期刊文献+
共找到34篇文章
< 1 2 >
每页显示 20 50 100
Coordinated Rotor-Side Control Strategy for Doubly-FedWind Turbine under Symmetrical and Asymmetrical Grid Faults
1
作者 Quanchun Yan Chao Yuan +2 位作者 WenGu Yanan Liu Yiming Tang 《Energy Engineering》 EI 2023年第1期49-68,共20页
In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of ro... In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of rotor side converter of the doubly-fed generator is proposed.When the power grid voltage drops symmetrically,the generator approximate equation under steady-state conditions is no longer applicable.Considering the dynamic process of stator current excitation,according to the change of stator flux and the depth of voltage drop,the system can dynamically provide reactive power support for parallel nodes and suppress the rise of DC side voltage and rotor over-current.When the grid voltage drops asymmetrically,the positive and negative sequence components are separated in the rotating coordinate system.The doubly fed generator model is established to suppress the rotor positive sequence current and negative sequence current respectively.At the same time,the output voltage limit of the converter is discussed,and the reference value is adjusted within the allowable output voltage range.In order to adapt to the occurrence of different types of power grid faults and complex operating conditions,a fast switching module of fault type detection and rotor control mode is designed to detect the type of power grid faults and voltage drop depth in real time and switch the rotor side control mode dynamically.Finally,the simulation model of the doubly fed wind turbine is constructed in Matlab/Simulink.The simulation results verify that the proposed control strategy can improve the low-voltage ride through performance of the system when dealing with the symmetrical and asymmetric voltage drop of the power grid and identify the power grid fault type and provide the correct control strategy. 展开更多
关键词 doubly-fed wind turbines symmetrical faults asymmetrical faults low voltage ride through rotor side control fault type detection
下载PDF
A novel control strategy of a variable-speed doubly-fed-induction-generator-based wind energy conversion system
2
作者 Shibani Prasad Mohapatra Pradipta Kishore Dash 《Clean Energy》 EI CSCD 2024年第1期153-170,共18页
This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction g... This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction generator-based variable-speed wind turbine by controlling the rotor current. In the first step, a maximum power point tracking technique is used to extract the maximum power from theturbine. Then a stator-flux-oriented vector control strategy is employed to control the rotor-side current. Subsequently, a grid voltagevector-oriented control strategy is used to control the grid-side system of the grid-connected generator. Considering the nonlinearityand parameter uncertainty of the system, an active disturbance rejection controller with a sliding-mode-based extended-state observeris developed for the above-mentioned control strategies. Furthermore, the stability of the controller is tested and the performance of thecontroller is compared with the classical proportional-integral controller based on disturbance rejection, robustness and tracking capability in a highly non-linear wind speed variation scenario. Modelling, control and comparison are conducted in the MATLAB®/Simulink®environment. Finally, a real-time hardware set-up is presented using the dSPACE ds-1104 R&D processing board to validate the controlscheme. From the result of the experiments, it is seen that the proposed controller takes 10-15 control cycles to settle to its steady-statevalues, depending on the control loop, whereas the conventional proportional-integral controller takes 60-75 control cycles. As a result,the settling time for the proposed control scheme is shorter than that of the proportional-integral controller. 展开更多
关键词 doubly-fed induction generator variable-speed wind turbine vector control active disturbance rejection controller stability analysis
原文传递
Dynamic modelling and robust current control of wind-turbine driven DFIG during external AC voltage dip 被引量:10
3
作者 HU Jia-bing HE Yi-kang 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第10期1757-1764,共8页
Doubly-Fed Induction Generator (DFIG), with vector control applied, is widely used in Variable-Speed Constant- Frequency (VSCF) wind energy generation system and shows good performance in maximum wind energy captu... Doubly-Fed Induction Generator (DFIG), with vector control applied, is widely used in Variable-Speed Constant- Frequency (VSCF) wind energy generation system and shows good performance in maximum wind energy capture. But in two traditional vector control schemes, the equivalent stator magnetizing current is considered invariant in order to simplify the rotor current inner-loop controller. The two schemes can perform very well when the grid is in normal condition. However, when grid disturbance such as grid voltage dip or swell fault occurs, the control performance worsens, the rotor over current occurs and the Fault Ride-Through (FRT) capability of the DFIG wind energy generation system gets seriously deteriorated. An accurate DFIG model was used to deeply investigate the deficiency of the traditional vector control. The improved control schemes of two typical traditional vector control schemes used in DFIG were proposed, and simulation study of the proposed and traditional control schemes, with robust rotor current control using Internal Model Control (IMC) method, was carded out. The validity of the proposed modified schemes to control the rotor current and to improve the FRT capability of the DFIG wind energy generation system was proved by the comparison study. 展开更多
