期刊文献+
共找到2,908篇文章
< 1 2 146 >
每页显示 20 50 100
Ordered mesoporous materials for water pollution treatment:Adsorption and catalysis
1
作者 Peng Zhang Mingming He +4 位作者 Wei Teng Fukuan Li Xinyuan Qiu Kexun Li Hao Wang 《Green Energy & Environment》 SCIE EI CAS CSCD 2024年第8期1239-1256,共18页
To meet the growing emission of water contaminants,the development of new materials that enhance the efficiency of the water treatment system is urgent.Ordered mesoporous materials provide opportunities in environment... To meet the growing emission of water contaminants,the development of new materials that enhance the efficiency of the water treatment system is urgent.Ordered mesoporous materials provide opportunities in environmental processing applications due to their exceptionally high surface areas,large pore sizes,and enough pore volumes.These properties might enhance the performance of materials concerning adsorption/catalysis capability,durability,and stability.In this review,we enumerate the ordered mesoporous materials as adsorbents/catalysts and their modifications in water pollution treatment from the past decade,including heavy metals(Hg^(2+),Pb^(2+),Cd^(2+),Cr^(6+),etc.),toxic anions(nitrate,phosphate,fluoride,etc.),and organic contaminants(organic dyes,antibiotics,etc.).These contributions demonstrate a deep understanding of the synergistic effect between the incorporated framework and homogeneous active centers.Besides,the challenges and perspectives of the future developments of ordered mesoporous materials in wastewater treatment are proposed.This work provides a theoretical basis and complete summary for the application of ordered mesoporous materials in the removal of contaminants from aqueous solutions. 展开更多
关键词 water pollution treatment Ordered mesoporous materials Toxic contaminants ADSORPTION CATALYSIS
下载PDF
Integrated Control of Agricultural Non-point Source Pollution to Provide Safe and Healthy Drinking Water for Rural Areas 被引量:5
2
作者 Qi LIANG Zhen ZHANG +5 位作者 Yongxian LIU Jinghao DAI Ziju JIANG Liping PAN Shiyang LU Xiu LAN 《Asian Agricultural Research》 2017年第9期28-30,35,共4页
Agricultural non-point source pollution has become the main part of water pollution prevention and control in China. This paper made a brief introduction to the causes and hazards of agricultural non-point source poll... Agricultural non-point source pollution has become the main part of water pollution prevention and control in China. This paper made a brief introduction to the causes and hazards of agricultural non-point source pollution and the current situation of agricultural non-point source pollution prevention and control in China. In view of the serious agricultural non-point source pollution in water environment of Guangxi and the difference in quality of drinking water between urban and rural areas,it came up with recommendations for strengthening agricultural non-point source pollution prevention and control from scientific distribution,linked operation and maintenance,popular science education,and legal system construction,to guarantee safe and healthy drinking water in rural areas. 展开更多
关键词 Non-point source pollution AGRICULTURE water environment drinking water safety
下载PDF
Evaluation of Drinking Water Pollution and Health Effects in Baghdad, Iraq 被引量:1
3
作者 Allaa M. Aenab S. K. Singh 《Journal of Environmental Protection》 2012年第6期533-537,共5页
Contamination of water reserves by biological, chemical, and radiologic agents may affect the health of millions of residents in the Iraq as well as many others throughout the world. Fatal outbreaks of cholera struck ... Contamination of water reserves by biological, chemical, and radiologic agents may affect the health of millions of residents in the Iraq as well as many others throughout the world. Fatal outbreaks of cholera struck several provinces of the country, including Baghdad. The United Nations Environment Programme (UNEP) also says air pollution, resulting from burning oil and aggravated by war, is cause for concern. The study area Baghdad has been divided into two parts: Central Baghdad and Outskirts of Baghdad (included in Baghdad but near the boundaries of Baghdad). The outskirts of Baghdad comprises of 4 cities: Al-Hussaniya located in northern part of Baghdad, Abu-Gurabe located in the western side of Baghdad, Jissr Diyala located in the eastern side of Baghdad and finally Al-Mahmodiya located in the southern side of Baghdad. These cities are in very poor situation in terms of water supply. The quality of water supplied is bad as no attention is given to WTP's in these places, which is also because of the fact that given the insecure war conditions, these areas are inaccessible. The sewage is thrown directly into the river because these areas do not have sewage treatment plants. In case of central Baghdad the water supply and sewerage network are broken in some places. Due to this there is mixing of water between the two networks. For this study we taking water supply samples and collect all the samples from WTPs and water supply network (houses, shops and different places). We made the analysis to parts first bacteriologies, second chlorine and after analysis these samples in lab we will give in our study numbers of fail samples, type of diseases and how many case during year 2007 in Baghdad City. Also in this study we will give Estimated Deaths from Water-Related Diseases 2010 to 2035. 展开更多
