期刊文献+
共找到22,121篇文章
< 1 2 250 >
每页显示 20 50 100
Intelligent Energy Utilization Analysis Using IUA-SMD Model Based Optimization Technique for Smart Metering Data
1
作者 K.Rama Devi V.Srinivasan +1 位作者 G.Clara Barathi Priyadharshini J.Gokulapriya 《Journal of Harbin Institute of Technology(New Series)》 CAS 2024年第1期90-98,共9页
Smart metering has gained considerable attention as a research focus due to its reliability and energy-efficient nature compared to traditional electromechanical metering systems. Existing methods primarily focus on d... Smart metering has gained considerable attention as a research focus due to its reliability and energy-efficient nature compared to traditional electromechanical metering systems. Existing methods primarily focus on data management,rather than emphasizing efficiency. Accurate prediction of electricity consumption is crucial for enabling intelligent grid operations,including resource planning and demandsupply balancing. Smart metering solutions offer users the benefits of effectively interpreting their energy utilization and optimizing costs. Motivated by this,this paper presents an Intelligent Energy Utilization Analysis using Smart Metering Data(IUA-SMD)model to determine energy consumption patterns. The proposed IUA-SMD model comprises three major processes:data Pre-processing,feature extraction,and classification,with parameter optimization. We employ the extreme learning machine(ELM)based classification approach within the IUA-SMD model to derive optimal energy utilization labels. Additionally,we apply the shell game optimization(SGO)algorithm to enhance the classification efficiency of the ELM by optimizing its parameters. The effectiveness of the IUA-SMD model is evaluated using an extensive dataset of smart metering data,and the results are analyzed in terms of accuracy and mean square error(MSE). The proposed model demonstrates superior performance,achieving a maximum accuracy of65.917% and a minimum MSE of0.096. These results highlight the potential of the IUA-SMD model for enabling efficient energy utilization through intelligent analysis of smart metering data. 展开更多
关键词 electricity consumption predictive model data analytics smart metering machine learning
下载PDF
Controlling Congestion in Al-Seeb Highway Using Ramp Metering (Case Study)
2
作者 Zahra Al Habsi Mohamed Al Qanaii 《Journal of Transportation Technologies》 2024年第3期308-335,共28页
This paper represents a case study of traffic congestion within a section on Al Seeb Street highway due to the on-ramp merging of vehicles that causes a bottleneck in the mainline road. It studies the efficiency of in... This paper represents a case study of traffic congestion within a section on Al Seeb Street highway due to the on-ramp merging of vehicles that causes a bottleneck in the mainline road. It studies the efficiency of installing ramp metering within a ramp within the selected study zone. This is done by simulating the collected data using Vissim software by drawing three one-hour-long scenarios;the first scenario reflects the data collected for 30 minutes duration and is used as a base scenario to draw the other two scenarios, which are reflected as factored-up scenarios to create a situation observed in the early morning in the study zone at 6:00-7:00 in which slowing down of speeds exist, and breakdown is raised in working days. The two factoring-up scenarios were as follows: one without ramp metering and the other without ramp metering. Each scenario was calibrated and run five times with random seeds, and then the average was considered. The simulation examines the ability of RM to smooth traffic in mainline and reduce queuing on on-ramp roads within the selected study zone by comparing the performance of the network for the scenarios and comparing them in terms of the overall delays, number of stops and the average speeds for the vehicles within the mainline. The results showed a good performance reflected by the scenario with ramp metering with a reduction of the overall delay, a decrease in stops number and an increase of the average speed were achieved. For the base scenario, a visualization (video extracted from Vissim software) was extracted, showing no need to install RM with an associated table showing a number of stops equal to zero with an average speed of 102.74 km/h and a total delay of 6045 seconds. For the second scenario with no RM, a visualization was extracted showing a slowing down of speeds for vehicles within the mainline while vehicles merging from the on-ramp and need to be controlled with a table showing a number of stops equal to 16 and an average speed equal to 58 km/h and a total delay of 916,874 seconds. For the third scenario with RM, a visualization was extracted showing good control of the second scenario with a table showing the number of stops equal to 6, an average speed equal to 61 km/h and a total delay equal to 484,466 seconds. Ten literatures in regard to this study have been reviewed. The data collected are quantitative, which are collected using an indirect manual counting method and then the data is used to feed the software for simulation. 展开更多
