On the basis of investigated enhancement effect of La, Nd, Eu, and Y on Sm determination with monoxide molecular emission spectrometry, La was selected as enhancement agent and chemical interference inhibitor. In the ...On the basis of investigated enhancement effect of La, Nd, Eu, and Y on Sm determination with monoxide molecular emission spectrometry, La was selected as enhancement agent and chemical interference inhibitor. In the presence of La, dual wavelength mothod was introduced to eliminate the spectral interference on Sm by other elements. A new method was established to determine samarium in high yttrium rare earth samples with satisfactory results.展开更多
Two simple, accurate, precise and economic spectrophotometric methods have been developed for simultaneous determination of Atorvastatin calcium (ATR) and Ezetimibe (EZ) in their bulk powder and pharmaceutical dosage ...Two simple, accurate, precise and economic spectrophotometric methods have been developed for simultaneous determination of Atorvastatin calcium (ATR) and Ezetimibe (EZ) in their bulk powder and pharmaceutical dosage form. Method (I) is based on dual wavelength analysis while method (II) is the mean centering of ratio spectra spectrophotometric (MCR) method. In method (I), two wavelengths were selected for each drug in such a way that the difference in absorbance was zero for the second drug. At wavelengths 226.6 and 244 nm EZ had equal absorbance values; therefore, these two wavelengths have been used to determine ATR; on a similar basis 228.6 and 262.8 nm were selected to determine EZ in their binary mixtures. In method II, the absorption spectra of both ATR and EZ with different concentrations were recorded over the range 200-350, divided by the spectrum of suitable divisor of both ATR and EZ and then the obtained ratio spectra were mean centered. The concentrations of active components were then determined from the calibration graphs obtained by measuring the amplitudes at 215-260 nm (peak to peak) for both ATR and EZ. Accuracy and precision of the developed methods have been tested; in addition recovery studies have been carried out in order to confirm their accuracy. On the other hand, selectivities of the methods were tested by application for determination of different synthetic mixtures containing different ratios of the studied drugs. The developed methods have been successfully used for determination of ATR and EZ in their combined dosage form and statistical comparison of the developed methods with the reported spectrophotometric one using F and Student’s t-tests showed no significant difference regarding both accuracy and precision.展开更多
This paper presents an in-situ, non-contact, non-destructive "dual-wavelength laser flash Raman spectroscopy method" for measuring the thermal diffusivity. In this method, a heating pulse is used to heat the...This paper presents an in-situ, non-contact, non-destructive "dual-wavelength laser flash Raman spectroscopy method" for measuring the thermal diffusivity. In this method, a heating pulse is used to heat the sample and another pulsed laser with a different wavelength and negligible heating effect is used as a probe to measure the sample temperature changes during the heating and cooling periods from the Raman peak shifts. The sample temperature rise and fall curves are measured by changing the delay between the heating pulse and the probing pulse with the thermal diffusivity then characterized by fitting the temperature curves. The time delay between the heating and probing pulses can be precisely controlled with a minimum step of 100 ps. Hence, the temperature variation can be scanned with an ultra-high temporal resolution of up to 100 ps, which significantly improves the measurement accuracy of transient thermal parameters. The measurement accuracy of this method has been verified using a bulk material model and experiments. The measured thermal diffusivity of a silicon sample has been obtained to be 8.8×10^(-5 )m^2/s with a 3% difference between the measured value and the average result for bulk silicon in the literature which verifies the reliability and accuracy of this method.展开更多
文摘On the basis of investigated enhancement effect of La, Nd, Eu, and Y on Sm determination with monoxide molecular emission spectrometry, La was selected as enhancement agent and chemical interference inhibitor. In the presence of La, dual wavelength mothod was introduced to eliminate the spectral interference on Sm by other elements. A new method was established to determine samarium in high yttrium rare earth samples with satisfactory results.
文摘Two simple, accurate, precise and economic spectrophotometric methods have been developed for simultaneous determination of Atorvastatin calcium (ATR) and Ezetimibe (EZ) in their bulk powder and pharmaceutical dosage form. Method (I) is based on dual wavelength analysis while method (II) is the mean centering of ratio spectra spectrophotometric (MCR) method. In method (I), two wavelengths were selected for each drug in such a way that the difference in absorbance was zero for the second drug. At wavelengths 226.6 and 244 nm EZ had equal absorbance values; therefore, these two wavelengths have been used to determine ATR; on a similar basis 228.6 and 262.8 nm were selected to determine EZ in their binary mixtures. In method II, the absorption spectra of both ATR and EZ with different concentrations were recorded over the range 200-350, divided by the spectrum of suitable divisor of both ATR and EZ and then the obtained ratio spectra were mean centered. The concentrations of active components were then determined from the calibration graphs obtained by measuring the amplitudes at 215-260 nm (peak to peak) for both ATR and EZ. Accuracy and precision of the developed methods have been tested; in addition recovery studies have been carried out in order to confirm their accuracy. On the other hand, selectivities of the methods were tested by application for determination of different synthetic mixtures containing different ratios of the studied drugs. The developed methods have been successfully used for determination of ATR and EZ in their combined dosage form and statistical comparison of the developed methods with the reported spectrophotometric one using F and Student’s t-tests showed no significant difference regarding both accuracy and precision.
基金supported by the National Natural Science Foundation of China (Grant Nos. 51827807 and 51636002)
文摘This paper presents an in-situ, non-contact, non-destructive "dual-wavelength laser flash Raman spectroscopy method" for measuring the thermal diffusivity. In this method, a heating pulse is used to heat the sample and another pulsed laser with a different wavelength and negligible heating effect is used as a probe to measure the sample temperature changes during the heating and cooling periods from the Raman peak shifts. The sample temperature rise and fall curves are measured by changing the delay between the heating pulse and the probing pulse with the thermal diffusivity then characterized by fitting the temperature curves. The time delay between the heating and probing pulses can be precisely controlled with a minimum step of 100 ps. Hence, the temperature variation can be scanned with an ultra-high temporal resolution of up to 100 ps, which significantly improves the measurement accuracy of transient thermal parameters. The measurement accuracy of this method has been verified using a bulk material model and experiments. The measured thermal diffusivity of a silicon sample has been obtained to be 8.8×10^(-5 )m^2/s with a 3% difference between the measured value and the average result for bulk silicon in the literature which verifies the reliability and accuracy of this method.