期刊文献+
共找到1,226篇文章
< 1 2 62 >
每页显示 20 50 100
Determination of pKa values of alendronate sodium in aqueous solution by piecewise linear regression based on acid-base potentiometric titration 被引量:2
1
作者 Jing Ke Hanfei Dou +3 位作者 Ximin Zhang Dushimabararezi Serge Uhagaze Xiali Ding Yuming Dong 《Journal of Pharmaceutical Analysis》 SCIE CAS 2016年第6期404-409,共6页
As a mono-sodium salt form of alendronic acid,alendronate sodium presents multi-level ionization for the dissociation of its four hydroxyl groups.The dissociation constants of alendronate sodium were determined in thi... As a mono-sodium salt form of alendronic acid,alendronate sodium presents multi-level ionization for the dissociation of its four hydroxyl groups.The dissociation constants of alendronate sodium were determined in this work by studying the piecewise linear relationship between volume of titrant and p H value based on acidbase potentiometric titration reaction.The distribution curves of alendronate sodium were drawn according to the determined p Ka values.There were 4 dissociation constants(pKa_1=2.43,pKa_2=7.55,pKa_3=10.80,pKa_4=11.99,respectively) of alendronate sodium,and 12 existing forms,of which 4 could be ignored,existing in different p H environments. 展开更多
关键词 Dissociation CONSTANTS ALENDRONATE SODIUM Distribution curve Piecewise linear regression ACID-BASE potentiometric titration
下载PDF
POTENTIOMETRIC TITRATION OF CALCIUM IN SEAWATER 被引量:1
2
作者 谢式南 纪红 +1 位作者 吴爱琴 陈国华 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 1997年第1期32-35,共4页
By using calcium ion selective elatrode (Ca ISE) as indicating electrode, saturated calomel electrode (SCE) as reference electrode and EGTA as titrant, calcium in seawater was determined by potentiometric titration in... By using calcium ion selective elatrode (Ca ISE) as indicating electrode, saturated calomel electrode (SCE) as reference electrode and EGTA as titrant, calcium in seawater was determined by potentiometric titration in borate buffer solution. This method can reduce observation errors in the determination of the endpoint, and thus provide better analytical precision(<0.08%) than present complexometric titration. 展开更多
关键词 CALCIUM ION SELECTIVE elatrode CALCIUM seawater potentiometric titration
下载PDF
Determination of Formation Constants of Co ̄(2+), Ni ̄(2+),Cu ̄(2+) and Zn ̄(2+) Complexes with Humic and Fulvic Acidsby Potentiometric Titration Method 被引量:1
3
作者 DUJIN-ZHOU LUCHANG-QING 《Pedosphere》 SCIE CAS CSCD 1994年第4期289-296,共8页
