,in addition to nanoscale Mg_(3)Bi_(2)phase,a new microscale Mg_(2)Bi_(2)Ca phase forms in the Ca-containing alloy.The electrochemical test results demonstrate that Ca/In micro-alloying can enhance the electrochemical activity.Using In to alloy the Mg-Bi-Sn-based alloy is effective in restricting the cathodic hydrogen evolution(CHE)kinetics,leading to a low self-corrosion rate,while severe CHE occurred after Ca alloying.The micro-alloying of Ca/In to Mg-Bi-Sn-based alloy strongly deteriorates the compactness of discharge products film and mitigates the"chunk effect"(CE),hence the cell voltage,anodic efficiency as well as discharge capacity are greatly improved.The In-containing alloy exhibits outstanding discharge performance under the combined effect of the modified microstructure and discharge products,thus making it a potential anode material for primary Mg-air battery. 展开更多
关键词 Mg-air batteries Mg-Bi-Sn based alloys Electrochemical behaviors discharge properties
下载PDF
Discharge evolution law of debris flow based on a sharp bend physical modeling test
10
作者 LU Ming SUN Hao +3 位作者 LIU Jinfeng Abrar HUSSAIN SHANG Yuqi FU Hang 《Journal of Mountain Science》 SCIE CSCD 2024年第6期1904-1915,共12页
For the basins with debris flow development,its channel terrain exhibits a tortuous shape,which significantly restricts the movement of debris flows and leads to severe erosion effects on the concave bank.Therefore,th... For the basins with debris flow development,its channel terrain exhibits a tortuous shape,which significantly restricts the movement of debris flows and leads to severe erosion effects on the concave bank.Therefore,this study aims to analyze the shear force of debris flows within the bend channel.We established the relationship between the shear force and bend curvature through laboratory experiments.Under the long-term erosion by debris flows,the curvature radius of bends gradually increases,however,when this increasing trend reaches an equilibrium state with the intensity of debris flow discharge,there will be no significant change in curvature radius.In general,the activity pattern and discharges of debris flows would remain relatively stable.Hence,we can infer the magnitude of debris flow discharges from the terrain parameters of the bend channel. 展开更多
关键词 Debris flow discharge Erosion effect Bend channel Curvature radius
下载PDF
Performance of pulsed plasma thruster at low discharge energy
11
作者 李鸿俊 林泽豪 +3 位作者 胡浩俊 吴文东 陈爱虹 杜德扬 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期122-132,共11页
As the size of satellites scales down, low-power and compact propulsion systems such as the pulsed plasma thruster(PPT) are needed for stabilizing these miniature satellites in orbit. Most PPT systems are operated at ... As the size of satellites scales down, low-power and compact propulsion systems such as the pulsed plasma thruster(PPT) are needed for stabilizing these miniature satellites in orbit. Most PPT systems are operated at 2 J or more of discharge energy. In this work, the performance of a PPT with a side-fed, tongue-flared electrode configuration operated within a lower discharge energy range of 0.5-2.5 J has been investigated. Ablation and charring of the polytetrafluoroethylene propellant surface were analyzed through field-effect scanning electron microscopy imaging and energy-dispersive X-ray spectroscopy. When the discharge energy fell below 2 J, inconsistencies occurred in the specific impulse and the thrust efficiency due to the measurement of the low mass bit. At energy ≥2 J, the performance parameters are compared with other PPT systems of similar configuration and discussed in depth. 展开更多
关键词 pulsed plasma thruster low discharge energy performance parameters
下载PDF
Reconfigurable(4, 6^(2)) and(4, 8^(2)) Archimedean plasma photonic crystals in dielectric barrier discharge
12
作者 李蕊 王启晗 +5 位作者 刘富成 高匡雅 侯笑含 贾萌萌 李庆 范伟丽 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期70-78,共9页
Archimedean photonic crystal has become a research area of great interest due to its various unique properties. Here, we experimentally demonstrate the realization of reconfigurable(4, 6^(2))and(4, 8^(2)) Archimedean ... Archimedean photonic crystal has become a research area of great interest due to its various unique properties. Here, we experimentally demonstrate the realization of reconfigurable(4, 6^(2))and(4, 8^(2)) Archimedean plasma photonic crystals(APPCs) by use of dielectric barrier discharges in air. Dynamical control on both the macrostructures including the lattice symmetry and the crystal orientation, and the microstructures including the fine structures of scattering elements has been achieved. The formation mechanisms of APPCs are studied by time-resolved measurements together with numerical simulations. Large omnidirectional band gaps of APPCs have been obtained. The tunable topology of APPCs may offer new opportunities for fabricating multi-functional and highly-integrated microwave devices. 展开更多
关键词 Archimedean lattice plasma photonic crystals dielectric barrier discharge
下载PDF
Electron characteristics and dynamics in sub-millimeter pulsed atmospheric dielectric barrier discharge
13
作者 方骏林 张亚容 +4 位作者 卢陈梓 顾莉莉 徐少锋 郭颖 石建军 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期496-502,共7页
