期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
10kV变压器铁心剖面参数化绘图设计 被引量:1
1
作者 王波 代艳霞 +2 位作者 邹昕珂 姚礼 符纯华 《机械工程师》 2013年第10期83-85,共3页
在AutoCAD中使用LISP语言二次开发对配电变压器铁心剖面图的参数化设计,通过传入的铁心片宽表与叠厚表数据,程序自动选择绘图比例与图幅大小,并完成铁心剖面图的自动绘制与标注。该工具实现了制图的自动化,提高了机械制图的绘图效率,具... 在AutoCAD中使用LISP语言二次开发对配电变压器铁心剖面图的参数化设计,通过传入的铁心片宽表与叠厚表数据,程序自动选择绘图比例与图幅大小,并完成铁心剖面图的自动绘制与标注。该工具实现了制图的自动化,提高了机械制图的绘图效率,具有较好的实际使用价值和推广意义。 展开更多
关键词 变压器铁心 参数化设计 剖面图
下载PDF
Current-limiting characteristics of saturated iron-core fault current limiters in VSC-HVDC systems based on electromagnetic energy conversion mechanism 被引量:7
2
作者 Botong LI Hanqing CUI +2 位作者 Fangjie JING Bin LI Yichao LIU 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2019年第2期412-421,共10页
A common method to examine the current-limiting performance of saturated iron-core fault current limiter(SI-FCL) in high-voltage direct-current transmission based on voltage source converter(VSC-HVDC) systems is to so... A common method to examine the current-limiting performance of saturated iron-core fault current limiter(SI-FCL) in high-voltage direct-current transmission based on voltage source converter(VSC-HVDC) systems is to solve differential equations based on the system fault transient characteristics and the equivalent inductance calculation equation. This method analyzes the fault current of the VSC-HVDC system in the time domain. However, it is computationally complex and cannot directly reflect the relationship between parameters and the currentlimiting effect of the SI-FCL.In this paper,the relationship between the magnetic flux density and magnetic field energy of the SI-FCL is analyzed. The energy exchange between the DC capacitor and the SI-FCL in the DC short circuit fault process is analyzed. From the perspective of electromagnetic energy conversion, the criterion for determining the current-limiting ability of the SI-FCL in the transient process is given based on the parameters of the SI-FCL and VSC-HVDC system. On this basis, the characteristics of the DC side fault current and the capacitor voltage when the SI-FCL has current-limiting ability are examined.Based on the parameters of the SI-FCL and VSC-HVDC system, a method for calculating the fault current peak value and capacitor voltage drop time is given. Finally, the accuracy of the analysis of the SI-FCL in the VSC-HVDC system based on the electromagnetic energy conversion mechanism is demonstrated through a case study and simulation results of the VSC-HVDC system with different SI-FCLs. 展开更多
关键词 ELECTROMAGNETIC energy Saturated iron-core FAULT current limiter(SI-FCL) HIGH-VOLTAGE direct-current transmission based on voltage source converter(VSCHVDC) system FAULT analysis
原文传递
Analysis and Design of the Iron Core as the Arc Snubber in the EAST NBI System 被引量:1
3
作者 黄懿贇 李伟 +2 位作者 王俊傢 高阳 张健 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第3期330-334,共5页
A special winding iron-core is designed to act as the snubber for the neutral beam injection (NBI) power supply (PS) system in EAST, which will limit the fault current and energy caused by occasional sparking in t... A special winding iron-core is designed to act as the snubber for the neutral beam injection (NBI) power supply (PS) system in EAST, which will limit the fault current and energy caused by occasional sparking in the NBI ion source. 50-50 Ni-Fe is chosen as the high-frequency magnetization material for the iron-core. Equations for the snubber is derived from the design of the iron-core. The iron-loss factor and eddy-current losses are found to increase in a sample experiment at a frequency from 1 kHz to 20 kHz. A 1:10 miniature of the iron-core is tested and performs well with a fine capability. 展开更多
关键词 iron-core snubber NBI NI-FE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部