关键词 wind energy generation Variable-Speed Constant-Frequency (VSCF) doubly-fed Induction Generator (DFIG) Fault Ride-Through (FRT) Internal Model Control (IMC)
下载PDF
Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions 被引量:2
4
作者 Jia-bing HU Yi-kang HE Lie XU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第12期1731-1740,共10页
This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positiv... This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positive and negative synchronous reference frames is presented. Variations of the stator output active and reactive powers are fully deduced in the presence of negative sequence supply voltage and rotor flux. An enhanced DPC scheme is proposed to eliminate stator active power oscillation during network unbalance. The proposed control scheme removes rotor current regulators and the decomposition processing of positive and negative sequence rotor currents. Simulation results using PSCAD/EMTDC are presented on a 2-MW DFIG wind power generation system to validate the feasibility of the proposed control scheme under balanced and unbalanced network conditions. 展开更多
关键词 doubly-fed induction generator (DFIG) wind turbine Direct power control (DPC) Stator voltage oriented (SVO) Unbalanced network
下载PDF
Model of DFIG Wind Farm and Study on Its LVRT Capability 被引量:1
5
作者 He Guo Ding-Zhong Huang +1 位作者 Li-Gang Gu Fang-Yuan Wu 《Journal of Electronic Science and Technology》 CAS 2013年第1期78-83,共6页
As a typical clean and renewable energy, wind power is becoming more and more widely used in electrical industry. However, its characteristics of random and intermittent have brought serious problems to the power syst... As a typical clean and renewable energy, wind power is becoming more and more widely used in electrical industry. However, its characteristics of random and intermittent have brought serious problems to the power system, such as voltage fluctuation and insufficient reactive power. Based on the K-means clustering algorithm, this paper classifies the doubly-fed induction generators (DFIG) according to the operation of propeller pitch angle control. At the same time, to obtain the optimal parameter, advanced particle swarm optimization (PSO) is used. Then the dynamic model of DFIG under the network fault condition is built. What is more, the role that crowbar circuit plays in low voltage ride through (LVRT) is discussed. Finally, simulations in DigSILENT verify the model. 展开更多
关键词 CROWBAR doubly-fed induction generators low voltage ride through MODEL wind turbine.
下载PDF
A Long-Range Generalized Predictive Control Algorithm for a DFIG Based Wind Energy System 被引量:1
6
作者 J.S.Solis-Chaves Lucas L.Rodrigues +1 位作者 C.M.Rocha-Osorio Alfeu J.Sguarezi Filho 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第5期1209-1219,共11页
This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based. This controller uses the state space equations t... This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based. This controller uses the state space equations that consider the rotor current and voltage as state and control variables, to execute the predictive control action. Therefore, the model of the plant must be transformed into two discrete transference functions, by means of an auto-regressive moving average model, in order to attain a discrete and decoupled controller, which makes it possible to treat it as two independent single-input single-output systems instead of a magnetic coupled multiple-input multiple-output system. For achieving that, a direct power control strategy is used, based on the past and future rotor currents and voltages estimation. The algorithm evaluates the rotor current predictors for a defined prediction horizon and computes the new rotor voltages that must be injected to controlling the stator active and reactive powers. To evaluate the controller performance, some simulations were made using Matlab/Simulink. Experimental tests were carried out with a small-scale prototype assuming normal operating conditions with constant and variable wind speed profiles. Finally, some conclusions respect to the dynamic performance of this new controller are summarized. 展开更多
关键词 Direct power CONTROL doubly-fed INDUCTION generator flux oriented CONTROL generalized PREDICTIVE CONTROL LONG-RANGE PREDICTIVE CONTROL wind energy systems
下载PDF
Overview of Sub-synchronous Oscillation in Wind Power System 被引量:1
7
作者 Han Chen Chunlin Guo +1 位作者 Jianting Xu Pengxin Hou 《Energy and Power Engineering》 2013年第4期454-457,共4页