The discharge characteristics and mechanism of sub-millimeter pulsed dielectric barrier discharge in atmosphericpressure helium are investigated experimentally and theoretically, demonstrating that when the discharge ... The discharge characteristics and mechanism of sub-millimeter pulsed dielectric barrier discharge in atmosphericpressure helium are investigated experimentally and theoretically, demonstrating that when the discharge gap distance is reduced from 1.00 mm to 0.20 mm, the discharge ignition time is reduced to approximately 40 ns and discharge intensity is enhanced in terms of the discharge optical emission intensity and density of the plasma species,(energetic electrons with energy above 8.40 e V). The simulated results show that as the discharge gap distance is further reduced to 0.10 mm,the number of energetic electrons decreases, which is attributable to the contraction of plasma bulk regime and reduction of electron density in the discharge bulk. Conversely, the proportion of energetic electrons to the total electrons in the discharge monotonically increases as the discharge gap distance is reduced from 1.00 mm to 0.10 mm. It is proposed that a gap distance of 0.12 mm is optimal to achieve a high concentration and proportion of energetic electrons in sub-millimeter pulsed atmosphere dielectric barrier discharge. 展开更多
关键词 sub-millimeter pulsed discharge plasma simulation electron dynamics and sheath
下载PDF
Single flow treatment degradation of antibiotics in water using falling-film dielectric barrier discharge
14
作者 许志远 章程 +4 位作者 伍云健 黄邦斗 席登科 张晓星 邵涛 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期27-36,共10页
The environmental contamination caused by antibiotics is increasingly conspicuous due to their widespread manufacture and misuse. Plasma has been employed in recent years for the remediation of antibiotic pollution in... The environmental contamination caused by antibiotics is increasingly conspicuous due to their widespread manufacture and misuse. Plasma has been employed in recent years for the remediation of antibiotic pollution in the environment. In this work, a falling-film dielectric barrier discharge was used to degrade the antibiotic tetracycline(TC) in water. The reactor combined the gas-liquid discharge and active gas bubbling to improve the TC degradation performance. The discharge characteristics, chemical species’ concentration, and degradation rates at different parameters were systematically studied. Under the optimized conditions(working gas was pure oxygen, liquid flow rate was 100 mL/min, gas flow rate was 1 L/min,voltage was 20 kV, single treatment), TC was removed beyond 70% in a single flow treatment with an energy efficiency of 145 mg/(kW·h). The reactor design facilitated gas and liquid flow in the plasma area to produce more ozone in bubbles after a single flow under pure oxygen conditions, affording fast TC degradation. Furthermore, long-term stationary experiment indicated that long-lived active species can sustain the degradation of TC. Compared with other plasma treatment systems, this work offers a fast and efficient degradation method, showing significant potential in practical industrial applications. 展开更多
关键词 antibiotic degradation dielectric barrier discharge reactive species single flow treatment
下载PDF
Tailoring the microstructure of Mg-Al-Sn-RE alloy via friction stir processing and the impact on its electrochemical discharge behaviour as the anode for Mg-air battery
15
作者 Jingjing Liu Hao Hu +4 位作者 Tianqi Wu Jinpeng Chen Xusheng Yang Naiguang Wang Zhicong Shi 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第4期1554-1565,共12页
Constructing the magnesium alloy with fine grains,low density of dislocations,and weak crystal orientation is of crucial importance to enhance its comprehensive performance as the anode for Mg-air battery.However,this... Constructing the magnesium alloy with fine grains,low density of dislocations,and weak crystal orientation is of crucial importance to enhance its comprehensive performance as the anode for Mg-air battery.However,this unique microstructure can hardly be achieved with conventional plastic deformation such as rolling or extrusion.Herein,we tailor the microstructure of Mg-Al-Sn-RE alloy by using the friction stir processing,which obviously refines the grains without increasing dislocation density or strengthening crystal orientation.The Mg-air battery with the processed Mg-Al-Sn-RE alloy as the anode exhibits higher discharge voltages and capacities than that employing the untreated anode.Furthermore,the impact of friction stir processing on the electrochemical discharge behaviour of Mg-Al-Sn-RE anode and the corresponding mechanism are also analysed according to microstructure characterization and electrochemical response. 展开更多
关键词 Magnesium anode Electrochemical discharge behaviour Mg-air battery Friction stir processing
下载PDF
Effect of antenna helicity on discharge characteristics of helicon plasma under a divergent magnetic field
16
作者 孙萌 徐晓芳 +3 位作者 王陈文 尹贤轶 陈强 张海宝 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期50-59,共10页
