Three types of natural soils are studied in this paper: 1) a postglacial silt, 2) a glacial till, and 3) a postglacial sand. The former two are soils from embankment dam sites in Sweden, and the latter is a soil from ...Three types of natural soils are studied in this paper: 1) a postglacial silt, 2) a glacial till, and 3) a postglacial sand. The former two are soils from embankment dam sites in Sweden, and the latter is a soil from a natural deposit situated in the Swedish east coastal region. In situ Double-ring infiltrometer (DRI) tests are compared with laboratory constant-head permeability determinations. This study shows that the DRI tests conducted on sandy-silty soils are within sufficient range to the laboratory results, to suggest that in situ near-saturated infiltration capacity may be used as a field estimate of hydraulic conductivity (permeability) for this range of soils. In situ infiltrometer testing may be the better alternative when there is difficulty in achieving representative field conditions in a laboratory setting, e.g., for widely graded soils such as glacial tills.展开更多
Insulation failure significantly contributes to the unpredictable shutdown of power equipment.Compared to the partial discharge and high-frequency(HF)injection methods,the HF common-mode(CM)leakage current method offe...Insulation failure significantly contributes to the unpredictable shutdown of power equipment.Compared to the partial discharge and high-frequency(HF)injection methods,the HF common-mode(CM)leakage current method offers a non-intrusive and highly sensitive alternative.However,the detection of HF CM currents is susceptible to interference from differential-mode(DM)currents,which exhibit high-amplitude and multifrequency components during normal operation.To address this challenge,this paper proposes a double-ring current sensor based on the principle of magnetic shielding for inverter-fed machine winding insulation monitoring.The inner ring harnesses the magnetic aggregation effect to isolate the DM current magnetic field,whereas the outer ring serves as the magnetic core of the Rogowski current sensor,enabling HF CM current monitoring.First,the magnetic field distributions of the CM and DM currents were analyzed.Then,a correlation between the sensor parameters and signal-to-noise ratio of the target HF CM current was established.Finally,an experimental study was conducted on a 3-kW PMSM for verification.The results indicate that the proposed double-ring HF CM sensor can effectively mitigate DM current interference.Compared to a single-ring sensor,a reduction of approximately 40%in the DM component was achieved,which significantly enhanced the precision of online insulation monitoring.展开更多
Compared with the traditional radial flow reactors(RFRs), the double-ring RFRs possess advantages including lower pressure drop, shorter flow path and greater flow area. According to the Ergun's equation and the c...Compared with the traditional radial flow reactors(RFRs), the double-ring RFRs possess advantages including lower pressure drop, shorter flow path and greater flow area. According to the Ergun's equation and the continuity equation, a two-dimensional hydrodynamic model was established to describe the hydrodynamic behavior in the double-ring RFRs. The successive over-relaxation(SOR) method was applied to solve the two-dimensional hydrodynamic model. The flow assignment parameters(T_i) of mass flow in the inner channel to the outer catalyst bed and the inner catalyst bed were optimized by the Powell method. Simulations showed the trend of change in gas distribution uniformity along the axial direction and the weight hourly space velocity(WHSV) with the variation of reactor size. The model can be used to analyze the reasonability of dehydrogenation reactor design, and it can also provide quantitative reference for the design of new double-ring RFRs.展开更多
Infiltration is an important part of the hydrological cycle, and it is one of the main abstractions accounted for in the rainfall-runoff modeling. The main purpose of this study is to compare the infiltration models t...Infiltration is an important part of the hydrological cycle, and it is one of the main abstractions accounted for in the rainfall-runoff modeling. The main purpose of this study is to compare the infiltration models that were used to assess the infiltration rate of the Mitidja Plain in Algeria. Field infiltration tests were conducted at 40 different sites using a double ring infiltrometer. Five statistical comparison criteria including root mean squared error(RMSE), normalized root mean squared error(NRMSE), coefficient of correlation(CC), Nash-Sutcliffe efficiency(NSE), and Kling-Gupta efficiency(KGE) were used to determine the best performing infiltration model and to confirm anomalies between predicted and observed values. Then we evaluated performance of five models(i.e., the Philip model, Kostiakov model, Modified Kostiakov model, Novel model, and Horton model) in simulating the infiltration process based on the adjusted performance parameters cited above. Results indicated that the Novel model had the best simulated water infiltration process in the Mitidja Plain in Algeria. However, the Philip model was the weakest to simulate the infiltration process. The conclusion of this study can be useful for estimating infiltration rate at various sites using a Novel model when measured infiltration data are not available and are useful for planning and managing water resources in the study area.展开更多
文摘Three types of natural soils are studied in this paper: 1) a postglacial silt, 2) a glacial till, and 3) a postglacial sand. The former two are soils from embankment dam sites in Sweden, and the latter is a soil from a natural deposit situated in the Swedish east coastal region. In situ Double-ring infiltrometer (DRI) tests are compared with laboratory constant-head permeability determinations. This study shows that the DRI tests conducted on sandy-silty soils are within sufficient range to the laboratory results, to suggest that in situ near-saturated infiltration capacity may be used as a field estimate of hydraulic conductivity (permeability) for this range of soils. In situ infiltrometer testing may be the better alternative when there is difficulty in achieving representative field conditions in a laboratory setting, e.g., for widely graded soils such as glacial tills.