Nowadays with the improvement in the degree of emphasis on new energy, the wind power system has developed more and more rapidly over the world. Usually the wind plants are located in the remote areas which are far fr... Nowadays with the improvement in the degree of emphasis on new energy, the wind power system has developed more and more rapidly over the world. Usually the wind plants are located in the remote areas which are far from the load centers. Generally series compensated AC transmission and high voltage DC transmission are made use of to improve the transmission capacity as two main effective ways which can solve the problem of large scale wind power transmission. The paper describes the three kinds of impact varieties and impact mechanisms in the sub-synchronous oscillation phenomena of wind power system based on doubly fed induction generator (DFIG) wind generators. At last, we point out the important problem that should be stressed in the wind power system. 展开更多
关键词 Sub-synchronous Oscillation (SSO) Sub-synchronous Resonance(SSR) Sub-Synchronous Torsional INTERACTIONS (SSTI) Sub-Synchronous Control INTERACTIONS (SSCI) wind Turbines doubly-fed Induction Generator
下载PDF
New energy power generation-wind power generation 被引量:1
8
作者 HAN Chen-xi ZHANG Si-han 《Journal of Energy and Power Engineering》 2009年第9期45-48,共4页
This paper introduced the status quo of wind power and wind power generation technology. Focusing on the introduction of wind power generating system ibrational self-consistent field(VSCF), program implementation in... This paper introduced the status quo of wind power and wind power generation technology. Focusing on the introduction of wind power generating system ibrational self-consistent field(VSCF), program implementation included Alternating Current (AC)-Direct Current (DC)-AC conversion system, magnetic field modulation generator system, doubly-fed generator system etc. Among these, doubly-fed generator system is the trend. Where to build the wind farm is very important, so a perfect site is needed. Wind power generation will have a bright future. As long as the wind power can be linked to the grid in large scale. 展开更多
关键词 wind power generation VSCF doubly-fed generator system wind farm site
下载PDF
Analysis on Effect of Parameters of Different Wind Generator on Power Grid Transient Stability
9
作者 Zhi-wei Wen Li Ding Shi-en He 《Energy and Power Engineering》 2013年第4期363-367,共5页
To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different... To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different wind farm integration on grid typically in China has been presented. The influence of the variations of transient reactance, negative sequence reactance and rotary inertia on critical clearing time of power system transient stability is analyzed by time-domain simulation. Mixture operation of DFIG and PMSG to optimize the stability of system has been analyzed firstly. The digital simulation results show that doubly-fed induction wind turbines is a better choice to meet the requirement of system instability due to large wind farm integration in comparison with direct-drive PM synchronous wind turbines. With a rather large rotary inertia, the proper ratio of direct-drive PM synchronous wind turbines used in wind farm could be comprehensive planning by optimized the stability of system. Analysis of this paper should be provided as academic reference for improving design of wind farm system. 展开更多
关键词 wind FARM doubly-fed Induction GENERATOR DIRECT-DRIVE PM SYNCHRONOUS GENERATOR Parameter
下载PDF
Fault Ride-Through Study of Wind Turbines
10
作者 Xinyan Zhang Xuan Cao +1 位作者 Weiqing Wang Chao Yun 《Journal of Power and Energy Engineering》 2013年第5期25-29,共5页
The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT ope... The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT operation of the wind farms, three methods were discussed. First, the rotor short current of doubly-fed induction generator (DFIG) was limited by introducing a rotor side protection circuit. Second, the voltage of DC bus was limited by a DC energy absorb circuit. Third, STATCOM was used to increase the low level voltages of the wind farm. Simulation under MATLAB was studied and the corresponding results were given and discussed. The methods proposed in this paper can limit the rotor short current and the DC voltage of the DFIG WT to some degree, but the voltage support to the power system during the fault largely depend on the installation place of STATCOM. 展开更多
关键词 wind Energy FAULT Ride-Through doubly-fed INDUCTION Generator wind FARM
下载PDF
Coordination between Fault-Ride-Through Capability and Over-current Protection of DFIG Generators for Wind Farms
11
作者 B. Bak-Jensen T.A. Kawady M.H. Abdel-Rahman 《Journal of Energy and Power Engineering》 2010年第4期20-29,共10页
Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capa... Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaafarana, Egypt. The simulation results show the influence of the FRT capability on the protective relaying coordination in wind farms, showing that the FRT may work in situations where is were expected not to work, and then disabling the over-current protection, which should have worked in this situation. 展开更多
