基于双混频时差技术设计研制了8通道的频率稳定度测量系统,实现了对8路5 MHz或10 MHz频率标准的测量.当频率为10 MHz取样时间为1 s时,系统噪声本底优于2.0 X 10^(-13),取样时间为1000 s时,系统噪声本底优于2.5×10^(-16).不但可以...基于双混频时差技术设计研制了8通道的频率稳定度测量系统,实现了对8路5 MHz或10 MHz频率标准的测量.当频率为10 MHz取样时间为1 s时,系统噪声本底优于2.0 X 10^(-13),取样时间为1000 s时,系统噪声本底优于2.5×10^(-16).不但可以满足原子时标基准原子钟组的内部比对,也可实现对一般频率标准的检定和校准.
Abstract:
Based on the technique of Dual Mixer Time Difference (DMTD), an 8-channel frequency stabilitymeasurement system has been developed. It realized the measurement of 8-channel 5 MHz and 10 MHz frequencystandards. For 10 MHz frequency, the noise floor is better than 2.0 ×10^(-13)/1 s, 2.5× 10^(-16)/1000 s. It can not only satisfy the internal comparison of time scale ensemble, but also can realize the calibration of normal frequency standards.展开更多
Due to the large scale of Water Cherenkov Detector Array in Large High Altitude Air Shower Observatory, the frontend digitization is imperative.Thus a clock distribution system is desired,which broadcasts the synchron...Due to the large scale of Water Cherenkov Detector Array in Large High Altitude Air Shower Observatory, the frontend digitization is imperative.Thus a clock distribution system is desired,which broadcasts the synchronous clock signals with low jitter to the frontend electronics distributed in the field of 90 000 m^2.The White Rabbit protocol provides an option,which has been approved to achieve sub-ns accuracy and ps jitter in the synchronization of around 1 000 nodes in the order of 10 km.But the hierarchy of the original is too complex for Large High Altitude Air Shower Observatory application.Thus we proposed a reduced scheme based on the White Rabbit protocol.The validation circuit shows that the clock skew due to the fiber length difference can be adjusted to less than 25 ps and the clock jitter is less than 62 ps.展开更多
文摘基于双混频时差技术设计研制了8通道的频率稳定度测量系统,实现了对8路5 MHz或10 MHz频率标准的测量.当频率为10 MHz取样时间为1 s时,系统噪声本底优于2.0 X 10^(-13),取样时间为1000 s时,系统噪声本底优于2.5×10^(-16).不但可以满足原子时标基准原子钟组的内部比对,也可实现对一般频率标准的检定和校准.
Abstract:
Based on the technique of Dual Mixer Time Difference (DMTD), an 8-channel frequency stabilitymeasurement system has been developed. It realized the measurement of 8-channel 5 MHz and 10 MHz frequencystandards. For 10 MHz frequency, the noise floor is better than 2.0 ×10^(-13)/1 s, 2.5× 10^(-16)/1000 s. It can not only satisfy the internal comparison of time scale ensemble, but also can realize the calibration of normal frequency standards.
基金Supported by the National Natural Science Foundation of China(No.11175174 and No.11005107)the Knowledge Innovation Program of the Chinese Academy of Sciences(KJCX2-YW-N27)
文摘Due to the large scale of Water Cherenkov Detector Array in Large High Altitude Air Shower Observatory, the frontend digitization is imperative.Thus a clock distribution system is desired,which broadcasts the synchronous clock signals with low jitter to the frontend electronics distributed in the field of 90 000 m^2.The White Rabbit protocol provides an option,which has been approved to achieve sub-ns accuracy and ps jitter in the synchronization of around 1 000 nodes in the order of 10 km.But the hierarchy of the original is too complex for Large High Altitude Air Shower Observatory application.Thus we proposed a reduced scheme based on the White Rabbit protocol.The validation circuit shows that the clock skew due to the fiber length difference can be adjusted to less than 25 ps and the clock jitter is less than 62 ps.