关键词 On-Ramp Merge Ramp-metering Vissim Simulation
下载PDF
A Fault Diagnosis Method for Smart Meters via Two-layer Stacking Ensemble Optimization and Data Augmentation
3
作者 Leijiao Ge Tianshuo Du +3 位作者 Zhengyang Xu Luyang Hou Jun Yan Yuanliang Li 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第4期1272-1284,共13页
The accurate identification of smart meter(SM)fault types is crucial for enhancing the efficiency of operationand maintenance(O&M)and the reliability of power collectionsystems.However,the intelligent classificati... The accurate identification of smart meter(SM)fault types is crucial for enhancing the efficiency of operationand maintenance(O&M)and the reliability of power collectionsystems.However,the intelligent classification of SM fault typesfaces significant challenges owing to the complexity of featuresand the imbalance between fault categories.To address these issues,this study presents a fault diagnosis method for SM incorporatingthree distinct modules.The first module employs acombination of standardization,data imputation,and featureextraction to enhance the data quality,thereby facilitating improvedtraining and learning by the classifiers.To enhance theclassification performance,the data imputation method considersfeature correlation measurement and sequential imputation,and the feature extractor utilizes the discriminative enhancedsparse autoencoder.To tackle the interclass imbalance of datawith discrete and continuous features,the second module introducesan assisted classifier generative adversarial network,which includes a discrete feature generation module.Finally,anovel Stacking ensemble classifier for SM fault diagnosis is developed.In contrast to previous studies,we construct a two-layerheuristic optimization framework to address the synchronousdynamic optimization problem of the combinations and hyperparametersof the Stacking ensemble classifier,enabling betterhandling of complex classification tasks using SM data.The proposedfault diagnosis method for SM via two-layer stacking ensembleoptimization and data augmentation is trained and validatedusing SM fault data collected from 2010 to 2018 in Zhejiang Province,China.Experimental results demonstrate the effectivenessof the proposed method in improving the accuracyof SM fault diagnosis,particularly for minority classes. 展开更多
关键词 Data augmentation fault diagnosis feature extraction smart meter Stacking ensemble optimization
原文传递
Functional Confirmation Using a Medical X-Ray System of a Semiconductor Survey Meter
4
作者 Katsunao Suzuki Toru Negishi +2 位作者 Yoh Kato Yasuhisa Kono Michiharu Sekimoto 《Open Journal of Radiology》 2024年第1期1-13,共13页
In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate ... In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate the time constant of a semiconductor survey meter and confirm the meter’s function. An additional filter was attached to the medical X-ray system to satisfy the standards of N-60 to N-120, more copper plates were added as needed, and the first and second half-value layers were calculated to enable comparisons of the facility’s X-ray system quality with the N-60 to N-120 quality values. Next, we used a medical X-ray system to measure the leakage dose and calculate the time constant of the survey meter. The functionality of the meter was then checked and compared with the energy characteristics of the meter. The experimental results showed that it was possible to use a medical X-ray system to reproduce the N-60 to N-120 radiation quality values and to calculate the time constant from the measured results, assuming actual leakage dosimetry for that radiation quality. We also found that the calibration factor was equivalent to that of the energy characteristics of the survey meter. 展开更多
关键词 Semiconductor Survey meter Functional Confirmation Medical X-Ray System Calibration Factor Time Constant
下载PDF