关键词 wind farms protection dynamic modeling MATLAB-SIMULINK FUSE doubly-fed induction generators
下载PDF
Simulation of grid tracking control of power system connection and maximum power brushless doubly-fed generator in point wind 被引量:1
12
作者 Hicham SERHOUD Djilani BENATTOUS 《Frontiers in Energy》 SCIE CSCD 2013年第3期380-387,共8页
In this paper, based on the analysis of the mathematical model in a common synchronous reference frame of the brushless doubly-fed generator (BDFG), the grid connection strategy and maximum energy extraction control... In this paper, based on the analysis of the mathematical model in a common synchronous reference frame of the brushless doubly-fed generator (BDFG), the grid connection strategy and maximum energy extraction control were both analyzed. Besides, the transient simula- tion of no-load model and generation model of the BDFG have been developed on the MATLAB/Simulink platform. The test results during cutting-in grid confirmed the good dynamic performance of grid synchronization and effective power control approach for the BDFG-based variable speed wind turbines. 展开更多
关键词 brushless doubly-fed generator (BDFG) modeling grid connection control back-to-back pulse- width modulation (PWM) converter wind power generation
原文传递
Design and analysis of a dual-stator brushless doubly-fed induction machine with a staggered dual-cage rotor 被引量:3
13
作者 CHENG Ming ZENG Yu +1 位作者 YAN XiaoMing ZHANG ChangGuo 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2022年第6期1318-1329,共12页
In this paper,a new dual-stator brushless doubly-fed induction machine with a staggered dual cage rotor is proposed,with emphasis on the general interconnection rule of the conductor bars for the staggered dual cage r... In this paper,a new dual-stator brushless doubly-fed induction machine with a staggered dual cage rotor is proposed,with emphasis on the general interconnection rule of the conductor bars for the staggered dual cage rotor.Since the squirrel cage rotor offers the merits of robustness,reliable structure,high slot filling factor,and low rotor resistance comparing to the wound rotor,it is introduced to the dual-stator brushless doubly-fed induction machine to solve the problems of high copper loss and unreliable rotor structure for the dual-stator brushless doubly-fed induction machine with a wound rotor.The originality of this article is to investigate the interconnection rule of conductor bars between the inner and outer cages.The constraint condition that is supposed to be satisfied is deduced by using the rotating magneto-motive force theory,based on which diverse slot/pole combinations are investigated.The performance comparison between the existing and proposed machines is conducted.Finally,a prototype is designed and fabricated.The experimental results verify the effectiveness of the proposed topology. 展开更多
关键词 brushless doubly-fed machine dual cage rotor DESIGN wind power generation
原文传递
Doubly-fed induction generator drive based WECS using fuzzy logic controller 被引量:1
14
作者 Abdelhak DIDA Djilani BEN ATTOUS 《Frontiers in Energy》 SCIE CSCD 2015年第3期272-281,共10页
The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The cont... The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The control of the rotor-side converter is realized by stator flux oriented control, whereas the control of the grid-side converter is performed by a control strategy based on grid voltage orientation to maintain the DC-link voltage stability. An intelligent fuzzy inference system is proposed as an alternative of the conventional proportional and integral (PI) controller to overcome any disturbance, such as fast wind speed variation, short grid voltage fault, parameter variations and so on. Five fuzzy logic controllers are used in the rotor side converter (RSC) for maximum power point tracking (MPPT) algorithm, active and reactive power control loops, and another two fuzzy logic controllers for direct and quadratic rotor currents components control loops. The performances have been tested on 1.5 MW doubly-fed induction generator (DFIG) in a Matlab/Simulink software environment. 展开更多
关键词 fuzzy logic wind turbine vector control doubly-fed induction generator (DFIG)
原文传递
Stability Enhancement of Small-Scale Power Grid with Renewable Power Sources by Variable Speed Diesel Power Plant
15
作者 Rion Takahashi Atsushi Umemura Junji Tamura 《Journal of Power and Energy Engineering》 2020年第3期1-17,共17页