关键词 drinking water water pollution water Supply drinking water NETWORK SEWERAGE NETWORK WTP’s Wastewater Iraq Environment and water-BORNE Diseases
下载PDF
Genotoxicity evaluation and a primary risk assessment of organic pollutants in the drinking water sources of Nanjing, China 被引量:6
4
作者 LI Yi-qiang WU Yu-lin +1 位作者 CHEN Yuan-gao KONG Zhi-ming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第5期983-988,共6页
An increasing number of industrial, agricultural, and commercial chemicals in the aquatic environment leads to various deleterious effects on organisms, which is becoming an increasingly serious problem in China. In t... An increasing number of industrial, agricultural, and commercial chemicals in the aquatic environment leads to various deleterious effects on organisms, which is becoming an increasingly serious problem in China. In this study, the comet assay was conducted to investigate the genotoxicity to human body caused by organic concentrates in the drinking water sources of Nanjing City from Yangtze River of China, and health and ecology risk due to expose to these organic pollutants were evaluated with the multimedia environmental assessment system (MEAS). For all the water samples, they were collected from four different locations in the drinking water sourcr samples, es of Nanjing City. The results of the comet assay showed that all the organic concentrates from the water samples could induce different levels DNA damages on human peripheral blood lymphocytes, and a statistically significant difference (p〈0.01) was observed compared with the solvent control, which demonstrated the genotoxicity was in existence. According to the ambient severity (AS) of individual compound, we had sorted out the main organic pollutants in the drinking water source of the four waterworks, and the results showed that there was some potential hazard to human body for all the source water, namely the total ambient severity (TAS) of health for each water source was more than 1. However, the TAS of ecology for each water source was less than 1, which indicated that it was safe to ecology. The results of this investigation demonstrate the application of the comet assay and the MEAS in aquatic environmental monitoring studies, and the comet assay found to be fast, sensitive, and suitable for genotoxicity monitoring programs of drinking water source. 展开更多
关键词 GENOTOXICITY comet assay risk assessment organic pollutants drinking water sources Nanjing City
下载PDF
Particle properties in granular activated carbon filter during drinking water treatment 被引量:9
5
作者 Tao Lin Wei Chen Leilei Wang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第5期681-688,共8页
The elemental composition and bacteria attached in particles were investigated during granular activated carbon (GAC) filtration.The experimental results showed that trapped influent particles could form new,larger ... The elemental composition and bacteria attached in particles were investigated during granular activated carbon (GAC) filtration.The experimental results showed that trapped influent particles could form new,larger particles on GAC surface.The sloughing of individuals off GAC surface caused an increase in effluent particles in the size range from 5 to 25 μm.The selectivity for element removal in GAC filters caused an increasing proportion of metallic elements in the effluent particles.The distribution of molar ratio indicated a complicated composition for large particles,involving organic and inorganic substances.The organic proportion accounted for 40% of total carbon attached to the particles.Compared with dissolved carbon,there was potential for the formation of trihalomethanes by organic carbon attached to particles,especially for those with size larger than 10 μm.The pure carbon energy spectrum was found only in the GAC effluent and the size distribution of carbon fines was mainly above 10 μm.The larger carbon fines provided more space for bacterial colonization and stronger protection for attached bacteria against disinfection.The residual attached bacteria after chorine disinfection was increased to 10 2-10 3 CFU/mL within 24 hours at 25°C. 展开更多