Detection of Water Meter Digits Based on Improved Faster R-CNN
5
作者 Liyun Sun Yuying Yuan +1 位作者 Shichao Qiao Ruijie Qi 《Journal of Computer and Communications》 2024年第3期1-13,共13页
In order to more accurately detect the accuracy of word-wheel water meter digits, 2000 water meter pictures were produced, and an improved Faster-RCNN algorithm for detecting water meter digits was proposed. The impro... In order to more accurately detect the accuracy of word-wheel water meter digits, 2000 water meter pictures were produced, and an improved Faster-RCNN algorithm for detecting water meter digits was proposed. The improved Faster-RCNN algorithm uses ResNet50 combined with FPN (Feature Pyramid Network) structure instead of the original ResNet50 as the feature extraction network, which can enhance the accuracy of the model for small-sized digit recognition;the use of ROI Align instead of ROI Pooling can eliminate the error caused by the quantization process of the ROI Pooling twice, so that the candidate region is more accurately mapped to the feature map, and the accuracy of the model is further enhanced. The experiment proves that the improved Faster-RCNN algorithm can reach 91.8% recognition accuracy on the test set of homemade dataset, which meets the accuracy requirements of automatic meter reading technology for water meter digital recognition, which is of great significance for solving the problem of automatic meter reading of mechanical water meters and promoting the intelligent development of water meters. 展开更多
关键词 Faster RCNN Identification of Water meter Numbers ResNet50 FPN ROI Align
下载PDF
Iterative learning control approach for ramp metering 被引量:4
6
作者 ZhongshengHOU JianxinXU 《控制理论与应用(英文版)》 EI 2005年第1期27-34,共8页
An iterative learning control scheme is developed to the traffic densitycontrol in a macroscopic level freeway environment. With rigorous analysis, the proposed intelligentcontrol scheme guarantees the asymptotic conv... An iterative learning control scheme is developed to the traffic densitycontrol in a macroscopic level freeway environment. With rigorous analysis, the proposed intelligentcontrol scheme guarantees the asymptotic convergence of the traffic density to the desired one. Thecontrol scheme is applied to a freeway model, and simulation results confirm the efficacy of theproposed approach. 展开更多
关键词 macroscopic traffic flow model traffic density control iterative learningcontrol freeway ramp metering
下载PDF
Discrete Particle Simulation of Gas-Solid Flow in Air-Blowing Seed Metering Device 被引量:6
7
作者 Zhengquan Li Pei Zhang +3 位作者 Yongchang Sun Chenglin Zheng Liang Xu Dianyu E 《Computer Modeling in Engineering & Sciences》 SCIE EI 2021年第6期1119-1132,共14页
In this paper,the gas and seed flow characters in the air-blowing seed metering device are investigated by using the coupled computational fluid dynamics and discrete element method(CFD-DEM)in three dimensions(3D).The... In this paper,the gas and seed flow characters in the air-blowing seed metering device are investigated by using the coupled computational fluid dynamics and discrete element method(CFD-DEM)in three dimensions(3D).The method of establishing boundary model based on the computer-aided design(CAD)drawing,has been used to build the boundary model of seed metering device.The 3D laser scanning technique and multi-element method are adopted to establish the particle model.Through a combined numerical and experimental effort,using 3D CFD-DEM software,which is based on the in-house codes,the mechanisms governing the gas and solid dynamic behaviors in the seed metering device have been studied.The gas velocity field and the effect of different rotational speeds and air pressures on the seeding performance and particle velocity have been studied,similar agreements between numerical and experimental results are gained.This reveals that the 3D CFD-DEM model established is able to predict the performance of the air-blowing seed metering device.It can be used to design and optimize the air-blowing seed metering device and other similar agriculture devices. 展开更多
关键词 Seed metering device CFD-DEM CAD SIMULATION gas-solid flow
下载PDF
Robust Non-fragile PID Controller Design for the Stroke Regulation of Metering Pumps 被引量:3
8
作者 余世明 吴江江 张端 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第1期83-88,共6页