This paper proposes a power control method to improve a stability of a small-scale power grid with renewable energy sources. In an isolated small- scale power grid such as an island, diesel power plant is main power s... This paper proposes a power control method to improve a stability of a small-scale power grid with renewable energy sources. In an isolated small- scale power grid such as an island, diesel power plant is main power source which has an environmental burden and expensive running cost due to high priced fossil fuel. Thus, expanding installation of the renewable energy sources such as a wind power is strongly desirable. Such fluctuating energy sources, however, harm power quality of the small-scale power grid, and in addition, conventional power plant in the small-scale power grid cannot, in general, stabilize the grid system with such fluctuating power sources. In this study, Variable Speed Doubly-Fed Induction Generator (VS-DFIG) is proposed to be in-stalled at a diesel power plant instead of a conventional Fixed Speed Synchronous Generator (FS-SG), because quick control of a power balance in the small-scale power grid can be achieved by using the inertial energy of VS-DFIG. In addition, utilization of a Battery Energy Storage System (BESS) is also considered to assist cooperatively the VS-DFIG control. As a result of the simulation analysis by using the proposed method, it is verified that frequency fluctuations due to renewable energy source can be effectively reduced by quick power control of the VS-DFIG compared to the conventional FS-SG, and further control ability can be obtained by utilizing BESS. Moreover, the transient stability of a small-scale power grid during a grid fault can also be enhanced. 展开更多
关键词 SMALL-SCALE POWER Grid Variable Speed doubly-fed Induction Generator (VS-DFIG) DIESEL POWER Plant wind POWER Battery Energy Storage System (BESS)
下载PDF
Fault-tolerant control of an open-winding brushless doublyfed wind power generator system with dual three-level converter
16
作者 Shi JIN Long SHI +2 位作者 Sul ADEMI Yue ZHANG Fengge ZHANG 《Frontiers in Energy》 SCIE CSCD 2023年第1期149-164,共16页
To improve the fault redundancy capability for the high reliability requirement of a brushless doubly-fed generation system applied to large offshore wind farms,the control winding of a brushless doubly-fed reluctance... To improve the fault redundancy capability for the high reliability requirement of a brushless doubly-fed generation system applied to large offshore wind farms,the control winding of a brushless doubly-fed reluctance generator is designed as an open-winding structure.Consequently,the two ends of the control winding are connected via dual three-phase converters for the emerging open-winding structure.Therefore,a novel fault-tolerant control strategy based on the direct power control scheme is brought to focus in this paper.Based on the direct power control(DPC)strategy,the post-fault voltage vector selection method is explained in detail according to the fault types of the dual converters.The fault-tolerant control strategy proposed enables the open-winding brushless doubly-fed reluctance generator(BDFRG)system to operate normally in one,two,or three switches fault of the converter,simultaneously achieving power tracking control.The presented results verify the feasibility and validity of the scheme proposed. 展开更多
关键词 open-winding brushless doubly-fed reluctance generator(BDFRG) direct power control faulttolerant control multi-level converter wind power
原文传递
Low-voltage ride-through capability improvement of Type-3 wind turbine through active disturbance rejection feedback control-based dynamic voltage restorer
17
作者 El Mahfoud Boulaoutaq Asma Aziz +3 位作者 Abdelmounime El Magri Ahmed Abbou Mohamed Ajaamoum Azeddine Rachdy 《Clean Energy》 EI CSCD 2023年第5期1091-1109,共19页
Disconnections due to voltage drops in the grid cannot be permitted if wind turbines(WTs)contribute significantly to electricity pro-duction,as this increases the risk of production loss and destabilizes the grid.To m... Disconnections due to voltage drops in the grid cannot be permitted if wind turbines(WTs)contribute significantly to electricity pro-duction,as this increases the risk of production loss and destabilizes the grid.To mitigate the negative effects of these occurrences,WTs must be able to ride through the low-voltage conditions and inject reactive current to provide dynamic voltage support.This paper investigates the low-voltage ride-through(LVRT)capability enhancement of a Type-3 WT utilizing a dynamic voltage restorer(DVR).During the grid voltage drop,the DVR quickly injects a compensating voltage to keep the stator voltage constant.This paper proposes an active disturbance rejection control(ADRC)scheme to control the rotor-side,grid-side and DVR-side converters in a wind–DVR integrated network.The performance of the Type-3 WT with DVR topology is evaluated under various test conditions using MATLAB®/Simulink®.These simulation results are also compared with the experimental results for the LVRT capability performed on a WT emulator equipped with a crowbar and direct current(DC)chopper.The simulation results demonstrate a favourable transient and steady-state response of the Type-3 wind turbine quantities defined by the LVRT codes,as well as improved reactive power support under balanced fault conditions.Under the most severe voltage drop of 95%,the stator currents,rotor currents and DC bus voltage are 1.25 pu,1.40 pu and 1.09 UDC,respectively,conforming to the values of the LVRT codes.DVR controlled by the ADRC technique significantly increases the LVRT capabilities of a Type-3 doubly-fed induction generator-based WT under symmetrical voltage dip events.Although setting up ADRC controllers might be challenging,the proposed method has been shown to be extremely effective in reducing all kinds of internal and external disturbances. 展开更多