关键词 drinking water treatment GAC filters bacterial attachment to carbon
下载PDF
Particle size distribution and property of bacteria attached to carbon fines in drinking water treatment 被引量:5
6
作者 Wang Leilei Chen Wei Lin Tao 《Water Science and Engineering》 EI CAS 2008年第2期102-111,共10页
The quantitative change and size distribution of particles in the effluents from a sand filter and a granular activated carbon (GAC) filter in a drinking water treatment plant were investigated. The average total co... The quantitative change and size distribution of particles in the effluents from a sand filter and a granular activated carbon (GAC) filter in a drinking water treatment plant were investigated. The average total concentration of particles in the sand filter effluent during a filter cycle was 148 particles/mL, 27 of which were larger than 2 μm in size. The concentration in the GAC effluent (561 particles/mL) was significantly greater than that in the sand filter effluent. The concentration of particles larger than 2 μm in the GAC filter effluent reached 201 particles/mL, with the amount of particles with sizes between 2 μm and 15 μm increasing. The most probable number (MPN) of carbon fines reached 43 unit/L after six hours and fines between 0.45 μm and 8.0 μm accounted for more than 50%. The total concentration of outflowing bacteria in the GAC filter effluent, 350 CFU (colony-forming units) /mL, was greater than that in the sand filter effluent, 210 CFU/mL. The desorbed bacteria concentration reached an average of 310 CFU/mg fines. The disinfection efficiency of desorbed bacteria was lower than 40% with 1.5 mg/L of chlorine. The disinfection effect showed that the inactivation rate with 2.0 mg/L of chloramine (90%) was higher than that with chlorine (70%). Experimental results indicated that the high particle concentration in raw water and sedimentation effluent led to high levels of outflowing particles in the sand filter effluent. The activated carbon fines in the effluent accounted for a small proportion of the total particle amount, but the existing bacteria attached to carbon fines may influence the drinking water safety. The disinfection efficiency of desorbed bacteria was lower than that of free bacteria with chlorine, and the disinfection effect on bacteria attached to carbon fines with chloramine was better than that with only chlorine. 展开更多
关键词 drinking water treatment particles size distribution bacteria attached to carbon fines INACTIVATION
下载PDF
Pilot Study on Nanofiltration Combined with Ozonation and GAC for Advanced Drinking Water Treatment 被引量:4
7
作者 薛罡 何圣兵 王欣泽 《Journal of Donghua University(English Edition)》 EI CAS 2004年第6期104-108,共5页
A pilot-scale study of advanced drinking water treatment was carried out in test site, and a combination of ozonation, granular activated carbon (GAC) and nanofiltration was employed as the experimental process. By op... A pilot-scale study of advanced drinking water treatment was carried out in test site, and a combination of ozonation, granular activated carbon (GAC) and nanofiltration was employed as the experimental process. By optimizing the operational parameters of ozonation and GAC, a large quantity of micro-pollutants in drinking water was removed, which made the post-positioned nanofiltration operate more reliably. It was evident that nanofiltration shows good performance for removing residual organic matter, meantime partial minerals can also be retained by nanofiltration. Therefore the quality of drinking water can be further improved. In addition, NF membrane fouling and scaling can be solved by concentrate recycling, anti-scalant dosing and chemical rinsing effectively. By GAC adsorption for the residue chlorine and ozone self-decomposition, their oxidation on NF membrane material can be eliminated completely. 展开更多
关键词 drinking water ADVANCED treatment ozonation GAC adsorption NANOFILTRATION
下载PDF
Combination of chlorine and magnetic ion exchange resin for drinking water treatment of algae 被引量:2
8
作者 韩志刚 陈卫 +1 位作者 李磊 曹喆 《Journal of Central South University》 SCIE EI CAS 2010年第5期979-984,共6页