This job focuses on the stroke regulation of a class of high-precision metering pumps.A parametertuning method of robust non-fragile PID(proportional-integral-derivative)controllers is proposed with the assumption t... This job focuses on the stroke regulation of a class of high-precision metering pumps.A parametertuning method of robust non-fragile PID(proportional-integral-derivative)controllers is proposed with the assumption that a PID controller has additive gain perturbations.An H-infinite robust PID controller can be obtained by solving a linear matrix inequality.This approach can guarantee that the closed-loop control systems is asymptotically stable and the H-infinite norm of the transfer function from the disturbance to the output of a controlled system is less than a given constant to attenuate disturbances.The simulation case shows that the control performance of the proposed strategy is significantly better than the traditional PID approach in the situation with perturbations of controller parameters. 展开更多
关键词 metering pump stroke regulation H-infinite robust control PID control NON-FRAGILE
下载PDF
Embedded TLS 1.2 Implementation for Smart Metering & Smart Grid Applications 被引量:1
9
作者 Atta Kofi Nsiah Axel Sikora +1 位作者 Andreas Walz Artem Yushev 《Journal of Electronic Science and Technology》 CAS CSCD 2015年第4期373-378,共6页
Digital networked communications are the key to all Internet-of-things applications, but especially to smart metering systems and the smart grid. In order to ensure a safe operation of systems and the privacy of users... Digital networked communications are the key to all Internet-of-things applications, but especially to smart metering systems and the smart grid. In order to ensure a safe operation of systems and the privacy of users, the transport layer security (TLS) protocol, a mature and well standardized solution for secure communications, may be used. We implemented the TLS protocol in its latest version in a way suitable for embedded and resource-constrained systems. This paper outlines the challenges and opportunities of deploying TLS in smart metering and smart grid applications and presents performance results of our TLS implementation. Our analysis shows that given an appropriate implementation and configuration, deploying TLS in constrained smart metering systems is possible with acceptable overhead. 展开更多
关键词 Embedded software smart grids smart metering transport layer security.
下载PDF
A Prepaid Smart Metering Scheme Based on WiMAX Prepaid Accounting Model 被引量:2
10
作者 Reduan H. Khan Tanzim F. Aditi +1 位作者 Victor Sreeram Herbert H. C. Iu 《Smart Grid and Renewable Energy》 2010年第2期63-69,共7页
Prepaid energy meters have been widely adopted by utilities in different countries across the world as an innovative solution to the problem of affordability and consumption management. However, the present smart card... Prepaid energy meters have been widely adopted by utilities in different countries across the world as an innovative solution to the problem of affordability and consumption management. However, the present smart card based systems have some inherent problems like added cost, low availability and lack of security. In the future Smart Grid paradigm, use of smart meters can completely overhaul these prepaid systems by introducing centralized accounting, monitoring and credit-control functions using state-of-the-art telecommunication technologies like WiMAX. In this paper we pro-pose a prepaid smart metering scheme for Smart Grid application based on centralized authentication and charging using the WiMAX prepaid accounting model. We then discuss its specific application to Demand Response and Roam-ing of Electrical Vehicles. 展开更多
关键词 SMART metering WIMAX SMART GRID DEMAND Response Electric VEHICLES
下载PDF
Effects of the precipitation of stabilizers on the mechanism of grain fracturing in a zirconia metering nozzle 被引量:2
11
作者 Liang Zhao Qun-hu Xue Dong-hai Ding 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2016年第9期1041-1047,共7页
The mechanism of grain fracturing in a zirconia metering nozzle used in the continuous casting process was studied. The phase composition, microstructure, and chemical composition of the residual samples were studied ... The mechanism of grain fracturing in a zirconia metering nozzle used in the continuous casting process was studied. The phase composition, microstructure, and chemical composition of the residual samples were studied using an X-ray fluorescence analyzer, scanning electron microscope, and electron probe. Results revealed that the composition, structure, and mineral phase of the original layer, transition layer, and affected layer of the metering nozzle differed because of stabilizer precipitation and steel slag permeation. The stabilizer MgO formed low-melting phases with steel slag and impure SiO2 on the boundaries(pores) of zirconia grains; consequently, grain fracturing occurred and accelerated damage to the metering nozzle was observed. 展开更多
