Shrinkage cavity may be detrimental to mechanical performances of casting parts.As a consequence,design engineers often use overly large safety factors in many designs due to insufficient understanding of quantitative...Shrinkage cavity may be detrimental to mechanical performances of casting parts.As a consequence,design engineers often use overly large safety factors in many designs due to insufficient understanding of quantitative effects of shrinkage cavity defects.In this paper,process of Al alloy wheel impact test was computationally analyzed for both the wheel models with and without shrinkage cavity defects.Based on shrinkage cavity data obtained from industrial CT (Computerized Tomography),the shrinkage cavity defects were modeled with SSM (Shape Simplification Method),which reconstructs shrinkage cavity defects to hollow spheroid primitives.After the impact simulation was conducted,the results show that under impact test condition,the wheel considering shrinkage cavity defects may fracture while the sound-assumed wheel may not.展开更多
The formation of cavities in silicon carbide is vitally useful to“smart-cut”and metal gettering in semiconductor industry.In this study,cavities and extended defects formed in helium(He)ions implanted 6H-SiC at room...The formation of cavities in silicon carbide is vitally useful to“smart-cut”and metal gettering in semiconductor industry.In this study,cavities and extended defects formed in helium(He)ions implanted 6H-SiC at room temperature(RT)and 750℃ followed by annealing at 1500℃are investigated by a combination of transmission electron microscopy and high-resolution electron microscopy.The observed cavities and extended defects are related to the implantation temperature.Heterogeneously distributed cavities and extended defects are observed in the helium-implanted 6H-SiC at RT,while homogeneously distributed cavities and extended defects are formed after He-implanted 6H-SiC at 750℃.The possible reasons are discussed.展开更多
Point defect states in two-dimensional phononic crystal of a hollow mercury cylinder in a water host are studied. An improved plane expansion method combined with the supercell technique is used to calculate the band ...Point defect states in two-dimensional phononic crystal of a hollow mercury cylinder in a water host are studied. An improved plane expansion method combined with the supercell technique is used to calculate the band gaps and the pressure distribution at the defect position. The sonic pressure of defect modes shows that the waves are localized at or near the defect. As the filing fraction increases, more defect modes appear in the band gaps.展开更多
The shrinkage defect of a ductile iron casting is attributed to the volume variations occurring in solidification, which consist of liquid contraction, solidification shrinkage, graphitization expansion, and mold cavi...The shrinkage defect of a ductile iron casting is attributed to the volume variations occurring in solidification, which consist of liquid contraction, solidification shrinkage, graphitization expansion, and mold cavity enlargement. Based on this understanding, a mathematical model for predicting the shrinkage defect of the casting is developed, in which the volume variations of the casting in soli- dification are numerically simulated, especially, the mold cavity enlargement is quantitatively calculated. Moreover, the reliability of the model is verified in production and experiment.展开更多
Light propagation through a channel filter based on two-dimensional photonic crystals with elliptical-rod defects is studied by the finite-difference time-domain method. Shape alteration of the defects from the usual ...Light propagation through a channel filter based on two-dimensional photonic crystals with elliptical-rod defects is studied by the finite-difference time-domain method. Shape alteration of the defects from the usual circle to an ellipse offers a powerful approach to engineer the resonant frequency of channel filters. It is found that the resonant frequency can be flexibly adjusted by just changing the orientation angle of the elliptical defects. The sensitivity of the resonant wavelength to the alteration of the oval rods' shape is also studied. This kind of multi-channel filter is very suitable for systems requiring a large number of output channel filters.展开更多
文摘Shrinkage cavity may be detrimental to mechanical performances of casting parts.As a consequence,design engineers often use overly large safety factors in many designs due to insufficient understanding of quantitative effects of shrinkage cavity defects.In this paper,process of Al alloy wheel impact test was computationally analyzed for both the wheel models with and without shrinkage cavity defects.Based on shrinkage cavity data obtained from industrial CT (Computerized Tomography),the shrinkage cavity defects were modeled with SSM (Shape Simplification Method),which reconstructs shrinkage cavity defects to hollow spheroid primitives.After the impact simulation was conducted,the results show that under impact test condition,the wheel considering shrinkage cavity defects may fracture while the sound-assumed wheel may not.
基金Project supported by the National Natural Science Foundation of China(Grant No.U1832133)the Doctor Research Foundation of Southwest University of Science and Technology,China(Grant No.18zx7141).
文摘The formation of cavities in silicon carbide is vitally useful to“smart-cut”and metal gettering in semiconductor industry.In this study,cavities and extended defects formed in helium(He)ions implanted 6H-SiC at room temperature(RT)and 750℃ followed by annealing at 1500℃are investigated by a combination of transmission electron microscopy and high-resolution electron microscopy.The observed cavities and extended defects are related to the implantation temperature.Heterogeneously distributed cavities and extended defects are observed in the helium-implanted 6H-SiC at RT,while homogeneously distributed cavities and extended defects are formed after He-implanted 6H-SiC at 750℃.The possible reasons are discussed.
基金Project supported by the National Natural Science Foundation of China (Grant No. 10864009)the Natural Science Foundation of Yunnan Province,China (Grant No. 2008CD109)the State Key Program of the National Natural Science of China (Grant No. 50734007)
文摘Point defect states in two-dimensional phononic crystal of a hollow mercury cylinder in a water host are studied. An improved plane expansion method combined with the supercell technique is used to calculate the band gaps and the pressure distribution at the defect position. The sonic pressure of defect modes shows that the waves are localized at or near the defect. As the filing fraction increases, more defect modes appear in the band gaps.
文摘The shrinkage defect of a ductile iron casting is attributed to the volume variations occurring in solidification, which consist of liquid contraction, solidification shrinkage, graphitization expansion, and mold cavity enlargement. Based on this understanding, a mathematical model for predicting the shrinkage defect of the casting is developed, in which the volume variations of the casting in soli- dification are numerically simulated, especially, the mold cavity enlargement is quantitatively calculated. Moreover, the reliability of the model is verified in production and experiment.
基金supported by the Research Foundation of the State Ethnic Affairs Commission of People’s Republic of China (Grant No. 10ZY05)the National Natural Science Foundation of China (Grant Nos. 10904176 and 11004169)the "985 Project"and the "211 Project" of the Ministry of Education of China
文摘Light propagation through a channel filter based on two-dimensional photonic crystals with elliptical-rod defects is studied by the finite-difference time-domain method. Shape alteration of the defects from the usual circle to an ellipse offers a powerful approach to engineer the resonant frequency of channel filters. It is found that the resonant frequency can be flexibly adjusted by just changing the orientation angle of the elliptical defects. The sensitivity of the resonant wavelength to the alteration of the oval rods' shape is also studied. This kind of multi-channel filter is very suitable for systems requiring a large number of output channel filters.