The formation constants of Co ̄(2+), Ni ̄(2+), Cu ̄(2+) and Zn ̄(2+) complexes with humic acid (HA) and fulvicacid (FA) in red soil were determined by the potentiometric titration method. The constants as a functionof... The formation constants of Co ̄(2+), Ni ̄(2+), Cu ̄(2+) and Zn ̄(2+) complexes with humic acid (HA) and fulvicacid (FA) in red soil were determined by the potentiometric titration method. The constants as a functionof composition of the complexation solutions were obtained by two graphical approaches respectively Theformation constants decreased with increasing concentration of metal in the solution. The results provideunambiguous evidence for the heterogeneity of the function groups of humic substances. The formationconstants of FA were much smaller than those of HA, and the formation constants of Cu ̄(2+) were muchgreater than those of Co ̄(2+) , Ni ̄(2+) and Zn ̄(2+) . The potentiometric titration method for determining formationconstants are also discussed in the article. 展开更多
关键词 formation constants of complexes humic and fulvic acids potentiometric titration red soil
下载PDF
Studies on Determination of Ge in Au Alloys by Potassium Iodate Potentiometric Titration Method
4
作者 ZHU Liya ZHOU Yu +8 位作者 TAN Yanshan LIU Wen LI Yong HAN Shouli TAN Wenjin HE Xiaotan WU Xilong XIE Hongchao CHEN Liangwei 《贵金属》 CAS CSCD 北大核心 2012年第A01期298-304,共7页
The paper presents a new method of determining Ge in gold alloys by potassium iodate potentiometric titration rather than by traditional distillation separation. The influences of conditions such as the reduction acid... The paper presents a new method of determining Ge in gold alloys by potassium iodate potentiometric titration rather than by traditional distillation separation. The influences of conditions such as the reduction acidity, dosage of sodium hypophosphite and reduction time on the determination of Ge were studied. Comparison was made between the influences of end-point indication for potential method and starch method on accruracy and precision of the analysed results, stability and sensitivity of end-point, selectivity of method and so on. The possibility of reaction in an electrochemical way was discussed. Ge in the alloys such as AuGe 12 , AuGeNi 12 2 , AuAgGe 18.8 12.5 and AuAgGeNi 43.8 6 0.2 was measured, respectively, with the relative standard deviation of 0.10%~0.31% and the recoveries of added standard Ge in sample of 99.40%~100.40% when the reduction acidity was 0.40~0.80 mol/L HCl and 3.3 mol/L H 3 PO 4, 15 g sodium hypophosphite and reduction time 40 min. The new method presented is high accuracy and precision in results, good stability and sensibility in end point, easy operation and strong selectivity of determination. When it is applied to analyse actual samples, satisfactory results are achieved. 展开更多