The effectiveness of a magnetic ion exchange resin (MIEX) for the treatment of Hongze Lake water in China was evaluated, The kinetics of natural organic matter (NOM) removal at various MIEX doses and contact time,... The effectiveness of a magnetic ion exchange resin (MIEX) for the treatment of Hongze Lake water in China was evaluated, The kinetics of natural organic matter (NOM) removal at various MIEX doses and contact time, multiple-loading experiments, impacts of MIEX prior to coagulation on coagulant demands and the effectiveness of combination of MIEX, pre-chlorination and coagulation were investigated. Kinetic experimental results show that more than 80% UV254 and 67% dissolved organic carbon (DOC) from raw water can be removed by the use of MIEX alone. 94% sulfate, 69% nitrate and 98% bromide removals are obtained after the first use of MIEX in multiple-loading experiments. It is suggested that MIEX can be loaded up to 1 250 bed volume (BV, volume ratio of tested water to resin) or more without saturation when regarding organics removal as a target. MIEX can remove organics to a greater extend than coagulation and lower the coagulant demand when combining with coagulation. Chlorination experimental results show that MIEX can remove 57% chlorine demand and 77% trihalomethane formation potential (THMFP) for raw water. Pre-chlorination followed by MIEX and coagulation can give additional organic and THMFP removals. The results suggest that MIEX provides a new method to solve thc problem algae reproduction. 展开更多
关键词 drinking water treatment magnetic ion exchange resin natural organic matter pre-chlorination disinfection byproducts ALGAE
下载PDF
Phosphorus limitation in biofiltration for drinking water treatment 被引量:1
9
作者 YUXin ZHANGXiao-jian +2 位作者 LIUXiao-ling ZHAOXiao-dong WANGZhan-sheng 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2003年第4期494-499,共6页
Bacterial growth potential(BGP) method and two parallel pilot scale biofilters were used to investigate phosphorus limitation and its effect on the removal of organic matters in biofiltration for drinking water treat... Bacterial growth potential(BGP) method and two parallel pilot scale biofilters were used to investigate phosphorus limitation and its effect on the removal of organic matters in biofiltration for drinking water treatment. Addition of phosphorus can substantially increase the BGPs of the samples. Its effect was equivalent to that of addition of a mixture of various inorganic nutrients including phosphorus. The biofilter with phosphate added into its influent performed a higher biological stability of the effluent and a higher COD Mn removal than the control filter. These results suggested that phosphorus was the limiting nutrient in the biofiltration and the removal efficiency of organic matters could be improved by adding phosphate into the influent. 展开更多
关键词 drinking water biological treatment BIOFILTER limiting nutrient phosphorus carbon
下载PDF
Immobilization biological activated carbon used in advanced drinking water treatment 被引量:2
10
作者 马放 杨海燕 王弘宇 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2006年第6期678-682,共5页
Bacteria separated from a mature filter bed of groundwater treatment plants were incubated in a culture media containing iron and manganese. A consortium of 5 strains of bacteria removing iron and manganese were obtai... Bacteria separated from a mature filter bed of groundwater treatment plants were incubated in a culture media containing iron and manganese. A consortium of 5 strains of bacteria removing iron and manganese were obtained by repeated enrichment culturing. It was shown from the experiments of effect factors that ironmanganese removal bacteria in the euhure media containing both Fe and Mn grew better than in that containing only Fe, however, they were unable to grow in the culture media containing only Mn. When comparing the bacteria biomass in the case ofp (DO) :2.8 mg/L andp (DO) :9. 0 mg/L, no significant difference was found. The engineering bacteria removing the organic and the bacteria removing iron and manganese were simuhaneously inoculated into activated carbon reactor to treat the effluent of distribution network. The experimental results showed that by using IBAC ( Immobilization Biological Activated Carbon) treatment, the removal efficiency of iron, manganese and permanganate index was more than 98% , 96% and 55% , respectively. After the influent with turbidity of 1.5 NTU, color of 25 degree and oflbnsive odor was treated, the turbidity and color of effluence were less than 0.5 NTU and 15 degree, respectively, and it was odorless. It is determined that the cooperation function of engineering bacteria and activated carbon achieved advanced drinking water treatment. 展开更多
关键词 advanced drinking water treatment miero-pollutaats IBAC: iron and manganese removal engi- neering bacteria
下载PDF
Effect of typhoon with extreme precipitation on mountain reservoir drinking water treatment: a case study in Ningbo, China 被引量:8
11
作者 Wei Chen Zhengxie Zhou +2 位作者 Jianrong He Hui Tao Zhigang Liu 《Chinese Journal of Population,Resources and Environment》 2017年第2期103-108,共6页