基金supported in part by the National Natural Science Foundation of China under Grant 51907116in part sponsored by Natural Science Foundation of Shanghai 22ZR1425400sponsored by Shanghai Rising-Star Program 23QA1404000。
文摘Insulation failure significantly contributes to the unpredictable shutdown of power equipment.Compared to the partial discharge and high-frequency(HF)injection methods,the HF common-mode(CM)leakage current method offers a non-intrusive and highly sensitive alternative.However,the detection of HF CM currents is susceptible to interference from differential-mode(DM)currents,which exhibit high-amplitude and multifrequency components during normal operation.To address this challenge,this paper proposes a double-ring current sensor based on the principle of magnetic shielding for inverter-fed machine winding insulation monitoring.The inner ring harnesses the magnetic aggregation effect to isolate the DM current magnetic field,whereas the outer ring serves as the magnetic core of the Rogowski current sensor,enabling HF CM current monitoring.First,the magnetic field distributions of the CM and DM currents were analyzed.Then,a correlation between the sensor parameters and signal-to-noise ratio of the target HF CM current was established.Finally,an experimental study was conducted on a 3-kW PMSM for verification.The results indicate that the proposed double-ring HF CM sensor can effectively mitigate DM current interference.Compared to a single-ring sensor,a reduction of approximately 40%in the DM component was achieved,which significantly enhanced the precision of online insulation monitoring.
文摘Compared with the traditional radial flow reactors(RFRs), the double-ring RFRs possess advantages including lower pressure drop, shorter flow path and greater flow area. According to the Ergun's equation and the continuity equation, a two-dimensional hydrodynamic model was established to describe the hydrodynamic behavior in the double-ring RFRs. The successive over-relaxation(SOR) method was applied to solve the two-dimensional hydrodynamic model. The flow assignment parameters(T_i) of mass flow in the inner channel to the outer catalyst bed and the inner catalyst bed were optimized by the Powell method. Simulations showed the trend of change in gas distribution uniformity along the axial direction and the weight hourly space velocity(WHSV) with the variation of reactor size. The model can be used to analyze the reasonability of dehydrogenation reactor design, and it can also provide quantitative reference for the design of new double-ring RFRs.
基金the framework of the SWATCH project (Prima project) funded by the DGRSDT, Algeria
文摘Infiltration is an important part of the hydrological cycle, and it is one of the main abstractions accounted for in the rainfall-runoff modeling. The main purpose of this study is to compare the infiltration models that were used to assess the infiltration rate of the Mitidja Plain in Algeria. Field infiltration tests were conducted at 40 different sites using a double ring infiltrometer. Five statistical comparison criteria including root mean squared error(RMSE), normalized root mean squared error(NRMSE), coefficient of correlation(CC), Nash-Sutcliffe efficiency(NSE), and Kling-Gupta efficiency(KGE) were used to determine the best performing infiltration model and to confirm anomalies between predicted and observed values. Then we evaluated performance of five models(i.e., the Philip model, Kostiakov model, Modified Kostiakov model, Novel model, and Horton model) in simulating the infiltration process based on the adjusted performance parameters cited above. Results indicated that the Novel model had the best simulated water infiltration process in the Mitidja Plain in Algeria. However, the Philip model was the weakest to simulate the infiltration process. The conclusion of this study can be useful for estimating infiltration rate at various sites using a Novel model when measured infiltration data are not available and are useful for planning and managing water resources in the study area.