关键词 analytical chemistry GERMANIUM gold alloy potentiometric titration
下载PDF
Determination of Sulfides in FCC Gasoline by Using the Potentiometric Titration of Lead Tetraacetate
5
作者 罗立文 夏道宏 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2004年第3期448-450,共3页
Compared with conventional method of violet spectrum, determination of the content of sulfides in fluid catalytic cracking (FCC) gasoline by using the potentiometric titration of lead tetraacetate has some advantages ... Compared with conventional method of violet spectrum, determination of the content of sulfides in fluid catalytic cracking (FCC) gasoline by using the potentiometric titration of lead tetraacetate has some advantages such as clear potentiometric abrupt change at the stoichiometric point, stable potentiometric value, exact and credible results, and simple operation. The content of sulfides in FCC gasoline of Shenghua refinery is 0.136% by this method. The standard deviation about this method is less than 0.01% and the relative standard deviation is less than 2.42%. 展开更多
关键词 SULFIDE GASOLINE lead tetraacetate potentiometric titration
下载PDF
Counterion Binding in Aqueous Solutions of Poly(vinylpyridines) as Assessed by Potentiometric Titration
6
作者 Jim D. Roach Mandy M. Bondaruk +1 位作者 Abdulaziz Al-Abdulghani Zaid Shahrori 《Advances in Materials Physics and Chemistry》 2016年第9期249-261,共13页
The extent to which counterions bind to polyelectrolytes influences a variety of polymer-based applications, including polyelectrolyte enhanced ultrafiltration and forward osmosis using polyelectrolytes as draw agents... The extent to which counterions bind to polyelectrolytes influences a variety of polymer-based applications, including polyelectrolyte enhanced ultrafiltration and forward osmosis using polyelectrolytes as draw agents. Potentiometric titrations of poly (2-vinylpyridine) (P2VP), poly (3-vinylpyridine) (P3VP), and poly (4-vinylpydine) (P4VP) were performed using HBr, HCl, HNO<sub>3</sub>, and HClO<sub>4</sub> in both the presence and absence of added NaCl. Because of the systematic differences among the three polyelectrolytes, titration results provide insight into the role of polymer structure in the relative extents to which various counterions bind. Titration data reveal that ionization properties vary as functions of polymer investigated, titrant used, degree of protonation, and added salt concentration. Acid dissociation constants of the pyridinium moieties were found to generally increase with increasing degree of protonation, though appreciable differences were exhibited among the three polymers investigated. For all three polymers, Cl<sup>-</sup> demonstrated the lowest affinity for the charged pyridinium residues, while the affinities associated with Br<sup>-</sup> and NO<sup>-</sup>3</sub> were nearly identical to each other. The relative extent of binding for CIO<sup>-</sup>4</sub> varied across the polymers investigated, and was greatest for P4VP. 展开更多