Due to frequent drinking water pollution accidents in the past decade, it is common that mountain reservoirs were used as the source of drinking water in China. However, some coastal areas frequently suffer from typho... Due to frequent drinking water pollution accidents in the past decade, it is common that mountain reservoirs were used as the source of drinking water in China. However, some coastal areas frequently suffer from typhoon with extreme precipitation, which results in the water quality deterioration of the reservoirs. The influence of typhoons with extreme precipitation on Jiaokou reservoir and the emergency treatment process of Maojiaping water treatment plant in the past three typical typhoons with extreme precipitation from the year of 2012-2015 were studied. It was found that the degradation of water quality, such as the increase of turbidity and bacteria index, may not merely appear during the events, but last for several days. Changing the dosage of water purification agent, such as coagulant and disinfectant at right time and place may be an efficient emergency water treatment process. Based on the analysis of water quality variation rule during and after the events, it was also found that emergency treatment can be fully prepared before the arrival of a typhoon with extreme precipitation. And in order to better respond to the typhoon with extreme precipitation, several suggestions are also proposed in this paper as follows: establishing vegetated buffers at right place, such as macrophanerophytes,shrub or herbage, increasing investments in infrastructure management, merging or cancelling the small-scale water treatment plants, preparing adequate water purification agent before the typhoon comes, etc. 展开更多
关键词 Typhoon with extreme precipitation mountain reservoir emergency drinking water treatment microorganisms
下载PDF
Sonication for advanced drinking water treatment 被引量:1
12
作者 张光明 魏希柱 +2 位作者 李相昆 张杰 豆子波 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2009年第1期16-20,共5页
This paper investigated the feasibility of sonication as an advanced treatment method for drinking water production and used comprehensive indexes of water quality to examine its efficiency. Results show that sonicati... This paper investigated the feasibility of sonication as an advanced treatment method for drinking water production and used comprehensive indexes of water quality to examine its efficiency. Results show that sonication significantly reduces the toxicity of water. Sonication with 5 W/L at 90 kHz lasting for 30 rain decreases the water SUVA and the disinfection byproduct formation potential (DBPFP) by 38.7% and 27. 2% respectively. Sonication also decreases the UV254 by more than 50% through destroying unsaturated chemical bonds. Higher sound intensity and higher frequency benefit the reduction of TOC and UV254. Besides, sonication significantly increases the affinity of organics with granular activated carbon ( GAC ) , and thus the hybrid sonication-GAC method reduces the water TOC, COD, UV254, and DBPFP by 78.3%, 69.4%, 75.7%, and 70.0% respectively. Therefore, sonication and the hybrid sonication-GAC metbod are proposed as advanced treatment methods for drinking water. 展开更多
关键词 sonieation drinking water advanced treatment DBPFP
下载PDF
Pilot Study on Drinking Water Advanced Treatment by GAC-MF System 被引量:1
13
作者 王欣泽 薛罡 +1 位作者 王宝贞 王琳 《Journal of Donghua University(English Edition)》 EI CAS 2004年第1期135-139,共5页
The pilot performance of the combined GAC-MF membrane process for drinking water advanced treatment was described. In the process of GAC adsorption, under the conditions of 20 min HRT and 6 m/h filtration rate, the re... The pilot performance of the combined GAC-MF membrane process for drinking water advanced treatment was described. In the process of GAC adsorption, under the conditions of 20 min HRT and 6 m/h filtration rate, the removal efficiencies of UV_(254) and trichloromethane could reach 40% and 50% respectively and the UV_(254) and trichloromethane in system effluent was less than 0.015 cm^(-1) and 5μg/L respectively. In the post MF membrane process, MF membrane effectively retained the particles and bacteria in raw water. The effluent turbidity was less than 0.2 NTU and no bacteria were detected at all in permeate. A computer-controlled system was employed to control this system. The membrane operating parameters of backwash interval, duration and flux were studied. The backwash interval of 10-min, 20-min and 60-min was researched respectively, and the variation of trans-membrane pressure was also analyzed. Consequently short backwash interval was recommended under the same water consume. 展开更多
关键词 granular activated carbon adsorption MF membrane drinking water advanced treatment
下载PDF
Problems of drinking water treatment along Ismailia Canal Province, Egypt
14
作者 Mohamed H.GERIESH Klaus-Dieter BALKE Ahmed E.EL-RAYES 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2008年第3期232-242,共11页