The characteristics of the blue core phenomenon observed in a divergent magnetic field helicon plasma are investigated using two different helical antennas, namely right-handed and lefthanded helical antennas. The mod... The characteristics of the blue core phenomenon observed in a divergent magnetic field helicon plasma are investigated using two different helical antennas, namely right-handed and lefthanded helical antennas. The mode transition, discharge image, spatial profiles of plasma density and electron temperature are diagnosed using a Langmuir probe, a Nikon D90 camera,an intensified charge-coupled device camera and an optical emission spectrometer, respectively.The results demonstrated that the blue core phenomenon appeared in the upstream region of the discharge tube at a fixed magnetic field under both helical antennas. However, it is more likely to appear in a right-handed helical antenna, in which the plasma density and ionization rate of the helicon plasma are higher. The spatial profiles of the plasma density and electron temperature are also different in both axial and radial directions for these two kinds of helical antenna. The wavelength calculated based on the dispersion relation of the bounded whistler wave is consistent with the order of magnitude of plasma length. It is proved that the helicon plasma is part of the wave mode discharge mechanism. 展开更多
关键词 helicon plasma non-uniform magnetic field helical antenna blue core discharge mechanism
下载PDF
Machine learning for parameters diagnosis of spark discharge by electro-acoustic signal
17
作者 熊俊 卢诗宇 +3 位作者 刘晓明 周文俊 查晓明 裴学凯 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期64-72,共9页
Discharge plasma parameter measurement is a key focus in low-temperature plasma research.Traditional diagnostics often require costly equipment,whereas electro-acoustic signals provide a rich,non-invasive,and less com... Discharge plasma parameter measurement is a key focus in low-temperature plasma research.Traditional diagnostics often require costly equipment,whereas electro-acoustic signals provide a rich,non-invasive,and less complex source of discharge information.This study harnesses machine learning to decode these signals.It establishes links between electro-acoustic signals and gas discharge parameters,such as power and distance,thus streamlining the prediction process.By building a spark discharge platform to collect electro-acoustic signals and implementing a series of acoustic signal processing techniques,the Mel-Frequency Cepstral Coefficients(MFCCs)of the acoustic signals are extracted to construct the predictors.Three machine learning models(Linear Regression,k-Nearest Neighbors,and Random Forest)are introduced and applied to the predictors to achieve real-time rapid diagnostic measurement of typical spark discharge power and discharge distance.All models display impressive performance in prediction precision and fitting abilities.Among them,the k-Nearest Neighbors model shows the best performance on discharge power prediction with the lowest mean square error(MSE=0.00571)and the highest R-squared value(R^(2)=0.93877).The experimental results show that the relationship between the electro-acoustic signal and the gas discharge power and distance can be effectively constructed based on the machine learning algorithm,which provides a new idea and basis for the online monitoring and real-time diagnosis of plasma parameters. 展开更多
关键词 discharge plasma plasma real-time diagnosis electro-acoustic signal machine learning acoustic signature
下载PDF
Effect of continuous nursing on rehabilitation of older patients with joint replacement after discharge
18
作者 Xiao-Yan Qi Hong-Yan Zhou Yu-Hong Xing 《World Journal of Clinical Cases》 SCIE 2024年第21期4558-4565,共8页
BACKGROUND Joint replacement is a common treatment for older patients with high incidences of hip joint diseases.However,postoperative recovery is slow and complications are common,which reduces surgical effectiveness... BACKGROUND Joint replacement is a common treatment for older patients with high incidences of hip joint diseases.However,postoperative recovery is slow and complications are common,which reduces surgical effectiveness.Therefore,patients require long-term,high-quality,and effective nursing interventions to promote rehabilitation.Continuity of care has been used successfully in other diseases;however,little research has been conducted on older patients who have undergone hip replacement.AIM To explore the clinical effect of continuous nursing on rehabilitation after discharge of older individuals who have undergone joint replacement.METHODS A retrospective analysis was performed on the clinical data of 113 elderly patients.Patients receiving routine nursing were included in the convention group(n=60),and those receiving continuous nursing,according to various methods,were included in the continuation group(n=53).Harris score,short form 36(SF-36)score,complication rate,and readmission rate were compared between the convention and continuation groups.RESULTS After discharge,Harris and SF-36 scores of the continuation group were higher than those of the convention group.The Harris and SF-36 scores of the two groups showed an increasing trend with time,and there was an interaction effect between group and time(Harris score:F_(intergroup effect)=376.500,F_(time effect)=20.090,Finteraction effect=4.824;SF-36 score:F_(intergroup effect)=236.200,Ftime effect=16.710,Finteraction effect=5.584;all P<0.05).Furthermore,the total complication and readmission rates in the continuation group were lower(P<0.05).CONCLUSION Continuous nursing could significantly improve hip function and quality of life in older patients after joint replacement and reduce the incidence of complications and readmission rates. 展开更多