关键词 Poly(vinylpyridine) Counterion Binding potentiometric titration PERCHLORATE
下载PDF
Acid Dissociation Constants of Functional Groups in Humic Substances:I.Affinity Spectrum Model Analysis of Potentiometric Data of Fulvic and Humic Acids Solutions from Weathered Coal and Dark Loessial Soil 被引量:1
7
作者 DUJIN-ZHOU LUCHANG-QING 《Pedosphere》 SCIE CAS CSCD 1994年第3期201-208,共8页
Potentiometric experiments were carried out on the proton binding equilibria of FA extracted from a weathered coal and HA and Fa extracted from a dark loessial soil.The affinity spectrum model was employed to treat th... Potentiometric experiments were carried out on the proton binding equilibria of FA extracted from a weathered coal and HA and Fa extracted from a dark loessial soil.The affinity spectrum model was employed to treat the experimental data.The affinity spectrum model technique could“magnify” the heterogeneity of the proton binding equilibria.so it was useful for comparing and studying the characteristics of humic substances with similar properties.According to the affinity spectra,we also found that the direction of the titration could affect the properties of the equilibria of FA from the weathered coal,and the acidic functional groups contained in FA from the weathered coal were larger in quantity than those contained in HA and FA from the dark loessial soil. 展开更多
关键词 affinity spectrum HETEROGENEITY humic substances potentiometric titration
下载PDF
All-Solid-State Screen-Printed Sensors for Potentiometric Calcium(II) Determinations in Environmental Samples
8
作者 Johannes Schwarz Kathrin Trommer +1 位作者 Frank Gerlach Michael Mertig 《American Journal of Analytical Chemistry》 2018年第3期113-123,共11页
This paper describes preparation, characterization and electrochemical performance of novel planar miniaturized all-solid-state (ASS) screen-printed potentiometric sensors for the detection of Ca2+ ions in environment... This paper describes preparation, characterization and electrochemical performance of novel planar miniaturized all-solid-state (ASS) screen-printed potentiometric sensors for the detection of Ca2+ ions in environmental samples. Screen-printed graphite-based ion-selective electrodes (ISEs) and screen-printed reference electrodes