The present drinking water purification system in Egypt uses surface water as a raw water supply without a preliminary filtration process.On the other hand,chlorine gas is added as a disinfectant agent in two steps,pr... The present drinking water purification system in Egypt uses surface water as a raw water supply without a preliminary filtration process.On the other hand,chlorine gas is added as a disinfectant agent in two steps,pre-and post-chlorination.Due to these reasons most of water treatment plants suffer low filtering effectiveness and produce the trihalomethane(THM) species as a chlorination by-product.The Ismailia Canal represents the most distal downstream of the main Nile River.Thus its water contains all the proceeded pollutants discharged into the Nile.In addition,the downstream reaches of the canal act as an agricultural drain during the closing period of the High Dam gates in January and February every year.Moreover,the wide industrial zone along the upstream course of the canal enriches the canal water with high concentrations of heavy metals.The obtained results indicate that the canal gains up to 24.06×106 m3 of water from the surrounding shallow aquifer during the closing period of the High Dam gates,while during the rest of the year,the canal acts as an influent stream losing about 99.6×106 m3 of its water budget.The reduction of total organic carbon(TOC) and suspended particulate matters(SPMs) should be one of the central goals of any treatment plan to avoid the disinfectants by-products.The combination of sedimentation basins,gravel pre-filtration and slow sand filtration,and underground passage with microbiological oxidation-reduction and adsorption criteria showed good removal of parasites and bacteria and complete elimination of TOC,SPM and heavy metals.Moreover,it reduces the use of disinfectants chemicals and lowers the treatment costs.However,this purification system under the arid climate prevailing in Egypt should be tested and modified prior to application. 展开更多
关键词 drinking water treatment Hazardous by-products Natural attenuation Ismailia Canal EGYPT
下载PDF
Novel FGBAC reactor for controlling the leakage of microfauna in drinking water treatment
15
作者 丁国际 施嘉明 +2 位作者 周文琪 张东 蔡云龙 《Journal of Shanghai University(English Edition)》 CAS 2010年第4期246-250,共5页
In order to reduce the microfauna leakage risk from a granular biological activated carbon (GBAC) reactor which employs granular activated carbon (GAC) as adsorption media in drinking water advanced treatment, a n... In order to reduce the microfauna leakage risk from a granular biological activated carbon (GBAC) reactor which employs granular activated carbon (GAC) as adsorption media in drinking water advanced treatment, a novel fiber and granular biological activated carbon (FGBAC) reactor which employs both GAC and activated carbon fiber (ACF) as adsorption media, was developed. The results showed that the species composition of microfauna leaking from FGBAC reactor is almost similar to that leaking from GBAC reactor, however the densities of microfauna leaking from FGBAC reactor is reduced by 26%-81% compared to those leaking from GBAC reactor. In addition, compared to GBAC reactor, FGBAC reactor can increase the removal efflciencies of chemical oxygen demand (COD) and turbidity by 7% and 10%, respectively, during the stable operation period of reactor. 展开更多
关键词 advanced drinking water treatment biological activated carbon granular activated carbon (GAC) activatedcarbon fiber (ACF) MICROFAUNA
下载PDF
Efficiency characterization of ceramic filtering materials used for drinking water treatment
16
作者 冯奇 邱珊 +1 位作者 马放 陶鑫 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2007年第5期619-622,共4页
For ceramic filtering materials, their adsorption capacities, purification efficiencies to remove organic compounds from drinking water, and correlation between adsorption capacities and pore structures were tested an... For ceramic filtering materials, their adsorption capacities, purification efficiencies to remove organic compounds from drinking water, and correlation between adsorption capacities and pore structures were tested and analyzed. The results show that correlation coefficient between the specific surface area and the adsorptive amount of iodine molecule is 0.99; correlation coefficient between the pore volume and the adsorptive value of tannin molecule is 0.92, and correlation coefficient between the most probable diameter and the adsorption parameter is 1.0. A new method of morphology characterization for ceramic filtering materials was developed, which offered a sort of standard for the evaluation on water purification efficiencies and selection of ceramic filtering materials. 展开更多
