Drift phenomenon has been known as the drawback of sensors and causes inaccuracy on the long-term measurement. In general,there are two methods to reduce the drift problem.One is to tune the parameters of the fabricat...Drift phenomenon has been known as the drawback of sensors and causes inaccuracy on the long-term measurement. In general,there are two methods to reduce the drift problem.One is to tune the parameters of the fabrication process to improve the properties of the front-ended device.Another is to compensate the drift phenomenon by adding extra drift compensation circuit or software in the back-ended readout circuit.In this study,a drift calibration method for the potentiometric sensor was presented and the drift calibration method was performed by using the circuit.According to experimental results,the drift phenomenon of the SnO_2 pH electrode was reduced by the drift calibration device.展开更多
A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which...A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which can generate the output with a rise time of less than 2 ns and a duration of larger than 300 ns. The step current generator is composed by a pulse forming line (PFL) and a pulse transmission line (PTL). A TEM (transverse electromagnetic mode) coaxial measurement unit is used as PTL, and the coil to be calibrated and the referenced standard Rogowski coil can be fixed in the unit. The effect of the dimensions of the TEM unit is discussed theoretically as well as experimentally.展开更多
The 252 Cf neutron brachytherapy devices were designed and manufactured after solving those problems: the shield difficulties for 252Cf neutron; the method and facilities for 252Cf neutron source deliver; the dose ca...The 252 Cf neutron brachytherapy devices were designed and manufactured after solving those problems: the shield difficulties for 252Cf neutron; the method and facilities for 252Cf neutron source deliver; the dose calculation and measurement for 252Cf neutron. From 1999 to 2009, more than twenty 252Cf neutron brachytherapy devices had been installed in China. The Chinese radiation oncologists implemented the 252 Cf neutron braehytherapy on more than 5 000 different kinds of cancer patients, including cervix cancer; endometrium cancer and achieved ideal results. For special presentation, they had breakthrough on radical treatment for low lying rectal adenocarcinoma with sphincter preservation and melanoma patients after the modification of 252Cf neutron intracavitary applicator and dose calibration.展开更多
The current study is based on the DEM computer simulation of three experimental test devices with different dimensions to determine the difference in the results of the formation of shear and repose angles that the pa...The current study is based on the DEM computer simulation of three experimental test devices with different dimensions to determine the difference in the results of the formation of shear and repose angles that the particles experience when grouped under the action of the gravitational force. In this respect, the experimental test devices with different height, width, and depth were geometrically modeled with iron pellet particles using morphology and a granulometric variation from 6 mm to 9 mm of equivalent diameter in its spherical shape. Depending on the results obtained, a reliable size of the experimental test device will be available to obtain the necessary data for a correct adjustment of the calibration parameters for the DEM simulation of mining-metallurgical processes that use granulated material of iron pellet.展开更多
A novel in-contact three-dimensional(3D)measuring device,called MultiCal,is proposed as a convenient,low-cost(less than US$5000),and robust facility for onsite kinematic calibration and online measurement of robot man...A novel in-contact three-dimensional(3D)measuring device,called MultiCal,is proposed as a convenient,low-cost(less than US$5000),and robust facility for onsite kinematic calibration and online measurement of robot manipulator accuracy.The device hasμm-level accuracy and can be easily embedded in robot cells.During the calibration procedure,the robot manipulator first moves automatically to multiple end-effector orientations with its tool center point(TCP)constrained on a fixed point by a 3D displacement measuring device(single point constraint),and the corresponding joint angles are recorded.Then,the measuring device is precisely mounted at different positions using a well-designed fixture,and the above measurement process is repeated to implement a multi-point constraint.The relative mounting positions are accurately measured and used as prior information to improve calibration accuracy and robustness.The results of theoretical analysis indicate that MultiCal reduces calibration accuracy by 10%to 20%in contrast to traditional non-contact 3D or six-dimensional(6D)measuring devices(such as laser trackers)when subject to the same level of artificial measurement noise.The results of a calibration experiment conducted on a Staubli TX90 robot show that MultiCal has only 7%to 14%lower calibration accuracy compared to a measuring arm with a laser scanner,and 21%to 30%lower time efficiency compared to a 6D binocular vision measuring system,yielding maximum and mean absolute position errors of 0.831 mm and 0.339 mm,respectively.展开更多
The site of Shanghai Synchrotron Radiation Facility (SSRF) is of complicated geological conditions, and a system to monitor the uneven subsidence of foundation and key parts (different kinds of magnets) of the acceler...The site of Shanghai Synchrotron Radiation Facility (SSRF) is of complicated geological conditions, and a system to monitor the uneven subsidence of foundation and key parts (different kinds of magnets) of the accelerators is a necessity. Considering actual conditions of the accelerator structure and the assembling place, a new type of sensor of hydrostatic levelling system (HLS) has been designed. In order to obtain the required measurement accuracy, every HLS’s sensor was strictly calibrated. In this paper, we introduce the special calibration method to establish the HLS. The method has been used in the calibration for vessel sensor for SSRF.展开更多
The rolling production of metal thin strips,especially the production of stainless steel and copper thin strips with high yield strength,due to the limitation of the minimum rolling thickness,multi roll mills with sma...The rolling production of metal thin strips,especially the production of stainless steel and copper thin strips with high yield strength,due to the limitation of the minimum rolling thickness,multi roll mills with small working roll diameter are mostly used,and the 20 roll mill is the most common.Aiming at the problem that the actual tension of some 20 high rolling mills with long service time and low assembly accuracy has a large deviation from the set tension and is not accurate enough,this paper first designs the tension calibration device of the low precision 20 high rolling mill.Secondly,the calibration principle of the tension calibration device designed in this paper is described.Then,according to the calibration principle and specific implementation scheme,the actual tension tact of the strip steel is comprehensively determined,and the mapping relationship between the set tension tset and the actual tension tact of the 20 high mill is established,so as to improve the tension control accuracy of the 20 high mill and ensure the shape quality of the strip steel.展开更多
文摘Drift phenomenon has been known as the drawback of sensors and causes inaccuracy on the long-term measurement. In general,there are two methods to reduce the drift problem.One is to tune the parameters of the fabrication process to improve the properties of the front-ended device.Another is to compensate the drift phenomenon by adding extra drift compensation circuit or software in the back-ended readout circuit.In this study,a drift calibration method for the potentiometric sensor was presented and the drift calibration method was performed by using the circuit.According to experimental results,the drift phenomenon of the SnO_2 pH electrode was reduced by the drift calibration device.