based on silver-containing pastes have been applied in a space saving manner on common ceramic substrates with small dimensions. Applications to environmental samples are shown by direct potentiometry and potentiometric titrations in real water samples. Conducting polymers (CPs) have been used as solid-contact materials and as intermediate layer between the polyvinyl chloride (PVC)-containing ion-selective membrane and the graphite-containing substrate. Different diamides have been incorporated into the PVC membrane. In the range from 10-4 mol/L to 10-1 mol/L, the ISEs show linear slopes of 27 mV/decade, which is close to the Nernstian response. Moreover, the ISEs have response times of 6 months. The novel potentiometric ASS sensors enable simple and exact Ca2+ determinations in real samples. 展开更多
关键词 ALL-SOLID-STATE Sensor Ca2+-Selective Electrode potentiometric titration Environmental SAMPLES
下载PDF
用电位滴定法测定含锌硫化活性剂中锌含量
9
作者 杨娜 丁新艳 +4 位作者 昌慧娟 穆洪帅 倪子贞 刘国钧 王进 《合成橡胶工业》 CAS 2024年第4期290-295,共6页
将含锌硫化活性剂直接溶解于盐酸溶液中,以乙二胺四乙酸二钠为滴定剂、铜离子选择电极为指示电极、银/氯化银为参比电极,采用电位滴定法测定含锌硫化活性剂中的锌含量。研究表明,硫酸铜的加入可增大滴定曲线的突跃范围,且铜离子选择电极... 将含锌硫化活性剂直接溶解于盐酸溶液中,以乙二胺四乙酸二钠为滴定剂、铜离子选择电极为指示电极、银/氯化银为参比电极,采用电位滴定法测定含锌硫化活性剂中的锌含量。研究表明,硫酸铜的加入可增大滴定曲线的突跃范围,且铜离子选择电极在pH值为10的缓冲体系中灵敏度较高。采用电位滴定法测定2种含锌硫化活性剂中的锌离子含量及其回收率,并与原子发射光谱法进行比较,结果表明该两种硫化活性剂中锌离子含量回收率分别为100.13%和99.32%,且两种测试方法所得结果无明显差异,采用电位滴定法测定标准溶液中的锌离子含量并进行统计检验,结果显示测试值与标准值无明显差异,说明采用电位滴定法测定含锌硫化活性剂中锌含量可行有效。同时测定了混炼橡胶中硫化活性剂的锌离子含量,结果与理论计算值相近,故该方法同样适用于混炼橡胶中锌离子含量的测定。 展开更多
关键词 含锌硫化活性剂 锌含量 电位滴定法 铜离子选择电极
下载PDF
PMIA树脂溶液中盐酸含量的测定
10
作者 杨娜 宋志成 +3 位作者 丁新艳 王进 刘国钧 曹凯凯 《合成纤维工业》 CAS 2024年第1期90-95,共6页
分别以乙酸钠-甲醇溶液、氢氧化钾-甲醇溶液为滴定剂,采用电位滴定法测定不同中和程度的聚间苯二甲酰间苯二胺(PMIA)树脂溶液中盐酸含量,并对2种测试方法的准确度和精密度进行比较。结果表明:采用2种测试方法测定中和程度分别为0、60%、... 分别以乙酸钠-甲醇溶液、氢氧化钾-甲醇溶液为滴定剂,采用电位滴定法测定不同中和程度的聚间苯二甲酰间苯二胺(PMIA)树脂溶液中盐酸含量,并对2种测试方法的准确度和精密度进行比较。结果表明:采用2种测试方法测定中和程度分别为0、60%、95%、100%的PMIA树脂溶液中盐酸含量,2种测试方法的测定结果相近;采用F检验和t检验两种统计法验证了显著性水平为0.05、置信度为95%时2种测试方法的准确度和精密度均无显著差异,以氢氧化钾-甲醇溶液为滴定剂的测试方法的精密度更高;采用标准盐酸加入法,并以氢氧化钾-甲醇溶液为滴定剂测定不同中和程度的PMIA树脂溶液中盐酸回收率,平均回收率为96.5%~98.5%,验证了该方法的准确性;对于正常滴定过程中等当点不易识别的PMIA树脂溶液,可通过预加已知量的盐酸后再采用氢氧化钾-甲醇溶液滴定,从而确定溶液的酸碱性。 展开更多
关键词 聚间苯二甲酰间苯二胺溶液 中和程度 盐酸含量 电位滴定法
下载PDF
电位滴定法与高效液相色谱法测定兽用复方制剂中巴比妥含量
11
作者 高志存 高芸 +3 位作者 段平波 万彬彬 余舒宁 崔惠娟 《中兽医医药杂志》 CAS 2024年第2期71-75,共5页
分析比较电位滴定法与高效液相色谱法在巴比妥含量测定上的差异,以期为实际检测工作提供参考。采用916 Ti-Touch自动电位滴定仪,用硝酸银滴定液进行电位滴定。高效液相色谱法采用Xbridge C18色谱柱(150.0 mm×4.6 mm,5µm);流... 分析比较电位滴定法与高效液相色谱法在巴比妥含量测定上的差异,以期为实际检测工作提供参考。采用916 Ti-Touch自动电位滴定仪,用硝酸银滴定液进行电位滴定。高效液相色谱法采用Xbridge C18色谱柱(150.0 mm×4.6 mm,5µm);流动相为乙腈-0.05 mol/L磷酸二氢钾溶液(体积比25∶75,用三乙胺调节pH值至8.2);检测波长240 nm;柱温30℃,流速1.0 mL/min,进样体积10µL。结果显示,电位滴定法加标回收率为100.2%~101.2%,RSD为0.1%;高效液相色谱法加标回收率为99.0%~101.6%,RSD为0.1%~0.2%。分别采用电位滴定法和高效液相色谱法测定12批不同厂家兽用复方氨基比林注射液和安痛定注射液中巴比妥含量,两种方法测定结果差异不显著(P>0.05)。高效液相色谱法耗时长,成本高,更适用于复方制剂中多种成分的同时测定;电位滴定法操作简便快速,准确度高,精密度好,更适用于巴比妥单一成分含量的测定。 展开更多