关键词 ceramic filtering materials pore structure adsorption capability filtering efficiency drinking water treatment
下载PDF
Performance of a Horizontal Flow Constructed Reed Bed Filter for Municipal Wastewater Treatment: The Case Study of the Prototype Installed at Gaston Berger University, Saint-Louis, Senegal
17
作者 Abdou Khafor Ndiaye Falilou Coundoul +2 位作者 Abdoulaye Deme Antonina Torrens Armengol Abdoulaye Senghor 《Natural Resources》 2024年第1期1-16,共16页
In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed... In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed only a slight temperature variation, from an influent average of 26.3°C to an effluent of 24.7°C. Electrical conductivity decreased from 1331 mS/cm to 974.5 mS/cm post-primary treatment, with suspended solids (SS) dramatically reduced from 718.9 mg/L to 5.7 mg/L in the final effluent. Biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) saw a notable decrease, from initial levels of 655.6 mg/L and 1240 mg/L to 2.3 mg/L and 71.3 mg/L, respectively. Nitrogenous compounds (N-TN) and phosphates () also decreased significantly, indicating the system’s nutrient removal capacity. Microbiological analysis revealed a reduction in fecal coliforms from 7.5 Ulog/100ml to 1.8 Ulog/100ml and a complete elimination of helminth eggs. The presence of Phragmites and Typha was instrumental in enhancing these reductions. The system’s compliance with the Senegalese standards for disposal into natural environments, WHO recommendations for unrestricted water reuse in irrigation, and the European legislation for water reuse was established. The effluent quality met the stringent criteria for various classes of agricultural reuse, illustrating the system’s potential for sustainable water management. This wetland model presents a robust solution for water-stressed regions, ensuring environmental protection while supporting agricultural needs. The study calls for ongoing research to further refine the system for optimal, reliable wastewater treatment and water resource sustainability. 展开更多
关键词 Constructed Wetlands Horizontal Flow Reed Beds Wastewater treatment Phragmites and Typha Plants Physicochemical pollutant Removal Microbiological Indicators Fecal Coliforms and Helminth Eggs water Quality Improvement Senegal water Reuse Standards Sustainable water Management Agricultural Irrigation Reuse Nutrient Removal Efficiency Environmental Engineering Ecological Sanitation Systems
下载PDF
Drinking water production by uitrafiltration of Songhuajiang River with PAC adsorption 被引量:31
18
作者 XIA Sheng-ji LIU Ya-nane +1 位作者 LI Xing YAO Juan-juan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第5期536-539,共4页
In recent years, membrane ultrafiltration (UF) of surface water for drinking water treatment has become a more attractive technology worldwide as a possible alternative treatment to conventional clarification. To ev... In recent years, membrane ultrafiltration (UF) of surface water for drinking water treatment has become a more attractive technology worldwide as a possible alternative treatment to conventional clarification. To evaluate the performance of ultrafiltration membranes for treatment of surface water in North China, a 48-m^2 low pressure hollow fiber membrane ultrafiltration pilot plant was constructed. Ultrafiltration was operated in cross-flow and with powdered activated carbon (PAC) adsorption. Turbidity was almost completely removed to less than 0.2 NTU (below Chinese standard 1 NTU). It was found that PAC addition enhanced organic matter removal. The combined process of PAC/UF allowed to 41% removal of CODMn, 46% removal of DOC and 57% decrease in UV254 absorbance. The elimination of particles, from average 12000/ml in the raw water to approximately 15/ml in the permeated, was observed. When PAC concentration was below 30 mg/L, backwashing could recovery the membrane flux with backwash interval/backwashing duration of 1/30. 展开更多
关键词 surface water drinking water treatment ULTRAFILTRATION powdered activated carbon
下载PDF
Arsenic Distribution Pattern in Different Sources of Drinking Water and their Geological Background in Guanzhong Basin, Shaanxi, China 被引量:2
19
作者 LUO Kunli ZHANG Shixi +1 位作者 TIAN Yuan GAO Xing 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2014年第3期984-994,共11页