文摘A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which can generate the output with a rise time of less than 2 ns and a duration of larger than 300 ns. The step current generator is composed by a pulse forming line (PFL) and a pulse transmission line (PTL). A TEM (transverse electromagnetic mode) coaxial measurement unit is used as PTL, and the coil to be calibrated and the referenced standard Rogowski coil can be fixed in the unit. The effect of the dimensions of the TEM unit is discussed theoretically as well as experimentally.
文摘The 252 Cf neutron brachytherapy devices were designed and manufactured after solving those problems: the shield difficulties for 252Cf neutron; the method and facilities for 252Cf neutron source deliver; the dose calculation and measurement for 252Cf neutron. From 1999 to 2009, more than twenty 252Cf neutron brachytherapy devices had been installed in China. The Chinese radiation oncologists implemented the 252 Cf neutron braehytherapy on more than 5 000 different kinds of cancer patients, including cervix cancer; endometrium cancer and achieved ideal results. For special presentation, they had breakthrough on radical treatment for low lying rectal adenocarcinoma with sphincter preservation and melanoma patients after the modification of 252Cf neutron intracavitary applicator and dose calibration.
文摘The current study is based on the DEM computer simulation of three experimental test devices with different dimensions to determine the difference in the results of the formation of shear and repose angles that the particles experience when grouped under the action of the gravitational force. In this respect, the experimental test devices with different height, width, and depth were geometrically modeled with iron pellet particles using morphology and a granulometric variation from 6 mm to 9 mm of equivalent diameter in its spherical shape. Depending on the results obtained, a reliable size of the experimental test device will be available to obtain the necessary data for a correct adjustment of the calibration parameters for the DEM simulation of mining-metallurgical processes that use granulated material of iron pellet.
基金Project supported by the Key R&D Program of Zhejiang Province,China(No.2022C04030)the National Key R&D Program of China(Nos.2020YFB1313300 and 2018AAA0102703)the National Natural Science Foundation of China(No.61836015)。
文摘A novel in-contact three-dimensional(3D)measuring device,called MultiCal,is proposed as a convenient,low-cost(less than US$5000),and robust facility for onsite kinematic calibration and online measurement of robot manipulator accuracy.The device hasμm-level accuracy and can be easily embedded in robot cells.During the calibration procedure,the robot manipulator first moves automatically to multiple end-effector orientations with its tool center point(TCP)constrained on a fixed point by a 3D displacement measuring device(single point constraint),and the corresponding joint angles are recorded.Then,the measuring device is precisely mounted at different positions using a well-designed fixture,and the above measurement process is repeated to implement a multi-point constraint.The relative mounting positions are accurately measured and used as prior information to improve calibration accuracy and robustness.The results of theoretical analysis indicate that MultiCal reduces calibration accuracy by 10%to 20%in contrast to traditional non-contact 3D or six-dimensional(6D)measuring devices(such as laser trackers)when subject to the same level of artificial measurement noise.The results of a calibration experiment conducted on a Staubli TX90 robot show that MultiCal has only 7%to 14%lower calibration accuracy compared to a measuring arm with a laser scanner,and 21%to 30%lower time efficiency compared to a 6D binocular vision measuring system,yielding maximum and mean absolute position errors of 0.831 mm and 0.339 mm,respectively.
文摘The site of Shanghai Synchrotron Radiation Facility (SSRF) is of complicated geological conditions, and a system to monitor the uneven subsidence of foundation and key parts (different kinds of magnets) of the accelerators is a necessity. Considering actual conditions of the accelerator structure and the assembling place, a new type of sensor of hydrostatic levelling system (HLS) has been designed. In order to obtain the required measurement accuracy, every HLS’s sensor was strictly calibrated. In this paper, we introduce the special calibration method to establish the HLS. The method has been used in the calibration for vessel sensor for SSRF.
文摘The rolling production of metal thin strips,especially the production of stainless steel and copper thin strips with high yield strength,due to the limitation of the minimum rolling thickness,multi roll mills with small working roll diameter are mostly used,and the 20 roll mill is the most common.Aiming at the problem that the actual tension of some 20 high rolling mills with long service time and low assembly accuracy has a large deviation from the set tension and is not accurate enough,this paper first designs the tension calibration device of the low precision 20 high rolling mill.Secondly,the calibration principle of the tension calibration device designed in this paper is described.Then,according to the calibration principle and specific implementation scheme,the actual tension tact of the strip steel is comprehensively determined,and the mapping relationship between the set tension tset and the actual tension tact of the 20 high mill is established,so as to improve the tension control accuracy of the 20 high mill and ensure the shape quality of the strip steel.