关键词 continuous casting metering nozzle partially stabilized zirconia grains fracture mechanisms electron probe microanalysis
下载PDF
Design of Metering Device Key Parts of Pneumatic Grass Seeder 被引量:1
12
作者 Zhai Gaixia Wang Zhenhua He Gang Liu Guilin Yang Li 《Journal of Earth Science and Engineering》 2015年第5期289-295,共7页
Based on the mechanical and physical properties study of forage grass seeds, multi-line with one-device type metering device was designed. It was composed of adjustable screw, stirrer, metering device housing and cent... Based on the mechanical and physical properties study of forage grass seeds, multi-line with one-device type metering device was designed. It was composed of adjustable screw, stirrer, metering device housing and central metering sheave and so on. The sowing rate can be set by turning the screw to change the working length of the central metering sheave relative to the metering device housing. The stirrer inside of the sheave housing is used to prevent seeds overhead. And metering of different sizes of seed is adjusted by changing the position of internal components of the slot wheel mechanism. Innovative design on the structure of the central metering sheave was finished. According to the structure parameters and physical characteristic parameters, different seed sowing rate of per hectares was calculated. And then the working length scale of the central metering groove wheel was made. And there is a one-to-one correspondence between scale values and sowing quantity per hectare of different kinds of seed. 展开更多
关键词 SEEDER metering device central metering sheave sowing rate.
下载PDF
Residential PV capacity estimation and power disaggregation using net metering measurements 被引量:1
13
作者 Bo Liu Jianmin Tian +3 位作者 Wenpeng Luan Yi Gao Xiaohui Wang Shuai Luo 《Global Energy Interconnection》 EI CAS CSCD 2022年第6期590-603,共14页
As the intermittency and uncertainty of photovoltaic(PV)power generation poses considerable challenges to the power system operation,accurate PV generation estimates are critical for the distribution operation,mainten... As the intermittency and uncertainty of photovoltaic(PV)power generation poses considerable challenges to the power system operation,accurate PV generation estimates are critical for the distribution operation,maintenance,and demand response program implementation because of the increasing usage of distributed PVs.Currently,most residential PVs are installed behind the meter,with only the net load available to the utilities.Therefore,a method for disaggregating the residential PV generation from the net load data is needed to enhance the grid-edge observability.In this study,an unsupervised PV capacity estimation method based on net metering data is proposed,for estimating the PV capacity in the customer’s premise based on the distribution characteristics of nocturnal and diurnal net load extremes.Then,the PV generation disaggregation method is presented.Based on the analysis of the correlation between the nocturnal and diurnal actual loads and the correlation between the PV capacity and their actual PV generation,the PV generation of customers is estimated by applying linear fitting of multiple typical solar exemplars and then disaggregating them into hourly-resolution power profiles.Finally,the anomalies of disaggregated PV power are calibrated and corrected using the estimated capacity.Experiment results on a real-world hourly dataset involving 260 customers show that the proposed PV capacity estimation method achieves good accuracy because of the advantages of robustness and low complexity.Compared with the state-of-the-art PV disaggregation algorithm,the proposed method exhibits a reduction of over 15%for the mean absolute percentage error and over 20%for the root mean square error. 展开更多
关键词 Behind-the-meter Residential photovoltaic Capacity estimation Power disaggregation Net metering
下载PDF
Investigation into the Independent Metering Control Performance of a Twin Spools Valve with Switching Technology-controlled Pilot Stage 被引量:5
14
作者 Qi Zhong Huiming Bao +3 位作者 Yanbiao Li Haocen Hong Bin Zhang Huayong Yang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2021年第5期226-242,共17页