To study arsenic (As) content and distribution patterns as well as the genesis of different kinds of water,especially the different sources of drinking water in Guanzhong Basin,Shaanxi province,China,139 water sampl... To study arsenic (As) content and distribution patterns as well as the genesis of different kinds of water,especially the different sources of drinking water in Guanzhong Basin,Shaanxi province,China,139 water samples were collected at 62 sampling points from wells of different depths,from hot springs,and rivers.The As content of these samples was measured by the intermittent flowhydride generation atomic fluorescence spectrometry method (HG-AFS).The As concentrations in the drinking water in Guanzhong Basin vary greatly (0.00-68.08 tg/L),and the As concentration of groundwater in southern Guanzhong Basin is different from that in the northern Guanzhong Basin.Even within the same location in southern Guanzhong Basin,the As concentrations at different depths vary greatly.As concentration of groundwater from the shallow wells (〈50 m deep,0.56-3.87 μg/L) is much lower than from deep wells (110-360 m deep,19.34-62.91 μg/L),whereas As concentration in water of any depth in northern Guanzhong Basin is 〈10 μg/L.Southern Guanzhong Basin is a newly discovered high-As groundwater area in China.The high-As groundwater is mainly distributed in areas between the Qinling Mountains and Weihe River; it has only been found at depths ranging from 110 to 360 m in confined aquifers,which store water in the Lishi and Wucheng Loess (Lower and Middle Pleistocene) in the southern Guanzhong Basin.As concentration of hot spring water is 6.47-11.94 μg/L; that of geothermal water between 1000 and 1500 m deep is 43.68-68.08 μg/L.The high-As well water at depths from 110 to 360 m in southern Guanzhong Basin has a very low fluorine (F) value,which is generally 〈0.10 mg/L.Otherwise,the hot springs of Lintong and Tangyu and the geothermal water in southern Guanzhong Basin have very high F values (8.07-14.96 mg/L).The results indicate that high As groundwater in depths from 110 to 360 m is unlikely to have a direct relationship with the geothermal water in the same area.As concentration of all reservoirs and rivers (both contaminated and uncontaminated) in the Guanzhong Basin is 〈10 μg/L.This shows that pollution in the surface water is not the source of the high-As in the southern Guanzhong Basin.The partition boundaries of the high-and low-As groundwater area corresponds to the partition boundaries of the tectonic units in the Guanzhong Basin.This probably indicates that the high-As groundwater areas can be correlated to their geological underpinning and structural framework.In southern Guanzhong Basin,the main sources of drinking water for villages and small towns today are wells between 110-360 m deep.All of their As contents exceed the limit of the Chinese National Standard and the International Standard (〉10 μg/L) and so local residents should use other sources of clean water that are 〈50 m deep,instead of deep groundwater (110 to 360 m) for their drinking water supply. 展开更多
关键词 HYDROLOGY pollution water chemistry drinking water quality different groundwaterdepths arsenic content Pleistocene Loess Guanzhong Basin
下载PDF
A review of physicochemical and biological contaminants in drinking water and their impacts on human health 被引量:1
20
作者 Ahsan Shah Arun Arjunan +1 位作者 Ahmad Baroutaji Julia Zakharova 《Water Science and Engineering》 EI CAS CSCD 2023年第4期333-344,共12页
Clean drinking water is one of the United Nations Sustainable Development Goals.Despite significant progress in the water purification technology,many regions still lack access to clean water.This paper provides a rev... Clean drinking water is one of the United Nations Sustainable Development Goals.Despite significant progress in the water purification technology,many regions still lack access to clean water.This paper provides a review of selected water contaminants and their impacts on human health.The World Health Organization(WHO)guidelines and regional standards for key contaminants were used to characterise water quality in the European Union and UK.The concept of safe drinking water was explained based on the non-observed adverse effect level,threshold concentrations for toxic chemicals,and their total daily intake.Various techniques for monitoring water contaminants and the drinking water standards from five different countries,including the UK,USA,Canada,Pakistan and India,were compared to WHO recommended guidelines.The literature on actual water quality in these regions and its potential health impacts was also discussed.Finally,the role of public water suppliers in identifying and monitoring drinking water contaminants in selected developed countries was presented as a potential guideline for developing countries.This review emphasised the need for a comprehensive understanding of water quality and its impacts on human health to ensure access to clean drinking water worldwide. 展开更多
关键词 drinking water contaminants Physicochemical contaminants Biological contaminants Human health risks waterborne diseases water quality Public health concerns water treatment
下载PDF
上一页 1 2 146 下一页 到第
使用帮助 返回顶部