关键词 电位滴定法 高效液相色谱法 巴比妥 含量测定
下载PDF
以实际检测为导向的仪器分析实验教学实践
12
作者 王玉芹 陈俏钰 陈怡馨 《实验室研究与探索》 CAS 北大核心 2024年第6期138-141,共4页
为了实现学在课堂用于课外的仪器分析训练目标,以实际检测为导向,设计了一个仪器分析实验项目——市售食盐中不同形态碘的含量测定。通过精密度和加标回收率实验,验证了自动电位滴定法的准确性和替代传统国标手动滴定法的可行性。教学... 为了实现学在课堂用于课外的仪器分析训练目标,以实际检测为导向,设计了一个仪器分析实验项目——市售食盐中不同形态碘的含量测定。通过精密度和加标回收率实验,验证了自动电位滴定法的准确性和替代传统国标手动滴定法的可行性。教学实践结果表明,滴定实验现象明显,项目内容充实,检测报告可自动生成以供量值溯源,极大地激发了学生的学习兴趣。 展开更多
关键词 实际检测 仪器分析实验 自动电位滴定法 碘含量
下载PDF
铀酰离子与柠檬酸的配位化学研究
13
作者 李智 张燕 +4 位作者 纳森卜彦日 丁琪秀 杨素亮 王琛 田国新 《原子能科学技术》 EI CAS CSCD 北大核心 2024年第9期1930-1942,共13页
柠檬酸(2-羟基-1,2,3-丙三羧酸,H_(3)Cit)常用于铀污染的去污和铀污染土壤的修复。然而以往对水溶液中铀酰离子与柠檬酸配位化学的研究大多是在低pH区域和柠檬酸与铀酰离子比例较低的条件下进行的,在更宽的pH范围内进行的实验和去污实践... 柠檬酸(2-羟基-1,2,3-丙三羧酸,H_(3)Cit)常用于铀污染的去污和铀污染土壤的修复。然而以往对水溶液中铀酰离子与柠檬酸配位化学的研究大多是在低pH区域和柠檬酸与铀酰离子比例较低的条件下进行的,在更宽的pH范围内进行的实验和去污实践中,所得到的配位模型和热力学常数不能很好地解释大多数观察结果。为探究UO_(2)^(2+)与H_(3)Cit在宽pH范围和高铀酰柠檬酸比例下的配位反应,本文通过采用电位滴定和吸收光谱滴定方法测定不同条件下生成的一系列UO_(2)^(2+)与H_(3)Cit配合物的稳定常数,并通过解析滴定过程中采集的光谱获得各物种的标准摩尔吸收谱。结果表明,在pH=2~12区间,随着pH的升高,UO_(2)^(2+)与H_(3)Cit可逐渐形成11种不同配比和组成的(UO_(2))_(n)H_(r)Cit_(m)^(2n+r-3m)配合物,分别为n∶r∶m=1∶1∶1、1∶0∶1、2∶0∶2、2∶−1∶2、2∶−2∶2、1∶0∶2、1∶0∶3、3∶−5∶2、3∶−5∶3、1∶−2∶2、1∶−3∶3,其中1∶0∶3、1∶−2∶2和1∶−3∶3三个配合物尚未见文献报道。培养并获得了3∶−5∶3物种晶体,结合其拉曼光谱,通过UO_(2)^(2+)-H_(3)Cit拉曼光谱滴定归属了各物种的拉曼谱带。通过热力学和光谱信息,明确了H_(3)Cit的羟基去质子化并参与配位的机理。H_(3)Cit羟基在参与和UO_(2)^(2+)的配位时,UO_(2)^(2+)对羟基O—H键的强极化作用,使得H_(3)Cit羟基能在pH=1.5时发生去质子化,并通过羟基氧和羧基氧与UO_(2)^(2+)桥接形成多核配合物;在pH>9和更碱性的溶液中,Cit^(3−)的羟基将更易发生去质子化形成H_(−1)Cit^(3−),这有利于形成1∶−2∶2和1∶−3∶3的单核配合物物种。 展开更多
关键词 铀酰离子 柠檬酸 稳定常数 pH电位滴定 吸收光谱 拉曼光谱
下载PDF
电位滴定法测定能力验证样品含量的不确定度评定
14
作者 杨梅 伍良涌 +1 位作者 李玮玲 邱娟 《中国药业》 CAS 2024年第17期104-107,共4页
目的评定电位滴定法测定能力验证样品含量的不确定度,探讨影响测定的不确定度分量。方法采用电位滴定法测定门冬酰胺一水合物及门冬氨酸含量。建立测量模型,分析不确定度来源,计算各分量的相对标准不确定度及2种样品的合成不确定度。结... 目的评定电位滴定法测定能力验证样品含量的不确定度,探讨影响测定的不确定度分量。方法采用电位滴定法测定门冬酰胺一水合物及门冬氨酸含量。建立测量模型,分析不确定度来源,计算各分量的相对标准不确定度及2种样品的合成不确定度。结果门冬酰胺一水合物含量为87.53%,合成标准不确定度为0.24%;门冬氨酸含量为99.68%,合成标准不确定度为0.22%。结论建立了电位滴定法测定能力验证样品含量的不确定度评定方法,且验证结果满意,可为能力验证样品含量测定结果的可信度提供支持。 展开更多
关键词 电位滴定法 不确定度 能力验证 门冬酰胺一水合物 门冬氨酸 含量测定
下载PDF
自动电位滴定仪标定硫氰酸钠标准溶液 被引量:1
15
作者 卢会珍 杜建侠 李红 《云南化工》 CAS 2024年第3期94-96,共3页
采用916Ti-Touch型全自动电位滴定仪进行硫氰酸钠标准溶液浓度的标定。方法的准确性及精密度都比手动滴定的有很大提高,同时,标定时间大大缩短、操作规程容易掌握、仪器日常维护更加方便,是值得推荐的方法。
关键词 自动电位滴定仪 硫氰酸钠 标定
下载PDF
含油食品酸价检测不确定度评定 被引量:2
16
作者 张学英 《现代农业科技》 2024年第4期130-135,共6页