In hydraulic area,independent metering control(IMC)technology is an effective approach to improve system efficiency and control flexibility.In addition,digital hydraulic technology(DHT)has been verified as a reasonabl... In hydraulic area,independent metering control(IMC)technology is an effective approach to improve system efficiency and control flexibility.In addition,digital hydraulic technology(DHT)has been verified as a reasonable method to optimize system dynamic performance.Integrating these two technologies into one component can combine their advantages together.However,few works focused on it.In this paper,a twin spools valve with switching technologycontrolled pilot stage(TSVSP)is presented,which applied DHT into its pilot stage while appending IMC into its main stage.Based on this prototype valve,a series of numerical and experiment analysis of its IMC performance with both simulated load and excavator boom cylinder are carried out.Results showed fast and robust performance of pressure and flow compound control with acceptable fluctuation phenomenon caused by switching technology.Rising time of flow response in excavator cylinder can be controlled within 200 ms,meanwhile,the recovery time of rod chamber pressure under suddenly changed condition is optimized within 250 ms.IMC system based on TSVSP can improve both dynamic performance and robust characteristics of the target actuator so it is practical in valve-cylinder system and can be applied in mobile machineries. 展开更多
关键词 High speed on/off valve(HSV) Digital hydraulic technology(DHT) Switching pilot control Twin spools valve Independent metering control(IMC)
下载PDF
Ratio K: a New Way of Metering and Evaluating the Risk and Return of Stock Investment 被引量:1
15
作者 朱淑珍 朱静怡 《Journal of Donghua University(English Edition)》 EI CAS 2003年第2期129-136,共8页
Although widely used, both the Markowitz model and VAR (Value at Risk) model have some limitations in evaluating the risk and return of stock investment. By the analysis of the conceptions of risk and return, together... Although widely used, both the Markowitz model and VAR (Value at Risk) model have some limitations in evaluating the risk and return of stock investment. By the analysis of the conceptions of risk and return, together with the three hypotheses of technological analysis, a novelty model of metering and evaluating the risk and return of stock investment is established. The major indicator of this model , risk-return ratio K, combines the characteristic indicators of risk and return. Regardless of the form of the risk-return probability density functions, this indicator K can always reflect the risk-return performances of the invested stocks clearly and accurately. How to use the model to make optimum investment and how to make portfolio combined with clustering analysis is also explained. 展开更多
关键词 Stock investment risk and return risk-return ratio K metering and evaluating
下载PDF
Exploiting the Cellular Infrastructure for Data Transmission in Smart Metering Systems 被引量:1
16
作者 Athanasios Giannakopoulos Panayotis G. Cottis 《Journal of Computer and Communications》 2016年第7期31-41,共11页
To implement the access and backhaul networks for Smart Metering (SM) systems various technologies are combined with the existing communications infrastructure. This paper deals with data transmission in SM systems, f... To implement the access and backhaul networks for Smart Metering (SM) systems various technologies are combined with the existing communications infrastructure. This paper deals with data transmission in SM systems, focusing on how the existing cellular networks infrastructure is employed to implement SM access communication networks. The analysis aims at analyzing the role of the cellular communications infrastructure taking into account the spatial distribution and installation points of the smart meters, the urban and topological characteristics of the SM deployment areas and the common practice so far followed by the utilities. It is demonstrated that cellular communications, either exclusively or combined with power line communications, enable immediate and scalable deployment of SM access communication networks at low installation cost, thus constituting the basic option for the implementation of smart metering. 展开更多
关键词 Smart metering (SM) SM Access Communication Networks Cellular Communication Networks Power Line Communications
下载PDF
Effects of temperature-gradient-induced damage of zirconia metering nozzles
17
作者 Liang Zhao Qun-hu Xue 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期999-1003,共5页