关键词 active disturbance rejection controller(ADRC) dynamic voltage restorer(DVR) low-voltage ride-through(LVRT) Type-3 wind turbines(WTs) doubly-fed induction generator(DFIG)
原文传递
Field validation of generic wind park models using fault records 被引量:3
18
作者 Aboutaleb HADDADI Ilhan KOCAR +3 位作者 Thomas KAUFFMANN Ulas KARAAGAC Evangelos FARANTATOS Jean MAHSEREDJIAN 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2019年第4期826-836,共11页
A challenge faced by protection and planning engineers is the development and validation of accurate wind turbine generator(WTG)models to study the impact of increasing wind integration on system protection.Thispaper ... A challenge faced by protection and planning engineers is the development and validation of accurate wind turbine generator(WTG)models to study the impact of increasing wind integration on system protection.Thispaper is on the experimental validation of a generic electromagnetic transient-type(EMT-type)model of aggregated WTGs or wind parks suitable for transient studies.The phasor domain equivalent of the generic model,suitable for protection tools based on steady-state solvers,is also considered.The model has been validated using two sets of actual relay records for the fault response of two wind parks consisting of Type-III WTGs and connected to115 kV and 230 kV transmission systems.The objective is to show that the generic model can reproduce the actual fault response in simulations,and protection engineers can obtain accurate models of wind parks using fault records.A distinctive characteristic of a WTG is its substantially different negative sequence fault current contribution compared to a synchronous generator.The paper shows that the generic model provides enough options to reproduce the negative sequence behavior and hence is suitable for fault studies involving negative sequence-based protection. 展开更多
关键词 Renewable generation wind turbine GENERATOR doubly-fed induction GENERATOR SHORT-CIRCUIT analysis Electromagnetic transient-type MODEL PHASOR domain MODEL
原文传递
On the State-dependent Switched Energy Functions of DFIG-based Wind Power Generation Systems 被引量:4
19
作者 Yang Liu Zehui Lin +2 位作者 Kaishun Xiahou Mengshi Li Q.H.Wu 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第2期318-328,共11页
This paper proposes a novel state-dependent switched energy function(SdSEF)for general nonlinear autonomous systems,and constructs an SdSEF for doubly-fed induction generator(DFIG)-based wind power generation systems(... This paper proposes a novel state-dependent switched energy function(SdSEF)for general nonlinear autonomous systems,and constructs an SdSEF for doubly-fed induction generator(DFIG)-based wind power generation systems(WPGSs).Different from the conventional energy function,SdSEF is a piece-wise continuous function,and it satisfies the conditions of conventional energy functions on each of its continuous segments.SdSEF is designed to bridge the gap between the well-developed energy function theory and the description of system energy of complex nonlinear systems,such as power electronics converter systems.The stability criterion of nonlinear autonomous systems is investigated with SdSEF,and mathematical proof is presented.The SdSEF of a typical DFIGbased WPGS is simulated in the whole processes of a grid fault and fault recovery.Simulation results verify the negativeness of the derivative of each continuous segment of the SdSEF. 展开更多
关键词 doubly-fed induction generator state-dependent switched energy function wind power generation system
原文传递
Three-phase fault direction identification method for outgoing transmission line of DFIG-based wind farms 被引量:2
20
作者 Zhanfeng FAN Guobing SONG +2 位作者 Xiaoning KANG Jisi TANG Xiaobo WANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2019年第5期1155-1164,共10页
Doubly-fed induction generator(DFIG)-based wind farm has the characteristic of transient fault with low voltage ride through(LVRT)capability.A new three-phase fault direction identification method for the outgoing tra... Doubly-fed induction generator(DFIG)-based wind farm has the characteristic of transient fault with low voltage ride through(LVRT)capability.A new three-phase fault direction identification method for the outgoing transmission line of the wind farm is presented.The ability of the new directional relay to differentiate between a three-phase fault in one direction or the other is obtained by using the increment of phase angle difference between the memory voltage signal and the fault current signal within a certain time,and using the amplitude variation of the fault current.It can be inferred that the fault current is supplied by the wind farm whether the phase angle differs or the current amplitude varies considerably.Different fault locations at the outgoing transmission line have been simulated by PSCAD/EMTDC to evaluate the reliability and sensitivity of the proposed technique.Results show that the new directional relay is of faster response when a three-phase fault occurs at the outgoing transmission line of a DFIG-based wind farm. 展开更多
关键词 wind FARM doubly-fed induction generator(DFIG) Directional relay OUTGOING transmission line
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部