酸价是反映食品中油脂酸败程度的重要指标,也是食用油或含油食品中必检项目之一。酸价检测不确定度评定可以更科学地评价酸价检测的准确性、科学性和公平性。本文采用冷溶剂指示剂滴定法与冷溶剂自动电位滴定法检测酸价,建立数学模型,... 酸价是反映食品中油脂酸败程度的重要指标,也是食用油或含油食品中必检项目之一。酸价检测不确定度评定可以更科学地评价酸价检测的准确性、科学性和公平性。本文采用冷溶剂指示剂滴定法与冷溶剂自动电位滴定法检测酸价,建立数学模型,分析不确定度来源,评定各不确定度分量、合成不确定度及扩展不确定度。结果表明,自动电位滴定法检测某含油食品酸价结果为6.4 mg/g,扩展不确定度为0.2 mg/g,K=2,显著性不确定度分量为NaOH标准滴定液浓度;指示剂滴定法酸价为6.3 mg/g,扩展不确定度为0.3 mg/g,K=2,显著性不确定度为NaOH标准滴定液浓度不确定度最大、A类不确定度次之、滴定体积不确定度再次之,且三者显著性相近,扩展不确定度大于电位滴定法。通过不确定度评定和显著性分析,可以有针对性地找到降低或控制检测误差的方法,提高检测结果准确性。 展开更多
关键词 含油食品 酸价 不确定度评定 冷溶剂指示剂滴定法 冷溶剂自动电位滴定法
下载PDF
提高工业循环水氯离子检测准确度
17
作者 韩孟雪 卢秀艳 杜士毅 《冶金标准化与质量》 2024年第2期20-23,12,共5页
参考电位自动滴定GB/T 34322-2017《锅炉用水和冷却水水质自动连续测定电位滴定法》方法检测工业循环水中氯离子的含量,通过对预加体积、加液速度、信号漂移三个实验的研究确定了最佳参数,并通过准确度和精密度的实验验证该方法稳定可控... 参考电位自动滴定GB/T 34322-2017《锅炉用水和冷却水水质自动连续测定电位滴定法》方法检测工业循环水中氯离子的含量,通过对预加体积、加液速度、信号漂移三个实验的研究确定了最佳参数,并通过准确度和精密度的实验验证该方法稳定可控,同时与莫尔法进行实验比对,2T实验证实该方法可行,工业循环水中氯离子检测的准确度得到了显著提高。 展开更多
关键词 氯离子 电位自动滴定 准确度
下载PDF
自动电位滴定法检测水中总碱度的应用
18
作者 李沛镡 张雨晨 《净水技术》 CAS 2024年第8期76-82,共7页
研究进行手工滴定法和自动电位滴定法检测水中总碱度的方法对比分析,对空白样品、质控样品和不同类型实际水样的总碱度进行检测,所有检测结果均符合试验要求,检测结果可靠。检测空白样品计算出手工滴定法检出限为2.4 mg/L,测定下限为9.5... 研究进行手工滴定法和自动电位滴定法检测水中总碱度的方法对比分析,对空白样品、质控样品和不同类型实际水样的总碱度进行检测,所有检测结果均符合试验要求,检测结果可靠。检测空白样品计算出手工滴定法检出限为2.4 mg/L,测定下限为9.5 mg/L。自动电位滴定法检出限为0.5 mg/L,测定下限为2.1 mg/L,明显低于手工滴定法。检测不同浓度质控样品,自动电位滴定法相对标准偏差≤0.46%,相对误差≤0.22%,手工滴定法相对标准偏差≤1.46%,相对误差≤2.79%;对实际样品进行平行双样分析,自动电位滴定法相对偏差为0.05%~0.43%,手工滴定法相对偏差为0~2.99%,皆可表明自动电位滴定法有更好的精密度和准确度,检测结果更稳定。对33组实际水样检测结果进行配对t检验,结果为P=0.146(>0.05),表明两种方法无显著差异。手工滴定法不同人员间检测结果相对偏差为0.30%~2.03%,人员偏差明显。对不同浑浊度水样进行加标回收试验,手工滴定法加标回收率为90.0%~108.0%,自动电位滴定法加标回收率为95.8%~104.2%。55 NTU以下水样摇匀和静置后检测结果间相对偏差,手工滴定法<3.7%,自动电位滴定法<1.5%,表明是否摇匀对检测结果无明显影响。相比于手工滴定法易被检测人员熟练程度、专业技术水平、对颜色敏感程度等因素影响,自动电位滴定法更能兼顾准确性和工作效率,实现智能化检测。生活饮用水领域需要尽快弥补总碱度国家标准方法空缺。 展开更多
关键词 总碱度 自动电位滴定法 手工滴定法 高浑浊度水样 智能化检测
下载PDF
饲料酸价测定方法中两种溶剂的对比分析
19
作者 王博媛 杜言 +1 位作者 刘小敏 秦少君 《粮食与饲料工业》 CAS 2024年第2期72-75,共4页
采用自动电位滴定仪,分别用乙醚-乙醇混合溶液和乙醚-异丙醇混合溶液两种混合溶剂对大豆毛油、菜籽毛油、大豆磷脂油、三级棉籽油、菜粕、猪配合饲料、鸡配合饲料、水产饲料等20种饲料原料及配合饲料的酸价进行了测定,通过对测定结果进... 采用自动电位滴定仪,分别用乙醚-乙醇混合溶液和乙醚-异丙醇混合溶液两种混合溶剂对大豆毛油、菜籽毛油、大豆磷脂油、三级棉籽油、菜粕、猪配合饲料、鸡配合饲料、水产饲料等20种饲料原料及配合饲料的酸价进行了测定,通过对测定结果进行分析比较,结果表明,两种混合溶剂测定的酸价结果没有显著性差异,均可采用。 展开更多
关键词 饲料 酸价 自动电位滴定 油脂
下载PDF
电位滴定法测定冷轧含铬污泥中氯离子含量
20
作者 董礼男 张继明 +1 位作者 赵希文 朱春要 《电镀与精饰》 CAS 北大核心 2024年第11期113-119,共7页
冷轧含铬废水经过一系列化学反应、沉淀、压滤后产生的固体废弃物称为冷轧含铬污泥。其主要成分有铬的化合物、有机物及少量铜、铁、锌、镍及氯等杂质元素。近几年,国家提出针对固废资源环保处理并充分回收利用的政策,因此,准确测定有... 冷轧含铬废水经过一系列化学反应、沉淀、压滤后产生的固体废弃物称为冷轧含铬污泥。其主要成分有铬的化合物、有机物及少量铜、铁、锌、镍及氯等杂质元素。近几年,国家提出针对固废资源环保处理并充分回收利用的政策,因此,准确测定有害元素氯离子含量对含铬污泥的后续处理具有重要的指导意义。样品经高温灼烧、酸消解后,可消除各类难溶物的干扰,加碱液生成沉淀,过滤后得到的滤液,以消除共存元素铬对氯离子检测的干扰,采用硝酸银标准滴定溶液进行电位滴定。建立了电位滴定法测定含铬污泥中氯离子含量的方法,讨论了灼烧温度、消解酸、共存元素对氯离子检测的影响。确定了在800℃进行高温灼烧,分别加入15 mL硝酸、10 mL硫酸、5 mL过氧化氢对样品进行消解,加入碱液生成沉淀,得到的滤液酸化后进行仪器测定。结果表明:在仪器最佳滴定条件下,方法的检出限为0.0022%,按照本实验方法对含铬污泥中氯离子含量进行测定,检测结果的相对标准偏差(RSD,n=10)小于2.00%,加标回收率在98.30%~101.70%之间。 展开更多
关键词 冷轧含铬污泥 氯离子 电位滴定法
下载PDF
上一页 1 2 62 下一页 到第
使用帮助 返回顶部