关键词 Continuous nursing discharge Older adults Joint replacement REHABILITATION EFFECT
下载PDF
A Clinical Study to Assess the Effectiveness of Oral Combination Kit Therapy in Syndromic Management of Abnormal Vaginal Discharge (FEMINE Study) in Kinshasa, Democratic Republic of Congo
19
作者 Feruzi Michel Mangala Muela Andy Mbangama +10 位作者 Di-Mosi-Nkoy Roger Wumba Ambis Joëlle Lumaya Nkongolo Freddy Muamba Tshitadi Jean Mukendi Ndombasi Neilda Lemba Otem Christian Ndesanzim Nkashama Bienvenu Kazadi Banza Jesual Lotoy Umba Adrien Tandu Mushengezi Dieudonné Sengeyi Mwimba Roger Mbungu 《Open Journal of Obstetrics and Gynecology》 2024年第1期193-208,共16页
Background: Vaginal discharge is one of most common and nagging problems that women face. About 20% - 25% of women who visit gynecology department complain of vaginal discharge and leucorrhoea. An orally administered ... Background: Vaginal discharge is one of most common and nagging problems that women face. About 20% - 25% of women who visit gynecology department complain of vaginal discharge and leucorrhoea. An orally administered combination kit, containing 2 g secnidazole, 1 g azithromycin and 150 mg fluconazole (Azimyn FS Kit), has been successfully evaluated in clinical trials and used in several countries for management syndromic vaginal discharge due to infections. Methods: This is a longitudinal study which aimed to verify the clinical efficacy of the combined oral kit containing secnidazole, azithromycin and fluconazole (Azimyn FS Kit<sup><sup>®</sup></sup>) in the syndromic treatment of abnormal vaginal discharge in patients received in outpatient consultations in Kinshasa/DR Congo from March to September 2023. Results: Majority of patients had whitish vaginal discharge (51.6%) of average abundance (56.2%), accompanied by pruritus in 72.1% of cases, and dyspareunia in 23.5% of cases and hypogastralgia in 40.2% of cases. One week after treatment with the Azimyn FS<sup><sup>®</sup></sup> combined kit, at the greatest majority of patients (97.3%), abnormal vaginal discharge had decreased by more than 50% (84.1%). Two weeks after treatment with the Azimyn FS<sup><sup>®</sup></sup> combined kit, almost all patients (97.3%) no longer had abnormal vaginal discharge which had completely disappeared. Conclusion: A single dose of secnidazole, azithromycin and fluconazole in the form of an oral combi-kit (Azimyn FS Kit) has shown excellent therapeutic effectiveness in the syndromic treatment of abnormal vaginal discharge wherein patients were treated without diagnostic confirmation. 展开更多
关键词 Oral Combination Kit Therapy Syndromic Management Abnormal Vaginal discharge
下载PDF
Phase field model for electric-thermal coupled discharge breakdown of polyimide nanocomposites under high frequency electrical stress
20
作者 韩智云 李庆民 +3 位作者 李俊科 王梦溪 任瀚文 邹亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期114-124,共11页
In contrast to conventional transformers, power electronic transformers, as an integral component of new energy power system, are often subjected to high-frequency and transient electrical stresses, leading to heighte... In contrast to conventional transformers, power electronic transformers, as an integral component of new energy power system, are often subjected to high-frequency and transient electrical stresses, leading to heightened concerns regarding insulation failures. Meanwhile, the underlying mechanism behind discharge breakdown failure and nanofiller enhancement under high-frequency electrical stress remains unclear. An electric-thermal coupled discharge breakdown phase field model was constructed to study the evolution of the breakdown path in polyimide nanocomposite insulation subjected to high-frequency stress. The investigation focused on analyzing the effect of various factors, including frequency, temperature, and nanofiller shape, on the breakdown path of Polyimide(PI) composites. Additionally, it elucidated the enhancement mechanism of nano-modified composite insulation at the mesoscopic scale. The results indicated that with increasing frequency and temperature, the discharge breakdown path demonstrates accelerated development, accompanied by a gradual dominance of Joule heat energy. This enhancement is attributed to the dispersed electric field distribution and the hindering effect of the nanosheets. The research findings offer a theoretical foundation and methodological framework to inform the optimal design and performance management of new insulating materials utilized in high-frequency power equipment. 展开更多
关键词 dielectric discharge breakdown high frequency power electronic transformer polyimide nanocomposites phase field model
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部