Drift phenomenon has been known as the drawback of sensors and causes inaccuracy on the long-term measurement. In general,there are two methods to reduce the drift problem.One is to tune the parameters of the fabricat...Drift phenomenon has been known as the drawback of sensors and causes inaccuracy on the long-term measurement. In general,there are two methods to reduce the drift problem.One is to tune the parameters of the fabrication process to improve the properties of the front-ended device.Another is to compensate the drift phenomenon by adding extra drift compensation circuit or software in the back-ended readout circuit.In this study,a drift calibration method for the potentiometric sensor was presented and the drift calibration method was performed by using the circuit.According to experimental results,the drift phenomenon of the SnO_2 pH electrode was reduced by the drift calibration device.展开更多
A method is proposed to compensate the output drift for cooled infrared imaging systems at various ambient temperatures. By calibrating the cryogenic infrared detector which absorbs the radiant flux of blackbody direc...A method is proposed to compensate the output drift for cooled infrared imaging systems at various ambient temperatures. By calibrating the cryogenic infrared detector which absorbs the radiant flux of blackbody directly, the internal factors can be obtained. Then, by combining the calibration result of infrared imaging system at an arbitrary ambient temperature, the output drift can be calculated and compensated at various integration time and ambient temperatures. Experimental results indicate that the proposed method can eliminate the effect of ambient temperature fluctuation on the system output efficiently.展开更多
文摘Drift phenomenon has been known as the drawback of sensors and causes inaccuracy on the long-term measurement. In general,there are two methods to reduce the drift problem.One is to tune the parameters of the fabrication process to improve the properties of the front-ended device.Another is to compensate the drift phenomenon by adding extra drift compensation circuit or software in the back-ended readout circuit.In this study,a drift calibration method for the potentiometric sensor was presented and the drift calibration method was performed by using the circuit.According to experimental results,the drift phenomenon of the SnO_2 pH electrode was reduced by the drift calibration device.
文摘A method is proposed to compensate the output drift for cooled infrared imaging systems at various ambient temperatures. By calibrating the cryogenic infrared detector which absorbs the radiant flux of blackbody directly, the internal factors can be obtained. Then, by combining the calibration result of infrared imaging system at an arbitrary ambient temperature, the output drift can be calculated and compensated at various integration time and ambient temperatures. Experimental results indicate that the proposed method can eliminate the effect of ambient temperature fluctuation on the system output efficiently.