The effects of temperature-gradient-induced damage of zirconia metering nozzles were investigated through analysis of the phase composition and microstructure of nozzle samples. The analysis was carried out using X-ra... The effects of temperature-gradient-induced damage of zirconia metering nozzles were investigated through analysis of the phase composition and microstructure of nozzle samples. The analysis was carried out using X-ray diffraction and scanning electron microscopy after the samples were subjected to a heat treatment based on the temperatures of the affected, transition, and original layers of zirconia metering nozzles during the continuous casting of steel. The results showed that, after heat treatment at 1540, 1410, or 1300A degrees C for a dwell time of 5 h, the monoclinic zirconia phase was gradually stabilized with increasing heat-treatment temperature. Moreover, a transformation to the cubic zirconia phase occurred, accompanied by grain growth, which illustrates that the temperature gradient in zirconia metering nozzles affects the mineral composition and microstructure of the nozzles and accelerates damage, thereby deteriorating the quality and service life of the nozzles. 展开更多
关键词 temperature gradient zirconia metering nozzles mineral composition MICROSTRUCTURE damage mechanism
下载PDF
Vacuum and Air Flow for 2QXP-1 Vacuum Precision Seed Metering
18
作者 Su Wei Wang Fu-lin +1 位作者 Chen Hai-tao Lai Qing-hui 《Journal of Northeast Agricultural University(English Edition)》 CAS 2013年第2期61-64,共4页
Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification perce... Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification percent and miss percent on air chamber vacuum 3, 4, 5 and 6 kPa were studied at different operating speeds. The results showed that operating performance of the seed metering was excellent when air chamber vacuum was 5 and 6 kPa, which air flow was 7.4-8.0 m3·s-1 and 8.0-8.8 m3·s-1 , respectively. 展开更多
关键词 seed planter precision seed metering vacuum degree air flow
下载PDF
Analysis and Research on Low-Cost and Non-Intrusive Power Metering Chip
19
作者 Li-Ping Gao Xiu-Li Yu +1 位作者 Liang Huang Tao-Rong Gong 《Energy and Power Engineering》 2017年第4期573-580,共8页
Metering technology is one of the core technologies of the smart power grid. The overall metering solution and related products have a wide market space in the whole process of power production, which bring new opport... Metering technology is one of the core technologies of the smart power grid. The overall metering solution and related products have a wide market space in the whole process of power production, which bring new opportunities for power distribution development from automation to intelligentialize, and provide technical supports for the power metering system platform. Because of the importance of metering products and their market demand, this paper focuses on the design of a simple power metering chip with low-cost, low-precision and non-invasive, so as to lay the foundation for the development and practical technology accumulation of power metering products. The design achieves low cost by reducing the acquisition accuracy, simplifying the collection and sampling methods. This paper studies the chip accuracy, sampling methods, collection methods, and the inference of the chip characteristics requirements. 展开更多
关键词 POWER metering CHIP LOW-COST Low-Precision Sampling Methods
下载PDF
Simulation Analysis of Characteristics for Independent Metering Control System Based on Downstream Compensation
20
作者 Guotai Zhang Jie Xu +1 位作者 Jing Yang Kailei Liu 《World Journal of Engineering and Technology》 2019年第3期536-547,共12页
Aiming at the shortcomings of the separate meter in and separate meter out?hydraulic system, a new type of independent metering control system is proposed by referring to the principle of load-sensing system. The valv... Aiming at the shortcomings of the separate meter in and separate meter out?hydraulic system, a new type of independent metering control system is proposed by referring to the principle of load-sensing system. The valve group unit in the system is designed, and the AMESim/Matlab cosimulation model of the component and system is established. The actuator speed control, energy consumption and anti-flow saturation characteristics of the system are discussed. The simulation result shows that the system proposed in this article can achieve?better performances. 展开更多
关键词 INDEPENDENT metering Control Pressure COMPENSATION COSIMULATION
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部